Plan Review Details - Permit 02090190
| Plan Review Stops For Permit 02090190 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-10-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-17 |
Time |
12:51 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-10-17 |
Time |
12:42 |
Sent To |
R |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-09-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-25 |
Time |
06:35 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-09-25 |
Time |
06:35 |
Sent To |
B |
|
| Notes |
| 2002-09-25 00:00:00 | ***********UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE NO EQUIPMENT GROUND- | | | ING CONDUCTOR BETWEEN MAIN DISCONNECTS | | | AND METER. THIS WOULD BE PARALLELING THE | | | NEUTRAL. PER 250-24 | | | | | | 2)NOTE: PLEASE SEE PANEL "B". PLEASE | | | CORRELATE LOADS SHOWN FOR A/C #3. | | | PLEASE ADJUST LOAD CALCS. | | | | | | 3)NOTE: PLEASE SEE PANEL AND RISER | | | DIAGRAM. PLEASE NOTE PANELS SHOWN W/MCB | | | AND RISER SHOWN AS MLO? PLEASE CORRELATE | | | | | | 4)NOTE: PLEASE CLARIFY NOTE ON LOWER | | | RIGHT HAND CORNER, NOTING GAS WATER | | | HEATER? SHOWN AS ELEC ON PANEL SCHEDULE? | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-09-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-09-14 |
Time |
12:02 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2002-09-14 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-09-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-09-14 |
Time |
12:02 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-09-14 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2002-10-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-17 |
Time |
12:51 |
Rev Time |
0.50 |
| Received By |
lhatten |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-17 00:00:00 | PRODUCT APPROVALS OK FOR ALL DOORS | | | 10/17/2002 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2002-10-08 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2002-10-08 |
Time |
15:10 |
Rev Time |
6.00 |
| Received By |
lhatten |
Date |
2002-10-05 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2002-10-08 00:00:00 | REVIEW & STAMPED PLANS 10/05/2002 | | | NEED PRODUCT APPROV. FOR FRONT DOORS & | | | SIDELIGHTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-09-12 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-09-12 |
Time |
11:15 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|