Plan Review Details - Permit 02080120
Plan Review Stops For Permit 02080120
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-08-29 Cont ID  
Sent By lsmith Date 2002-08-29 Time 15:27 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-08-12 Cont ID  
Sent By btrobaug Date 2002-08-09 Time 07:59 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
2002-08-12 00:00:00****FAILED***********
  
 1. NEED CONTRACT TO VERIFY VALUE OF
 PERMIT (LABOR & MATERIALS)
 2. NEED DETAIL SHOWN ON PLANS FOR
 COMPLIANCE OF BARRIER PER FBC2001.
 3. DETAIL OF SLAB & ANCHORING OF POOL
 EQUIPMENT MUST BE SHOWN ON PLANS.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLAN EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-08-09 Cont ID  
Sent By btrobaug Date 2002-08-09 Time 07:59 Rev Time 0.00
Received By btrobaug Date 2002-08-09 Time 07:23 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-08-29 Cont ID  
Sent By pschmitz Date 2002-08-29 Time 07:18 Rev Time 0.75
Received By pschmitz Date   Time   Sent To  
Notes
2002-08-29 00:00:00RE-SUB APPR,PES.

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-08-23 Cont ID  
Sent By pschmitz Date 2002-08-23 Time 06:49 Rev Time 0.75
Received By pschmitz Date   Time   Sent To  
Notes
2002-08-23 00:00:00PLUMBING PLAN REVIEW. DENIED FBC 2001
 1) FBC-2001424.2.6.6.5 WHERE PROVIDED
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 2) FBC-2001424.2.6.6.4 MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR EA
 PUMP. SEPARATED BY A MINIMUM OF 3 FEET
 OR LOCATED ON TWO DIFFERENT PLANES.
 (DETAIL)
 3) FBC-2001 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS561-659-8096X 8233

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-08-08 Cont ID  
Sent By pschmitz Date 2002-08-08 Time 10:30 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-08-08 00:00:00PLUMBING PLAN REVIEW, DENIED FBC 2001
 PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 3) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 4) FBC-2001424.2.6.6.5 WHERE PROVIDED
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 5) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 6) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 END OF COMMENTS PAUL SCHMITZ
 QUESTIONS561-659-8096X8233

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-05 Cont ID  
Sent By sgraham Date 2002-08-05 Time 13:24 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***