| Plan Review Stops For Permit 02090643 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2003-11-25 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-11-25 |
Time |
10:29 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-11-25 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2003-11-25 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)THIS PERMIT DID NOT INCLUDE A | | | GARAGE DOOR.EITHER SUBMIT A REVISION | | | OR APPLY FOR A SEPARATE PERMIT. | | | | | | 2.)PRODUCT APPROVALS FOR PERMITS | | | APPLIED FOR AFTER OCTOBER 1, 2003 | | | REQUIRE STATEWIDE PRODUCT APPROVALS. | | | WWW.FLORIDABUILDING.ORG FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-17 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-29 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2003-08-29 00:00:00 | REPAIR DETAILS DATED 8/18/03 BY W. | | | YURASEK, PE. | | | | | | HOW WILL THE LTS 12 STRAP BE FASTENED TO | | | THE MASONRY? | | | | | | WITH THE REPLACEMENT OF CMU'S, HOW WILL | | | A CONTINUOUS LOAD PATH FOR THE FILLED | | | CELLS TO THE FOUNDATION BE | | | ACCOMPLISHED? WILL THE REPLACED MASONRY | | | HAVE A CONTINUOUS BOND BEAM? |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-28 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-03-13 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2003-03-13 00:00:00 | PLANS DATED 2/22/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-01-29 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-01-29 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-01-29 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2003-01-29 00:00:00 | PLANS DATED 1/11/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-12-06 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-12-06 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-12-06 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2002-12-06 00:00:00 | SECOND REVIEW LIST | | | | | | THE ADDITIONAL SET OF STAIRS ON THE WEST | | | SIDE OF THE SMALLER BUILDING HAS NOT | | | BEEN ADDRESSED.THE SURVEY DATED | | | 9/29/00 SHOWS ONE SET OF STAIRS ON THE | | | EAST SIDE OF THIS BUILDING.THE CITY | | | RECORDS DO NOT SHOW A PERMIT FOR THIS | | | PROPERTY INDICATING CONSTRUCTION OF | | | THESE STAIRS.WHAT IS THEIR ORIGIN? | | | SEE FBC 104.2. | | | | | | THE NOA FOR THE SHUTTERS IS EXPIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-05 |
Time |
06:06 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-09-30 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2002-10-01 00:00:00 | SHOW THE WIND PRESSURES +/- FOR THE | | | WINDOWS AND ROOF COVERING.SEE FBC | | | 1606.1.7 #7. | | | | | | SHOW THE EXISTING OR PROVIDE NEW FIRE | | | RATED TENANT SEPARATION.SEE FBC 704.3. | | | | | | SHOW THE EXISTING OR PROVIDE A FIRE | | | RATED ENCLOSURE FOR THE INTERIOR STAIRS | | | IN THE EAST BUILDING.SEE FBC 1006.1.1. | | | | | | SHOW THE EXISTING OR PROVIDE NEW, | | | HANDRAILS ON EACH SIDE OF ALL THE | | | STAIRS, IN BOTH BUILDINGS.SEE FBC | | | 1007.5. | | | | | | THE SURVEY SHOWS ONE STAIR ON THE WEST | | | SIDE OF THE WEST BUILDING.THE PLANS | | | SHOW STAIR WAYS ON THE WEST AND EAST | | | SIDES. PLEASE CLARIFY DESIGN INTENT. | | | | | | THE EXTERIOR STAIRS MUST COMPLY WITH | | | FBC 1006.2.2 FOR 3/4 HOUR PROTECTED | | | OPENING EXPOSURE.PLEASE REVISE AS | | | NECESSARY. | | | | | | NOTE CLEARLY THE EMERGENCY ESCAPE AND | | | RESCUE OPENINGS FOR THE SLEEPING ROOMS | | | IN ACCORDANCE WITH FBC 1005.4.1. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-17 |
Time |
07:16 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-03-17 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
06:55 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-02-20 |
Time |
06:55 |
Sent To |
|
|
| Notes |
| 2003-02-20 00:00:00 | ************* UNSAT ************** | | | | | | PLEASE SEE NOTES FROM FIRST THREE(3) | | | REVIEWS. NOTES NOT ADDRESSED FOR ELEC | | | OR PLUMB. | | | | | | PLEASE SEE ATTACHED BZ FOR 4X FEE THAT | | | HAS NOW BEEN ASSESSED TO THE DESIGN | | | PROFESSIONAL. PER FS 553-80 (2) (B). | | | | | | PLEASE SUBMIT FOR REVIEW, IF THERE ARE | | | ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-30 |
Time |
