|
 |
 |
 |
 |
 |
Plan Review Details - Permit 02090542
| Plan Review Stops For Permit 02090542 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-09-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-26 |
Time |
12:08 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-09-26 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2002-09-26 00:00:00 | NOTES REDLINED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-09-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-09-21 |
Time |
11:44 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-09-21 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-10-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2002-10-25 |
Time |
09:14 |
Rev Time |
0.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-25 00:00:00 | REVISION APPR,PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-09-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-09-21 |
Time |
11:44 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-09-21 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2002-09-21 00:00:00 | DENIED; | | | RISER DIAGRAM DOES NOT REFLECT FLOOR | | | PLAN. REVISE RISER DIAGRAM. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2002-10-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2002-10-28 |
Time |
12:56 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2002-10-03 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2002-10-03 |
Time |
09:43 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-03 00:00:00 | *******************FAILED************* | | | | | | 1. NEED RECORDED NOC BEFORE PERMIT IS | | | ISSUED. | | | 2. IMPACT FEES PAID AT PBC ARE BASED ON | | | 1ST FLOOR A/C ONLY.TAKE PRINTS BACK TO | | | COUNTY & HAVE CORRECTED. | | | 3. NEED GLASS BLOCK PRODUCT APPROVALS, | | | SBCCI OR MIAMI-DADE; OR SITE SPECIFIC | | | ENGINEERING. | | | 4. ENERGY FORM INCORRECT: | | | A. SQUARE FOOTAGE OF A/C WRONG | | | B. # OF BEDROOMS WRONG. (SHOULD BE | | | 5 BEDROOMS)PLEASE REVIEW COMPLETE | | | ENERGY FORM FOR ACCURACY BEFORE | | | RESUBMITTAL. | | | 6. STORM PANEL SCHEDULE DOES NOT SHOW | | | CORRECT OPENING SIZES (IE: GLASS BLOCK | | | OPENING IS 48" X 96" PER SHEET 3 OF 9) | | | 7. FLAGS ON PLANS REFERENCING OTHER PAGE | | | S DO NOT MATCH.(IE: A-5; B-5 SHEET 3 | | | 8. ROOF SHEATING REFERENCED AS 5/8 AND 1 | | | 9/32.CORRECT PLANS TO REFLECT CORRECT | | | THICKNESS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 659-8096 EXT. 8394 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-09-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-09-19 |
Time |
08:43 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |