| Plan Review Stops For Permit 02090928 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-12-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-20 |
Time |
16:00 |
Rev Time |
3.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-12-15 00:00:00 | APPROVED REVISIONLM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-05 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-01 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-02-19 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-19 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-19 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2003-02-19 00:00:00 | PAID PLAN REVIEW NOT A PERMIT | | | APPLICATION. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO THE | | | COUNTY, THE PERMIT PLANS STAMPED BY | | | THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. | | | | | | THE SPECIFICATIONS BOOKS ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE SEVERAL | | | DESIGN PROFESSIONALS WHEN SUBMITTED FOR | | | PUBLIC RECORD.FBC 104.2.2. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-28 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-10-28 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-10-24 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2002-10-28 00:00:00 | PAID PLAN REVIEW, NOT A PERMIT | | | APPLICATION. | | | | | | AT THE TIME OF PERMIT APPLICATION A | | | RECENT PROPERTY SURVEY AND A SITE PLAN | | | WITH DIMENSIONS LOCATING ALL OF THE | | | STRUCTURES RELATIVE TO THE PROPERTY | | | LINES AND EACH OTHER WILL BE NECESSARY. | | | | | | SHOW THE DESIGN INFORMATION FOR THE | | | PRE-ENGINEERED BUILDINGS. | | | | | | ALL GLAZED PORTIONS OF THE EXTERIOR WALL | | | AND ROOF OF THE BUILDING MUST COMPLY | | | WITH THE HURRICANE MISSILE IMPACT | | | RESISTANCE REQUIREMENTS OF FBC 1606.1.4 | | | INCLUDING THE TRANSLUCENT PANELS.SEE | | | ALSO FBC 2604.4 RE: WALL PANELS. | | | | | | THE ARCHITECTURAL SHEET A6.3 DECLARES | | | EXPOSURE B, AND S1 CITES EXPOSURE C. | | | PLEASE CLARIFY WHO WILL BE ENGINEER OF | | | RECORD AND WHAT PORTIONS OF DESIGN ARE | | | TO BE DELEGATED. | | | | | | SHOW THE STRUCTURAL INFORMATION FOR THE | | | OVER HEAD CRANE. | | | | | | SHEET A 4.1 SHOWS VARIOUS EXTERIOR WALL | | | ASSEMBLIES.PROVIDE THE STRUCTURAL | | | DETAILS AS TO THE TYPE OF CONNECTIONS | | | AND THE LOADS TRANSFERRED TO THE METAL | | | BUILDING SYSTEM. | | | | | | WHAT IS THE MATERIAL CALLED OUT AS >>1" | | | MASONRY MAT CONT AS SPECIFIED<< ON | | | SHEET A4.1 AND ELSEWHERE? | | | | | | HOW WERE THE DOOR AND WINDOW PRESSURES | | | ON SHEET A6.3 DETERMINED? | | | | | | SHEET A6.2, HOW ARE THE VARIOUS DOOR AND | | | WINDOW HEADER/SILL,ETC. ATTACHED TO | | | THE BUILDING? | | | | | | SHEET S1 CALLS FOR FOOTINGS TO BE POURED | | | WITHOUT FORMS.CITY AMENDMENTS TO FBC | | | 1804.1.1 REQUIRE ALL FOOTINGS AND | | | CONCRETE PADS TO BE FORMED FULL DEPTH. | | | PLEASE REVISE AS NECESSARY. | | | | | | SHOW THE DESIGN INFORMATION FOR THE | | | REINFORCED MASONRY, IE F'M, GROUT | | | STRENGTH, ETC.SEE FBC 2103.1. | | | | | | SHOW THE PROVISIONS FOR TERMITE | | | PROTECTION IN ACCORDANCE WITH FBC | | | 1816.1.7. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-20 |
Time |
16:00 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-07-20 |
Time |
16:00 |
Sent To |
B |
|
| Notes |
| 2004-07-20 00:00:00 | SENT TO BLDG, SOME A & S SHEETS DO NOT | | | CONTAIN CITY STAMP. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
