Plan Review Details - Permit 02090697
Plan Review Stops For Permit 02090697
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2003-06-05 Cont ID  
Sent By hpiskura Date 2003-06-05 Time 11:26 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2003-06-05 00:00:00REVISIONS DATED 4/16/03 ADT1 & SD5

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-05-02 Cont ID  
Sent By sthyng Date 2003-05-02 Time 17:19 Rev Time 2.00
Received By sthyng Date 2003-05-02 Time 17:19 Sent To  
Notes
2003-05-02 00:00:00PASSED PER BILL STAPLES
  
 SEE CBAA MINUTES APRIL 17, 2003 CASE
 NUMBER 1231, AND JANUARY 8, 2003 CASE
 NUMBER 1225.
  
 PRODUCT APPROVALS WITH 02090695

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-04-15 Cont ID  
Sent By hpiskura Date 2003-04-15 Time 12:18 Rev Time 0.00
Received By hpiskura Date 2003-04-15 Time 12:18 Sent To  
Notes
2003-04-15 00:00:00SEE COMMENTS ON 02090696

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-02-14 Cont ID  
Sent By hpiskura Date 2003-02-14 Time 10:34 Rev Time 0.00
Received By hpiskura Date 2003-02-14 Time 10:34 Sent To  
Notes
2003-02-14 00:00:00PLAN REVIEW COMMENTS ARE ATTACHED TO
 ROUTING SHEET. COMMENTS ARE SAME AS
 THOSE UNDER #02090695

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-10-17 Cont ID  
Sent By hpiskura Date 2002-10-17 Time 11:03 Rev Time 0.00
Received By hpiskura Date 2002-10-17 Time 10:41 Sent To  
Notes
2002-10-17 00:00:00THE COMMENTS ARE THE SAME AS REVIEW
 #02090696 AND ARE ATTACHED TO THIS
 APPLICATION FOR YOUR CONVENIENCE.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2003-08-21 Cont ID  
Sent By dpalmer Date 2003-08-21 Time 06:57 Rev Time 0.50
Received By dpalmer Date 2003-08-21 Time 06:57 Sent To  
Notes
2003-08-21 00:00:00************** UNSAT **************
  
 1)NOTE: PLEASE SEE THAT ALL LETTERS/PLAN
 -S MUST HAVE ORIGINAL SIGNATURE FROM
 THE ENGINEER OF RECORD.
 FS 471.025
 PLEASE ALSO NOTE; WE NEED LETTERS FOR
 EACH BLDG PERMIT.
  
 PLEASE SUBMIT THE ABOVE FOR REVIEW.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-04-11 Cont ID  
Sent By dpalmer Date 2003-04-11 Time 03:36 Rev Time 0.50
Received By dpalmer Date 2003-04-11 Time 03:36 Sent To  
Notes
2003-04-11 00:00:00ELECTRICAL PLANS STAMPED, READY FOR
 ISSUE.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-02-27 Cont ID  
Sent By dpalmer Date 2003-02-27 Time 06:13 Rev Time 0.25
Received By dpalmer Date 2003-02-27 Time 06:13 Sent To  
Notes
2003-02-27 00:00:00*************** UNSAT **************
  
 TYPE III
  
 PLEASE SEE FIRST REVIEW NOTES, SOME
 ARE THE SAME.
 PLEASE ALSO SEE NOTE UNDER 02090695.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-10-08 Cont ID  
Sent By dpalmer Date 2002-10-08 Time 07:48 Rev Time 1.00
Received By dpalmer Date 2002-10-08 Time 07:48 Sent To  
Notes
2002-10-08 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE SHOW INDICATION OF MAINS
 ON METER CENTERS FOR APTS.(RISER DIAGRAM
  
  
 2)NOTE: PLEASE NOTE, LOACK OFF DEVICES
 NEED TO BE RVIEWED BY THE CITY OF WEST
 PALM BEACH. DEVICE NEEDS TO BE A PART
 OF THE BREAKER AND NOT REMOVABLE.
 SOME DEVICES ARE NOT ACCEPTABLE AND
 PERMITTED TO BE INSTALLED. PLEASE NOTE
 ON PLANS.
  
