| Plan Review Stops For Permit 02090695 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-06-05 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-06-05 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-05 00:00:00 | REVISON DATED 4/16/03 ADT1 & SD5 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-05-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-03 |
Time |
10:13 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-05-02 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2003-05-02 00:00:00 | PASSED PER BILL STAPLES | | | | | | | | | SEE CONSTRUCTION BOARD OF ADJUSTMENT | | | AND APPEALS MINUTES, JANUARY 8, 2003 | | | CASE #1225, AND APRIL 17, 2003 CASE | | | #1231. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-15 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-15 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | SEE COMMENTS 02090696 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-02-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-13 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-13 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2003-02-13 00:00:00 | PAID PLAN REVIEW NOT A PERMIT | | | APPLICATION. | | | | | | THE COMMENTS PROVIDED IN THE 10/02/02 | | | LIST REGARDING IMPACT FEES, RESIDENT | | | INSPECTOR, PRODUCT REPORTS, ETC. ARE | | | THE SAME AND STILL APPLICABLE. | | | | | | SHEET SD4 STILL CONTAINS DESIGN | | | INFORMTION AS BEING 1997 SBC AND 110 | | | MPH.SD5 MAKES REFERENCE TO THE HVHZ | | | AND FBC 1606.2.THE CITY OF WEST PALM | | | BEACH IS UNDER THE 2001 FLORIDA | | | BUILDING CODE AND IS IN THE 140 MPH | | | WIND ZONE.CLEARLY NOTE IF ASCE 7-98 | | | CHAPTER 6 OR FBC 1606.2 WAS USED FOR | | | THE DESIGN, IN ADDITION OR IN PLACE OF | | | THE SEVERAL CODES AND STANDARDS CITED | | | ON THE PLANS. | | | | | | THERE ARE STILL TWO INDEPENDENT EXITS | | | REQUIRED BY FBC 1004.2.1 FOR THE SECOND | | | AND THIRD LEVELS. | | | | | | THE EXIT CONFIGURATION SHOWN DOES NOT | | | COMPLY WITH FBC 1006.1 FOR ENCLOSED | | | STAIRS OR 1006.2 FOR EXTERIOR STAIRS. | | | | | | THESE COMMENTS APPLY TO BUILDINGS TYPE | | | I, II, AND III, AND ARE NOT REPEATED ON | | | THOSE PLAN REVIEWS NUMBERS 02090696 AND | | | 02090697. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-17 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-10-17 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-10-16 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2002-10-17 00:00:00 | THE COMMENTS ARE THE SAME AS REVIEW | | | #02090696, A COPY OF WHICH HAS BEEN | | | ATTACHED TO THE APPLICATION SHEET FOR | | | YOUR CONVIENCE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-11 |
Time |
03:03 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-04-11 |
Time |
03:03 |
Sent To |
|
|
| Notes |
| 2003-04-11 00:00:00 | ELECTRICAL SHEETS STAMPED, READY FOR | | | ISSUE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-26 |
Time |
18:34 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-02-26 |
Time |
18:34 |
Sent To |
|
|
| Notes |
| 2003-02-26 00:00:00 | ********* UNSAT ************** | | | | | | 1)NOTE: PLEASE REMOVE SHEETS NOT | | | PERTAINING TO THIS BLDG. PLEASE SEE | | | TRASH COMPACTOR RISER? | | | | | | 2)NOTE: PLEASE SEE A COUPLE OF NOTES | | | FROM FIRST REVIEW. | | | PLEASE PROVIDE NOTE FOR "LOCK OFF" | | | DEVICE NEEDS TO BE REVIEWED BY THE | | | CITY OF WEST PALM BEACH BEFORE | | | INSTALLATION, A DISC MAY BE REQ`D. | | | MOST "SNAP ON " DEVICES ARE NOT | | | PERMIITED. | | | 3)NOTE: PLEASE SEE LOAD SHOWN FOR RANGE, | | | PLEASE CLARIFY 12KW LOAD AT 70% IS 5.6? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-08 |
Time |
06:23 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-10-08 |
Time |
06:23 |
Sent To |
|
|
| Notes |
| 2002-10-08 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE, AS PER NOTE #7 ON | | | E-SHEETS, THE LOCK OFF DEVICE MUST BE | | | A PART OF THE BREAKER. PLEASE NOTE THE | | | TYPE OF LOCK OFF DEVICE CHOSEN NEEDS TO | | | BE REVIEWED BY THE CITY OF WETS PALM | | | BEACH BEFORE INSTALLATION. PLEASE NOTE, | | | MOST OF THE " SNAP ON" DEVICES ARE NOT | | | PERMITTED TO BE USED AND A MEANS OF | | | DISC IS REQ`D. PLEASE NOTE ON PLANS. | | | | | | 2)NOTE: PLEASE SHOW REQ`MENTS FOR FAIR | | | HOUSING ACT. FHAR 24 CFR 100.205. | | | | | | 3)NOTE: PLEASE NOTE CLEARENCE FOR CLOSET | | | LIGHT INSTALLATIONPER 410-8. | | | | | | 4)NOTE: PLEASE CLARIFY LOCATION OF REC | | | FOR A/C COND UNITS PER 210-63. | | | | | | 5)NOTE: PLEASE CLARIFY GROUPING OF MAINS | | | PER 230-72. PLEASE NOTE HAVING THE SHUNT | | | TRIPS DO NOT MEET THE REQUIREMENTS OF | | | GROUPING. PLEASE NOTE SHUNTS DO NOT | | | MEET 230-76,230-79. | | | PLEASE CLARIFY HOW THE SECOND SERVICE | | | MEETS 230-2. | | | | | | 6)NOTE: MISSING EQUIPMENT GROUNDING | | | CONDUCTOR BETWEEN MAIN AND HOUSE PANEL? | | | SIZEPER 250-122 | | | | | | 7)NOTE: PLEASE INDICATE MAINS FOR APT | | | MAINS ON RISER DIAGRAM. 215-5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