10:54 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-01-30 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2003-01-30 00:00:00 | *************** UNSAT ************** | | | | | | PLEASE NOTE, THERE ARE MANY ITEMS | | | FROM FIRST TWO REVIEWS NOT DONE. | | | PLEASE SEE ATTACHED LETTER FOR FS 553-80 | | | | | | 1)NOTE: PLANS HAVE BEEN REVISED NOW | | | SHOWING LAUNDRY CIRCUIT, HOWEVER PER | | | 210-11-C2 MUST BE A MIN 1500KW. | | | 210-52 | | | | | | 2)NOTE: PLANS STILL MISSING OUTLETS | | | LISTED PER 210-12 ON PANEL SCHEDULE. | | | ALSO 210-52,210-52E | | | | | | 3)NOTE: PLEASE SEE ELECTRICAL NOTES | | | MENTIONING A/C UNIT DISC'S TO BE 50A`S?? | | | PLEASE CLARIFY WHERE A/C'S UNIT ARE | | | SHOWN ON PLANS?? | | | | | | PLEASE SEE ANY PREVIOUS NOTES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | PLEASE ALSO NOTE A 4X FEE WILL BE | | | ACCESSED IF NOTES ARE NOT ADDRESSED FOR | | | PLAN REVIEW.PER FS 553-80(2)(B) | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-05 |
Time |
06:05 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2002-12-05 |
Time |
06:05 |
Sent To |
FIRE |
|
| Notes |
| 2002-12-05 00:00:00 | *************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE, REVIEW IS DONE FOR | | | A COMPLETED SERVICE RISER. PLEASE NOTE, | | | MISSING AIC RATING FOR NEW SERVICE | | | EQUIPMENT. MAIN DISC'S , PANELS AND BRKR | | | -S ALL MUST BE RATED FOR THE AVAILABLE | | | FAULT CURRNT PER 110-9 | | | | | | 2)NOTE: PLEASE NOTE MISSING REQ'D | | | CIRCUITS PER 210-11C-2 (LAUNDRY) | | | | | | 3)NOTE: PLEASE NOTE, WATER HEATERS MAY | | | NOT BE IN STORAGE/CLOSETS W/ EASILY | | | IGNITABLE MATERIALS. PLEASE PROVIDE | | | SEPARATION.422-17 | | | | | | 4)NOTE: PLEASE NOTE ITMES FROM FIRST | | | REVIEW WERE NOT ADDRESSED. 210-52E/ | | | 210-12 | | | | | | PLEASE NOTE, FOOTER STEEL IS SHOWN ON | | | RISER, PLEASE NOTE, NOT REQ`D ON EXIST- | | | ING BLDG TO CUT CONCRETE FOR THIS.PLEASE | | | NOTE HOWEVER, IF SHOWN ON PLANS, THEN IT | | | WILL BE REQ`D. PLEASE ALSO NOTE | | | SERVICE CONDUCTORS ARE BEING SHOWN AT | | | FOUR TIMES LARGER THAN REQ`D PER 310-15 | | | PLEASE NOTE, THE ABOVE IS JUST A NOTE | | | AND DOES NOT REFLECT ANY CODE VIOLATIONS | | | IF CHANGED AT LATER DATE, A REVISION | | | WILL BE REQ`D. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-10-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-03 |
Time |
12:42 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-10-03 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2002-10-03 00:00:00 | ************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE PLANS NEED TO BE | | | COMPLETED FOR FULL REVIEW. | | | PLEASE NOTE MISSING SERVICE ENTRANCE | | | CONDUCTORS. 215-5 | | | | | | 2)NOTE: PLEASE NOTE MISS RECEPTS PER | | | 210-52,210-52E. | | | | | | 3)NOTE: PLEASE NOTE EQUIPMENT GROUNDING | | | CONDUCTORS MISSING PER 250-122. | | | | | | 4)NOTE: PLEASE NOTE RISR DIAGRAM SHOWS | | | GUTTER FEEDING SERVICE AND YET PLANS | | | SHOWS BEING SEPARATE? PLEASE CLARIFY AND | | | NOTE 230-72. | | | | | | 5)NOTE: PLEASE NOTE MISSING ARC FAULT | | | PROTECTION. PER 210-12. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-03-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-03-21 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-03-21 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-01-23 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-01-23 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-05 |
Time |
06:06 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-05 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2002-12-05 00:00:00 | 1) DOORS WITHIN 1 HOUR RATED WALLS ARE | | | REQUIRED TO BE RATED. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, EXT. 8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-10-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-10-04 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-10-04 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2002-10-04 00:00:00 | 1) PLEASE SHOW TENANT SEPARATION WALLS. | | | | | | 2) PLEASE DISPLAY EMERGENCY EGRESS | | | WINDOWS. | | | | | | 3) PLEASE CLEARLY IDENTIFY ALL EXITS. | | | | | | 4) PLEASE SEE BUILDING PLAN REVIEW | | | COMMENTS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-11-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-17 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-17 |
Time |
13:41 |
Sent To |
B |
|
| Notes |
| 2003-11-17 00:00:00 | TO HP DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-09-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-26 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-26 |
Time |
08:16 |
Sent To |
B |
|
| Notes |
| 2003-09-24 00:00:00 | TO HP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-08-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-28 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-28 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
