Plan Review Details - Permit 02080275
Plan Review Stops For Permit 02080275
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-09-17 Cont ID  
Sent By hpiskura Date 2002-09-17 Time 13:58 Rev Time 0.00
Received By hpiskura Date 2002-09-16 Time 11:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-08-26 Cont ID  
Sent By hpiskura Date 2002-08-26 Time 10:15 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2002-08-26 00:00:00BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO PALM
 BEACN COUNTY, THE PERMIT PLANS STAMPED
 BY THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.CALL 561-233-5025 FOR
 MORE INFORMATION.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-20 Cont ID  
Sent By btrobaug Date 2002-12-20 Time 15:34 Rev Time 0.25
Received By btrobaug Date 2002-12-20 Time 15:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-08-29 Cont ID  
Sent By dpalmer Date 2002-08-29 Time 17:00 Rev Time 1.00
Received By dpalmer Date 2002-08-29 Time 17:00 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2002-09-17 Cont ID  
Sent By btrobaug Date 2002-10-30 Time 17:21 Rev Time 5.00
Received By mamini Date 2002-09-17 Time 13:34 Sent To  
Notes
2002-09-17 00:00:00N/A
 1. SEE PERMIT # 02090865 FOR CIVIL/SITE
 REVIEW AND PERMITTING.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2002-09-12 Cont ID  
Sent By mamini Date 2002-08-19 Time 09:23 Rev Time 5.00
Received By mamini Date 2002-08-19 Time 09:23 Sent To  
Notes
2002-08-19 00:00:00FAILED:
 1. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATIONS AND FEES FOR UNDERGROUND
 UTILITIES AND SITE WORKS AT THE TIME OF
 ACTUAL PERMITTING WILL BE REQUIRED.
 2. REFUSE ENCLOSURE GATES SHOULD BE
 12'-6" IF GARBAGE IS TO BE PICKED UP BY
 THE CITY.
 3. SHEET C-3 REFERS TO C-7 FOR DUMPSTER
 ENCLOSURE DETAILS, IT SHOULD REFER TO
 SHEET C-6
 4. EXISTING BALLARD SHOWN AT CORNER,
 ENTRANCE TO MCDONALD'S SITE SHOULD BE
 REMOVED, PLEASE VERIFY.
 5. PLEASE PROVIDE CALCULATION FOR STORM
 WATER QUALITY AT THE TIME OF ACTUAL
 PERMITTING.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-09-24 Cont ID  
Sent By mcarsill Date 2002-09-24 Time 12:17 Rev Time 0.00
Received By mcarsill Date 2002-09-24 Time 12:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-08-27 Cont ID  
Sent By mcarsill Date 2002-08-27 Time 12:32 Rev Time 0.00
Received By mcarsill Date 2002-08-27 Time 12:32 Sent To  
Notes
2002-08-27 00:00:001) BUILDING APPEARS TO BE LOCATED
 IN THE CITY FIRE LIMITS. CERTAIN
 RESTRICTIONS APPLY. PLEASE SEE
 APPENDIX F OF THE LOCAL AMENDMENTS TO
 THE FLORIDA BUILDING CODE.
  
 2) BUILDING ADDRESS REQUIRED TO BE
 AT LEAST 6" HIGH.
  
 3) SEPARATE PLANS AND PERMITS REQUIRED
 FOR ANY HOOD,DUCT,AND FIRE SUPPRESSION
 SYSTEMS PLANNED FOR INSTALLATION.
  
 4) PLEASE PROVIDE A LIFE SAFETY
 PLAN FOR REVIEW.
  