 3)NOTE: PLEASE CLARIFY REQ`MENTS FOR
 FHAR 24 CFR 100.205
  
 4)NOTE: PLEASE SHOW LOCATION OF SERVICE
 RECEPT FOR A/C COND UNITS. 210-63
  
 5)NOTE: PLEASE CLARIFY METHOD OF EQUIP--
 MENT GROUNDING FOR "HOUSE" PANEL.
  
 6)NOTE: PLEASE NOTE INSTALLATION FOR
 CLOSET LLTS PER 410-8
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2003-02-10 Cont ID  
Sent By sjohnson Date 2002-10-16 Time 14:13 Rev Time 0.50
Received By mamini Date 2003-02-10 Time 08:45 Sent To  
Notes
2003-02-10 00:00:00PASSED:
 1. SEE PERMIT # 02121237 FOR UNDERGROUND
 UTILITIES AND SITE WORKS.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI
2002-10-16 00:00:00PER LUIS MARTINEZ

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-04-30 Cont ID  
Sent By nmccray Date 2003-04-30 Time 15:00 Rev Time 0.00
Received By nmccray Date 2003-04-30 Time 15:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2003-03-13 Cont ID  
Sent By nmccray Date 2003-03-13 Time 10:15 Rev Time 0.00
Received By nmccray Date 2003-03-13 Time 10:15 Sent To  
Notes
2003-03-13 00:00:001) SOME PLAN REVIEW COMMENTS HAVE NOT
 BEEN PROPERLY ADDRESSED.
  
 2) EXIT SIGNS REQUIRED AT FIRST FLOOR
 LEVEL.
  
 3) NFPA 13 SYSTEMS MUST BE USED WHEN
 CODE REQUIRMENTS HAVE BEEN ALTERED. NFPA
 13R SYSTEMS SHALL NOT BE USED.
  
 4) PLEASE INDICATE LOCATIONS OF FDC'S IN
 RELATION TO THE FIRE HYDRANTS. FDC'S SHA
 SHALL NOT EXCEED 150 FEET TO A FIRE
 HYDRANT.
  
 5) IT APPEARS THAT ADDITIONAL FIRE
 HYDRANTS ARE REQUIRED ON THE SITE PLAN.
 BETTER PLACEMENT WITH ADDITIONAL FIRE
 HYDRANTS WOULD APPEARS TO BE PROPER.
  
 NATE MCCRAY, CAPTAIN
 659-8096, EXT 8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-10-03 Cont ID  
Sent By mcarsill Date 2002-10-03 Time 15:12 Rev Time 0.00
Received By mcarsill Date 2002-10-03 Time 15:12 Sent To  
Notes
2002-10-03 00:00:001) PLEASE PROVIDE A LIFE SAFETY PLAN
 FOR THE BUILDING. PLEASE INDICATE EXIT
 SEPARATIONS, TRAVEL DISTANCES, ETC.
  
 2) NO FIRE SPRINKLER PLANS OR HYDRAULIC
 CALCULATIONS PROVIDED WITH PLANS.
  
 3) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE SPRINKLER SYSTEM.
  
 4) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE ALARM SYSTEM.
  
