| Plan Review Stops For Permit 02081899 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-01-14 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-11-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-09 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-11-07 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-09-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-09-13 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-09-13 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-01-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-09 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-09 |
Time |
16:56 |
Sent To |
B |
|
| Notes |
| 2003-01-09 00:00:00 | TO HHP./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-11-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-09 |
Time |
16:56 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-11-05 |
Time |
06:14 |
Sent To |
|
|
| Notes |
| 2002-11-05 00:00:00 | *********** PROVISO/ NOTES ********** | | | | | | PLEASE SUBMIT CIRCITING ON PLANS AND | | | PANEL SCHEDULE BEFORER ROUGH INSPECTION. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-08-28 |
Time |
19:03 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-08-28 |
Time |
19:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2002-09-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-09-13 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-11-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-15 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-15 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-08-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-08-28 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-08-28 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-09 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-09 |
Time |
16:55 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-10-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-31 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-10-30 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2002-10-31 00:00:00 | TO COMM BOARD #8./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-11-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-09-12 |
Time |
08:56 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2002-09-12 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2002-11-15 00:00:00 | NO MECH PLANS SUBMITTED FOR REVIEW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-11-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-12 |
Time |
18:41 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-11-12 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2002-11-12 00:00:00 | PASSED PROVISO - WATER COOLER SHALL | | | COMPLY WITH ARI-1010 - TOILET ROOM SHALL | | | COMPLY WITH SEC 11-4.22 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-09-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-09-09 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-09-09 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2002-09-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) TOILET ROOM SHALL COMPLY WITH SECTION | | | 11-4.22 AND ALL SUBSECTIONS. | | | DOOR SHALL NOT SWING INTO CLEAR FLOOR | | | SPACE OR UNOBSTRUCTED 5' TURNING RADIUS. | | | LAV HEIGHT - W/C HEIGHT - W/C SHALL BE | | | 18" OFF WALL TO CENTER OF FIXTURE - GRAB | | | BARS - ECT. PLEASE PROVIDE DETAILS FOR | | | TOILET ROOM | | | 2) TABLE 403.1 REQUIRES A DRINKING FOUN- | | | TAIN. ALSO SEE SECTION 410.1 IF A WATER | | | COOLER IS USED IT SHALL COMPLY WITH ARI- | | | 1010. PLEASE PROVIDE MANUF. INFO FOR | | | WATER COOLER IF USED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2002-09-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-09-13 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|