Plan Review Details - Permit 02090695
Plan Review Stops For Permit 02090695
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2003-06-05 Cont ID  
Sent By hpiskura Date 2003-06-05 Time 10:46 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2003-06-05 00:00:00REVISON DATED 4/16/03 ADT1 & SD5

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-05-02 Cont ID  
Sent By shernand Date 2003-06-03 Time 10:13 Rev Time 1.00
Received By sthyng Date 2003-05-02 Time 12:25 Sent To  
Notes
2003-05-02 00:00:00PASSED PER BILL STAPLES
  
  
 SEE CONSTRUCTION BOARD OF ADJUSTMENT
 AND APPEALS MINUTES, JANUARY 8, 2003
 CASE #1225, AND APRIL 17, 2003 CASE
 #1231.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-04-15 Cont ID  
Sent By hpiskura Date 2003-04-15 Time 12:19 Rev Time 0.00
Received By hpiskura Date 2003-04-15 Time 12:19 Sent To  
Notes
2003-04-15 00:00:00SEE COMMENTS 02090696

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-02-14 Cont ID  
Sent By hpiskura Date 2003-02-13 Time 15:54 Rev Time 0.00
Received By hpiskura Date 2003-02-13 Time 07:46 Sent To  
Notes
2003-02-13 00:00:00PAID PLAN REVIEW NOT A PERMIT
 APPLICATION.
  
 THE COMMENTS PROVIDED IN THE 10/02/02
 LIST REGARDING IMPACT FEES, RESIDENT
 INSPECTOR, PRODUCT REPORTS, ETC. ARE
 THE SAME AND STILL APPLICABLE.
  
 SHEET SD4 STILL CONTAINS DESIGN
 INFORMTION AS BEING 1997 SBC AND 110
 MPH.SD5 MAKES REFERENCE TO THE HVHZ
 AND FBC 1606.2.THE CITY OF WEST PALM
 BEACH IS UNDER THE 2001 FLORIDA
 BUILDING CODE AND IS IN THE 140 MPH
 WIND ZONE.CLEARLY NOTE IF ASCE 7-98
 CHAPTER 6 OR FBC 1606.2 WAS USED FOR
 THE DESIGN, IN ADDITION OR IN PLACE OF
 THE SEVERAL CODES AND STANDARDS CITED
 ON THE PLANS.
  
 THERE ARE STILL TWO INDEPENDENT EXITS
 REQUIRED BY FBC 1004.2.1 FOR THE SECOND
 AND THIRD LEVELS.
  
 THE EXIT CONFIGURATION SHOWN DOES NOT
 COMPLY WITH FBC 1006.1 FOR ENCLOSED
 STAIRS OR 1006.2 FOR EXTERIOR STAIRS.
  
 THESE COMMENTS APPLY TO BUILDINGS TYPE
 I, II, AND III, AND ARE NOT REPEATED ON
 THOSE PLAN REVIEWS NUMBERS 02090696 AND
 02090697.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-10-17 Cont ID  
Sent By hpiskura Date 2002-10-17 Time 10:20 Rev Time 0.00
Received By hpiskura Date 2002-10-16 Time 15:15 Sent To  
Notes
2002-10-17 00:00:00THE COMMENTS ARE THE SAME AS REVIEW
 #02090696, A COPY OF WHICH HAS BEEN
 ATTACHED TO THE APPLICATION SHEET FOR
 YOUR CONVIENCE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-04-11 Cont ID  
Sent By dpalmer Date 2003-04-11 Time 03:03 Rev Time 0.75
Received By dpalmer Date 2003-04-11 Time 03:03 Sent To  
Notes
2003-04-11 00:00:00ELECTRICAL SHEETS STAMPED, READY FOR
 ISSUE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-02-26 Cont ID  
Sent By dpalmer Date 2003-02-26 Time 18:34 Rev Time 0.75
Received By dpalmer Date 2003-02-26 Time 18:34 Sent To  
Notes
2003-02-26 00:00:00********* UNSAT **************
  
 1)NOTE: PLEASE REMOVE SHEETS NOT
 PERTAINING TO THIS BLDG. PLEASE SEE
 TRASH COMPACTOR RISER?
  
