| Plan Review Stops For Permit 02091027 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-29 |
Time |
16:02 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2004-06-29 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | SUBMITTAL 4080 HMD-F FLUSH OUTSWING | | | COMMERCIAL STEEL DOOR-IMPACT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-29 |
Time |
15:58 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-06-29 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | SUBMITTAL 6-28-04 RE: MANAGERS OFFICE | | | (NEW PARTITION)JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-29 |
Time |
15:36 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-06-29 |
Time |
15:36 |
Sent To |
PC |
|
| Notes |
| 2004-06-29 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 02091027 | | | ADD: 1600 PRESIDENTIAL WAY | | | CONT: AVS CONSTRUCTION | | | TEL: (954)655-5162 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | SUBMITTAL: FIRE RATED CHASE FOR ELECTRIC | | | AL CONDUIT IN STAIR TOWER | | | | | | ACTION: DENIED | | | 1) 1006.1.3.1 PENETRATIONS INTO & OPEN- | | | INGS THROUGH A STAIRWAY ENCLOSURE | | | ASSEMBLY ARE PROHIBITED EXCEPT FOR | | | REQUIRED EXIT DOORS, DUCTWORK & EQUIP- | | | MENT NECCESSARY FOR INDEPENDENT STAIR | | | PRESSURIZATION, SPRINKLER PIPING, | | | STANDPIPES, AND ELECTRICAL CONDUIT SERV- | | | ING THE STAIRWAY AND TERMINATING AT A | | | STEEL BOX NOT EXCEEDING 16 SQ IN.SUCH | | | PENETRATIONS SHALL BE PROTECTED IN | | | ACCORDANCE WITH 705.4. THERE SHALL BE NO | | | PENETRATIONS OR COMMUNICATING OPENINGS, | | | WETHER PROTECTED OR NOT, BETWEEN ADJA- | | | CENT STAIRWAYS. | | | | | | 2) THE SECOND ISSUE IS NO LOCATION IS | | | GIVEN IN THE STAIRWAY, SEE 1007.4.2. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-28 |
Time |
14:25 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-05-03 00:00:00 | REVISION: 2" HOLE IN ELEVATOR HEADER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-03 |
Time |
14:32 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-12-11 00:00:00 | REVISION : STAIR TOWER LOCATION 3 SHEETS | | | 8X11 FOR B- STAIR TOWERJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-09-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-09-26 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-09-26 00:00:00 | ALL REVIEWS UNDER MASTER # 02060714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-09-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-26 |
Time |
06:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-09-26 |
Time |
06:23 |
Sent To |
|
|
| Notes |
| 2002-09-26 00:00:00 | 02060714 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-12-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-12-19 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-19 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-28 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-28 |
Time |
14:25 |
Sent To |
B |
|
| Notes |
| 2004-06-28 00:00:00 | TO JW DESK/SUBMITTAL/FIRE RATED CHASES | | | FOR ELECTRICAL CONDUIT IN STAIR TOWER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-03 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-03 |
Time |
14:32 |
Sent To |
B |
|
| Notes |
| 2004-05-03 00:00:00 | TO JW DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-17 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-17 |
Time |
11:32 |
Sent To |
B |
|
| Notes |
| 2003-07-17 00:00:00 | JW DESK, 5 SUBMITTALS, PRODUCT APPROVALS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-17 |
Time |
16:09 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-07-17 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2003-07-17 00:00:00 | MECH REV - REVISION FILED WITH MASTER | | | PERMIT 02060714 |
|
|