| 2003-08-28 00:00:00 | TO HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-03-12 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-12 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-12 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2003-03-12 00:00:00 | COMM BOARD #63 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-06 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-02-06 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2003-02-06 00:00:00 | COM BOARD #60./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-17 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-17 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2003-01-17 00:00:00 | TO COM BOARD#25./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-14 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-14 |
Time |
16:42 |
Sent To |
Z |
|
| Notes |
| 2002-11-14 00:00:00 | TO Z IN BOX./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-09-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-09-28 |
Time |
08:55 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2002-09-28 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2002-09-28 00:00:00 | WINDOW UNITS TO BE INSTALLED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2003-03-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-22 |
Time |
08:44 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-03-22 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2003-03-22 00:00:00 | PASSED/PROVISO | | | | | | BACKING PER REQUIREMENT #6 FHA DESIGN | | | MANUAL |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2003-02-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-08 |
Time |
08:06 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-02-08 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2003-02-08 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FHA-AMEND 98 DESIGN MANUAL | | | | | | 1) FROM PREVIOUS REVIEW: SHOW DETAILS | | | FOR COMPLIANCE WITH DESIGN MANUAL FOR | | | REQUIREMENTS 1 THRU 7. INDICATE SPECIF- | | | ICATION "A" OR "B" FOR BATHROOMS. SHOW | | | CLEAR FLOOR SPACE FOR EACH FIXTURE AS | | | REQUIRED ON PAGE 7.43 PARAGRAPH ONE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-24 |
Time |
10:04 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-01-24 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2003-01-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FHA-AMEND 98 DESIGN MANUAL | | | | | | 1) SHT 2 OF 3 SANITARY PLUMBING RISER, | | | SEE RED LINE CORRECTIONS FOR RISER. | | | PLEASE MAKE CORRECTIONS TO RISER AND RE- | | | SUBMIT. | | | 2) UNITS 1, 2, 4, & 5 SHALL COMPLY WITH | | | FHA DESIGN MANUAL REQUIREMENTS 1 THRU 7. | | | ALSO INDICATE SPECIFICATION "A" OR "B" | | | FOR BATHROOMS FOR EACH UNIT. GIVE ALL | | | DETAILS REQUIRED BY DESIGN MANUAL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-12-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-04 |
Time |
16:45 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-12-04 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2002-12-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) FROM PREVIOUS REVIEW: LAUNDRY FACIL- | | | ITIES REQUIRED PER TABLE 403.1 | | | 2) SHT 2 OF 3 SANITARY RISER DIAGRAM, | | | BATHROOMS FROM SECOND FLOOR SHALL NOT | | | DRAIN THROUGH VENTS FROM FIRST FLOOR | | | BATHROOMS IN UNITS 1,2,3,4. ONLY THE | | | FIXTURES FROM THE BATHROOM GROUP SHALL | | | DRAIN INTO THE WET VENT SYSTEM FOR THE | | | BATHROOM. KITCHEN SINK SHALL DRAIN DOWN- | | | STREAM OF BATHROOM GROUP. SECTION 909.1 | | | 3) BACKFLOW IS REQUIRED ON WATER SERVICE | | | IF UNITS ARE NOT INDIVIDUALLY METERED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-09-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-09-28 |
Time |
09:02 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2002-09-28 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2002-09-28 00:00:00 | DENIED; | | | 1.LAUNDRY FACILITIES REQUIRED, PER FBC | | | PLUMBING TABLE 403.1. | | | 2.SHOW SANITARY RISER DIAGRAM; | | | ALL NEW SANITARY PIPES | | | ALL NEW VENT PIPES | | | SIZE ALL NEW PIPES | | | SHOW LOCATION OF TIE IN TO OLD | | | SYSTEM AND SIZE OF OLD PIPES. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT 8369 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-12-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-12-04 |
Time |
15:34 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-09-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-14 |
Time |
16:42 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-09-19 00:00:00 | DENIED, PORCH ENCLOSURE MUST MEET 25' | | | FRONT SETBACK- SENT TO BLDG FOR REVIWE | | | LANDSCAPING MUST BE TO CITY CODES |
|
|