17:08 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-07-16 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2004-07-16 00:00:00 | ********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE NOTE #2 FROM PREVIOUS | | | REVIEW. | | | PLEASE INCLUDE ALL INFORMATION AS REQ- | | | -UIRED UNDER FAC 61G15-23.002 AND | | | FS 471.023. | | | PLEASE SEE THE SHEET THAT WAS CORRECTED | | | E2.1 NOW ONLY HAS NAME AND ENG'S #. | | | | | | PLEASE SEE THAT IS IS REQUIRED OF ANY | | | AND ALL SHEETS DONE BY THIS FIRM, INCLUD | | | -ING OTHER TRADES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-14 |
Time |
15:46 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-07-01 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2004-07-01 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE REVISIONS ON PLANS | | | NEED TO CORRELATE WITH REVISION #'S ON | | | TITLE BLOCK. PLEASE SEE MISSING REV #8? | | | | | | 2)NOTE: PLEASE INCLUDE ALL INFORMATION | | | ON TITLE AS REQUIRED UNDER FAC 61G15-23 | | | .002, FS 471.023. | | | PLEASE SEE LICENSE #'S ARE REQUIRED FOR | | | ALL SHEETS AND TRADES. | | | PLEASE ALSO SEE FAC 61G1-16.004, AND | | | FS 481.219 FOR ARCH'S. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
11:08 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-11-07 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2003-11-07 00:00:00 | ************** UNSAT ************** | | | | | | 1)NOTE: PLEASE INCLUDE ALL INFORMATION | | | IN TITLE BLOCK AS REQUIRED UNDER | | | FAC 61G1-16.002 AND FS481 | | | NAMES, ADDRESS AND ALL LICENSE #'S REQ'D | | | AR`S/ AA'S ETC. | | | NAME OF PERSON SEALING PLANS IS ALSO | | | REQ'D. | | | | | | PLEASE SEE THAT THIS IS REQ'D ON ALL | | | SHEETS AND SETS AND WEATHER OR NOT | | | COMMENT IS MADE ON OTHER REVIEWS. | | | | | | PLEASE SEE COMMENTS FROM OTHERE REVIEWS | | | THAT MAY HAVE AN AFFECT ON ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-04-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-23 |
Time |
10:14 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-23 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-15 |
Time |
06:03 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-15 |
Time |
05:56 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | *********** UNSAT *************** | | | | | | PLEASE SEE THAT NOW ONLY ONE NEW SHEET | | | E-5 WAS SUBMITTED INTO ONE SET. PLEASE | | | SEE PREVIOUS NOTES AND TELEPHONE CONVER- | | | SATION REQUESTING TWO COMPLETED SETS | | | W/ NEW SHEET E-5. | | | PLANS WERE SUBMITTED FOR FORTH REVIEW | | | AND 4TH PLAN REVIEW WAS WAIVED PER | | | BILL STAPLES (ASST BLDG OFFICIAL) | | | | | | PLEASE SEETHE ABOVE NOTES. PLEASE | | | SUBMIT TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | IF THERE ARE ANY QUESTIONS, ONCE AGAIN, | | | PLEASE CALL. OR E-MAIL | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-03-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-25 |
Time |
15:50 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-03-25 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2003-03-25 00:00:00 | ***************** UNSAT *************** | | | | | | PLEASE NOTE, UNABLE TO DO COMPLETE PLAN | | | REVIEW AT THIS TIME. | | | PLANS HAVE COME BACK IN W/OUT SHEET E-5 | | | AND NOTES FROM PREVIOUS REVIEW AND | | | RESPONSE LETTER CAN NOT BE VERIFIED AT | | | THIS TIME. | | | | | | PLEASE TAKE OUT ALL OLD SHEETS AND | | | INSERT NEW SHEETS FOR TWO COMPLETE SETS. | | | ONE SET OF OF OLD SHEETS SHOULD BE | | | SUBMITTED FOR ANY CLARIFICATION THAT | | | MAY BE NEEDED. THESE WILL COME BACK | | | WHEN ISSUED FOR PERMIT. | | | | | | 1)NOTE: PLEASE SEE TRANSFORMER TX-2, | | | STILL ONLY SHOWN TO COLD WATER. THIS | | | CAN BE REDLINED AND DOES NOT NEED TO | | | HAVE NEW E-4 SUBMITTED. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-02-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-21 |
Time |
05:42 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-02-21 |
Time |
05:42 |
Sent To |
|
|
| Notes |