sjohnson |
Date |
2002-10-16 |
Time |
14:12 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-02-10 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2003-02-10 00:00:00 | PASSED: | | | 1. SEE PERMIT # 02121237 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI | | 2002-10-16 00:00:00 | PER LUIS MARTINEZ |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-30 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-30 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-03-06 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-03-06 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2003-03-06 00:00:00 | 1) SOME PLAN REVIEW COMMENTS HAVE NOT | | | BEEN PROPERLY ADDRESSED. | | | | | | 2) EXIT SIGNS REQUIRED AT FIRST FLOOR | | | LEVEL. | | | | | | 3) IT APPEARS THAT ADDITIONAL FIRE | | | HYDRANTS ARE REQUIRED ON THE SITE PLAN. | | | BETTER PLACEMENT WITH ADDITONAL FIRE | | | HYDRANTS WOULD APPEAR TO BE PROPER. | | | | | | 4) PLEASE INDICATE LOCATIONS OF FDC'S | | | IN RELATION TO THE FIRE HYDRANTS. FDC'S | | | SHALL NOT EXCEED 150 FEET TO A FIRE | | | HYDRANT. | | | | | | 5) NFPA 13R SYSTEMS SHALL NOT BE USED | | | WHEN CODE REQUIREMNTS HAVE BEEN | | | ALTERED. NFPA 13 SYSTEMS MUST BE | | | USED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-10-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-10-04 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-10-04 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2002-10-04 00:00:00 | 1) PLEASE PROVIDE A LIFE SAFETY PLAN FOR | | | THE BUILDING. PLEASE INDICATE EXIT | | | SEPARATIONS, TRAVEL DISTANCES, ETC. | | | | | | 2) NO FIRE SPRINKLER PLANS OR HYDRAULIC | | | CALCULATIONS PROVIDED WITH PLANS. | | | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER SYSTEM. | | | | | | 4) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM. | | | | | | 5) WHAT PROVISIONS WILL BE MADE FOR FIRE | | | AND PARAMEDICAL ACCESS THRU THE SECURITY | | | GATES WHEN NORMAL POWER IS PRESENT. THIS | | | OFFICE USUALLY REQUIRES A KNOX-BOX KEY | | | SWITCH. | | | | | | 6) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING AND AFTER CONSTRUCTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-11-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-26 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-26 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2003-11-26 00:00:00 | TO COMM BD# |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-06-03 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-03 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-03 |
Time |
10:12 |
Sent To |
B |
|
| Notes |
| 2003-06-03 00:00:00 | HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-05-28 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-28 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-28 |
Time |
16:49 |
Sent To |
P |
|
| Notes |
| 2003-05-28 00:00:00 | KSTEVENS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-09 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2003-05-09 00:00:00 | ON RACK, DO NOT PROCESS UNTIL FINAL | | | PLUMBING REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-05-07 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-07 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-05-07 |
Time |
15:29 |
Sent To |
P |
|
| Notes |
| 2003-05-07 00:00:00 | TO PLUMB IN BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-29 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-29 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-29 |
Time |
15:19 |
Sent To |
P |
|
| Notes |
| 2003-04-29 00:00:00 | KSTEVENS DESK.PLUMBING REVISION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-17 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-03 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | TO COMM BOARD #42 | | | NEXT TO RACK, 3 ROLLS | | | SENT COVER SHEET TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-11 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-10 |
