Plan Review Details - Permit 02091330
Plan Review Stops For Permit 02091330
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-30 Cont ID  
Sent By btrobaug Date 2002-12-30 Time 15:31 Rev Time 0.25
Received By btrobaug Date   Time   Sent To R
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-09-27 Cont ID  
Sent By btrobaug Date 2002-09-27 Time 13:50 Rev Time 0.50
Received By btrobaug Date 2002-09-27 Time 13:34 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-24 Cont ID  
Sent By jgomez Date 2004-02-24 Time 16:45 Rev Time 0.00
Received By jgomez Date 2004-02-24 Time 16:44 Sent To PC
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2011-07-20 Cont ID  
Sent By hmoser Date 2011-07-20 Time 15:33 Rev Time 0.00
Received By hmoser Date 2011-07-20 Time 15:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-01-10 Cont ID  
Sent By pkrauss Date 2003-01-10 Time 14:10 Rev Time 0.15
Received By pkrauss Date 2003-01-10 Time 14:09 Sent To  
Notes
2003-01-10 00:00:00MECHANICAL PERMIT 02091351
 NO PLANS SUBMITTED, ADDITION MASTER
 BEDROOM & BATHROOM. 2 EXHAUST FANS
 INDICATED ON PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-10-02 Cont ID  
Sent By pkrauss Date 2002-10-02 Time 14:03 Rev Time 0.25
Received By pkrauss Date 2002-10-02 Time 14:01 Sent To R
Notes
2002-10-02 00:00:00DENIED:MECHANICAL PERMIT 02091357
  
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.
  
 PLEASE PROVIDE A COMPLETED FORM 600C-01.
 INDICATE IF THE COOLING/HEATING SYSTEM
 IS EXISTING OR NEW.PROVIDE
 MANUFACTURER INFORMATION ON THE
 EQUIPMENT (MAKE, MODEL, BTU'S & SEER OF
 THE CONDENSER).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-12-30 Cont ID  
Sent By pschmitz Date 2002-12-30 Time 15:36 Rev Time 0.33
Received By pschmitz Date   Time   Sent To  
Notes
2002-12-30 00:00:00REV. APPR. PES