| 2003-02-21 00:00:00 | ************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE 700-12E FOR CIRCUIT- | | | ING OF EM/EXT LTS, PLEASE CLARIFY | | | SHOWING GOING THRU C2 CONTACTOR?? | | | MAY NOT BE SWITCHED. PLANS NEED TO | | | CLARIFY OR NOTE, TO BE ON LINE SIDE OF | | | CIRCUIT IN CONTACTOR. | | | | | | 2)NOTE: PLEASE SEE NOTE 2 OF FIRST | | | REVIEW, PLEASE NOTE CLASS/DIVISION NOTE | | | ON PLAN. IT IS NOTED RECEPTS TO BE AT | | | 24 ", BUT NEEDS TO NOTE ANY BELOW | | | TO BE INSTALLED PER 511. | | | | | | 3)NOTE: PLEASE CLARIFY LOAD SHOWN ON | | | LOAD ANALYSIS FOR RECEPTS? 220-13 | | | | | | 4)NOTE: RESPONSE TO NOTE 7 FROM REVIEW | | | SHOWS TRANSFORMER BEING BONDED TO COLD | | | WATER. PLEASE NOTE IF ANY OF THE COLD | | | WATER LINE IS BROKEN WITH THE USE OF | | | PVC/CPVC OR INTERUPTED BY REPAIR, THE | | | TRANSFORMER WOULD NOT HAVE A GROUND. | | | PLEASE SHOW GOING TO EFFECTIVE GROUND/ | | | BLDG/FOOTER STEEL.THERE IS AN EXCEPT TO | | | USE METAL CWP, HOWEVER, PLEASE SEE FIRST | | | PART OF THIS NOTE, THIS HAS HAPPENED | | | IN THE PAST AND HAS CREATED A LIFE | | | SAFETY ISSUE. | | | | | | 5)NOTE: PLEASE ALSO SHOW GROUNDING AT | | | WASH BLDG. IT SHOWS AN EQUIPMENT GROUND | | | FROM MAIN BLDG, PLEASE SHOW BONDING OF | | | FOOTER STEEL AND COLD WATER. | | | | | | PLANS HAVE MOST COMMENTS ADDRESSED AND | | | ARE IN GOOD SHAPE. PLEASE SUBMIT THE | | | ABOVE INFORMATION FOR REVIEW. IF THERE | | | ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-19 |
Time |
06:32 |
Rev Time |
1.25 |
| Received By |
dpalmer |
Date |
2002-09-19 |
Time |
06:06 |
Sent To |
|
|
| Notes |
| 2002-09-19 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE LABELING OF CIRCUITS | | | ON PANEL SCHEDULE. PLEASE ALSO NOTE | | | LABELING OF EM LTS/EXITS LTS PER 700-12. | | | | | | 2)NOTE: IT IS NOTED THAT PLAN SHOWS/NOTE | | | -S ALL RECEPTS 24" AFF. PLEASE LIST | | | CLASS/DIVISION. PER ART 500. | | | | | | 3)NOTE: PLEASE LIST/CLARIFY PANELS "H" | | | AND "P1? ARE PANEL FEED-THRU? PLEASE | | | SEE 384-15 | | | | | | 4)NOTE; PLEASE CLAIRY "SHOW" WINDOW | | | OUTLETS REQ`D PER 210-62. PLEASE ALSO | | | LIST ON PANEL SCHEDULE. | | | | | | 5)NOTE: PLEASE NOTE THAT PER FS/FAC | | | 553-79 (6)(A) PLANS ARE REQ`D TO BE | | | SIGNED,DATED, AND SEALED BY A PE. | | | PLEASE ALSO NOTE PLANS HAVE A TITLE | | | BLOCK FROM AN ENGINEER THEREFORE REQ`D | | | TO BE SIGNED, DATE AND SEALED PER FAC/FS | | | 61G15-23.002. | | | | | | 6)NOTE: PLEASE NOTE, PANELS ARE SHOWING | | | ALL LOAD CALCS AT CONN LOADS. | | | PLEASE NOTE THAT LOAD CALCULATIONS ARE | | | REQ`D TO BE SHOWN PER 215-5. PLEASE | | | NOTE, 220-3,220-10,220-11,220-13, PLEASE | | | ALSO NOTE ALL CONTINUOUS LOADS ARE TO | | | BE SHOWN AT 125%. 215-3,230-42. | | | | | | 7)NOTE; PLEASE PROVIDE INFORMATION AND/ | | | OR SHOW GROUNDING ELECTRODE SYSTEM PER | | | 250-50. BLDG/FOOTER STEEL, COLD WATER, | | | GRND RODS? PLEASE ALSO NOTE GROUNDING | | | ELECTRODE SYSTEM FOR DETACHED BLDG PER | | | 250-32. | | | PLEASE SHOW DEATIL FOR GROUNDING OF | | | TRANSFORMERS PER 250-31. | | | | | | 8)NOTE:IT IS NOTED THAT AIC RATINGS ARE | | | SHOWN ON PANELS. PLEASE PROVIDE AIC | | | RATINGS FOR ALL NEW EQUIPMENTS. | | | MAINS/PANELS/BRKRS MUST BE RATED FOR | | | AVAILABLE FAULT CURRENT. 110-9. | | | | | | 9)NOTE: PLEASE CLARIFY LOADS BEING | | | SHOWN ON PANEL SCHEDULES AND NOTHING | | | BEING LISTED ON PANELS SCHEDULE? | | | | | | 10)NOTE:PLEASE SEE ANY COMMENTS FROM | | | OTHER REVIEWERS THAT MAY HAVE AN AFFECT | | | ON THE ELECTRICAL PLANS AND/OR LAYOUT.? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-03-24 |
Time |