 5) PLEASE INDICATE LOCATIONS OF FIRE
 HYDRANTS WITHIN THE VICINITY OF THE
 PROPOSED SITE.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 10:09 Rev Time 0.00
Received By dpalmer Date   Time   Sent To P
Notes
2002-12-23 00:00:00TO PLUMB INBOX
2002-10-31 00:00:00REFER TO 02090865./
2002-10-30 00:00:00TO ENG IN BOX./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-08-26 Cont ID  
Sent By pkrauss Date 2002-08-26 Time 11:44 Rev Time 0.50
Received By pkrauss Date 2002-08-26 Time 11:44 Sent To  
Notes
2002-08-26 00:00:00PROVISO:
  
 SEPARATE PLANS & PERMITS REQUIRED FOR
 WALK IN COOLER/FREEZER, HOOD & FIRE
 SUPRESSION.PLEASE PROVIDE PLANS WITH
 PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-01-09 Cont ID  
Sent By kstevens Date 2003-01-09 Time 09:15 Rev Time 1.00
Received By kstevens Date 2003-01-09 Time 09:15 Sent To  
Notes
2003-01-09 00:00:00REVISION OK - SANT. RISER & GREASE RISER
 BOTH REROUTED TO OTHER SIDE OF BLDG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-09-27 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 10:09 Rev Time 0.00
Received By kstevens Date 2002-09-23 Time 18:37 Sent To  
Notes
2002-09-27 00:00:00PASSED/PROVISO
  
 GREASE TRAPS SHALL BE SIZED BY R. COMPO

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-08-26 Cont ID  
Sent By kstevens Date 2002-08-26 Time 17:51 Rev Time 0.00
Received By kstevens Date 2002-08-26 Time 17:51 Sent To  
Notes
2002-08-26 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) GREASE TRAP SHALL BE SIZED BY THE
 ENVIRONMENTAL COMPLIANCE MANAGER. PLEASE
 CONTACT RODNEY COMPO @ (561) 837-4074
 UTILITY ORD #2938-96
 2) SHT C-5A GREASE/WATER SEPARATOR DE-
 TAIL, INFLUENT & EFFLUENT C/O'S SHALL BE
 2-WAY C/O'S.
 3) SHT P7 GREASE TRAP DETAIL, SEE ATTACH
 ED WPB UTILITY APPROVED GREASE TRAP DE-
 TAIL.
 4) BACKFLOW REQUIRED ON WATER SERVICE.
 (SEE SHT P6 WATER SERVICE DETAIL)
 PLUMBING CONTRACTOR SHALL CUT IN TEE AND
 INSTALL VALVE FOR IRRIGATION CONTRACTOR
 IF SEPARATE BACKFLOW IS NOT INSTALLED AT
 METER.
 5) SHT P1, ALL INDIRECT WASTE SHALL BE
 DRAINED TO A FLOOR SINK, NOT TO FLOOR
 DRAINS. (SEE FREEZER/COOLER, ICE MACHINE
 SODA DISPENSER ECT)
 6) SHT P2, WATER FILTER SHALL BE NSF
 APPROVED. PLEASE PROVIDE MANUF. INFO.
 7) SHT P2, WATER RISER DIAGRAM, WATER
 HAMMER ARRESTORS SHALL BE INSTALLED PER
 604.9 AT ALL QUICK CLOSING VALVES. (ICE
 MACHINES, WASH MACHINES, ECT.) ARRESTORS
 SHALL BE LOCATED NEAR THE FIXTURES IN AN
 "EFFECTIVE RANGE" NOT AT THE TOP OF DROP
 PDI-WH 201 AND MANUF INSTALLATION INSTR-
 UCTIONS.
 8) SHT P6 WATER HEATER DETAIL, BOTTOM
 FED WATER HEATERS SHALL HAVE A VACUUM
 RELIEF VALVE INSTALLED. SEC 504.2
 9) SHT P6 WATER HEATER DETAIL, THE DIS-
 CHARGE LINE FROM THE P/T RELIEF VALVE
 SHALL NOT HAVE ANY TRAPPED SECTIONS AND
 SHALL HAVE A VISIBLE AIR GAP OR AIR GAP
 FITTING LOCATED IN THE SAME ROOM AS THE
 WATER HEATER.
 10) SHT P6 HUB DRAIN NOT APPROVED, FLOOR
 SINK REQD FOR INDIRECT WASTE PER SEC
 802.3. PLEASE DELETE DETAIL.
 11) SHT P7 FUNNEL FLOOR DRAIN NOT APP-
 ROVED. PLEASE DELETE DETAIL.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-15 Cont ID  
Sent By sgraham Date 2002-08-15 Time 15:35 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***