Plan Review Details - Permit 02090382
Plan Review Stops For Permit 02090382
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-25 Cont ID  
Sent By jwitmer Date 2002-10-25 Time 13:32 Rev Time 2.00
Received By jwitmer Date 2002-10-25 Time 13:32 Sent To  
Notes
2002-10-25 00:00:00 
  
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02090382
 ADDRESS: 222 LAKEVIEW/ 305
 CONT: HEDRICK BROTHERS
 TELL # (561)689-8880
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-18 Cont ID  
Sent By jwitmer Date 2002-09-18 Time 08:16 Rev Time 1.25
Received By jwitmer Date 2002-09-18 Time 08:16 Sent To  
Notes
2002-09-18 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT:02090382
 ADD: 222 LAKEVIEW AVE # 305
 CONT: CATALFUMO
 TEL: (561)694-3000
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) CORRECT ALL REFRENCES TO THE UBC,
 FLORIDA IS CURRENTLY REVIEWING PLANS TO
 THE 2001 FLORIDA BUILDING CODE.
  
 2)11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL. SEE ATTACHMENT. DOORS IN
 NONCOMPLIANCE ARE HIGHLIGHTED IN YELLOW
 ON FLOOR PLAN (A-3).
  
 11-4.1.6 ACCESSIBLE BUILDINGS, ALTERA-
 TIONS (2) ALTERATIONS MADE TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL TO ALTERED
 AREAS SHALL BE DEEMED DISPROPORTIONATE
 TO THE OVERALL ALTERATION WHEN COST
 EXCEED 20 PER CENT OF THE COST OF THE AL
 TERATION TO THE PRIMARY FUNCTION AREA.
  
 (2) (A) IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE
 GIVEN TO THOSE ELEMENTS THAT WILL PRO-
 VIDE THE GREATEST ACCESS, IN THE FOLLOW-
 ING ORDER:
 (I) AN ACCESSIBLE ENTRANCE
 (II) AN ACCESSIBLE ROUTE TO THE ALTERED
 AREA.
 (III) AT LEAST ONE ACCESSIBLE RESTROOM
 FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM.
 (IV) ACCESSIBLE TELEPHONES
 (V) ACCESSIBLE DRINKING FOUNTAIN
 (VI) ACCESSIBLE ELEMENTS SUCH AS PARKING
 STORAGE AND ALARMS.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-24 Cont ID  
Sent By dpalmer Date 2002-12-24 Time 12:52 Rev Time 0.25
Received By dpalmer Date 2002-12-24 Time 12:52 Sent To FIRE
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-09-12 Cont ID  
Sent By btrobaug Date 2002-12-18 Time 09:23 Rev Time 0.50
Received By dpalmer Date 2002-09-12 Time 14:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-09-13 Cont ID  
Sent By dpalmer Date 2002-12-24 Time 12:52 Rev Time 0.00
Received By mcarsill Date 2002-09-13 Time 14:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-18 Cont ID  
Sent By btrobaug Date 2002-12-18 Time 09:23 Rev Time 0.00
Received By btrobaug Date 2002-12-12 Time 09:23 Sent To E
Notes
2002-12-18 00:00:00TO DVP./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-12 Cont ID  
Sent By btrobaug Date 2002-11-12 Time 17:12 Rev Time 0.00
Received By btrobaug Date 2002-11-08 Time 17:11 Sent To M
Notes
2002-11-12 00:00:00TO PATTY./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2002-12-26 Cont ID  
Sent By hmoser Date 2002-12-26 Time 15:49 Rev Time 0.33
Received By hmoser Date 2002-12-26 Time 15:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-11-13 Cont ID  
Sent By pkrauss Date 2002-11-13 Time 15:16 Rev Time 0.25
Received By pkrauss Date 2002-11-13 Time 15:15 Sent To  
Notes
2002-11-13 00:00:00MECHANICAL PERMIT 02101860
 SUBMITTAL LETTER

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-10-25 Cont ID  
Sent By btrobaug Date 2002-11-12 Time 17:12 Rev Time 0.35
Received By pkrauss Date 2002-10-25 Time 15:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-09-25 Cont ID  
Sent By pkrauss Date 2002-09-25 Time 13:58 Rev Time 1.00
Received By pkrauss Date 2002-09-24 Time 14:38 Sent To  
Notes
2002-09-25 00:00:00DENIED:
  
 PLEASE CLAFIFY THE FOLLOWING -
  
 1.PLAN SHEET M-2 MECH KEY NOTE 1,
 TRANSFER DUCTS REPLACING EXISTING
 SMOKE & VENTILATION AIR EXHAUST.
 CLARIFY HOW A TRANSFER DUCT WILL
 BE REPLACING A SMOKE OR EXHAUST. IS
 THE AIR BEING TRANSFERRED FROM A
 BATHROOM TO A COMMON AREA?
  
 2.PLAN SHEET M-2 KEY NOTE 5, INSTALL
 NEW FIRE DAMPER AT THIS LOCATION.
 IT APPEARS FIRE DAMPERS ARE BEING
 INSTALLED IN FLEX DUCT.IS THIS
 CORRECT?AS PER 2001 FBC(M) 603.5.5
 FLEXIBLE AIR DUCTS SHALL NOT PASS
 THROUGH ANY FIRE RATED ASSEMBLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-09-23 Cont ID  
Sent By kstevens Date 2002-09-23 Time 17:09 Rev Time 0.00
Received By kstevens Date 2002-09-23 Time 17:09 Sent To  
Notes
***NONE***