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-10-02 Cont ID  
Sent By btrobaug Date 2002-09-27 Time 13:51 Rev Time 0.66
Received By pschmitz Date   Time   Sent To  
Notes
2002-10-02 00:00:00APPR, PES.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2004-02-24 Cont ID  
Sent By jgomez Date 2004-02-24 Time 16:44 Rev Time 0.25
Received By jgomez Date 2004-02-24 Time 16:44 Sent To PC
Notes
2004-02-24 00:00:00ENGINEER LETTER FOR HURRICANE STRAP.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2003-01-10 Cont ID  
Sent By btrobaug Date 2002-12-30 Time 15:31 Rev Time 2.00
Received By jgomez Date 2002-12-30 Time 12:13 Sent To  
Notes
2003-01-10 00:00:00BUILDING REVIEW NOTES:
 1-PROVIDE PRODUCT APPROVAL (2 COPIES)FOR
 SINGLE HUNG WINDOWS AS SHOWN ON PLANS.
 2-PROVIDE PRODUCT APPROVAL FOR FLAT ROOF
 SYSTEM TO BE USED. SEE PLANS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-11-27 Cont ID  
Sent By jgomez Date 2002-11-27 Time 10:11 Rev Time 0.50
Received By jgomez Date 2002-11-27 Time 10:11 Sent To  
Notes
2002-11-27 00:00:00CHECKLIST:
 1-ENGINEER TO PROVIDE ALL INFORMATION
 REQUESTED ON CHECKLIST DATED 10-17-02.
 STILL MISSING SOME INFORMATION THAT
 WAS REQUESTED ON PREVIOUS CHECKLIST.
 **NOTE: ENGINEER TO PROVIDE REQUESTED
 INFORMATION ON ORIGINAL DRAWINGS. TWO
 NEW PRINTS ARE REQUIRED ALONG WITH THE
 ORIGINAL SIGNATURE, SEAL AND DATE.
 RETURN REVIEWED SET TO EXPEDITE THE
 REVIEW PROCESS.
 2-OWNER TO REVIEW CHECKLIST DATED 10-17-
 02 FOR ITEMS TO BE PROVIDED TO THIS
 OFFICE.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-10-17 Cont ID  
Sent By pkrauss Date 2002-10-02 Time 14:12 Rev Time 1.50
Received By jgomez Date 2002-10-17 Time 16:13 Sent To  
Notes
2002-10-17 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-TAKE DRAWINGS TO PALM BEACH COUNTY
 AFTER THEY ARE REVISED TO VERIFY IF
 IMPACT FEES ARE DUE. BRING BACK PAID
 RECEIPT AND STAMPED DRAWINGS.
 3-PROVIDE ALL THE INFORMATION REQ'D ON
 DRAWINGS. SEE SEC. 1606.1.7 FBC 2001.
 4-ENGINEER TO PROVIDE HIS INFORMATION AS
 REQUIRED BY CHAPTER 471 FL. STATUTES
 WHEN SUBMITTING DOCUMENTS FOR PUBLIC
 RECORDS.
 5-IDENTIFY ROOMS IN EXISTING HOUSE TO
 VERIFY FOR EGRESS REQUIREMENTS. SEC.
 1005.4.4 FBC 2001. SPECIFY EGRESS FOR
 BEDRMS THAT AFFECTED BY THE ADDITION.
 6-PROVIDE ROOF FRAMING PLAN AND PROVIDE
 DETAILS AND SPECS FOR ATTACHMENT OF
 NEW ROOF TO EXISTING ONE. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 **CLEARLY SPECIFY SIZE OF TRUSS ANCHOR.
 7-SPECIFY TYPE AND GRADE OF STRUCTURAL
 WOOD USED FOR ROOF FRAMING. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 8-COMPLETELY SPECIFY HOW'S NEW STRUCTURE
 ATTACHED TO EXISTING ONE. SPECIFY SIZE
 & ATTACHMENT OF DOWELS TO WALLS AND
 FOOTING. SEC. 104.2.1.2 CITY AMENDMENT
 9-CLARIFY IF NEW ROOF IS TO BE FLAT OR
 PITCHED. ELEVATIONS SHOW PITCHED ROOF
 BUT WALL SECTION SHOW FLAT ROOF. ALSO,
 IF FLAT ROOF, THEN REVISE PITH TO 1/4"
 PER FT. SEC. 1508 FBC 2001.
 **NOTE: IF GABLE END, THEN PROVIDE COM-
 PLETE SECTION/DETAIL THAT COMPLIES W/
 SEC. 2117 FBC 2001.
 10-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE SEC. 2405.2 FBC 2001.
 11-PROVIDE ENERGY CALCULATIONS FOR THE
 ADDITION. SEC. 600.2.A.3 CHAPTER 13
 FBC 2001.
 12-SPECIFY FASTENING TYPE & SPACING FOR
 ROOF SHEATHING. SEE TABLE 2306.1 CITY
 AMENDMENTS TO FBC 2001.
 13-CLARIFY SIZE OF ROOF FRAMING MEMBERS.
 2X10'S OR 2X12'S. SEE HAND WRITTEN
 INFORMATION ON WALL SECTION.
 14-SPECIFY BOND BEAM HEIGHT, REINFORCE-
 MENT. CLARIFY WHAT'S SIMPSON TPGA210
 HURRICANE STRAP (UNABLE TO FIND IN THE
 SIMPSON CATALOGUE) AND WHAT IS IT FOR
 AT THE BOND BEAM?. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 15-SPECIFY WINDOW SILL. SIZE AND REINFOR
 CEMENT. SEC. 104.2.1.2 CITY AMENDMENTS
 16-STORM SHUTTERS: SPECIFY ON PRODUCT
 APPROVAL SPECIFIC MOUNTING CONDITIONS
 AND ANCHOR TYPE AND SPACING.
 PROVIDE KEY PLAN AND INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 17-PROVIDE PRODUCT APPROVAL FOR:
 A)ROOF SYSTEM (FLAT OR PITCHED)
 B)SINGLE HUNG WINDOWS PRODUCT APPROVAL
 BY PAN AMERICAN: 1)PAN AMERICAN IS OUT
 OF BUSINESS. 2)DRAWINGS AREN'T LEGIBLE
 3)MISSING SOME DRAWINGS.
 C)"STA-TRU" OUTSWING DOOR PRODUCT APPRO-
 VAL: 1)DRAWINGS DON'T MATCH REPORT.
 PROVIDE 2 SETS.
 18-REVISE DOOR STRUCTURAL BUCK DETAIL.
 SEE SEC. 1707.4.4.2 FBC 2001.
 19-SPECIFY WWM SUPPORTS AND SPACING IN
 CONCRETE SLAB. OR DESIGN JOINTS. SEE
 SEC. 1909.3 FBC 2001.
 20-SEE PLANS FOR ADDITIONAL COMMENTS AND
 RETURN REVIEWED SETS AFTER CORRECTIONS
 ARE DONE TO ORIGINAL DRAWINGS TO
 EXPEDITE REVIEW PROCESS.
 21-VALUE DECLARED FOR CONSTRUCTION IS
 TOO LOW. OWES $257.31 FOR VALUATION
 AND RADON FEES.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-09-25 Cont ID  
Sent By sgraham Date 2002-09-25 Time 16:31 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***