Plan Review Details - Permit 02100040
Plan Review Stops For Permit 02100040
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-02-12 Cont ID  
Sent By dpalmer Date 2004-02-12 Time 11:51 Rev Time 0.33
Received By dpalmer Date 2004-02-12 Time 11:51 Sent To  
Notes
2004-02-12 00:00:00REDLINED MISSING EQUIPMENT GROUNDING
 CONDUCTORS. 250.122

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-12-09 Cont ID  
Sent By hmoser Date 2003-02-11 Time 16:10 Rev Time 0.00
Received By btrobaug Date 2002-12-09 Time 12:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-11-07 Cont ID  
Sent By dpalmer Date 2002-11-07 Time 05:35 Rev Time 0.50
Received By dpalmer Date 2002-11-07 Time 05:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-10-23 Cont ID  
Sent By btrobaug Date 2002-11-06 Time 16:24 Rev Time 0.50
Received By dpalmer Date 2002-10-23 Time 17:03 Sent To B
Notes
2002-10-23 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE SIZE GROUNDING ELECTRODE
 CONDUCTOR PER 250-66 SHOWN AS #4.
  
 2)NOTE: PLEASE NOTE MISSING EQUIPMENT
 GROUNDING CONDUCTOR BETWEEN MAIN AND
 PANEL "B". SIZE PER 250-122
  
 3)NOTE: PLEASE NOTE A PANEL "C" IS SHOWN
 ON METER/MAIN COMBO AND NOT ON RISER
 OR PLANS? PLEASE SHOW, CONDUIT,WIRE,
 LOCATION ETC 215-5
  
 4)NOTE: PLEASE NOTE THAT PLANS SHOW A
 SD IN KITCHEN. PLEASE NOTE SD IS NOT
 PERMITTED IN KITCHEN PER NFPA-72
 8-1.4.1.6
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-03-24 Cont ID  
Sent By sthyng Date 2003-03-24 Time 08:24 Rev Time 0.00
Received By sthyng Date 2003-03-24 Time 08:24 Sent To M
Notes
2003-03-24 00:00:00REVISION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-31 Cont ID  
Sent By btrobaug Date 2003-01-31 Time 17:30 Rev Time 0.00
Received By btrobaug Date 2003-01-31 Time 17:30 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-12 Cont ID  
Sent By drunnels Date 2002-11-12 Time 15:13 Rev Time 0.25
Received By drunnels Date 2002-11-06 Time 16:23 Sent To  
Notes
2002-11-06 00:00:00TO DVP./WRT

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-03-27 Cont ID  
Sent By pkrauss Date 2003-03-27 Time 15:32 Rev Time 0.40
Received By pkrauss Date 2003-03-27 Time 15:06 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-02-11 Cont ID  
Sent By sthyng Date 2003-03-24 Time 08:24 Rev Time 0.25
Received By hmoser Date 2003-02-11 Time 16:07 Sent To E
Notes
2003-02-11 00:00:00PLAN DENIED
 FLOOR PLAN AND MECHANICAL PLAN DO NOT
 MATCH.
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-10-19 Cont ID  
Sent By btrobaug Date 2003-01-31 Time 17:30 Rev Time 0.33
Received By jleech Date 2002-10-19 Time 11:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-10-19 Cont ID  
Sent By hmoser Date 2003-02-08 Time 12:59 Rev Time 0.25
Received By jleech Date 2002-10-19 Time 11:35 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2003-05-19 Cont ID  
Sent By rmcdouga Date 2003-05-19 Time 13:38 Rev Time 1.00
Received By rmcdouga Date 2003-05-19 Time 13:38 Sent To  
Notes
2003-05-19 00:00:00RESTAMPED PLANS 5-19-03 RM

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2003-05-19 Cont ID  
Sent By pkrauss Date 2003-03-27 Time 15:32 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-29 00:00:00REVISION TO ROOF AND TIE BEAM OK

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-12-01 Cont ID  
Sent By lhatten Date 2002-12-09 Time 08:53 Rev Time 1.00
Received By lhatten Date   Time   Sent To  
Notes
2002-12-09 00:00:00REVISION REMOVE MEDIA ROOM 12/01/2002

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-11-04 Cont ID  
Sent By lhatten Date 2002-11-04 Time 18:37 Rev Time 2.50
Received By lhatten Date 2002-11-02 Time 18:36 Sent To  
Notes
2002-11-04 00:00:00REVIEW& STAMPED PLANS 11/02/2002
 CALC. FEES & PRINT CARD 11/04/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-10-07 Cont ID  
Sent By sgraham Date 2002-10-07 Time 09:28 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***