| Plan Review Stops For Permit 02080275 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-09-17 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-09-17 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-09-16 |
Time |
11:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-08-26 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-08-26 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-08-26 00:00:00 | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACN COUNTY, THE PERMIT PLANS STAMPED | | | BY THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-12-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-20 |
Time |
15:34 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2002-12-20 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-08-29 |
Time |
17:00 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-08-29 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2002-09-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-30 |
Time |
17:21 |
Rev Time |
5.00 |
| Received By |
mamini |
Date |
2002-09-17 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2002-09-17 00:00:00 | N/A | | | 1. SEE PERMIT # 02090865 FOR CIVIL/SITE | | | REVIEW AND PERMITTING. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-09-12 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-08-19 |
Time |
09:23 |
Rev Time |
5.00 |
| Received By |
mamini |
Date |
2002-08-19 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2002-08-19 00:00:00 | FAILED: | | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | | APPLICATIONS AND FEES FOR UNDERGROUND | | | UTILITIES AND SITE WORKS AT THE TIME OF | | | ACTUAL PERMITTING WILL BE REQUIRED. | | | 2. REFUSE ENCLOSURE GATES SHOULD BE | | | 12'-6" IF GARBAGE IS TO BE PICKED UP BY | | | THE CITY. | | | 3. SHEET C-3 REFERS TO C-7 FOR DUMPSTER | | | ENCLOSURE DETAILS, IT SHOULD REFER TO | | | SHEET C-6 | | | 4. EXISTING BALLARD SHOWN AT CORNER, | | | ENTRANCE TO MCDONALD'S SITE SHOULD BE | | | REMOVED, PLEASE VERIFY. | | | 5. PLEASE PROVIDE CALCULATION FOR STORM | | | WATER QUALITY AT THE TIME OF ACTUAL | | | PERMITTING. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-09-24 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-09-24 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-09-24 |
Time |
12:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-08-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-08-27 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-08-27 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2002-08-27 00:00:00 | 1) BUILDING APPEARS TO BE LOCATED | | | IN THE CITY FIRE LIMITS. CERTAIN | | | RESTRICTIONS APPLY. PLEASE SEE | | | APPENDIX F OF THE LOCAL AMENDMENTS TO | | | THE FLORIDA BUILDING CODE. | | | | | | 2) BUILDING ADDRESS REQUIRED TO BE | | | AT LEAST 6" HIGH. | | | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY HOOD,DUCT,AND FIRE SUPPRESSION | | | SYSTEMS PLANNED FOR INSTALLATION. | | | | | | 4) PLEASE PROVIDE A LIFE SAFETY | | | PLAN FOR REVIEW. | | | | | | 5) PLEASE INDICATE LOCATIONS OF FIRE | | | HYDRANTS WITHIN THE VICINITY OF THE | | | PROPOSED SITE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-23 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
| 2002-12-23 00:00:00 | TO PLUMB INBOX | | 2002-10-31 00:00:00 | REFER TO 02090865./ | | 2002-10-30 00:00:00 | TO ENG IN BOX./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-08-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-08-26 |
Time |
11:44 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2002-08-26 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2002-08-26 00:00:00 | PROVISO: | | | | | | SEPARATE PLANS & PERMITS REQUIRED FOR | | | WALK IN COOLER/FREEZER, HOOD & FIRE | | | SUPRESSION.PLEASE PROVIDE PLANS WITH | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-01-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-09 |
Time |
09:15 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-01-09 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2003-01-09 00:00:00 | REVISION OK - SANT. RISER & GREASE RISER | | | BOTH REROUTED TO OTHER SIDE OF BLDG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-09-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-23 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-09-23 |
Time |
18:37 |
Sent To |
|
|
| Notes |
| 2002-09-27 00:00:00 | PASSED/PROVISO | | | | | | GREASE TRAPS SHALL BE SIZED BY R. COMPO |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-08-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-08-26 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-08-26 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2002-08-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) GREASE TRAP SHALL BE SIZED BY THE | | | ENVIRONMENTAL COMPLIANCE MANAGER. PLEASE | | | CONTACT RODNEY COMPO @ (561) 837-4074 | | | UTILITY ORD #2938-96 | | | 2) SHT C-5A GREASE/WATER SEPARATOR DE- | | | TAIL, INFLUENT & EFFLUENT C/O'S SHALL BE | | | 2-WAY C/O'S. | | | 3) SHT P7 GREASE TRAP DETAIL, SEE ATTACH | | | ED WPB UTILITY APPROVED GREASE TRAP DE- | | | TAIL. | | | 4) BACKFLOW REQUIRED ON WATER SERVICE. | | | (SEE SHT P6 WATER SERVICE DETAIL) | | | PLUMBING CONTRACTOR SHALL CUT IN TEE AND | | | INSTALL VALVE FOR IRRIGATION CONTRACTOR | | | IF SEPARATE BACKFLOW IS NOT INSTALLED AT | | | METER. | | | 5) SHT P1, ALL INDIRECT WASTE SHALL BE | | | DRAINED TO A FLOOR SINK, NOT TO FLOOR | | | DRAINS. (SEE FREEZER/COOLER, ICE MACHINE | | | SODA DISPENSER ECT) | | | 6) SHT P2, WATER FILTER SHALL BE NSF | | | APPROVED. PLEASE PROVIDE MANUF. INFO. | | | 7) SHT P2, WATER RISER DIAGRAM, WATER | | | HAMMER ARRESTORS SHALL BE INSTALLED PER | | | 604.9 AT ALL QUICK CLOSING VALVES. (ICE | | | MACHINES, WASH MACHINES, ECT.) ARRESTORS | | | SHALL BE LOCATED NEAR THE FIXTURES IN AN | | | "EFFECTIVE RANGE" NOT AT THE TOP OF DROP | | | PDI-WH 201 AND MANUF INSTALLATION INSTR- | | | UCTIONS. | | | 8) SHT P6 WATER HEATER DETAIL, BOTTOM | | | FED WATER HEATERS SHALL HAVE A VACUUM | | | RELIEF VALVE INSTALLED. SEC 504.2 | | | 9) SHT P6 WATER HEATER DETAIL, THE DIS- | | | CHARGE LINE FROM THE P/T RELIEF VALVE | | | SHALL NOT HAVE ANY TRAPPED SECTIONS AND | | | SHALL HAVE A VISIBLE AIR GAP OR AIR GAP | | | FITTING LOCATED IN THE SAME ROOM AS THE | | | WATER HEATER. | | | 10) SHT P6 HUB DRAIN NOT APPROVED, FLOOR | | | SINK REQD FOR INDIRECT WASTE PER SEC | | | 802.3. PLEASE DELETE DETAIL. | | | 11) SHT P7 FUNNEL FLOOR DRAIN NOT APP- | | | ROVED. PLEASE DELETE DETAIL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-08-15 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-08-15 |
Time |
15:35 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|