13:52 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-03-24 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2003-03-24 00:00:00 | PASSED : | | | 1. SEE PERMIT # 03031769 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-02-12 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-02-12 |
Time |
11:27 |
Rev Time |
2.00 |
| Received By |
mamini |
Date |
2003-02-12 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2003-02-12 00:00:00 | PASSED: | | | 1. UNDERGROUND UTILITIES AND CIVIL SITE | | | PLANS FOR THE PROPOSED PROJECT HAS BEEN | | | APPROVED, HOWEVER A SEPARATE PERMIT | | | APPLICATION AND FEES FOR UNDERGROUND | | | UTILITIES AND CIVIL SITE WORKS AT THE | | | TIME OF ACTUAL PERMITTING WILL BE | | | REQUIRED. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-09-24 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-09-24 |
Time |
14:27 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-09-24 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2002-09-24 00:00:00 | FAILED : | | | 1. PLEASE PROVIDE CIVIL/ SITE PLANS FOR | | | OUR REVIEW AND APPROVAL. PLAN MUST | | | INCLUDE STORM WATER, PERVIOUS AND IMPER- | | | VIOUS CALCULATIONS AND POLLUTION | | | PREVENTION (BMPS) . | | | 2. THE NEW WASH CACILITY MUST BE | | | EQUIPPED WITH OIL AND SAND SEPARATOR | | | ASSEMBLIES. CALL RODNEY COMPO FOR CITY | | | REQUIREMENTS AND STANDARDS, 837-4051. | | | 3. A SEPARATE PERMIT APPLICATION AND | | | FEES FOR CIVIL/ SITE UNDERGROUND | | | UTILITIES AT THE TIME OF ACTUAL PERMITT- | | | ING WILL BE REQUIRED. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-11-24 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-11-24 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2003-11-24 00:00:00 | 1) THE FIRE HYDRANT INSTALLED IN THE | | | REAR DISPLAYS FOUR CONCRETE BOLLARDS. | | | THE BOLLARDS SHALL ALLOW FOR 7'-6" | | | CLEARANCE TO THE FRONT AND SIDE OF IT. | | | FOUR FEET CLEARANCE IS REQUIRED TO THE | | | REAR OF THE HYDRANT. | | | | | | 2) ALL WELDING PERFORMED ON SITE MUST | | | BE APPROVED BY THE BUREAU OF FIRE | | | PREVENTION. ALL WELDING SHALL COMPLY | | | WITH NFPA 51B, THE STANDARD FOR CUTTING | | | AND WELDING. NO COMBUSTIBLE MATERIAL | | | IS ALLOWED WITHIN 35 FEET OF ANY | | | WELDING ACTIVITIES. | | | | | | 3) BUILDING ADDRESS NOTE SHOWN ON | | | ELEVATION DRAWINGS SHOULD INDICATE | | | 6" HIGH NUMERALS. | | | | | | 4) PLEASE PROVIDE PRODUCT APPROVALS | | | FOR ROLLING FIRE DOOR. | | | | | | 5) THE EXTERIOR GATES DO NOT HAVE TO | | | OPEN WHEN THE FIRE ALARM SYSTEM | | | ACTIVATES. | | | | | | 6) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-16 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-16 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2003-04-16 00:00:00 | PLANS REVIEWED BY LT. MIKE WENNERGREN | | | ON 04/15/03 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-03-28 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-03-28 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2003-03-28 00:00:00 | 1) THE EXISTING FIRE HYDRANT LOCATED | | | IN THE EQUIPMENT YARD APPEARS TO BE | | | LOCATED DIRECTLY NEXT TO THE BUILDING. | | | THE FIRE HYDRANT LOCATED IN THE REAR | | | YARD IS TO BE A SUFFICIENT DISTANCE | | | FROM THE BUILDING. ALL FIRE HYDRANTS | | | SHALL BE PROVIDED WITH A MINIMUM OF | | | 7'- 6" TO THE FRONT AND SIDES. A MINIMUM | | | OF 4' IS REQUIRED TO THE REAR. | | | | | | 2) AN EXIT SIGN IS MISSING NEAR DOOR | | | LOCATED NEAR COMPRESSOR 131. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-02-26 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-02-26 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2003-02-26 00:00:00 | 1) EXISTING FIRE HYDRANT ON PAGE A0.2 | | | APPEARS TO BE POSITIONED DIRECTLY NEXT | | | TO THE LUBRICATION TANK CONTAINMENT | | | AREA. FIRE HYDRANTS ARE NOT TO BE | | | POSITIONED NEXT TO POTENTIAL HAZARDS | | | AND MINIMUM CLEARANCES ARE REQUIRED TO | | | THEM PER STATE LAW. | | | | | | 2) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR NEW ABOVEGROUND 1000 GALLON FUEL | | | TANK. WHEN SUBMITTED PRODUCT APPROVALS | | | AND CUT SHEETS ARE TO BE PROVIDED. | | | | | | 3) GATES THAT FIRE AND PARAMEDICAL | | | EQUIPMENT ARE EXPECTED PASS THRU MUST | | | BE AT LEAST 20 FEET IN CLEAR WIDTH. | | | | | | 4) PLEASE BE ADVISED THAT ALL CUTTING | | | AND WELDING IS TO BE PERFORMED IN | | | ACCORDANCE WITH NFPA 51B, THE STANDARD | | | FOR CUTTING AND WELDING. A MINIMUM OF | | | 35 FOOT CLEARANCE TO ANY AND ALL | | | COMBUSTIBLE MATERIAL OR FLAMMABLE | | | MATERIALS SHALL BE PROVIDED. NO | | | CUTTING OR WELDING IS TO BE PERFORMED | | | WITHOUT PRIOR FIRE DEPARTMENT APPROVAL. | | | | | | 5) SEPARATE PLANS AND PERMITS FOR ANY | | | SECURITY GATES OR FENCES. | | | | | | 6) TYPICAL FIRE HYDRANT CONNECTION SHOWS | | | A MINIMUM FROM A HYDRANT TO A BOLLARD | | | AS THREE FEET. IT SHOULD BE AT LEAST | | | FOUR FEET. | | | | | | 7) ELECTRONIC SWITCHES ARE REQUIRED ON | | | OS&Y CONTROL VALVES FOR FIRE LINES. | | | | | | 8) FLOOR PLAN SHOULD IDENTIFY AREAS | | | FOR POTENTIAL CUTTING AND WELDING | | | OPERATIONS. | | | | | | 9) BUILDING ELEVATION SHALL SHOW | | | LOCATION OF ADDRESS. | | | | | | 10) PLEASE INDICATE IF ANY FLAMMABLE | | | OR COMBUSTIBLE LIQUIDS WILL BE STORED | | | IN THE BUILDING. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-10-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-10-04 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-10-04 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2002-10-04 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING AND AFTER CONSTRUCTION. | | | IT APPEARS THAT AN ADDITIONAL FIRE | | | HYDRANT WILL BE REQUIRED IN THE REAR | | | YARD. | | | | | | 2) BUILDING ADDRESS REQUIRED. A MINIMUM | | | OF SIX INCH NUMBERS ARE REQUIRED. | | | | | | 3) HOW DOES FIRE RESCUE ACCESS THE | | | MOTORIZED GATES. WHAT PROVISIONS HAVE | | | BEEN MADE TO ALLOW ACCESS. WHAT HAPPENS | | | WHEN LOSS OF POWER OCCURS. ARE THE | | | GATES FAIL SAFE OR FAIL SECURE. | | | | | | 4) NOTE 2 ON PAGE U2. IF THE FIRE ALARM | | | SYSTEM ACTIVATES AFTER HOURS, DO YOU | | | WANT THE GATES TO OPEN, IT COULD POSE A | | | POSSIBLE SECURITY PROBLEM. | | | | | | 5) A KNOX-BOX WILL BE REQUIRED TO ALLOW | | | FOR FIRE RESCUE ACCESS TO THE BUILDING. | | | | | | 6) WILL THERE BE ANY CUTTING OR WELDING | | | DONE ON SITE. IF SO WHERE. | | | | | | 7) MORE DETAILS REQUIRED FOR OIL AND | | | FUEL TANK STORAGE. ALSO THE CITY OF | | | WEST PALM BEACH HAS A HAZARDOUS | | | MATERIALS ORDINANCE. PLEASE REVIEW | | | DOCUMENT. ALSO PLEASE INDICATE ANY | | | WARNING SIGNS, LABELS, AND SAFEQUARDS | | | PLANNED FOR THE OIL AND GAS STORAGE. | | | | | | 8) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM INSTALLATION. | | | | | | 9) EXIT DOOR SHOULD BE RELOCATED AWAY | | | FROM OIL TANKS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-19 |
Time |
17:08 |
Sent To |
E |
|
| Notes |
| 2004-07-19 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-14 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-14 |
Time |
15:46 |
Sent To |
E |
|
| Notes |
| 2004-07-14 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
11:07 |
Sent To |
E |
|
| Notes |
| 2004-06-25 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-12-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-05 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-05 |
Time |
09:41 |
Sent To |
B |
|
| Notes |