 2)NOTE: PLEASE SEE A COUPLE OF NOTES
 FROM FIRST REVIEW.
 PLEASE PROVIDE NOTE FOR "LOCK OFF"
 DEVICE NEEDS TO BE REVIEWED BY THE
 CITY OF WEST PALM BEACH BEFORE
 INSTALLATION, A DISC MAY BE REQ`D.
 MOST "SNAP ON " DEVICES ARE NOT
 PERMIITED.
 3)NOTE: PLEASE SEE LOAD SHOWN FOR RANGE,
 PLEASE CLARIFY 12KW LOAD AT 70% IS 5.6?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-10-08 Cont ID  
Sent By dpalmer Date 2002-10-08 Time 06:23 Rev Time 1.00
Received By dpalmer Date 2002-10-08 Time 06:23 Sent To  
Notes
2002-10-08 00:00:00***************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE, AS PER NOTE #7 ON
 E-SHEETS, THE LOCK OFF DEVICE MUST BE
 A PART OF THE BREAKER. PLEASE NOTE THE
 TYPE OF LOCK OFF DEVICE CHOSEN NEEDS TO
 BE REVIEWED BY THE CITY OF WETS PALM
 BEACH BEFORE INSTALLATION. PLEASE NOTE,
 MOST OF THE " SNAP ON" DEVICES ARE NOT
 PERMITTED TO BE USED AND A MEANS OF
 DISC IS REQ`D. PLEASE NOTE ON PLANS.
  
 2)NOTE: PLEASE SHOW REQ`MENTS FOR FAIR
 HOUSING ACT. FHAR 24 CFR 100.205.
  
 3)NOTE: PLEASE NOTE CLEARENCE FOR CLOSET
 LIGHT INSTALLATIONPER 410-8.
  
 4)NOTE: PLEASE CLARIFY LOCATION OF REC
 FOR A/C COND UNITS PER 210-63.
  
 5)NOTE: PLEASE CLARIFY GROUPING OF MAINS
 PER 230-72. PLEASE NOTE HAVING THE SHUNT
 TRIPS DO NOT MEET THE REQUIREMENTS OF
 GROUPING. PLEASE NOTE SHUNTS DO NOT
 MEET 230-76,230-79.
 PLEASE CLARIFY HOW THE SECOND SERVICE
 MEETS 230-2.
  
 6)NOTE: MISSING EQUIPMENT GROUNDING
 CONDUCTOR BETWEEN MAIN AND HOUSE PANEL?
 SIZEPER 250-122
  
 7)NOTE: PLEASE INDICATE MAINS FOR APT
 MAINS ON RISER DIAGRAM. 215-5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2003-02-10 Cont ID  
Sent By sjohnson Date 2002-10-16 Time 14:12 Rev Time 0.50
Received By mamini Date 2003-02-10 Time 08:59 Sent To  
Notes
2003-02-10 00:00:00PASSED:
 1. SEE PERMIT # 02121237 FOR UNDERGROUND
 UTILITIES AND SITE WORK.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI
2002-10-16 00:00:00PER LUIS MARTINEZ

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-04-30 Cont ID  
Sent By nmccray Date 2003-04-30 Time 15:02 Rev Time 0.00
Received By nmccray Date 2003-04-30 Time 15:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2003-03-06 Cont ID  
Sent By mcarsill Date 2003-03-06 Time 11:16 Rev Time 0.00
Received By mcarsill Date 2003-03-06 Time 11:16 Sent To  
Notes
2003-03-06 00:00:001) SOME PLAN REVIEW COMMENTS HAVE NOT
 BEEN PROPERLY ADDRESSED.
  
 2) EXIT SIGNS REQUIRED AT FIRST FLOOR
 LEVEL.
  
 3) IT APPEARS THAT ADDITIONAL FIRE
 HYDRANTS ARE REQUIRED ON THE SITE PLAN.
 BETTER PLACEMENT WITH ADDITONAL FIRE
 HYDRANTS WOULD APPEAR TO BE PROPER.
  
 4) PLEASE INDICATE LOCATIONS OF FDC'S
 IN RELATION TO THE FIRE HYDRANTS. FDC'S
 SHALL NOT EXCEED 150 FEET TO A FIRE
 HYDRANT.
  
 5) NFPA 13R SYSTEMS SHALL NOT BE USED
 WHEN CODE REQUIREMNTS HAVE BEEN
 ALTERED. NFPA 13 SYSTEMS MUST BE
 USED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-10-04 Cont ID  
Sent By mcarsill Date 2002-10-04 Time 16:29 Rev Time 0.00
Received By mcarsill Date 2002-10-04 Time 16:28 Sent To  
Notes
2002-10-04 00:00:001) PLEASE PROVIDE A LIFE SAFETY PLAN FOR
 THE BUILDING. PLEASE INDICATE EXIT
 SEPARATIONS, TRAVEL DISTANCES, ETC.
  
 2) NO FIRE SPRINKLER PLANS OR HYDRAULIC
 CALCULATIONS PROVIDED WITH PLANS.
  
 3) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE SPRINKLER SYSTEM.
  
 4) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE ALARM SYSTEM.
  
 5) WHAT PROVISIONS WILL BE MADE FOR FIRE
 AND PARAMEDICAL ACCESS THRU THE SECURITY
 GATES WHEN NORMAL POWER IS PRESENT. THIS
 OFFICE USUALLY REQUIRES A KNOX-BOX KEY
 SWITCH.
  
 6) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2003-11-26 Cont ID  
Sent By csiegber Date 2003-11-26 Time 16:41 Rev Time 0.00
Received By csiegber Date 2003-11-26 Time 16:41 Sent To  
Notes
2003-11-26 00:00:00TO COMM BD#

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-06-03 Cont ID  
Sent By shernand Date 2003-06-03 Time 10:12 Rev Time 0.00
Received By shernand Date 2003-06-03 Time 10:12 Sent To B
Notes
2003-06-03 00:00:00HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 16:49 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 16:49 Sent To P
Notes
2003-05-28 00:00:00KSTEVENS DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-05-09 Cont ID  
Sent By shernand Date 2003-05-09 Time 11:54 Rev Time 0.00
Received By shernand Date 2003-05-09 Time 11:54 Sent To  
Notes
2003-05-09 00:00:00ON RACK, DO NOT PROCESS UNTIL FINAL
 PLUMBING REVIEW.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-05-07 Cont ID  
Sent By sthyng Date 2003-05-07 Time 15:29 Rev Time 0.00
Received By sthyng Date 2003-05-07 Time 15:29 Sent To P
Notes
2003-05-07 00:00:00TO PLUMB IN BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-29 Cont ID  
Sent By shernand Date 2003-04-29 Time 15:19 Rev Time 0.00
Received By shernand Date 2003-04-29 Time 15:19 Sent To P
Notes
2003-04-29 00:00:00KSTEVENS DESK.PLUMBING REVISION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-03 Cont ID  
Sent By sgraham Date 2003-04-17 Time 16:25 Rev Time 0.00
Received By sthyng Date 2003-04-03 Time 08:45 Sent To  
Notes
2003-04-03 00:00:00TO COMM BOARD #42
 NEXT TO RACK, 3 ROLLS
 SENT COVER SHEET TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-10 Cont ID  
Sent By sgraham Date 2003-02-11 Time 09:42 Rev Time 0.00
Received By dpalmer Date 2003-02-10 Time 08:42 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-04-24 Cont ID  
Sent By pkrauss Date 2003-04-24 Time 15:38 Rev Time 1.00
Received By pkrauss Date 2003-04-24 Time 15:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-02-19 Cont ID  
Sent By pkrauss Date 2003-02-19 Time 14:23 Rev Time 0.40
Received By pkrauss Date 2003-02-19 Time 14:13 Sent To  
Notes
2003-02-19 00:00:00DENIED:TYPE I
 ITEMS NOT ADDRESSED ON REVIEW BY HAROLD
 MOSER DATED 10/08/02.
 1.VERIFY OUTSIDE AIR REQUIREMENTS.
 INDICATE CALCULATIONS FOR NATURAL
 (2001 FBC(M) 402.2.) OR MECHANICAL
 (2001 FBC(M) TABLE 403.3).
  
 2.DUCTS EXTENDING MORE THAN 1 FLOOR
 ARE REQUIRED TO BE ENCLOSED BY A SHAFT
 ENCLOSURE AS PER 2001 FBC(M) 607.4.
 PROVIDE DETAIL OF UL SHAFT ASSEMBLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-10-08 Cont ID  
Sent By hmoser Date 2002-10-08 Time 19:23 Rev Time 1.00
Received By hmoser Date 2002-10-08 Time 19:22 Sent To  
Notes
2002-10-08 00:00:00PLAN DENIED
 1) VARIFY TYPE OF VENTILATION USED FOR
 FRESH AIR.SECTION 402 NATURAL OR
 MECHANICAL SECTION 403 FBC.2001
 2) NEED CALCULATIONS FOR TYPE OF
 VEVTILATION USED
 3) NEED MANUFACTURERS INSTALLATION ON
 CLOTHES DRYER
 4) REFER TO SECTION 306.1.1 CLEARANCE
 AROUND AIRHANDLER
 5) CAN NOT RUN DRYER VENT AND BATHROOM
 EXHAUST IN SAME CHASE
 6) REFER TO SECTION 401.6 BATHROOM
 EXHAUST WALL CAP MUST HAVE SCREEN.
 BACKDRAFT DAMPER ON FAN ONLEY
 7) NEED ENERGY CALCS & MANUAL (J)
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 6 Status P Date 2003-05-28 Cont ID  
Sent By kstevens Date 2003-05-28 Time 18:07 Rev Time 0.33
Received By kstevens Date 2003-05-28 Time 18:07 Sent To  
Notes
2003-05-28 00:00:00REVISION OK, REROUTE SANT. & WATER LINES

Review Stop P PLUMBING
Rev No 5 Status F Date 2003-05-19 Cont ID  
Sent By shernand Date 2003-05-28 Time 16:49 Rev Time 1.50
Received By kstevens Date 2003-05-19 Time 09:35 Sent To  
Notes
2003-05-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) FULL OPEN VALVE REQUIRED AT ENTRANCE
 OF STRUCTURE. 606.1(1)
 2) FULL OPEN VALVES REQUIRED AT BASE OF
 EACH WATER RISER. 606.1(2)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 4 Status N Date 2003-05-05 Cont ID  
Sent By sthyng Date 2003-05-07 Time 15:29 Rev Time 0.75
Received By pschmitz Date   Time   Sent To  
Notes
2003-05-05 00:00:0005-02-03 REVISION, NEW PLAN REVIEW
 REQUIRED, PES.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-04-12 Cont ID  
Sent By shernand Date 2003-04-29 Time 15:19 Rev Time 0.50
Received By kstevens Date 2003-04-12 Time 13:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-03-04 Cont ID  
Sent By kstevens Date 2003-03-04 Time 17:33 Rev Time 0.33
Received By kstevens Date 2003-03-04 Time 17:06 Sent To  
Notes
2003-03-04 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) WATER HEATER PAN DRAINS ARE NOT
 APPROVED INDIRECT WASTE RECEPTORS.
 SECOND AND THIRD FLOOR P/T CAN RUN OUT
 IN THE CEILING OF FIRST FLOOR AND STUB
 OUT 6" ABOVE GRADE. FIRST FLOOR P/T
 CAN DRAIN TO FLOOR.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-10-12 Cont ID  
Sent By kstevens Date 2002-10-12 Time 10:06 Rev Time 1.00
Received By kstevens Date 2002-10-12 Time 10:06 Sent To  
Notes
2002-10-12 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) SHTS P-U3, P-U4, P-U5, & P-U6 WATER
 RISER DIAGRAMS, WATER HAMMER ARRESTORS
 AT WASH MACHINES TO LOCATED NEAR FIX-
 TURES IN AN "EFFECTIVE RANGE" NOT AT THE
 TOP OF THE DROP AS SHOWN.
 2) SHT P-T2.1 CLEAN OUT REQUIRED IN THE
 BREEZE WAYS. SEC 708.3.1 - 100' MAX BE-
 TWEEN CLEANOUTS.
 3) SHT P-T2.3 CLEAN OUTS REQUIRED IN
 SANITARY RISER DIAGRAM. SEE COMMENT #2
 4) SHT PD-1 WATER HEATER PAN DRAIN & T/P
 RELIEF RISERS, T/P RELIEF LINE SHALL NOT
 BE TRAPPED. SEC 504.7.1
 5) SHT PD-1 PLUMBING GENERAL NOTES #6,
 DIELECTRIC UNIONS ARE NOT APPROVED FOR
 WATER. PLEASE DELETE REFERENCE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 3 Status P Date 2003-04-17 Cont ID  
Sent By sgraham Date 2003-04-17 Time 16:25 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2003-02-11 Cont ID  
Sent By sgraham Date 2003-02-11 Time 09:42 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
2003-02-11 00:00:00DENIED, NEED TO AMEND PLANS TO MATCH
 APPROVED SITE PLAN

Review Stop Z ZONING
Rev No 1 Status F Date 2002-09-24 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 08:42 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-09-24 00:00:00DENIED, NEED CITY COMMISSION APPROVAL
 DENIED, NEED CITY COMMISSION APPROVAL