Plan Review Details - Permit 02080111
Plan Review Stops For Permit 02080111
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-02-26 Cont ID  
Sent By btrobaug Date 2003-02-26 Time 09:17 Rev Time 0.50
Received By btrobaug Date 2003-02-26 Time 08:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-12-26 Cont ID  
Sent By dpalmer Date 2002-12-26 Time 13:31 Rev Time 0.25
Received By dpalmer Date 2002-12-26 Time 13:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-27 Cont ID  
Sent By btrobaug Date 2002-08-27 Time 17:14 Rev Time 0.00
Received By btrobaug Date 2002-08-27 Time 17:14 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-08-19 Cont ID  
Sent By dpalmer Date 2002-08-19 Time 07:55 Rev Time 0.00
Received By dpalmer Date 2002-08-19 Time 07:54 Sent To B
Notes
2002-08-19 00:00:00********************** UNSAT ***********
  
  
 1)NOTE: PLEASE NOTE NO MAIN SHOWN FOR
 PANEL. PLEASE NOTE SHOWN AS MLO.
 PLEASE SHOW MAIN, PER 225-31
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-09 Cont ID  
Sent By btrobaug Date 2003-01-09 Time 16:36 Rev Time 0.00
Received By btrobaug Date 2003-01-09 Time 16:36 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-15 Cont ID  
Sent By dpalmer Date 2002-11-15 Time 16:32 Rev Time 0.00
Received By dpalmer Date 2002-11-15 Time 16:32 Sent To B
Notes
2002-11-15 00:00:00TO LOU HATTENS DESK

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-01-10 Cont ID  
Sent By pkrauss Date 2003-01-10 Time 11:19 Rev Time 0.25
Received By pkrauss Date 2003-01-10 Time 11:19 Sent To  
Notes
2003-01-10 00:00:00MECH PERMIT 02080168

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-08-15 Cont ID  
Sent By btrobaug Date 2003-01-09 Time 16:37 Rev Time 0.35
Received By pkrauss Date 2002-08-15 Time 07:54 Sent To  
Notes
2002-08-15 00:00:00PROVISO:MECHANICAL PERMIT 02080168
  
 2ND FLOOR AHU CLOSET SHALL NOT BE USED
 FOR STORAGE AS NOT TO BLOCK RETURN AIR.
  
 2001 FBC(M) 402.2 - NATURAL VENTILATION
 FOR OUTSIDE AIR REQUIRMENT. SHOW
 COMPLIANCE FOR THE MINIMUM OPENABLE
 AREATO THE OUTDOORS. (4 PERCENT OF THE
 FLOOR AREA BEING VENTILATED) OR TABLE
 403.3 FOR MECHANICAL VENTILATION.
  
 WHERE MULTIPLE AIR-HANDLING SYSTEMS
 SHARE COMMON SUPPLY OR RETURN AIR DUCTS
 OR PLENUMS WITH A COMBINED DESIGN
 CAPACITY GREATER THAN 2,000 CFM, THE
 RETURN AIR & SUPPLY SYSTEM SHALL BE
 PROVIDED WITH SMOKE DETECTORS IN
 ACCORDANCE WITH SECTION 602.1 OR UPON
 ACTIVATION, THE SMOKE DETECTORS SHALL
 SHUT DOWN THE AIR DISTRIBUTION SYSTEM
 2001 FBC(M) 606.2.2 & 606.4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-13 Cont ID  
Sent By jleech Date 2002-08-13 Time 18:37 Rev Time 0.33
Received By jleech Date 2002-08-13 Time 18:37 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-08-22 Cont ID  
Sent By lhatten Date 2002-08-22 Time 18:55 Rev Time 2.50
Received By lhatten Date 2002-08-19 Time 18:54 Sent To  
Notes
2002-08-22 00:00:00REVIEW & STAMPED PLANS 08/19/2002
 CALC. FEES & PRINT CARD 08/22/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-08 Cont ID  
Sent By sgraham Date 2002-08-08 Time 14:10 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***