Plan Review Details - Permit 02080087
Plan Review Stops For Permit 02080087
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-09-18 Cont ID  
Sent By jwitmer Date 2002-09-18 Time 12:52 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-08-16 Cont ID  
Sent By pkrauss Date 2002-09-13 Time 10:09 Rev Time 3.00
Received By jwitmer Date 2002-08-16 Time 10:38 Sent To  
Notes
2002-08-16 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02080087
 ADD: 720 PALM STREET
 CONT:O/B PLAYER, JOHN
 TEL: (561)833-4811
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) 104.1.1 WHEN REQUIRED, PERMIT.
 PERMITS ARE REQUIRED WHEN EVER THERE IS
 A CHANGE OF USE. CITY RECORDS INDICATE
 THE REAR UNIT BEING A GARAGE/ STORAGE
 USEAGE. TO CHANGE THE OF USE TO A GARAGE
 APT. SHALL REQUIRE PLANS TO BE REVIEWED
 BY THE COUNTY BUILDING DEPARTMENT FOR
 IMPACT ASSESSMENT. TO BE COMPLETED BY
 THE O/B.
 THE COUNTY PROPERTY APPRAISERS OFFICE
 INDICATES THERE IS NO REAR BUILDING,
 WHENEVER THERE IS A CHANGE OF USE
 GARAGE TO APT. THERE WILL SHOW SQ.FT.
 NUMBER OF ROOMS,ETC. THIS ALSO MEANS
 THERE IS NO TAXES BEING COLLECTED ON THE
 REAR UNIT.
 IT IS UP TO THE OWNER TO PROVE THAT
 THEIR WAS A PERMIT PULLED TO CHANGE THE
 OCCUPANCY FROM GARAGE/ STORAGE TO A
 APARTMENT.
 THE OWNER MAY CONTACT APRIL PICCIRILLO
 AT 659-8096 X 8292 RECORD RESEARCH FOR
 AN APPOINTMENT, THE OWNERS ACTUALLY SET
 WITH THE JOURNALS TO REVIEW IF A PERMIT
 WAS PULLED TO CHANGE OCC. FROM STORAGE
 TO RESIDENTIAL.
  
 2) CHANGE OF OCCUPANCY. 3401.2.2
 IF THE OCCUPANCY CLASSIFICATION OR OCCU-
 PANCY SUBCLASSIFICATIONS OF ANY EXISTING
 BUILDING OR STRUCTURE IS CHANGED, THE
 BUILDING, ELECTRICAL, PLUMBING, GAS &
 MECHANICAL SYSTEMS SHALL BE MADE TO
 CONFORM TO THE INTENT OF THE TECHNICAL
 CODES AS REQUIRED BY THE BUILDING
 OFFICIAL.
  
 3) THE PERMIT APPLICATION INDICATES A
 VALUE OF $5,000.00 FOR THE COMPLETE
 PROJECT. THIS VALUE IS TO REFLECT THE
 MARKET VALUE. CITY CODE DOES ALLOW FOR
 IHE CITY TO DO A CALCULATED VALUE IF THE
 APPLICATION VALUE IS TO LOW.
 ORDANCE 3555-00.CHAP 7 SEC 7.2 FEE
 SCHEDULE. OWNER / BUILDER TO UP THE
 VALUE OF PERMIT TO MARKET VALUE.
  
