Plan Review Details - Permit 02081617
Plan Review Stops For Permit 02081617
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-11 Cont ID  
Sent By hpiskura Date 2002-10-11 Time 10:25 Rev Time 0.00
Received By hpiskura Date 2002-10-11 Time 10:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-05 Cont ID  
Sent By hpiskura Date 2002-09-05 Time 08:29 Rev Time 0.00
Received By hpiskura Date 2002-10-03 Time 06:07 Sent To  
Notes
2002-09-05 00:00:00THE "EXECUTIVE OFFICES" COMPRISE
 SEPARATE TENANTS, THEREFORE COMPLIANCE
 WITH FBC704.3.1 IS REQUIRED SINCE IT
 APPEARS THETOTAL SPACE EXCEEDS THE 3000
 SQUARE FEET AREA EXCEPTION.PLEASE
 REVISE AS NECESSARY.
  
 IT APPEARS SEVERAL OF THE PROPOSED
 OFFICES WILL NOT HAVE THE HC
 MANEUVERING CLEARANCE AT THE DOORS
 SHOWN AS (1), AND REQUIRED BY FBC
 11-4.13.6.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-03 Cont ID  
Sent By dpalmer Date 2002-10-03 Time 06:08 Rev Time 0.25
Received By dpalmer Date 2002-10-03 Time 06:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-08-29 Cont ID  
Sent By dpalmer Date 2002-08-29 Time 05:44 Rev Time 0.30
Received By dpalmer Date 2002-08-28 Time 20:55 Sent To  
Notes
2002-08-29 00:00:00**************** UNSAT *************
  
 1)NOTE: PLEASE CLARIFY METHOD OF
 EQUIPMENT GROUND FOER NEW PANEL. SIZE
 PER 250-122.
  
 2)NOTE: PLEASE NOTE, NEED LOAD CALCS
 FOR EXISTING PANEL "2S" AND 2T.
 PLANS SHOWING NEW LOADS TO EXISTING
 PANELS. PLEASE CLARIFY
  
 3)NOTE: PLEASE VERIFY MEANS OF DISC
 FOR NEW AHU`S. 440-11.
  
 4)NOTE: PLEASE CLARIFY FIRE REVIEW
 COMMENT. IS THIS GOING TO BE ALL ONE
 TENANT? ACESS FOR PANEL?
  
 5)NOTE: PLEASE CLARIFY SQ FT IN LOAD
 CALCS. 220-3,220-10,220-11,,,,
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-10-01 Cont ID  
Sent By mcarsill Date 2002-10-01 Time 17:13 Rev Time 0.00
Received By mcarsill Date 2002-10-01 Time 17:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-08-22 Cont ID  
Sent By mcarsill Date 2002-08-22 Time 14:20 Rev Time 0.00
Received By mcarsill Date 2002-08-22 Time 14:20 Sent To  
Notes
2002-08-22 00:00:001) DOORS # 2 AND # 5 ARE TO BE AT
 LEAST 20 MINUTE FIRE RATED. THESE
 DOORS ARE TO BE EQUIPPED WITH
 SELF-CLOSING DEVICES TO ENSURE
 THAT THE DOORS LATCH.
  
 2) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION INFORMATION.
  
 3) ARE THE OFFICES GOING TO BE USED
 FOR SEPARATE TENANTS OR WILL THEY
 BE USED FOR SEPARATE TENANTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-09-03 Time 14:22 Rev Time 0.00
Received By csiegber Date 2003-09-03 Time 14:22 Sent To M
Notes
2003-09-03 00:00:00TO PK DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-19 Cont ID  
Sent By shernand Date 2003-06-19 Time 15:19 Rev Time 0.00
Received By shernand Date 2003-06-19 Time 15:19 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2003-09-23 Cont ID  
Sent By pkrauss Date 2003-09-23 Time 11:09 Rev Time 0.35
Received By pkrauss Date 2003-09-23 Time 11:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2003-09-11 Cont ID  
Sent By hmoser Date 2003-09-11 Time 14:10 Rev Time 0.50
Received By hmoser Date 2003-09-11 Time 14:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2003-07-02 Cont ID  
Sent By csiegber Date 2003-09-03 Time 14:22 Rev Time 0.30
Received By pkrauss Date 2003-07-02 Time 10:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2003-07-01 Cont ID  
Sent By pkrauss Date 2003-07-01 Time 08:47 Rev Time 0.30
Received By pkrauss Date 2003-07-01 Time 08:47 Sent To  
Notes
2003-07-01 00:00:00DENIED:
  
 ORIGANL PLANS SUBMITTED ARE SIGNED &
 SEALED BY ARCHITECT.ALL REVISIONS
 ARE TO BE SIGNED AND SEALED ALSO AS PER
 FLORIDA STATUES 481.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-10-15 Cont ID  
Sent By shernand Date 2003-06-19 Time 15:19 Rev Time 0.50
Received By hmoser Date 2002-10-09 Time 14:57 Sent To  
Notes
2002-10-09 00:00:00PASS/PRIVISO
 1) NEED FAN SHUTDOWN ON A/C #3
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-09-06 Cont ID  
Sent By pkrauss Date 2002-09-06 Time 14:26 Rev Time 0.35
Received By pkrauss Date 2002-09-06 Time 14:18 Sent To  
Notes
2002-09-06 00:00:00DENIED:
  
 1.PLEASE PROVIDE OUTSIDE AIR CALCS AS
 PER 2001 FBC(M) TABLE 403.3.
  
 2.AS PER 2001 FBC(M) 601.4, PRESSURE
 DIFFERENTIALS ACROSS CLOSED DOORS
 WHERE RETURNS ARE CENTRALLY LOCATED
 SHALL BE LIMITED TO .001 WC OR LESS.
 PLEASE PROVIDE AIR DUCT PATHWAYS OR
 AIR TRANSFER PATHWAYS FROM THE HIGH
 PRESSURE ZONE TO THE LOW ZONE.
  
 3.PROVIDE FAN SHUTDOWN BY DUCT SMOKE
 DETECTORS IN ACCORDANCE WITH 2001
 FBC(M) 606.2.2.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-10-12 Cont ID  
Sent By kstevens Date 2002-10-12 Time 12:51 Rev Time 0.00
Received By kstevens Date 2002-10-12 Time 12:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-08-31 Cont ID  
Sent By kstevens Date 2002-08-31 Time 08:45 Rev Time 0.00
Received By kstevens Date 2002-08-31 Time 08:45 Sent To  
Notes
2002-08-31 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) SHT A2 DETAIL #1 HEIGHT OF SINK SHALL
 COMPLY WITH 11-4.24.2. ALSO SHOW DETAIL
 FOR 11-4.24.3 KNEE CLEARANCE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377