 5) WHAT PROVISIONS WILL BE MADE FOR
 FIRE AND PARAMEDICAL ACCESS THRU THE
 SECURITY GATES WHEN NORMAL POWER IS
 PRESENT. THIS OFFICE USUALLY REQUIRES
 A KNOX-BOX KEY SWITCH.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 16:48 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 16:48 Sent To P
Notes
2003-05-28 00:00:00KSTEVENS DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-05-07 Cont ID  
Sent By sthyng Date 2003-05-07 Time 15:30 Rev Time 0.00
Received By sthyng Date 2003-05-07 Time 15:30 Sent To P
Notes
2003-05-07 00:00:00TO PLUMB IN BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-29 Cont ID  
Sent By shernand Date 2003-04-29 Time 15:16 Rev Time 0.00
Received By shernand Date 2003-04-29 Time 15:16 Sent To P
Notes
2003-04-29 00:00:00KS DESK, PLUMBING REVISION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-03 Cont ID  
Sent By sgraham Date 2003-04-17 Time 16:26 Rev Time 0.00
Received By sthyng Date 2003-04-03 Time 08:59 Sent To  
Notes
2003-04-03 00:00:00COMM BOARD #42
 PLANS NEXT TO RACK, 3 ROLLS
 COVER SHEET SENT TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-10 Cont ID  
Sent By sgraham Date 2003-02-11 Time 08:58 Rev Time 0.00
Received By dpalmer Date 2003-02-10 Time 08:44 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2003-05-01 Cont ID  
Sent By pkrauss Date 2003-05-01 Time 16:15 Rev Time 0.40
Received By pkrauss Date 2003-05-01 Time 16:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2003-04-25 Cont ID  
Sent By pkrauss Date 2003-04-25 Time 09:39 Rev Time 1.15
Received By pkrauss Date 2003-04-25 Time 09:39 Sent To  
Notes
2003-04-25 00:00:00AS PER CONVERSATION WITH PAUL EDERLE
 (3-25-03), CONTRACTOR TO BRING IN
 UPDATED SHEETS AND RE-ORGANIZE PLANS
 ON 4-28-03.
  
 1 SET OF PLANS ARE COMPLETE & IN ORDER.
  
 1 SET OF PLANS ARE APPROVED BUT PLANS
 ARE NOT IN ORDER FP1 THRU 6 IS INSERTED
 IN THE MIDDLE OF MECHANICAL PLANS.
 PLEASE RE-ORGANIZE.
  
 1 SET PLANS NEED SHEETS AC-U1 THRU U4
 REPLACED WITH REVISED SHEETS DATED
 3/25/03.ALL SHEETS IN THE SET ARE
 OKAY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-02-20 Cont ID  
Sent By pkrauss Date 2003-02-19 Time 16:03 Rev Time 0.40
Received By pkrauss Date 2003-02-19 Time 16:03 Sent To  
Notes
2003-02-19 00:00:00DENIED:
 ITEMS NOT ADDRESSED ON REVIEW BY HAROLD
 MOSERR DATED 10/08/02.
 1.VERIFY OUTSIDE AIR REQUIREMENTS.
 INDICATE CALCULATIONS FOR NATURAL
 (2001 FBC(M) 402.2) OR MECHANICAL (2001
 FBC(M) TABLE 403.3).
  
 2.DUCTS EXTENDING MORE THAN 1 FLOOR
 ARE REQUIRED TO BE ENCLOSED BY A SHAFT
 ENCLOSURE AS PER 2001 FBC(M) 607.4.
 PROVIDE DETAIL OF UL SHAFT ASSEMBLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-10-08 Cont ID  
Sent By hmoser Date 2002-10-08 Time 16:44 Rev Time 1.00
Received By hmoser Date 2002-10-08 Time 16:44 Sent To  
Notes
2002-10-08 00:00:00PLAN DENIED
 1) VARIFY TYPE VENTILATION USED FOR
 FRESH AIR.SECTION 402 NATURAL OR
 403 MECHANICAL VENTILATION FBC(M)2001
 2) NEED MANUFACTURERS INSTALLATION
 INSTRUCTIONS ON CLOTHES DRYER
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 6 Status P Date 2003-05-28 Cont ID  
Sent By kstevens Date 2003-05-28 Time 18:31 Rev Time 0.33
Received By kstevens Date 2003-05-28 Time 18:31 Sent To  
Notes
2003-05-28 00:00:00REVISION OK, REROUTE SANT. & WATER LINES