 4)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
  
 5)1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 TABLE 600 FOOTNOTE I BUILDINGS LOCATED
 LESS THAN 5'-0" FROM THE PROPERTY LINE.
 709.6.2.2 THE FIRE RESISTANCE RATING OF
 A WOOD FRAMED ASSEMBLY IS EQUAL TO THE
 SUM OF THE TIME ASSIGNED TO THE MEMBRANE
 ON THE FIRE EXPOSED SIDE, THE TIME
 ASSIGNED TO THE FRAMING MEMBERS AND THE
 TIME ASIGNED FOR ADDITIONAL CONTRIBUTION
 BY OTHER PROTECTIVE MEASURES SUCH AS
 INSULATION. THE MEMBRANE ON THE
 UNEXPOSED SIDE SHALL NOT BE INCLUDED IN
 DETERMINING THE FIRE RESISTANCE OF THE
 ASSEMBLY.
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-09-10 Cont ID  
Sent By btrobaug Date 2002-09-10 Time 13:53 Rev Time 0.50
Received By btrobaug Date 2002-09-10 Time 12:44 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-08-12 Cont ID  
Sent By pkrauss Date 2002-08-08 Time 12:52 Rev Time 0.00
Received By btrobaug Date 2002-08-12 Time 09:15 Sent To B
Notes
2002-08-12 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRETIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2} PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 3} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12
  
 4} PLEASE SHOW THE PANEL LOCATION ON THE
 PLANS.
  
 5} PLEASE NOTE TWO APPLIANCE CIRCUITS
 REQUIRED FOR CALCS AND ON PANEL
 SCHEDULE PER 210-11(C)(1).
  
 6} PLEASE CHECK THE RANGE CALCULATION
 FOR COMPLIANCE WITH TABLE 220-19,ALSO
 NOTE THE OCP SEEMS INCORRECT FOR THE
 LOAD SERVED.
  
 7} THE GROUNDING ELECTRODE SYSTEM IS NOT
 COMPLETE PER 250-50 (ENTIRE ARTICLE).
  
 8} PLEASE INDICATE THE CONDUIT AND WIRE
 TYPE AND SIZE ON THE SERVICE RISER.
  
 9} THE GARAGE RECEPTACLES MUST COMPLY
 WITH 210-8(A)(2),PLEASE INDICATE SAME
 ON PLANS.
  
 10} PLEASE NOTE FRONT AND REAR
 RECEPTS REQ'D PER 210-52E.
  
 11} NOTE RECEPTACLE SPACING IN THE
 BEDROOM MUST COMPLY WITH 210-52(A)(1).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL:
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/659-8096 EXT. 8093

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-03 Cont ID  
Sent By csiegber Date 2003-12-03 Time 11:17 Rev Time 0.00
Received By csiegber Date 2003-12-03 Time 11:17 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-12-09 Cont ID  
Sent By pkrauss Date 2003-12-09 Time 15:18 Rev Time 0.25
Received By pkrauss Date 2003-12-09 Time 15:18 Sent To  
Notes
2003-12-09 00:00:00PROVISO:
 PLEASE SEE BELOW FOR PROPER SIZING OF
 RETURN AIR JUMPER IN ACCORDANCE WITH
 REVISION TO 2001 FBC(M) 601.4 EFFECTIVE
 JUNE 30, 2003.
  
 AUXILIARY DRAIN PAN REQUIRED PER 2001
 FBC(M) 307.2.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2002-09-13 Cont ID  
Sent By csiegber Date 2003-12-03 Time 11:21 Rev Time 0.35
Received By pkrauss Date 2002-09-13 Time 10:03 Sent To B
Notes
2002-09-13 00:00:00MECHANICAL PERMIT 02080182
  
 ENERGY CALCS & EQUIPMENT SUBMITTED -
 NO PLANS SUBMITTED FOR REVIEW.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-08-08 Cont ID  
Sent By btrobaug Date 2002-09-10 Time 13:53 Rev Time 0.35
Received By pkrauss Date 2002-08-08 Time 12:46 Sent To E
Notes
2002-08-08 00:00:00DENIED:MECHANICAL PERMIT 02080182
  
 PLEASE PROVIDE EQUIPMENT INFORMATION
 FOR THE AHU & CONDENSER (MAKE, MODEL,
 BTU'S, KW HEAT STRIP & SEER OF THE
 CONDENSER).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-08 Cont ID  
Sent By kstevens Date 2002-08-08 Time 08:53 Rev Time 0.00
Received By kstevens Date 2002-08-08 Time 08:53 Sent To M
Notes
***NONE***