Plan Review Details - Permit 02080761
Plan Review Stops For Permit 02080761
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-22 Cont ID  
Sent By hpiskura Date 2002-10-22 Time 11:53 Rev Time 0.00
Received By hpiskura Date 2002-10-22 Time 11:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status I Date 2002-08-22 Cont ID  
Sent By hpiskura Date 2002-08-22 Time 08:15 Rev Time 0.00
Received By hpiskura Date 2002-08-22 Time 08:32 Sent To  
Notes
2002-08-22 00:00:00THE TWO UNDATED, UNSIGNED TRACINGS,
 FROMTHE FS-1 MERLINO ASSOCIATES PLANS
 ARE NOT COMPLETELY CLEAR AS TO THE
 SCOPE OF WORK TO BE ACCOMPLISHED.
  
 A CONSTRUCTION DETAIL FOR PARTITIONS
 WILL BE NECESSARY INCLUDING MATERIALS,
 TERMINATION POINTS, AND OTHER PERINENT
 INFORMATION.
  
 THE PLAN WILL NEED DIMENSIONS SHOWN.
  
 IF THE FOOD SERVICE EQUIPMENT SHOWN IS
 INTENDED TO BE INSTALLED, THEN THE
 NECESSARY SUPPORT INFORMATION MUST BE
 SHOWN ONTHE PLANS, IE MECHANICAL,
 PLUMBING AND ELECTRIC SERVICES.
  
 WHAT IS THE ADJACENT AREA SHOWN USED
 FOR?IS TENANT SEPARATION EXISTING OR
 TO BE PROVIDED? WHAT IS THE DOOR SHOWN
 OPENING INTO THE CORRIDOR AREA NEAR THE
 TOILET ROOM?
  
 SEE FBC 104.3.1.1 FOR A COMPREHENSIVE
 LIST OF THE MINIMUM ITEMS REQUIRED FOR
 PLAN REVIEW AND SUBSEQUENT PERMITTING AS
 WELL AS FBC 104.2.
  
 IF THE FOOD EQUIPMENT IS TO BE
 INSTALLED THEN AN ARCHITECT OR ENGINEER
 WILL BE REQUIRED TO PREPARE THE PLANS.
 FBC 104.1.3.

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2002-09-24 Cont ID  
Sent By dpalmer Date 2002-09-24 Time 07:18 Rev Time 0.25
Received By dpalmer Date 2002-09-24 Time 07:18 Sent To  
Notes
2002-09-24 00:00:00************ NOTE ***********
  
 NO ELECTRICAL PLANS SUBMITTED.

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2002-08-21 Cont ID  
Sent By dpalmer Date 2002-08-21 Time 18:00 Rev Time 0.25
Received By dpalmer Date 2002-08-21 Time 18:00 Sent To  
Notes
2002-08-21 00:00:00NO REVIEW TO BE DONE. ELECTRICAL TO
 REMAIN AS EXISTING PER CONTRACTOR.
 ANY ELEC WORK TO SUBMIT FOR PERMIT
 SEPARATELY.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-08-14 Cont ID  
Sent By dpalmer Date 2002-08-14 Time 19:57 Rev Time 0.00
Received By dpalmer Date 2002-08-14 Time 19:57 Sent To  
Notes
2002-08-14 00:00:00*************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT NOT ENOUGH
 INFORMATION WAS SUBMITTED FOR REVIEW?
 PANELS/CIRCUITING/ ETC .
 2)NOTE: PLEASE NOTE PLANS DATED 1993
 WERE SUBMITTED?
 PLEASE NOTE TWO SETS ARE NEEDED TO BE
 SUBMITTED FOR PERMIT.
 PLEASE NOTE THAT PLANS THAT ARE DONE
 BY AN ARCH/ENGINEER ARE REQ`D BY FS/FAC
 TO BE SIGNED ,DATED AND SEALED.471.025,
 481.221.
  
 3)NOTE: PLEASE NOTE THAT PERMIT
 APPLICATION HAS NO DESCRIPTION FOR WORK
 TO BE DONE.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-08-23 Cont ID  
Sent By lmartine Date 2002-08-23 Time 09:21 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-10-24 Cont ID  
Sent By mcarsill Date 2002-10-24 Time 11:32 Rev Time 0.00
Received By mcarsill Date 2002-10-24 Time 11:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2002-09-24 Cont ID  
Sent By mcarsill Date 2002-09-24 Time 15:31 Rev Time 0.00
Received By mcarsill Date 2002-09-24 Time 15:31 Sent To  
Notes
2002-09-24 00:00:001) PLANS AGAIN ARE INCOMPLETE. PREVIOUS
 REQUIRED INFORMATION NOT DOCUMENTED ON
 THE PLANS. PLEASE REVISE THE PLANS AS
 NECESSARY. PLEASE SEE PREVIOUS PLAN
 REVIEW COMMENTS FROM CONSTRUCTION
 SERVICES AND FIRE RESCUE.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-08-22 Cont ID  
Sent By mcarsill Date 2002-08-22 Time 10:24 Rev Time 0.00
Received By mcarsill Date 2002-08-22 Time 10:24 Sent To  
Notes
2002-08-22 00:00:001) PLANS THAT WERE SUBMITTED ARE FROM
 1993.
  
 2) NO INFORMATION PROVIDED FOR TENANT
 SEPARATION WALLS.
  
 3) NO EMERGENCY LIGHTING EQUIPMENT
 SHOWN ON THE PLANS.
  
 4) SEPARATE PLANS AND PERMITS REQUIRED
 FOR ANY NEW HOOD, DUCT, AND
 EXTINGUISHING SYSTEMS.
  
 5) PLEASE INDICATE INTERIOR FINISH
 INFORMATION FOR WALLS AND CEILINGS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-08-23 Cont ID  
Sent By lmartine Date 2002-08-23 Time 09:21 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-08-23 Cont ID  
Sent By lmartine Date 2002-08-23 Time 09:22 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2002-08-23 Cont ID  
Sent By lmartine Date 2002-08-23 Time 09:22 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***