Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-10-10 Cont ID  
Sent By rbrown Date 2002-10-10 Time 15:14 Rev Time 0.00
Received By rbrown Date 2002-10-10 Time 15:14 Sent To  
Notes
2002-10-10 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
  
 THE FOLLOWING IS A REVIEW OF THE PLAN
 RE-SUBMITTAL MADE IN REPONSE TO JIM
 WITMER'S 9/27/02 PLAN REVIEW COMMENTS.
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THAT PLAN REVIEW.
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) FBC 104.3.1.1MINIMUM PLAN REVIEW
 CRITERIA.THIS COMMENT WAS NOT
 ADDRESSED.SUBMIT A FLOOR PLAN SHOWING
 ANY CHANGE IN FLOOR LEVEL AT THE FORMER
 GARAGE DOOR LOCATION, THE WIDTH/LOCATION
 OF THE FAMILY ROOM DOORWAY, AND THE
 OVERALL SIZE OF THE PROPOSED FAMILY ROOM
 SO THAT THE MINIMUM REQUIREMENTS FOR
 EGRESS (FBC 1012.1.3 AND TABLE 1004) AND
 FOR LIGHT AND VENTILATION TO THE NEW
 ROOM CAN BE ASSESSED.SUBMIT A CROSS-
 SECTIONAL VIEW OF THE WALL SHOWING THE
 PROPOSED WALL CONSTRUCTION (INCLUDING
 SHEATHING) FROM FOUNDATION/SLAB TO ROOF.
  
 3,4,5) FBC 1606THESE COMMENTS HAVE NOT
 BEEN ADDRESSED.THE PROPOSED 2-1/2"
 TAPCONS WILL NOT HAVE SUFFICIENT
 EMBEDMENT WHEN USED TO ANCHOR DOWN THE
 2"X 4" SILL PLATE.RE-SPECIFY TO ENSURE
 NO LESS THAN 1-1/4" EMBEDMENT. THE PLANS
 DO NOT STATE TO WHAT SUBSTRATE THE SILL
 PLATE IS BEING ATTACHED.IS THERE A
 SLAB AT THIS LOCATION AND WHAT IS THE
 EDGE THICKNESS?THE PROPOSED MEANS OF
 ATTACHMENT FOR THE SIDES AND TOP OF THE
 INFILL WALL FRAMEWORK IS NOT CLEAR FROM
 THE PLANS.CLEARLY SPECIFY THE PROPOSED
 ATTACHMENT METHOD ON THE PLANS.ALSO,
 THE PLANS SHALL SHOW THE EXISTING
 CONSTRUCTION AT THE SIDES OF THE OPENING
 WHICH WILL BE THE SUBSTRATE TO WHICH THE
 NEW WALL WILL BE ATTACHED.THE PLANS
 SHALL SPECIFY THE MEANS OF ATTACHMENT OF
 THE NEW WINDOW TO THE WINDOW BUCK.
  
 THREE DIFFERENT WINDOW PRODUCT APPROVALS
 HAVE BEEN SUBMITTED, INCLUDING BOTH
 ARCHED AND RECTANGULAR WINDOWS.WHICH
 PRODUCT IS TO BE USED?THE APPROPRIATE
 PRODUCT APPROVAL DRAWINGS/TABLES SHALL
 BE MARKED TO SHOW WHICH WINDOW TYPE/SIZE
 IS PROPOSED.SUBMIT TWO COPIES OF THE
 RELEVANT PRODUCT APPROVALS:
 - TEXT SHEETS 2 & 3 AND ALL OF THE
 DRAWING SHEETS SUBMITTED AS PART OF THE
 SERIES PA-14 ALUMINUM SINGLE HUNG WINDOW
 PRODUCT APPROVAL NOA#01-0226.04 ARE FROM
 A DIFFERENT PRODUCT APPROVAL
 (NOA# 97-1027.09) WHICH EXPIRED 7-9-01.
 - DRAWING SHEET 1 OF THE RECTANGULAR
 ALUMINUM FIXED WINDOW PRODUCT APPROVAL
 NOA# 01-0209.11 IS A VERY POOR REDUCED
 SIZE COPY WHICH CANNOT BE READ.ALSO,
 THE 11" X 14" DRAWING SHEET 'PA14....'
 ATTACHED TO THE PRODUCT APPROVAL IS NOT
 PART OF THE APPROVAL DOCUMENT AND SHALL
 BE REMOVED FROM THE PACK.
 - DRAWING SHEET 1 OF THE RADIUS ARCH
 ALUMINUM FIXED WINDOW PRODUCT APPROVAL
 NOA# 01-0209.10 IS AGAIN A VERY POOR
 REDUCED SIZE COPY WHICH CANNOT BE READ.
 THE 11"X 14" DRAWING SHEET 'PA14....'
 ATTACHED TO THE PRODUCT APPROVAL IS NOT
 PART OF THE APPROVAL DOCUMENT AND SHALL
 BE REMOVED FROM THE PACK.
 - SUBMIT TWO COPIES OF AN APPROPRIATE
 CURRENT AND LEGIGLE PRODUCT APPROVAL FOR
 THE WINDOW.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 JIM WITMER(561) 659 8096 EXT 8412
 ROBERT BROWNEXT 8499

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-27 Cont ID  
Sent By jwitmer Date 2002-09-27 Time 12:55 Rev Time 1.25
Received By jwitmer Date 2002-09-27 Time 12:55 Sent To  
Notes
2002-09-27 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02081787
 ADD: 501 N WARE DRIVE
 CONT: O/B DIXON,TONDA
 TEL: (561)689-4964
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) ADMINISTRATIVE CODE 104.2.1.3
 QUALITY OF BUILDING PLANS. BUILDING
 PLANS SHALL BE DRAWN TO A MINIMUM 1/8TH
 INCH SCALE. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY,
 STANDARDS FOR PLANS AND SPECIFICATIONS
 IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM.
  
 2) 104.3.1.1 MINIMUM PLAN REVIEW CRITER-
 IA FOR BUILDING PLAN REVIEW:
 A) SURVEY OR SITE PLAN
 B) FIRE RESISTANCE CONSTRUCTION, TYPE
 OF BUILD I-VI
 C) FIRE AND OR SMKE DETECTORS
 D) EGRESS - WINDOW SIZE AND LOCATION
 E) STRUCTURAL REQUIREMENTS SHALL IN-
 CLUDE THE FOLLOWING:
 1) FLOOR PLAN OF EXIST & NEW WORK
 2) WALL SECTIONS FROM FOUNDATION
 THROUGH ROOF
 3) INCLUDE ASSEMBLIES AND MATERIALS
 4) CONNECTOR TABLES
 5) WIND REQUIREMENTS
 6)STRUCTURAL CALCS
  
 3) PLANS NOT DESIGNED BY A DESIGN PROFES
 SIONAL SHALL BE DESIGNED UNDER:
 1606.1.1 EXC (4) AF&PA WOOD FRAME
 CONSTRUCTION MANUAL FOR ONE & TWO
 FAMILY - 1995 SBC HIGH WIND EDITION
 1996 SHALL BE PERMITTED FOR APPLICABLE
 WOOD FRAME BUILDINGS OF GROUP 3 OCCU-
 PANCY FOR A BABIC WIND SPEED OF 146 MPH
 OR LESS IN EXPOSURE B AND 124MPH OR LESS
 IN EXPOSURE C IN ACCORDANCE WITH FIGURE
 1606 AND SECTION 1606.1.8.
  
 4)FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 5)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-27 Cont ID  
Sent By sgraham Date 2002-08-27 Time 12:01 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***