Plan Review Details - Permit 02091622
| Plan Review Stops For Permit 02091622 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-11-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-11-27 |
Time |
14:53 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2002-11-27 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2002-11-27 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE STRUCTURAL BUCK DETAILS FOR | | | DOORS AND WINDOWS. NOTE: SEE PRODUCT | | | APPROVAL FOR SIZE OF BUCK REQUIRED. | | | AND SEC. 1707.4.4.2 FBC 2001 FOR | | | BUCK REQUIREMENTS. | | | 2-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS UNDER A SEPARATE APPLICATION | | | AS REQUIRED BY CITY IMPLEMENTATION | | | STANDARD FOR HURRICANE MISSILE IMPACT | | | PROTECTION. | | | 3-PROVIDE 2 COPIES OF PRODUCT APPROVAL | | | FOR: A)FLAT ROOF SYSTEM TO BE USED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-11-01 |
Time |
14:58 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2002-11-01 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2002-11-01 00:00:00 | CHECKLIST: | | | 1-NEED TO PROVIDE RECORDED NOTICE OF | | | COMMENCEMENT. | | | 2-BRING PLANS TO PALM BEACH COUNTY AFTER | | | THEY ARE REVISED BY THE DESIGNER TO | | | VERIFY IF IMPACT FEES ARE OWED. BRING | | | BACK STAMPED DWGS AND PAID RECEIPT. | | | 3-FLOOR PLANS AND WALL SECTION DON'T | | | MATCH. PLANS SHOW CONCRETE BLOCK AND | | | WALL SECTION SHOW WOOD FRAMING. REVISE | | | 4-CLARIFY CONNECTION AT UNION OF NEW | | | ROOF TO EXISTING ONE. CONNECTOR SHOWN | | | IS FOR EXISTING ROOF TRUSSES OR FOR | | | NEW JOISTS?. SEE SIMPSON CATALOGUE FOR | | | PROPER UPLIFT CONNECTOR. | | | PROVIDE ENGINEERING CALCULATIONS FOR | | | CONNECTOR VALUES NOT PUBLISHED IN THE | | | SIMPSON CATALOGUE. SECTION 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | 5-PROVIDE STRUCTURAL BUCK DETAILS FOR | | | DOORS AND WINDOWS. NOTE: SEE PRODUCT | | | APPROVALS FOR SIZE OF BUCK REQUIRED | | | AND SECTION 1707.4.4.2 FBC 2001 FOR | | | BUCK REQUIREMENTS. | | | 6-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS: PRODUCT APPROVAL AND INSTA- | | | LLATION SCHEDULE. SEE CITY SAMPLE. | | | NOTE: NEED 2 COPIES. | | | 7-PROVIDE 2 COPIES OF PRODUCT APPROVALS | | | FOR: A)FLAT ROOF SYSTEM TO BE USED. | | | B)EXTERIOR SWING DOOR (NEED TWO COPIES. | | | ONLY ONE WAS SUBMITTED) | | | C)SINGLE HUNG WINDOWS. DRAWINGS ARE NOT | | | LEGIBLE. | | | D)SLIDING GLASS DOOR DRAWINGS ARE NOT | | | LEGIBLE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-10-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-21 |
Time |
13:02 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-13 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-11-13 |
Time |
16:15 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-10-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-10-22 |
Time |
12:32 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-10-22 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2002-10-22 00:00:00 | NO MECHANICAL INFORMATION SUBMITTED FOR | | | REVIEW.LIVING ROOM ADDITION = 300 SQ | | | FT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-11-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2002-11-19 |
Time |
09:02 |
Rev Time |
0.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-11-19 00:00:00 | PLUMBING SHOWN ON PLANS IS EXISTING, | | | NO PLUMBING FOR ADDITION. PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-13 |
Time |
16:15 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-22 00:00:00 | PLUMBING PLAN REVIEW FBC 2002, DENIED | | | (1) SHT 5,PLBG ISOMETRIC DOES NOT MATCH | | | FLOOR PLAN ON SHT 2. | | | (2) SHT 5, AIR CHAMBERS NOT ALLOWED, USE | | | WATER HAMMER ARRESTORS, INSTALL AS CLOSE | | | TO THE SOURCE AS POSSIBLE, NOT AT HIGH | | | POINT OF SYSTEM. SEC604.9 | | | END OF COMMENTSPAUL SCHMITZ | | | QUESTIONS561-659-8096X8233 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-10-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-10-07 |
Time |
09:37 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|