Review Stop P PLUMBING
Rev No 5 Status F Date 2003-05-19 Cont ID  
Sent By shernand Date 2003-05-28 Time 16:49 Rev Time 1.50
Received By kstevens Date 2003-05-14 Time 14:09 Sent To  
Notes
2003-05-14 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) CLEANOUTS ARE REQUIRED ON BLDG DRAIN
 AT ALL BREEZWAYS.
 2) FULL OPEN VALVE REQUIRED AT ENTRANCE
 OF STRUCTURE. SEC 606.1(1)
 3) FULL OPEN VALVE REQUIRED AT BASE OF
 EACH WATER RISER. SEC 606.1(2)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 4 Status N Date 2003-05-05 Cont ID  
Sent By sthyng Date 2003-05-07 Time 15:30 Rev Time 0.50
Received By pschmitz Date   Time   Sent To  
Notes
2003-05-02 00:00:00NEW PLAN REVIEW REQ, PES.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-04-12 Cont ID  
Sent By shernand Date 2003-04-29 Time 15:18 Rev Time 0.50
Received By kstevens Date 2003-04-12 Time 13:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-03-04 Cont ID  
Sent By kstevens Date 2003-03-04 Time 17:51 Rev Time 0.50
Received By kstevens Date 2003-03-04 Time 17:51 Sent To  
Notes
2003-03-04 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) WATER HEATER P/T FROM 2ND AND 3RD
 FLOORS SHALL DRAIN THRU CEILING OF THE
 FIRST FLOOR AND STUB OUT 6" ABOVE GRADE.
 HEATER PANS ARE NOT APPROVED INDIRECT
 WASTE RECEPTORS. FIRST FLOOR P/T CAN
 DRAIN TO FLOOR.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-10-05 Cont ID  
Sent By kstevens Date 2002-10-05 Time 12:06 Rev Time 0.00
Received By kstevens Date 2002-10-05 Time 12:06 Sent To  
Notes
2002-10-05 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) SHTS P-U1, P-U2, P-U3, & P-U4 WATER
 RISER DIAGRAMS, WATER HAMMER ARRESTORS
 AT WASHMACHINES TO BE LOCATED NEAR FIX-
 TURES IN AN "EFFECTIVE RANGE" NOT AT THE
 TOP OF THE DROP AS SHOWN.
 2) SHT P-T1.1 CLEAN OUT REQUIRED IN THE
 BREEZE WAY TO THE LEFT OF WHERE BLDG.
 DRAIN ENTERS THE BLDG. SEC 708.3.1
 3) SHT P-T1.3 SANITARY RISER DIAGRAM,
 SEE PREVIOUS COMMENT (#2).
 4) SHT PD-1 WATER HEATER PAN DRAIN & T/P
 RELIEF RISERS, T/P RELIEF LINE SHALL NOT
 BE TRAPPED. SEC 504.7.1
 5) SHT PD-1 PLUMBING GENERAL NOTES #6,
 DIELECTRIC UNIONS ARE NOT APPROVED FOR
 WATER. PLEASE DELETE REFERENCE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 3 Status P Date 2003-04-17 Cont ID  
Sent By sgraham Date 2003-04-17 Time 16:26 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2003-02-11 Cont ID  
Sent By sgraham Date 2003-02-11 Time 08:57 Rev Time 0.00
Received By sgraham Date 2003-02-11 Time 08:58 Sent To I
Notes
2003-02-11 00:00:00DENIED, NEED TO AMEND PLANS TO MATCH
 APPROVED SITE PLAN- SENT TO BLDG

Review Stop Z ZONING
Rev No 1 Status F Date 2002-09-24 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 08:44 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-09-24 00:00:00DENIED, NEED CITY COMMISSION APPROVAL