| Plan Review Stops For Permit 02090696 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-06-05 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-06-05 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-05 00:00:00 | REVISIONS DATED 4/16/03 ADT1 & SD5 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-05-02 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-02 |
Time |
12:22 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-05-02 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2003-05-02 00:00:00 | PASSED PER BILL STAPLES | | | | | | SEE CONSTRUCTION BOARD OF ADJUSTMENT | | | AND APPEALS MINUTES, APRIL 17, 2003 CASE | | | NUMBER 1231, AND JANUARY 8, 2003 CASE | | | NUMBER 1225. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-15 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-15 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | THIRD PAID PLAN REVIEW NOT A PERMIT | | | APPLICATION. | | | | | | THE FIRE PROTECTION PLANS MUST ACCOMPANY | | | THE PERMIT PLANS. SEE FBC 104.3.1.1 #5. | | | | | | THE CONSTUCTION BOARD OF ADJUSTMENT AND | | | APPEALS CASE #1225 HEARD 1/8/03 GRANTED | | | A VARIANCE TO THE 50% LONG SIDE OPEN | | | BALCONY REQUIREMENT OF FBC 1014.1.1. | | | | | | FIRE SPRINKLERS INSTALLED AS A CODE | | | REQUIREMENT MUST BE A NFPA 13 SYSTEM. | | | SEE FBC 903.2. | | | | | | THE EXITS DO NOT MEET THE 1/2 DIAGONAL | | | DISTANCE SEPARATION REQUIREMENTS OF FBC | | | 1006.2.2. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-02-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-14 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-14 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2003-02-14 00:00:00 | COMMENTS ARE ATTACHED TO THE REVIEW | | | SHEET AND ARE CONTAINED UNDER REVIEW | | | #020695 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-10-02 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-10-01 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2002-10-02 00:00:00 | PAID PLAN REVIEW NOT A PERMIT | | | APPLICATION. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO THE | | | COUNTY, THE PERMIT PLANS STAMPED BY | | | THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. | | | | | | ON PROJECTS OF THIS SCOPE THE BUILDING | | | OFFICIAL WILL REQUIRE A RESIDENT | | | INSPECTOR.CONTACT DON NEELY, | | | 561-659-8096 X 8333, FOR MORE | | | INFORMATION. | | | | | | AT TIME OF PERMIT APPLICATION, IF THE | | | TEST AND OR NOTICE OF ACCEPTANCE | | | REPORTS, FOR THE WINDOWS, DOORS AND | | | ROOF COVERING ARE NOT INCLUDED, SEPARATE | | | PERMITS AND FEES WILL BE REQUIRED. | | | | | | SHEET AS-1 DECLARES 13,864 SQUARE FEET | | | FOR A TYPE III BUILDING AND SHEET | | | A-T3.1 16,016.PLEASE CLARIFY.SEE | | | FBC 202, "AREA, BUILDING" | | | | | | THE DETAIL 17/A-DT2 DOES NOT AGREE WITH | | | FBC FIGURE 709.5.1C FOR THE ONE HOUR | | | FIRE RATED COLUMN. | | | | | | THE NOTES ON SHEET A-DT1 DECLARE THE USE | | | OF HURRICANE SHUTTERS.SEE THE | | | BUILDING OFFICIAL'S POLICY STATEMENT | | | ATTACHED.HURRICANE MISSILE IMPACT | | | RESISTANT GLAZING IS REQUIRED | | | THROUGHOUT. | | | | | | THE DROPPED SOFFIT DETAIL 14/ADT-2 NEEDS | | | SPECIFIC FRAMING AND FASTENER DETAILS. | | | SEE FBC 104.2. | | | | | | NOTE #3 ON SHEET SD-4 DECLARES DESIGN TO | | | THE 1997 SBC AND 110 MPH.PLEASE | | | REVISE AND INSURE COMPLIANCE WITH FBC | | | 1606 FOR 140 MPH WIND ZONE. | | | | | | SHOW THE FIRE PROTECTION DESIGN | | | INFORMATION.SEE FBC 104.2. | | | | | | THE EXIT STAIRS ARE REQUIRED TO BE | | | ENCLOSED IN FIRE RATED CONSTRUCTION IN | | | ACCORDANCE WITH FBC 1006.1 OR COMPLY | | | WITH FBC 1006.2 FOR EXTERIOR STAIRS. | | | AS DEPICTED ON THESE PLANS THEY COMPLY | | | WITH NEITHER. | | | | | | THE THIRD FLOOR REQUIRES TWO INDEPENDENT | | | MEANS OF EGRESS.SEE FBC 1004.2.1. | | | | | | SHEET SD-5 HAS INCORRECTLY LABELED | | | ROOF CORNER ZONES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-11 |
Time |
03:57 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-11 |
Time |
03:38 |
Sent To |
|
|
| Notes |
| 2003-04-11 00:00:00 | ELECTRICAL PLANS STAMPED, READY TO | | | ISSUE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-27 |
Time |
06:03 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-02-27 |
Time |
06:03 |
Sent To |
|
|
| Notes |
| 2003-02-27 00:00:00 | ************** UNSAT **************** | | | | | | TYPE II | | | | | | PLEASE SEE NOTES FROM FIRST REVIEW. | | | PLEASE SEE NOTES UNDER PERMIT # 02090695 | | | | | | | | | IF THERE ARE ANY QUESTIONS,PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-08 |
Time |
05:26 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-10-08 |
Time |
05:26 |
