Plan Review Details - Permit 02091622
Plan Review Stops For Permit 02091622
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-11-27 Cont ID  
Sent By jgomez Date 2002-11-27 Time 14:53 Rev Time 1.50
Received By jgomez Date 2002-11-27 Time 14:52 Sent To  
Notes
2002-11-27 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE STRUCTURAL BUCK DETAILS FOR
 DOORS AND WINDOWS. NOTE: SEE PRODUCT
 APPROVAL FOR SIZE OF BUCK REQUIRED.
 AND SEC. 1707.4.4.2 FBC 2001 FOR
 BUCK REQUIREMENTS.
 2-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE APPLICATION
 AS REQUIRED BY CITY IMPLEMENTATION
 STANDARD FOR HURRICANE MISSILE IMPACT
 PROTECTION.
 3-PROVIDE 2 COPIES OF PRODUCT APPROVAL
 FOR: A)FLAT ROOF SYSTEM TO BE USED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-11-01 Cont ID  
Sent By jgomez Date 2002-11-01 Time 14:58 Rev Time 1.50
Received By jgomez Date 2002-11-01 Time 14:58 Sent To  
Notes
2002-11-01 00:00:00CHECKLIST:
 1-NEED TO PROVIDE RECORDED NOTICE OF
 COMMENCEMENT.
 2-BRING PLANS TO PALM BEACH COUNTY AFTER
 THEY ARE REVISED BY THE DESIGNER TO
 VERIFY IF IMPACT FEES ARE OWED. BRING
 BACK STAMPED DWGS AND PAID RECEIPT.
 3-FLOOR PLANS AND WALL SECTION DON'T
 MATCH. PLANS SHOW CONCRETE BLOCK AND
 WALL SECTION SHOW WOOD FRAMING. REVISE
 4-CLARIFY CONNECTION AT UNION OF NEW
 ROOF TO EXISTING ONE. CONNECTOR SHOWN
 IS FOR EXISTING ROOF TRUSSES OR FOR
 NEW JOISTS?. SEE SIMPSON CATALOGUE FOR
 PROPER UPLIFT CONNECTOR.
 PROVIDE ENGINEERING CALCULATIONS FOR
 CONNECTOR VALUES NOT PUBLISHED IN THE
 SIMPSON CATALOGUE. SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 5-PROVIDE STRUCTURAL BUCK DETAILS FOR
 DOORS AND WINDOWS. NOTE: SEE PRODUCT
 APPROVALS FOR SIZE OF BUCK REQUIRED
 AND SECTION 1707.4.4.2 FBC 2001 FOR
 BUCK REQUIREMENTS.
 6-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS: PRODUCT APPROVAL AND INSTA-
 LLATION SCHEDULE. SEE CITY SAMPLE.
 NOTE: NEED 2 COPIES.
 7-PROVIDE 2 COPIES OF PRODUCT APPROVALS
 FOR: A)FLAT ROOF SYSTEM TO BE USED.
 B)EXTERIOR SWING DOOR (NEED TWO COPIES.
 ONLY ONE WAS SUBMITTED)
 C)SINGLE HUNG WINDOWS. DRAWINGS ARE NOT
 LEGIBLE.
 D)SLIDING GLASS DOOR DRAWINGS ARE NOT
 LEGIBLE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-10-21 Cont ID  
Sent By btrobaug Date 2002-10-21 Time 13:02 Rev Time 0.25
Received By btrobaug Date   Time   Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-13 Cont ID  
Sent By dpalmer Date 2002-11-13 Time 16:15 Rev Time 0.00
Received By dpalmer Date 2002-11-13 Time 16:15 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-10-22 Cont ID  
Sent By pkrauss Date 2002-10-22 Time 12:32 Rev Time 0.30
Received By pkrauss Date 2002-10-22 Time 12:01 Sent To  
Notes
2002-10-22 00:00:00NO MECHANICAL INFORMATION SUBMITTED FOR
 REVIEW.LIVING ROOM ADDITION = 300 SQ
 FT.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-11-19 Cont ID  
Sent By pschmitz Date 2002-11-19 Time 09:02 Rev Time 0.50
Received By pschmitz Date   Time   Sent To  
Notes
2002-11-19 00:00:00PLUMBING SHOWN ON PLANS IS EXISTING,
 NO PLUMBING FOR ADDITION. PES

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-10-22 Cont ID  
Sent By dpalmer Date 2002-11-13 Time 16:15 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-10-22 00:00:00PLUMBING PLAN REVIEW FBC 2002, DENIED
 (1) SHT 5,PLBG ISOMETRIC DOES NOT MATCH
 FLOOR PLAN ON SHT 2.
 (2) SHT 5, AIR CHAMBERS NOT ALLOWED, USE
 WATER HAMMER ARRESTORS, INSTALL AS CLOSE
 TO THE SOURCE AS POSSIBLE, NOT AT HIGH
 POINT OF SYSTEM. SEC604.9
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS561-659-8096X8233

Review Stop Z ZONING
Rev No 1 Status P Date 2002-10-07 Cont ID  
Sent By sgraham Date 2002-10-07 Time 09:37 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***