| 2003-12-05 00:00:00 | TO HP DESK/SUBMITTAL-ANCHOR BOLTS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-06 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2003-11-06 00:00:00 | TO COMM BD#31 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-04-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-07 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-07 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-03-25 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-13 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2003-03-13 00:00:00 | COMM BOARD #39 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-11 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-11 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2003-02-11 00:00:00 | TO COMM BOARD# 18 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-11 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-04 |
Time |
13:05 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-10 |
Time |
11:58 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-08-10 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2004-08-10 00:00:00 | REVISED CONDENSING UNIT.ORIGINAL | | | SUBMITTAL INDICATED C.U. ON CURB. | | | REVISED TO STANDS.SUBMITTED ENGINEER | | | DETAIL FOR THE ATTACHMENT TO THE ROOF | | | AND HEIGHT OF THE STAND. | | | | | | PLEASE NOTE REVISION WAS SUBMITTED AFTER | | | C.O. WAS ISSUED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-07-28 |
Time |
15:27 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2004-07-28 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2004-07-28 00:00:00 | PLAN DENIED | | | NEED ENGINEER DRAWING NO CONDENSOR STAND | | | TIEDOWN TO ROOF.YOU SENT A ROOF CURB | | | SUBMITTAL.WITH NO SEAL. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-26 |
Time |
06:06 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-07-26 |
Time |
06:00 |
Sent To |
|
|
| Notes |
| 2004-07-26 00:00:00 | REVISION TO THE CURB & PLENUM SIZE. | | | SIGNED, SEALED & DATED ENGINEER LETTER | | | SUBMITTED INDICATING APPROVAL OF THE | | | CHANGES PROPSED BY PREFERRED A/C. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-05-24 |
Time |
13:13 |
Rev Time |
1.00 |
| Received By |
hmoser |
Date |
2004-05-24 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-24 |
Time |
08:52 |
Rev Time |
0.55 |
| Received By |
hmoser |
Date |
2003-11-24 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2003-11-24 00:00:00 | DENIED: | | | 1.PER 2001 FBC(M) 307.2.3, THE | | | AUXILIARY DRAIN LINE SHALL TERMINATE AT | | | A CONSPICUOUS POINT TO SERVE AS AN ALARM | | | THAT THE PRIMARY DRAIN IS RESTRICTED. | | | PLAN P5 INDICATES AUXILIARY DRAIN | | | TERMINATING AT THE SAME POINT AS THE | | | PRIMARY DRAIN.THIS DOES NOT COMPLY | | | WITH CODE REQUIREMENTS.PLEASE | | | CORRECT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-02-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-18 |
Time |
12:12 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2003-02-18 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2003-02-18 00:00:00 | PROVISO: | | | | | | MANUFACTURER SUBMITTAL - LANDA PRESSURE | | | WASHER (GAS).PG 4 ITEM #32 INDICATES | | | INDICATES TYPE B GAS VENT NOT SUITABLE | | | SHOULD STACK TEMPERATURE EXCEED 470 | | | DEGREES F.ITEM #33 DRAFT HOOD SHALL | | | BE INSTALLED IF THIS MACHINE IS GOING TO | | | BE PERMANENTLY INSTALLED & VENTED TO THE | | | OUTSIDE OF THE BUILDING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-10-07 |
Time |
