Rev No 3 Status P Date 2003-09-02 Cont ID  
Sent By sthyng Date 2003-09-02 Time 09:37 Rev Time 2.00
Received By sthyng Date 2003-09-02 Time 09:37 Sent To  
Notes
2003-09-02 00:00:00****PROVISO*****
 PROVIDE AN ENGINEER'S LETTER TO CERTIFY
 THE EXISTING SLAB AND FOOTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-08-12 Cont ID  
Sent By sthyng Date 2003-08-12 Time 09:02 Rev Time 1.00
Received By sthyng Date 2003-08-12 Time 09:02 Sent To  
Notes
2003-08-12 00:00:00*****CORRECTIONS*******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEE PREVIOUS CORRECTION LIST ITEM
 #2, SIGN OWNER/AGENT LINE OF THE ENERGY
 CALC.
  
 2.)SEE PREVIOUS CORRECTION LIST, ITEM
 #8.THIS AREA IS ONE OF QUESTIONABLE
 SOILS.PROVIDE AN ENGINEER'S REPORT
 CERTIFYING THE FOOTERS AND SLAB.
  
 3.)ITEM #5 WAS NOT ADDRESSED.SHOW
 OPENINGS BETWEEN THE EXISTING HOUSE AND
 PORCH.ARE THESE OPENINGS TO BE
 ALTERED?IF NOT, IMPACT PROTECTION IS
 OPTIONAL.IF THEY ARE BEING CHANGED
 (EX: DOOR REMOVED), IMPACT PROTECTION
 IS REQUIRED FBC1606.1.4, FBC3401.7.2.4.
  
 4.)AS THIS IS AN UNCONVENTIONAL
 DESIGN (TIE BEAM ATTACHED TO WOOD BEAM),
 HAVE A STRUCTURAL ENGINEER CERTIFY
 THE DESIGN.
  
 5.)SEE PREVIOUS CORRECTION LIST, ITEM
 16.A FIRESTOP WAS SHOWN IN THE
 ROOF JOISTS.SHOW FIRESTOP FOR THE
 WALLS, FBC705.3.1.
  
 6.)SEE PREVIOUS CORRECTION LIST, ITEM
 #17.WALL SECTION SHOWS A 1X8, NOTE AT
 TOP LEFT OF PLAN SHOWS A 2X8.
  
 7.)REFERENCE IS MADE TO "FL BLDG CODE
 3002".REVISE.
  
 8.)PROVIDE WIND DESIGN INFORMATION
 ON THE PLAN AS REQUIRED FBC1606.1.7.
  
 9.)PROVIDE AREA CALCULATIONS ON THE
 PLAN; EXISTING AND PROPOSED, NEW TOTAL.
  
 10.) WHEN RESUBMITTING, SUBMIT ALL OLD
 SHEETS AND CLOUD ALL CHANGES TO THE
 PLAN.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-18 Cont ID  
Sent By dbaxter Date 2003-08-11 Time 15:49 Rev Time 1.50
Received By sthyng Date 2003-04-18 Time 17:37 Sent To M
Notes
2003-04-18 00:00:00**********CORRECTIONS************
  
 1.)SUBMIT TWO COPIES OF ALL DOCUMENTA-
 TION; PRODUCT APPROVALS, ENERGY CALCS.
  
 2.)SIGN THE ENERGY CALCS ON THE
 OWNER/AGENT LINE.
  
 3.)BEFORE A PERMIT TO CONSTRUCT MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 4.)PROVIDE TWO COPIES OF PRODUCT
 APPROVALS FOR THE WINDOW MULLIONS AND
 HURRICANE SHUTTERS.
  
 5.)PROTECTION FOR WINDOWS REQUIRED
 PER FBC 1606.1.4, FBC 3401.7.2.4.
  
 6.)WHERE THE SLIDING GLASS DOOR IS
 BEING REMOVED AND THE SINGLE HUNG
 WINDOWS INSTALLED, WHAT ROOM IS AT THAT
 LOCATION?PROVIDE A STRUCTURAL DETAIL
 FOR THE INFILL, INCLUDING ALL REINFORCE-
 MENT AND HOW YOU ARE TIEING INTO THE
 EXISTING STRUCTURE.
  