Time |
08:42 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-24 |
Time |
15:38 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2003-04-24 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-02-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-19 |
Time |
14:23 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-02-19 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2003-02-19 00:00:00 | DENIED:TYPE I | | | ITEMS NOT ADDRESSED ON REVIEW BY HAROLD | | | MOSER DATED 10/08/02. | | | 1.VERIFY OUTSIDE AIR REQUIREMENTS. | | | INDICATE CALCULATIONS FOR NATURAL | | | (2001 FBC(M) 402.2.) OR MECHANICAL | | | (2001 FBC(M) TABLE 403.3). | | | | | | 2.DUCTS EXTENDING MORE THAN 1 FLOOR | | | ARE REQUIRED TO BE ENCLOSED BY A SHAFT | | | ENCLOSURE AS PER 2001 FBC(M) 607.4. | | | PROVIDE DETAIL OF UL SHAFT ASSEMBLY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-10-08 |
Time |
19:23 |
Rev Time |
1.00 |
| Received By |
hmoser |
Date |
2002-10-08 |
Time |
19:22 |
Sent To |
|
|
| Notes |
| 2002-10-08 00:00:00 | PLAN DENIED | | | 1) VARIFY TYPE OF VENTILATION USED FOR | | | FRESH AIR.SECTION 402 NATURAL OR | | | MECHANICAL SECTION 403 FBC.2001 | | | 2) NEED CALCULATIONS FOR TYPE OF | | | VEVTILATION USED | | | 3) NEED MANUFACTURERS INSTALLATION ON | | | CLOTHES DRYER | | | 4) REFER TO SECTION 306.1.1 CLEARANCE | | | AROUND AIRHANDLER | | | 5) CAN NOT RUN DRYER VENT AND BATHROOM | | | EXHAUST IN SAME CHASE | | | 6) REFER TO SECTION 401.6 BATHROOM | | | EXHAUST WALL CAP MUST HAVE SCREEN. | | | BACKDRAFT DAMPER ON FAN ONLEY | | | 7) NEED ENERGY CALCS & MANUAL (J) | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2003-05-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-28 |
Time |
18:07 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-05-28 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2003-05-28 00:00:00 | REVISION OK, REROUTE SANT. & WATER LINES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-28 |
Time |
16:49 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-05-19 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) FULL OPEN VALVE REQUIRED AT ENTRANCE | | | OF STRUCTURE. 606.1(1) | | | 2) FULL OPEN VALVES REQUIRED AT BASE OF | | | EACH WATER RISER. 606.1(2) | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-07 |
Time |
15:29 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | 05-02-03 REVISION, NEW PLAN REVIEW | | | REQUIRED, PES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-12 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-29 |
Time |
15:19 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-04-12 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-04 |
Time |
17:33 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-03-04 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2003-03-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) WATER HEATER PAN DRAINS ARE NOT | | | APPROVED INDIRECT WASTE RECEPTORS. | | | SECOND AND THIRD FLOOR P/T CAN RUN OUT | | | IN THE CEILING OF FIRST FLOOR AND STUB | | | OUT 6" ABOVE GRADE. FIRST FLOOR P/T | | | CAN DRAIN TO FLOOR. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-10-12 |
Time |
10:06 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2002-10-12 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2002-10-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SHTS P-U3, P-U4, P-U5, & P-U6 WATER | | | RISER DIAGRAMS, WATER HAMMER ARRESTORS | | | AT WASH MACHINES TO LOCATED NEAR FIX- | | | TURES IN AN "EFFECTIVE RANGE" NOT AT THE | | | TOP OF THE DROP AS SHOWN. | | | 2) SHT P-T2.1 CLEAN OUT REQUIRED IN THE | | | BREEZE WAYS. SEC 708.3.1 - 100' MAX BE- | | | TWEEN CLEANOUTS. | | | 3) SHT P-T2.3 CLEAN OUTS REQUIRED IN | | | SANITARY RISER DIAGRAM. SEE COMMENT #2 | | | 4) SHT PD-1 WATER HEATER PAN DRAIN & T/P | | | RELIEF RISERS, T/P RELIEF LINE SHALL NOT | | | BE TRAPPED. SEC 504.7.1 | | | 5) SHT PD-1 PLUMBING GENERAL NOTES #6, | | | DIELECTRIC UNIONS ARE NOT APPROVED FOR | | | WATER. PLEASE DELETE REFERENCE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-17 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-11 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-02-11 00:00:00 | DENIED, NEED TO AMEND PLANS TO MATCH | | | APPROVED SITE PLAN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-10 |
Time |
08:42 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-09-24 00:00:00 | DENIED, NEED CITY COMMISSION APPROVAL | | | DENIED, NEED CITY COMMISSION APPROVAL |
|
|