Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-10-11 Cont ID  
Sent By rbrown Date 2002-10-11 Time 15:12 Rev Time 0.00
Received By rbrown Date 2002-10-11 Time 15:12 Sent To  
Notes
2002-10-11 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 --PROVISO--
 FBC 1007.5A HANDRAIL SHALL BE PROVIDED
 BETWEEN 34" AND 38" ABOVE THE LEADING
 EDGE OF THE TREADS ON THE NEW STAIRWAY.
  
 --PROVISO--
 FBC 2405.2IF THE NEW SHOWER ENCLOSURE
 IS TO INCORPORATE GLASS, IT IS REQUIRED
 TO BE SAFETY GLASS SATISFYING THE
 REQUIREMENTS OF THE CONSUMER PRODUCT
 SAFETY COMMISSION 16, CODE OF FEDERAL
 REGULATIONS, PART 1201 (CPSC 16-CFR,
 PART 1201).
  
 --PROVISO--
 FBC 1606.1.4BEFORE BUCK INSPECTION, A
 PRODUCT APPROVAL SHALL BE SUBMITTED FOR
 THE NEW FRENCH DOORS.
  
 --PROVISO--
 FBC 3401.7.2.4REPLACEMENT WINDOWS AND
 DOORS INSTALLED IN EXISTING BUILDINGS
 SHALL COMPLY WITH FBC 2001.AS THE
 PROPOSED WINDOWS ARE NOT IMPACT
 RESISTANT, IMPACT PROTECTION SHUTTERS
 SHALL BE INSTALLED AS REQUIRED BY THE
 SUBMITTED PRODUCT APPROVALS.A SEPARATE
 PERMIT APPLICATION (TO INCLUDE AN
 INSTALLATION SCHEDULE) WILL BE REQUIRED
 FOR THE SHUTTERS.
  
 --PROVISO--
 OUTSWING ALUMINUM CASEMENT WINDOW
 PRODUCT APPROVAL NOA# 01-0329.03.THE
 DRAWING SHEETS (IN PARTICULAR, SHEETS
 6 THRO' 10 OF 12) HAVE BEEN FAXED AND
 COPIED, AND CANNOT BE READ.SUBMIT TWO
 LEGIBLE COPIES BEFORE BUCK INSPECTION.
  
 --PROVISO--
 RECTANGULAR ALUMINUM FIXED WINDOW
 PRODUCT APPROVAL NOA# 01-0209.11.THE
 'PRODUCT DESCRIPTION'(SHEET 2, ITEM 2.1)
 STATES THAT THE WINDOW SHALL BE IN
 STRICT COMPLIANCE WITH DRAWING NO 97-001
 THIS WAS NOT SUBMITTED WITH THE PRODUCT
 APPROVAL. BEFORE BUCK INSPECTION, SUBMIT
 TWO COPIES OF THE STAMPED 'PRODUCT
 APPROVED' DRAWING NO. 97-001.
  
 --PROVISO--
 PRODUCT APPROVAL SUBMITTAL FORM FOR
 KINCO LIMITED ALUMINUM SINGLE HUNG
 WINDOW.BEFORE BUCK INSPECTION, THIS
 FORM SHALL BE MADE 'SITE SPECIFIC' BY
 HAVING ITEM 10.0 COMPLETED BY THE DESIGN
 PROFESSIONAL OF RECORD.AS THE BEEMS
 CONSTRUCTION PLAN HAS NOT BEEN PREPARED
 BY A REGISTERED ARCHITECT OR
 PROFESSIONAL ENGINEER, ITEM 10.0 MAY BE
 COMPLETED BY THE PROJECT ENGINEER
 (CAMERON MILLER, P.E) OR BY THE ENGINEER
 WHO COMPLETED THE CERTIFICATION IN
 ITEM 9.0 (HUMAYOU FAROOQ, P.E.).

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-03-05 Cont ID  
Sent By btrobaug Date 2003-03-05 Time 16:01 Rev Time 0.75
Received By btrobaug Date 2003-03-05 Time 15:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-09-16 Cont ID  
Sent By btrobaug Date 2002-09-16 Time 18:01 Rev Time 0.50
Received By btrobaug Date 2002-09-16 Time 17:28 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-09-16 Cont ID  
Sent By btrobaug Date 2002-09-16 Time 18:02 Rev Time 0.00
Received By btrobaug Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-09-16 Cont ID  
Sent By btrobaug Date 2002-09-16 Time 18:02 Rev Time 0.00
Received By btrobaug Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2002-10-11 Cont ID  
Sent By rbrown Date 2002-10-11 Time 15:55 Rev Time 0.00
Received By rbrown Date   Time   Sent To  
Notes
***NONE***