Plan Review Details - Permit 02080921
| Plan Review Stops For Permit 02080921 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-10-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-27 |
Time |
15:25 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2002-10-23 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-09-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-08-27 |
Time |
11:51 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2002-09-07 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2002-09-07 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 02080921 | | | ADD: *****LIBERTY BAY***** | | | ****MODEL B***** | | | CONT: HOME DYNAMICS CONSTRUCTION | | | TEL: (954)275-8569 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1) SHEET A-1 NOTE: MONOLITHIC CONCRETE | | | FOUNDATION WITHOUT HOOK BARS DESIGNED BY | | | RATIONAL ANLYSIS ACI 318-89. | | | ACI 530.8.5.2 EMBEDDMENT LENGHT MIN 12" | | | | | | 2) PLANS INDICATE BEING DESIGNED TO | | | 130 MPH. THE CITY IS LOCATED IN A 140 | | | MPH WIND ZONE.SEE A-2 BUILDING DATA. | | | DESIGN NOTES, SEE WIND LOADS PER | | | CHAP. 6 SHOULD BE CHAP 16. | | | DESIGN NOTES, DESIGNED TO ASCE 7- | | | NO YEAR NOTED!!!!! | | | | | | 3) SHEET A-3 NAILING FOR ROOF SHEATHING | | | FOR MEAN ROOF HEIGHT <25' | | | ZONES 1 & 28D COMMON | | | 6" O.C. EDGES & 6" O.C. INTERMEDIATES | | | ZONE 38D COMMONS | | | 4" O.C. EDGES & 6" O.C. INTERMEDIATES | | | | | | 4) PROVIDE MISSING KEY PLAN FOR STORM | | | SHUTTER INSTALLATION SCHEDULE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096 X 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-10-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-23 |
Time |
18:12 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-08-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-08-27 |
Time |
11:50 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2002-08-27 |
Time |
08:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-27 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-27 |
Time |
15:25 |
Sent To |
B |
|
| Notes |
| 2003-10-27 00:00:00 | TO JW DESK/REV/MASTERED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-07 |
Time |
12:41 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-11-07 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-10-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-10-24 |
Time |
12:56 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-10-24 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-08-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-08-24 |
Time |
09:20 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-08-24 |
Time |
09:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-10-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-10-24 |
Time |
08:05 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-10-24 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2002-10-24 00:00:00 | RESUB PLUMBING OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-08-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-23 |
Time |
18:12 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-08-20 |
Time |
19:26 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy