Plan Review Details - Permit 02091026
Plan Review Stops For Permit 02091026
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-12-09 Cont ID  
Sent By hpiskura Date 2002-12-09 Time 10:04 Rev Time 0.00
Received By hpiskura Date 2002-12-09 Time 10:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-11-08 Cont ID  
Sent By hpiskura Date 2002-11-08 Time 09:01 Rev Time 0.00
Received By hpiskura Date 2002-11-07 Time 14:17 Sent To  
Notes
2002-11-08 00:00:00PLEASE PROVIDED A SITE PLAN/SURVEY
 SHOWING THE LOCATION OF THE PENETRATION
 OF THE TWO HOUR FIRE RATED EXTERIOR
 WALL AS INDICATED IN SECTION (2 A/6)
  
 SEE FBC 705.1.1 AND FBC M506.3.14.2 IF
 APPLICABLE, AND FBC M401.5.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-30 Cont ID  
Sent By hpiskura Date 2002-09-30 Time 13:12 Rev Time 0.00
Received By hpiskura Date 2002-09-30 Time 11:52 Sent To  
Notes
2002-09-30 00:00:00PLEASE PROVIDE A CONSTRUCTION DETAIL FOR
 THE CUTTING OF THE FLOOR/CEILING
 ASSEMBLIES FOR THE PROPOSED HOOD VENT
 SYSTEM.INCLUDE SHAFT CONSTRUCTION
 DETAILS AND FIRE DESIGN NUMBERS.SEE
 FBC 705.2.
  
 PROVIDE A SPECIFIC CONSTRUCTION DETAIL
 FOR THE SOFFIT SHOWN ON SHEET A3.
 INCLUDE CONNECTIONS TO THE EXISTING
 STRUCTURE ABOVE.SEE FBC 104.2.1.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-09-20 Cont ID  
Sent By dpalmer Date 2002-09-20 Time 07:14 Rev Time 0.50
Received By dpalmer Date 2002-09-20 Time 07:14 Sent To  
Notes
2002-09-20 00:00:00NOTE REDLINED ON PLAN TO VERIFY LOCATION
 OF WATER HEATER. PLEASE SEE OTHER REVIEW
 -ERS NOTES.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-12-18 Cont ID  
Sent By pkrauss Date 2002-12-18 Time 11:24 Rev Time 0.00
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-11-14 Cont ID  
Sent By mcarsill Date 2002-09-24 Time 14:44 Rev Time 0.00
Received By mcarsill Date 2002-09-24 Time 14:44 Sent To  
Notes
2002-09-24 00:00:001) PLEASE PROVIDE THIS OFFICE A LETTER
 INDICATING THAT NO COOKING THAT
 PRODUCES SMOKE OR GREASE LADEN VAPORS
 WILL BE PERFORMED ON SITE.
  
 2) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION INFORMATION FOR WALLS
 AND CEILINGS.
  
 3) PLEASE SUBMIT SEPARATE PLANS AND
 PERMITS FOR FIRE SPRINKLER SYSTEM
 REMODEL.
  
 4) PLEASE SUBMIT SEPARATE PLANS AND
 PERMITS FOR FIRE ALARM SYSTEM REMODEL.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-02 Cont ID  
Sent By btrobaug Date 2002-12-02 Time 17:22 Rev Time 0.00
Received By btrobaug Date 2002-12-02 Time 17:21 Sent To  
Notes
2002-12-02 00:00:00TO COMM BOARD #20./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-05 Cont ID  
Sent By btrobaug Date 2002-11-05 Time 16:46 Rev Time 0.00
Received By btrobaug Date 2002-11-05 Time 16:46 Sent To  
Notes
2002-11-05 00:00:00TO COMM BOARD # 30./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2003-04-25 Cont ID  
Sent By hmoser Date 2003-04-25 Time 15:32 Rev Time 0.50
Received By hmoser Date 2003-04-25 Time 15:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-12-18 Cont ID  
Sent By pkrauss Date 2002-12-18 Time 11:22 Rev Time 0.40
Received By pkrauss Date 2002-12-18 Time 11:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2002-11-13 Cont ID  
Sent By pkrauss Date 2002-11-13 Time 16:51 Rev Time 0.40
Received By pkrauss Date 2002-11-13 Time 16:51 Sent To  
Notes
2002-11-13 00:00:00DENIED:
  
 SEE COMMENTS FROM BUILDING PLAN REVIEW.
 PLEASE CLARIFY 2-HOUR RATING OF EXTERIOR
 WALL.WHY IS THIS A 2 HOUR WALL,
 BECAUSE OF CONSTRUCTION, PROXIMITY TO
 PROPERTY LINES, BUILDINGS ETC?
  