Sent To |
|
|
| Notes |
| 2002-10-08 00:00:00 | ****************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE, AS PER NOTE #7 ON | | | E-U1. THE LOCK OFF DEVICE MUST BE | | | A PART OF THE BREAKER. PLEASE NOTE THE | | | TYPE OF LOCK OFF DEVICE CHOSEN NEEDS TO | | | BE REVIEWED BY THE CITY OF WEST PALM | | | BEACH BEFORE INSTALLATION. PLEASE NOTE, | | | MOST OF THE "SNAP ON" DEVICES ARE NOT | | | PERMITTED TO BE USED AND A MEANS OF DISC | | | IS REQ`D. PLEASE NOTE ON PLANS. | | | | | | 2)NOTE: PLEASE SHOW REQ`MENTS FOR FAIR | | | HOUSING ACT. FHAR 24 CFR 100.205. | | | | | | 3)NOTE: PLEASE NOTE CLEARENCE FOR CLOSET | | | LIGHT INSTALLATION PER 410-8. | | | | | | 4)NOTE: PLEASE CLARIFY LOCATION OF | | | SERVICE RECEPT FOR A/C COND UNIT. 210-63 | | | | | | 5)NOTE: PLEASE SEE 230-72 FOR GROUPING | | | OF MAINS . PLEASE NOTE A SHUNT TRIP | | | MAY NOT BE USED FOR GROUPING OF MAINS. | | | PLEASE SEE 230-76,230-79. | | | PLEASE CLARIFY HOW THIS MEETS 230-2 | | | AND THE ABOVE. | | | | | | 6)NOTE: PLEASE CLARIFY METHOD OF EQUIP- | | | -MENT GROUNDIG BETWEEN METER/MAIN AND | | | HOUSE PANEL? SIZE PER 250-122 | | | | | | 7)NOTE: PLEASE SHOW INDICATION OF MAINS | | | FOR APT UNITS ON RISER DIAGRAM. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
sjohnson |
Date |
2002-10-16 |
Time |
14:12 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-02-10 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2003-02-10 00:00:00 | PASSED: | | | 1. SEE PERMIT # 02121237 FOR UNDERGROUND | | | UTILITIES AND SITE WORKS. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI | | 2002-10-16 00:00:00 | PER LUIS MARTINEZ |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-30 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-30 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-03-06 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-03-06 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2003-03-06 00:00:00 | 1) SOME PLAN REVIEW COMMENTS HAVE | | | NOT BEEN PROPERLY ADDRESSED. | | | | | | 2) EXIT SIGNS REQUIRED AT FIRST FLOOR | | | LEVEL. | | | | | | 3) IT APPEARS THAT ADDITIONAL FIRE | | | HYDRANTS ARE REQUIRED ON THE SITE PLAN. | | | BETTER PLACEMENT WITH ADDITIONAL FIRE | | | HYDRANTS WOULD APPEAR TO BE PROPER. | | | | | | 4) PLEASE INDICATE LOCATIONS OF FDC'S | | | IN RELATION TO THE FIRE HYDRANTS. FDC'S | | | SHALL NOT EXCEED 150 FEET TO A FIRE | | | HYDRANT. | | | | | | 5) NFPA 13R SYSTEMS SHALL NOT BE USED | | | WHEN CODE REQUIREMENTS HAVE BEEN | | | ALTERED. NFPA 13 SYSTEMS MUST BE USED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-10-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-10-04 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-10-04 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2002-10-04 00:00:00 | 1) PLEASE PROVIDE A LIFE SAFETY PLAN | | | FOR THE BUILDING. PLEASE INDICATE | | | EXIT SEPARATIONS, TRAVEL DISTANCES, | | | ETC. | | | | | | 2) NO FIRE SPRINKLER PLANS OR HYDRAULIC | | | CALCULATIONS PROVIDED WITH PLANS. | | | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER SYSTEM. | | | | | | 4) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM. | | | | | | 5) WHAT PROVISIONS WILL BE MADE FOR | | | FIRE AND PARAMEDICAL ACCESS THRU THE | | | SECURITY GATES WHEN NORMAL POWER IS | | | PRESENT. THIS OFFICE USUALLY REQUIRES | | | A KNOX-BOX KEY SWITCH. WHAT HAPPENS | | | WHEN LOSS OF POWER OCCURS. | | | | | | 6) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING AND AFTER CONSTRUCTION. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-05-28 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-28 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-28 |
Time |
16:49 |
Sent To |
P |
|
| Notes |
| 2003-05-28 00:00:00 | KSTEVENS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-05-07 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-07 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-05-07 |
Time |
15:25 |
Sent To |
P |
|
| Notes |
| 2003-05-07 00:00:00 | TO PLUMB IN BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-29 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-29 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-29 |
Time |
15:17 |
Sent To |
P |
|
| Notes |
| 2003-04-29 00:00:00 | KSTEVENS DESK, PLUMBING REVISION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-17 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-03 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | COMM BOARD #42 | | | PLANS NEXT TO RACK | | | COVER SHEET SENT TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-11 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-10 |
Time |
