Plan Review Details - Permit 02090115
Plan Review Stops For Permit 02090115
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-02-07 Cont ID  
Sent By btrobaug Date 2003-02-07 Time 11:09 Rev Time 0.50
Received By btrobaug Date 2003-02-07 Time 07:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-22 Cont ID  
Sent By btrobaug Date 2002-10-22 Time 14:37 Rev Time 0.50
Received By btrobaug Date 2002-10-22 Time 14:22 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-09-20 Cont ID  
Sent By btrobaug Date 2002-09-20 Time 13:59 Rev Time 1.00
Received By btrobaug Date 2002-09-20 Time 07:05 Sent To R
Notes
2002-09-20 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION,MAKE ANY NECCESARY CHANGES
 ON THE PLANS,AND RESUBMIT FOR REVIEW.
  
 1} INDICATE HOW PANEL "B" IS BEING FED.
 PANEL "A" DOES NOT HAVE A BREAKER
 LISTED FOR IT AND IS NOT LISTED AS A
 FEED THROUGH.
  
 2} INDICATE THE CONDUIT & WIRE SIZE
 FEEDING PANEL "B".
  
 4} INDICATE THE OCP OF THE MAIN
 (3/0=225AMPS).
  
 5} PLEASE INDICATE THE MAIN DISCONNECT
 LOCATION ON THE PLANS.NOTE
 230-70(A)C.W.P.B..
  
 6} THE PLANS SHOW A SERVICE-
 LATERAL,PLEASE NOTE 680-10 REGARDING
 THE POOL.
  
 7} PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S). PER 210-11-C-3,ON THE PANEL
 SCHEDULE.
  
 8} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12
  
 9} PLEASE NOTE THE BATH GFI'S REQUIRED
 BY 210-11(C)(3) MUST ALSO COMPLY WITH
 210-52(D).THESE RECEPTACLE LOCATIONS
 NEED TO BE SHOWN ON THE PLANS.
  
 10} THE DETACHED GARAGE MUST COMPLY WITH
 225-31.ALSO SEE 250-32(A) EXEPTION.
  
 11} ALL EQUIPMENT MUST COMPLY WITH
 110-26 EG: DISCONNECTS FOR CONDENSERS.
  
 12} KITCHEN ISLAND TO COMPLY WITH
 210-52(C)(2).
  
 IF THERRE ARE ANY QUESTIONS PLEASE CALL;
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-10-17 Cont ID  
Sent By hmoser Date 2002-10-17 Time 16:17 Rev Time 0.50
Received By hmoser Date 2002-10-17 Time 16:17 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-09-14 Cont ID  
Sent By jleech Date 2002-09-14 Time 11:04 Rev Time 0.50
Received By jleech Date 2002-09-14 Time 11:03 Sent To  
Notes
2002-09-14 00:00:00ENERGY CALCULATIONS AND MANUAL J
 REQUIRED WITH PLANS.
 A/C PLAN REVIEW BY
 JOHN LEECH
 659-8096 EXT 8369

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-12-05 Cont ID  
Sent By kstevens Date 2002-12-05 Time 14:15 Rev Time 0.50
Received By kstevens Date 2002-12-05 Time 14:15 Sent To  
Notes
2002-12-05 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-09-14 Cont ID  
Sent By jleech Date 2002-09-14 Time 11:06 Rev Time 0.33
Received By jleech Date 2002-09-14 Time 11:06 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2003-01-08 Cont ID  
Sent By hpiskura Date 2003-01-08 Time 10:11 Rev Time 0.00
Received By hpiskura Date 2003-01-08 Time 10:11 Sent To  
Notes
2003-01-08 00:00:00STRUCTURAL REVISION #5 DATED 1/7/03

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-12-30 Cont ID  
Sent By jgomez Date 2002-12-30 Time 14:54 Rev Time 0.50
Received By jgomez Date 2002-12-30 Time 14:35 Sent To  
Notes
2002-12-30 00:00:00REVISION FOR ROOF TRUSS AND LINTEL.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-10-09 Cont ID  
Sent By btrobaug Date 2002-09-20 Time 15:21 Rev Time 2.50
Received By lhatten Date 2002-10-08 Time 09:00 Sent To  
Notes
2002-10-16 00:00:00REVIEW & STAMPED PLANS 10/08/2002
 CALC. FEES 10/09/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-09-12 Cont ID  
Sent By sgraham Date 2002-09-12 Time 11:03 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***