 ANY PENETRATIONS THROUGH A "RATED" WALL
 SHALL BE PROTECTED IN ACCORDANCE WITH
 2001 FBC(M) 607.1.2.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-10-15 Cont ID  
Sent By pkrauss Date 2002-10-15 Time 15:13 Rev Time 0.45
Received By pkrauss Date 2002-10-15 Time 15:08 Sent To  
Notes
2002-10-15 00:00:00PLANS FOR THE HVAC APPROVED
  
 DENIED:
  
 ADDITIONAL PERMIT REQUIRED FOR THE HOOD
 & WALK-IN COOLER/FREEZER.
  
 INDICATE ON PLAN CLEARANCE FOR HOOD.
 SEE ALSO COMMENTS FROM H. PISKURA,
 BUILDING PLAN REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-12-11 Cont ID  
Sent By kstevens Date 2002-12-11 Time 09:54 Rev Time 0.50
Received By kstevens Date 2002-12-11 Time 09:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-11-19 Cont ID  
Sent By kstevens Date 2002-11-19 Time 08:00 Rev Time 0.75
Received By kstevens Date 2002-11-19 Time 08:00 Sent To  
Notes
2002-11-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT P-1 LETTER FROM RODNEY COMPO RE-
 QUIRES A SAMPLE POINT. PLEASE INDICATE
 ON RISER DIAGRAM AND FLAT DRAWING.
 (SEE SHT P-1 FOR LOCATION)
 2) SHT P-1 WASH MACHINE SHALL NOT DRAIN
 INTO GREASE WASTE LINE, (SEE SHT P-1 FOR
 CHANGE REQUIRED.)
 3) RPZ BACKFLOW REQUIRED. PLEASE INDICA-
 TE ON PLANS. BACKFLOW SHALL BE LOCATED
 MAXIMUM OF 4' A.F.F. AND DRAINED IN-
 DIRECTLY INTO A FLOOR SINK OR THE MOP
 SINK.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-10-05 Cont ID  
Sent By kstevens Date 2002-10-05 Time 10:43 Rev Time 0.00
Received By kstevens Date 2002-10-05 Time 10:31 Sent To  
Notes
2002-10-05 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) GREASE TRAP SIZING SHALL BE BY ROD
 COMPO (561) 837-4074. WASTE ORD. #2938-
 96. IF EXISTING GREASE LINE IN SPACE,
 TIE FLOOR DRAINS, THREE COMP. SINK AND
 MOP SINK INTO GREASE LINE.
 2) SHT P-1, FLOOR DRAIN IN WOMENS TOILET
 ROOM #103 IS NOT VENTED. PLEASE DRAIN
 FLOOR DRAIN INTO VENTED LINE FOR LAV.
 3) SHT P-1 GENERAL NOTES #16. AIR CHAMB-
 ERS ARE NOT APPROVED. PLEASE DELETE REF-
 ERENCE.
 4) SHT P-1, FLOOR DRAIN FOR FREEZER COND
 ENSATE NOT APPROVED. FLOOR SINK REQUIRED
 FOR ALL INDIRECT WASTE. SEC 802.3
 5) SHT P-1, WATER RISER DIAGRAM, PLEASE
 MOVE WATER HAMMER ARRESTORS NEXT TO
 WASHER (BETWEEN LAST TWO FIXTURES) AS
 THEY ARE REQUIRED AT WASH MACHINES.
 6) RPZ BACKFLOW REQUIRED ON WATER SERV-
 ICE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status N Date 2002-12-18 Cont ID  
Sent By pkrauss Date 2002-12-18 Time 13:09 Rev Time 0.00
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***