15:16 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2002-10-07 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2002-10-07 00:00:00 | DENIED: | | | | | | 1.PROVIDE INFORMATION ON THE "SERVICE" | | | AREA - WILL THIS BE TO REPAIR | | | EQUIPMENT?PLEASE CLARIFY. | | | | | | 2.PLAN SHEET M3 OUTSIDE AIR PROVISIONS | | | AS PER 2001 FBC(M) TABLE 403.3 OR | | | ASHRAE 62-89 THE OUTSIDE AIR | | | CALCULATION SHALL BE 20 CFM PER | | | PERSON FOR OFFICE, CONFERENCE ROOMS, | | | ETC. NOT 15 CFM AS INDICATED. | | | PLEASE REVISE PLANS FOR ALL AREAS- | | | OFFICE, CONFERENCE, RESTROOMS, | | | LOCKER ROOM ETC. | | | | | | 3.PROVIDE MANUFACTURER INSTALLATION | | | INSTRUCTIONS FOR THE POWER WASHER & | | | FLUE. | | | | | | 4.CLARIFY CONDENSATE & AUXILIARY DRAIN | | | ARE BEING RUN TOGETHER & TERMINATING | | | AT MOP SINK ? (PLAN SHEET P-1). | | | AS PER 2001 FBC(M) 307.2.1, UNITS | | | GREATER THAN 6 TON SHALL DISCHARGE | | | STORM DRAIN OR DRYWELL. CONDENSATE | | | DRAINS MANIFOLDED TOGETHER, SHALL BE | | | SIZED TOGETHER BY AN APPROVED | | | METHOD.PLEASE PROVIDE CALCULATIONS | | | 2001 FBC(M) 307.2.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-13 |
Time |
11:35 |
Rev Time |
3.75 |
| Received By |
kstevens |
Date |
2004-08-13 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2004-08-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 FUEL GAS | | | | | | 1) SHT U1 REVISION #8 NOT SHOWN, NO REV- | | | ISION #5 SHOWN ON THIS REVISION IS SHOWN | | | ON STAMPED SET OF PLANS. PLEASE CLARIFY. | | | SECTION 104.2.1 | | | 2) SHT U1 FOLLOWING ITEMS ARE REMOVED ON | | | THE REVISION THAT ARE NOT CLOUDED OR A | | | REVISION NUMBER ATTACHED: OIL/SAND INTER | | | CEPTOR, FUEL TANK, AND 3" SS LINE. WHY | | | WERE THESE ITEMS REMOVED, AND WHY WERE | | | THESE CHANGES CALLED OUT AS REVISIONS. | | | SECTION 104.2.1 | | | 3) SHT P1 CALLS FOR REVISIONS 8 & 12, | | | BUT THESE REVISIONS ARE NOT SHOWN. WHAT | | | ARE THESE REVISIONS? SECTION 104.2.1 | | | 4) SHT P3 REVISIONS 7, 8, & 12 WERE NOT | | | FOUND ON THIS REVISION. WHAT ARE THESE | | | REVISIONS? SECTION 104.2.1 | | | 5) SHT P5 REVISIONS 8, & 12 WERE NOT | | | FOUND ON THIS REVISION. WHAT ARE THESE | | | REVISIONS? SECTION 104.2.1 | | | | | | ***THE REVISION WAS SUBMITTED AFTER THE | | | CERTIFICATE OF OCCUPANCY HAS BEEN ISSUED | | | AND THE PERMIT IS CLOSED.*** | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-13 |
Time |
13:26 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-12-06 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2003-12-15 00:00:00 | PASSED - PROVISO - FIELD INSPECTOR TO | | | VERIFY SOLINOID TIMER SYSTEM FOR TRAP | | | PRIMERS. - MORE INFORMATION REQUIRED FOR | | | GAS PERMIT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-15 |
Time |
08:03 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-04-15 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | PASSED/PROVISO | | | | | | SEPARATE GAS PERMIT REQUIRED - THE | | | FOLLOWING INFORMATION REQUIRED AT TIME | | | OF GAS APPLICATION. | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-03-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-22 |
Time |
14:14 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2003-03-22 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2003-03-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | | | | 1) SHT U1 DRYWELL SHALL BE MINIMUM OF | | | 12" FROM BLDG SECTION 1503.4.4. SURFACE | | | WATER SHALL NOT DRAIN INTO DRYWELL. A | | | RELIEF VENT WILL BE REQUIRED AS LINE | | | ENTERS DRYWILL OR EXITS BLDG AT GROUND. | | | 2) SHT P-5, WHERE THE CONDENSATE DRAIN | | | PIPES FROM MORE THAN ONE UNIT ARE MANI- | | | FOLDED TOGETHER , THE PIPE OR TUBING | | | SHALL BE SIZED IN ACCORDANCE WITH AN | | | APPROVED METHOD. CONDENSATE WASTE AND | | | DRAIN LINES SHALL NOT DECREASE IN SIZE | | | FROM THE DRAIN PAN CONNECTION. | | | 3) PLEASE CLAIRFY USE FOR DEMUCKING | | | PUMP. IS THERE PIPING CONNECTED TO THE | | | PUMP? | | | 4) BACKFLOW PREVENTORS ARE REQUIRED FOR | | | EACH BLDG. ONLY ONE IS SHOWN. | | | 5) THREE COMMENTS CONCERNING GAS REVIEW | | | WERE NOT ADDRESSED. DO YOU WISH TO NOT | | | REVIEW GAS AT THIS TIME AND ADDRESS | | | THESE COMMENTS WHEN GAS PERMIT IS | | | APPLIED FOR? | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-10-17 |
Time |
12:26 |
Rev Time |
6.00 |
| Received By |
kstevens |
Date |
2002-10-17 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2002-10-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | | | | 1) SHT P1, CONDENSATE SHALL NOT DRAIN | | | INTO SANITARY. IT SHALL BE PIPED SEPAR- | | | ATELY OUTSIDE OF BLDG AND TIED INTO | | | STORM, CATCH BASIN, OR DRYWELL. A RELEIF | | | VENT IS REQUIRED WHERE CONDENSATE EXITS | | | BLDG. CONDENSATE SHALL TERMINATE MINIMUM | | | OF 12" FROM BLDG. SEC 1503.4.4 FBC | | | 2) PLEASE SUBMIT A CONDENSATE RISER DIA- | | | GRAM. CALCULATE PIPE SIZE PER SECTION | | | 307.2.2 FBC-2001 MECH. SHOW PIPE SIZE ON | | | RISER DIAGRAM. | | | 3) PLEASE SUBMIT A WATER RISER DIAGRAM. | | | SHOW ALL PIPE SIZES AND WATER HAMMER | | | ARRESTORS REQUIRED BY 604.9. LOCATE NEAR | | | FIXTURE IN AN "EFFECTIVE RANGE" NOT IN | | | CEILING AT TOP OF DROP. | | | 4) PLEASE SUBMIT A SANITARY RISER DIAG- | | | RAM. WITH ALL HORIZONTAL PIPING AND SIZE | | | PLEASE SUBMIT IN AN ISOMETRIC FORM. | | | 5) SHTS P1 & P4, RISERS AND FLOOR PLAN | | | DO NOT MATCH. PLEASE CLAIRFY. | | | 6) SHTS P1 & P4 INDIRECT WASTE FROM ICE | | | MACHINE SHALL NOT DRAIN TO FLOOR DRAIN. | | | FLOOR SINKS ARE REQUIRED FOR ALL INDIR- | | | ECT WASTE. SEC. 802.3 | | | 7) SHT P4 RISER P3, HORIZONTAL DRY VENTS | | | ARE NOT APPROVED, (AT FLOOR DRAIN). SECS | | | 905.3 & 905.4 | | | 8) SHT P4 RISER P3, DOES NOT REFLECT | | | FLOOR PLAN. FITTING SHOW DIRECTION OF | | | FLOW TO THE RIGHT, (3" PIPE), AND 4" | | | PIPE IS TO THE LEFT. ALSO FLOOR PLAN | | | SHOWS RISERS P7 & P2 TYING INTO BLDG | | | DRAIN (P3) BETWEEN URNAL AND W/C BUT NOT | | | REFLECTED ON RISER. THIS CAN BE CORRECT- | | | ED BY SUBMITTING COMPLETE SANITARY RISER | | | DIAGRAM REQUESTED IN COMMENT #4 AS THE | | | RISERS SHOWN ARE NOT ACTUAL ISOMETRIC | | | RISER DIAGRAMS. | | | 9) SHT P3 SAND/0IL INTECEPTOR DETAIL, | | | PLEASE CONTACT ROD COMPO, ENVIRONMENTAL | | | COMPLIANCE MANAGER FOR SIZE OF INTECEPT- | | | OR. (561) 837-4074 - ALSO MINIMUM WALL | | | SIZE SHALL BE 3", AND BOTTOM SHALL BE 4" | | | PLEASE SHOW ON DETAIL. | | | 10) PLEASE CLAIRFY USE FOR DEMUCKING | | | PUMP. IS THERE PIPING CONNECTED TO THIS | | | PUMP. | | | 11) SHT P3, HORIZONTAL DRY VENT FOR | | | FLOOR SINK NOT APPROVED. SECS 905.3 & | | | 905.4 | | | 12) BACKFLOWS ARE REQUIRED FOR EACH BLDG | | | 13) FOLLOWING GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | GAS CODE. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | FBC-2001 FUEL GAS CODE SECS.401.8 THRU | | | 402.5 AND TABLES 402(2) THRU 402(34). | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUELGAS | | | CODE SEC. 304. | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 GAS CODE SEC. 402.2. IF | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAS CODE SEC | | | 304. | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2001 | | | FUEL GAS CODE SEC. 402.2 | | | 10. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | 11. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2003-03-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-03-25 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-11 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-02-11 00:00:00 | DENIED, MUST SUBMIT APPROVED SITE PLAN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-04 |
Time |
13:05 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-16 00:00:00 | 1.A 10X25 LOADING IS REQUIRED ON | | | SITE. | | | 2.OUTDOOR STORAGE AND DISPOSAL OF | | | GOODS MUST BE SCREENED FROM VIEW | | | 3.PROVIDE A DETAIL OF PROPOSED FENCE | | | /WALL AND GATES | | | 4.PROVIDE LANDSCAPE PLAN |
|
|