Plan Review Details - Permit 02080635
Plan Review Stops For Permit 02080635
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-09-17 Cont ID  
Sent By hpiskura Date 2002-09-17 Time 14:55 Rev Time 0.00
Received By hpiskura Date 2002-09-17 Time 14:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-08-23 Cont ID  
Sent By rbrown Date 2002-08-23 Time 15:45 Rev Time 0.00
Received By rbrown Date 2002-08-23 Time 15:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-09-11 Cont ID  
Sent By dpalmer Date 2002-09-11 Time 18:09 Rev Time 0.50
Received By dpalmer Date 2002-09-11 Time 18:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-08-14 Cont ID  
Sent By dpalmer Date 2002-08-14 Time 19:37 Rev Time 0.00
Received By dpalmer Date 2002-08-14 Time 19:37 Sent To  
Notes
2002-08-14 00:00:00************* UNSAT *****************
  
 1)NOTE: PLEASE NOTE/CLARIFY THE USE OF
 EMT TO TRANSFORMER. PLEASE NOTE CONNECT-
 ION DUE TO VIBRATION.
  
 2)NOTE: PLEASE NOTE GROUNDING PER 450-10
 AND 250-30 REQ`D BONDING JUMPER.
  
 3)NOTE: PLEASE SHOW LOAD CALCULATIONS
 PER 220-3,220-10,220-13 ETC
 PLEASE SHOW ALL CONTINUOUS LOADS AT 125%
 215-3,230-42 ETC.
  
 4)NOTE: PLEASE SUBMIT AIC RATING FOR NEW
 MAIN DISCONNECT. AIC RATING IS NOTED FOR
 PANELS. 110-9
  
 5)NOTE: PLEASE CLARIFY SHOW WINDOW RECEP
 PER 210-62
  
 6)NOTE: PLEASE CLARIFY COVER SHEET SHOWS
 SETS TO INCLUDE AN E-4? E-1,2,3 WAS ONLY
 ONES SUBMITTED?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRCIAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-08-09 Cont ID  
Sent By mcarsill Date 2002-08-09 Time 15:28 Rev Time 0.00
Received By mcarsill Date 2002-08-09 Time 15:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-08-23 Cont ID  
Sent By pkrauss Date 2002-08-23 Time 12:58 Rev Time 0.35
Received By pkrauss Date 2002-08-23 Time 12:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-09-23 Cont ID  
Sent By kstevens Date 2002-09-23 Time 11:15 Rev Time 0.00
Received By kstevens Date 2002-09-23 Time 11:14 Sent To  
Notes
2002-09-23 00:00:00ADJUSTED MINIMUM FACILITIES PER TENANT

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-08-15 Cont ID  
Sent By kstevens Date 2002-08-15 Time 09:38 Rev Time 0.00
Received By kstevens Date 2002-08-15 Time 09:38 Sent To  
Notes
2002-08-15 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) PLEASE PROVIDE CALCULATIONS FOR MIN-
 IMUM FACILITIES PER TABLE 403.1. SHOW
 SQUARE FOOTAGE FOR SPACE BEING OCCUPIED.
  
 2) SHT A-4 WATER COOLER SHALL COMPLY
 WITH ARI-1010. PLEASE PROVIDE MANUF. IN-
 FORMATION.
  
 3) SHT P-1 WATER RISER DIAGRAM, AIR
 CHAMBERS ARE NOT APPROVED. WATER HAMMER
 ARRESTORS SHALL BE INSTALLED WHERE REQ-
 UIRED PER SEC 604.9 AND LOCATED NEAR THE
 FIXTURES IN AN "EFFECTIVE RANGE" NOT AT
 THE TOP OF DROPS AS SHOWN. PDI-WH 201 &
 MANUF. INSTALL. INSTRUCTIONS.
  
 4) SHT P-2 PLUMBING SPECIFICATIONS #7,
 AIR CHAMBERS ARE NOT APPROVED. PLEASE
 DELETE REFERENCE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377