 7.)PROVIDE INFORMATION ABOUT THE
 EXISTING STRUCTURAL COLUMNS - MATERIAL
 AND ATTACHMENT.
  
 8.)PROVIDE STRUCTURAL INFORMATION
 ABOUT THE CONCRETE SLAB (EXISTING
 FOOTERS).
  
 9.) THE WALL SECTION DOES NOT SHOW ANY
 VERTICAL OR HORIZONTAL REINFORCEMENT.
  
 10.)CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC, 2111.1.9 WATERSTOP - WHERE
 EXTERIOR WALL MASONRY UNITS BEAR ON A
 CONCRETE FLOOR SURFACE, A 1.5 INCH
 RECESS SHALL BE PROVIDED TO MINIMIZE
 WATER INTRUSION INTO FINISHED AREA.
  
 11.)SHOW HOW LATERAL SUPPORT AT THE
 TOP OF THE BOND BEAM WILL BE PROVIDED.
  
 12.)HOW WILL THE BLOCK TIE INTO THE
 EXISTING CONCRETE?HOW WILL THE BLOCK
 INFILL TIE INTO THE EXISTING COLUMNS?
  
 13.)A BOND BEAM IS SHOWN BUT NOT
 DESCRIBED (NO SIZE FOR REINFORCEMENT
 GIVEN).PLEASE REVISE WALL SECTION.
  
 14.)ADDITIONAL PERMITS ARE REQUIRED
 (ELECTRIC AND MECHANICAL).
  
 15.)HOW ARE YOU PROVIDING STRUCTURAL
 SUPPORT AT THE WINDOWS AND DOOR
 LOCATIONS?
  
 16.)FIREBLOCKING REQUIRED FBC705.3.1.
  
 17.)CLARIFY THE PURPOSE OF THE PT1X8.
 HOW WILL THAT TIE INTO THE EXISTING WOOD
 BEAM?
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-01 Cont ID  
Sent By btrobaug Date 2003-05-01 Time 14:40 Rev Time 0.33
Received By btrobaug Date 2003-05-01 Time 14:40 Sent To B
Notes
2003-05-01 00:00:00TO SAMANTHA---NEEDS ELEC.PERMIT./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-11 Cont ID  
Sent By dbaxter Date 2003-08-11 Time 15:49 Rev Time 0.00
Received By dbaxter Date 2003-08-11 Time 15:49 Sent To B
Notes
2003-08-11 00:00:00 
 TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-16 Cont ID  
Sent By shernand Date 2003-04-16 Time 09:27 Rev Time 0.00
Received By shernand Date 2003-04-16 Time 09:27 Sent To B
Notes
2003-04-16 00:00:00MISC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-14 Cont ID  
Sent By shernand Date 2003-04-14 Time 08:02 Rev Time 0.00
Received By shernand Date 2003-04-14 Time 08:02 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-05-01 Cont ID  
Sent By sthyng Date 2003-04-18 Time 18:26 Rev Time 0.10
Received By pkrauss Date 2003-05-01 Time 13:56 Sent To  
Notes
2003-05-01 00:00:00NO MECHANICAL PLANS WITH "SCREENED
 ENCLOSURE" PERMIT

Review Stop Z ZONING
Rev No 3 Status P Date 2003-04-14 Cont ID  
Sent By sgraham Date 2003-04-14 Time 12:44 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2002-09-19 Cont ID  
Sent By shernand Date 2003-04-14 Time 08:02 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-09-19 00:00:00DENIED AGAIN, INDICATE ON THE SURVEY
 WHERE SCREEN ROOM WILL BE LOCATED

Review Stop Z ZONING
Rev No 1 Status F Date 2002-08-27 Cont ID  
Sent By sgraham Date 2002-08-27 Time 13:57 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-08-27 00:00:00NEED SURVEY AND 2-SETS OF PLANS SHOW
 CONSTRUCTION OF THE SCREEN ROOM