08:43 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-05-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-01 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2003-05-01 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2003-05-01 00:00:00 | PLANS APPROVED 4-4-24 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-02-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-19 |
Time |
15:45 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-02-19 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2003-02-19 00:00:00 | DENIED: | | | ITEMS NOT ADDRESSED ON REVIEW BY HAROLD | | | MOSER DATAED 10/08/02. | | | 1.VERIFY OUTSIDE AIR REQUIREMENTS. | | | INDICATE CALCULATIONS FOR NATURAL | | | (2001 FBC(M) 402.2) OR MECHANICAL (2001 | | | FBC(M) TABLE 403.3). | | | | | | 2.DUCTS EXTENDING MORE THAN 1 FLOOR | | | ARE REQUIRED TO BE ENCLOSED BY A SHAFT | | | ENCLOSURE AS PER 2001 FBC(M) 607.4. | | | PROVIDE DETAIL OF UL SHAFT ASSEMBLY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-10-08 |
Time |
17:57 |
Rev Time |
1.00 |
| Received By |
hmoser |
Date |
2002-10-08 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2002-10-08 00:00:00 | PLAN/DENIED | | | 1) VARIFY TYPE OF VENTILATION USED FOR | | | FRESH AIR.SECTION 402 NATURAL OR | | | MECHANICAL SECTION 403.IF SECTION 402 | | | IS USED YOU NEED CALCULATIONS. | | | 2) NEED MANUFACTURERS INSTALLATION | | | INSERUCTIONS ON CLOTHES DRYER | | | 3) MISSING DUCT SIZE ON UNIOT C2-P 1ST | | | FLOOR | | | 4) REFER TO SECTION 306.1.1 CLEARANCE | | | AROUND AIRHANDLER | | | 5) REFER TO SECTION 304.9 AREA SERVED. | | | ALL IN FLORIDA BUILDING CODE | | | MECHANICAL 2001 | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2003-05-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-28 |
Time |
18:22 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-05-28 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2003-05-28 00:00:00 | REVISION OK, SANT./WATER REROUTED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-28 |
Time |
16:49 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-05-19 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) FULL OPEN VALVE REQUIRED AT ENTRANCE | | | OF STRUCTURE. SEC 606.1(1) | | | 2) FULL OPEN VALVES REQUIRED AT THE BASE | | | OF EACH WATER RISER. 606.1(2) | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-07 |
Time |
15:25 |
Rev Time |
0.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-02 00:00:00 | NEW PLAN REVIEW REQ, PES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-12 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-29 |
Time |
15:17 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-04-12 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-04 |
Time |
17:38 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-03-04 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2003-03-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) WATER HEATER PAN IS NOT AN APPROVED | | | INDIRECT WASTE RECEPTOR. P/T FROM 2ND & | | | 3RD FLOOR WATER HEATERS CAN RUN IN THE | | | CEILING OF THE FIRST FLOOR AND STUB OUT | | | 6" ABOVE GRADE. FIRST FLOOR P/T CAN | | | DRAIN TO FLOOR. | | | 2) C/O REQUIRED IN BREEZEWAY TO THE | | | RIGHT OF BLDG DRAIN AS IT ENTERS THE | | | BLDG. 120' BETWEEN C/O'S | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-10-05 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-10-05 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2002-10-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SHTS P-U1, P-U2, P-U3, P-U4, P-U5, & | | | P-U6, WATER RISER DIAGRAMS, WATER HAMMER | | | ARRESTORS AT WASH MACHINES SHALL BE LO- | | | CATED NEAR THE FIXTURES IN AN "EFFECTIVE | | | RANGE" NOT AT THE TOP OF DROPS AS SHOWN. | | | PDI-WH 201 AND MANUFACTURE INSTALLATION | | | INSTRUCTIONS. 604.9 | | | 2) SHT P-T3.1 CLEAN OUTS SHALL BE RE- | | | QUIRED IN EACH BREEZE WAY. 100' MAX BE- | | | TWEEN C/O'S SEC 708.3.1 | | | 3) SHT P-T3.3 SANITARY RISER DIAGRAM, | | | SEE PREVIOUS COMMENT. (#2) | | | 4) SHT PD-1 WATER HEATER DRAIN & P/T RE- | | | LIEF RISERS. T/P LINE SHALL NOT BE TRAP- | | | PED SEC 504.7.1 | | | 5) SHT PD-1 PLUMBING GENERAL NOTES #6, | | | DIELECTRIC UNIONS NOT APPROVED FOR WATER | | | LINES. PLEASE DELETE REFERENCE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-17 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-11 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-02-11 00:00:00 | DENIED, NEED TO AMEND PLANS TO MATCH | | | APPROVED SITE PLAN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-10 |
Time |
08:43 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-09-24 00:00:00 | DENIED, NEED CITY COMMISSION APPROVAL |
|
|