Plan Review Details - Permit 02080635
| Plan Review Stops For Permit 02080635 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-09-17 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-09-17 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-09-17 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-08-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-08-23 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-08-23 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-11 |
Time |
18:09 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-09-11 |
Time |
18:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-08-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-08-14 |
Time |
19:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-08-14 |
Time |
19:37 |
Sent To |
|
|
| Notes |
| 2002-08-14 00:00:00 | ************* UNSAT ***************** | | | | | | 1)NOTE: PLEASE NOTE/CLARIFY THE USE OF | | | EMT TO TRANSFORMER. PLEASE NOTE CONNECT- | | | ION DUE TO VIBRATION. | | | | | | 2)NOTE: PLEASE NOTE GROUNDING PER 450-10 | | | AND 250-30 REQ`D BONDING JUMPER. | | | | | | 3)NOTE: PLEASE SHOW LOAD CALCULATIONS | | | PER 220-3,220-10,220-13 ETC | | | PLEASE SHOW ALL CONTINUOUS LOADS AT 125% | | | 215-3,230-42 ETC. | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATING FOR NEW | | | MAIN DISCONNECT. AIC RATING IS NOTED FOR | | | PANELS. 110-9 | | | | | | 5)NOTE: PLEASE CLARIFY SHOW WINDOW RECEP | | | PER 210-62 | | | | | | 6)NOTE: PLEASE CLARIFY COVER SHEET SHOWS | | | SETS TO INCLUDE AN E-4? E-1,2,3 WAS ONLY | | | ONES SUBMITTED? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRCIAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-08-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-08-09 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-08-09 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-08-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-08-23 |
Time |
12:58 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-08-23 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-09-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-09-23 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-09-23 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2002-09-23 00:00:00 | ADJUSTED MINIMUM FACILITIES PER TENANT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-08-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-08-15 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-08-15 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2002-08-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) PLEASE PROVIDE CALCULATIONS FOR MIN- | | | IMUM FACILITIES PER TABLE 403.1. SHOW | | | SQUARE FOOTAGE FOR SPACE BEING OCCUPIED. | | | | | | 2) SHT A-4 WATER COOLER SHALL COMPLY | | | WITH ARI-1010. PLEASE PROVIDE MANUF. IN- | | | FORMATION. | | | | | | 3) SHT P-1 WATER RISER DIAGRAM, AIR | | | CHAMBERS ARE NOT APPROVED. WATER HAMMER | | | ARRESTORS SHALL BE INSTALLED WHERE REQ- | | | UIRED PER SEC 604.9 AND LOCATED NEAR THE | | | FIXTURES IN AN "EFFECTIVE RANGE" NOT AT | | | THE TOP OF DROPS AS SHOWN. PDI-WH 201 & | | | MANUF. INSTALL. INSTRUCTIONS. | | | | | | 4) SHT P-2 PLUMBING SPECIFICATIONS #7, | | | AIR CHAMBERS ARE NOT APPROVED. PLEASE | | | DELETE REFERENCE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
|