Plan Review Details - Permit 02071745
Plan Review Stops For Permit 02071745
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-08-08 Cont ID  
Sent By pkrauss Date 2002-07-31 Time 11:37 Rev Time 1.00
Received By btrobaug Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-10-10 Cont ID  
Sent By btrobaug Date 2002-10-10 Time 13:31 Rev Time 0.50
Received By btrobaug Date 2002-10-10 Time 13:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-09 Cont ID  
Sent By btrobaug Date 2002-08-09 Time 13:40 Rev Time 0.00
Received By btrobaug Date 2002-08-09 Time 13:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-07-30 Cont ID  
Sent By btrobaug Date 2002-07-30 Time 14:45 Rev Time 0.00
Received By btrobaug Date 2002-07-30 Time 13:16 Sent To M
Notes
2002-07-30 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION, MAKE ANY NECESSARY CHANGES
 IN THE PLANS AND RESUBMIT FOR REVIEW:
  
 1} THERE IS A MAIN DISCONNECT SHOWN ON
 THE RISER DIAGRAM, BUT NOT LOCATED ON
 THE DRAWING.PLEASE INDICATE LOCATION.
  
 2} THE LOCATION OF THE PANEL IN THE
 KITCHEN IN RELATIONSHIP TO THE
 AHU/EWH,IS IN VIOLATION OF 110-26,AND
 MUST BE CORRECTED TO COMPLY.
  
 3} THE LOCATION OF THE A/C CONDENSER
 DISCONNECT AS DRAWN IS IN VIOLATION OF
 110-26.
  
 4} PLEASE NOTE THE REQ`D BATH(S)
 CIRCUIT(S), PER 210-11-C-3,
 MUST BE 20A AND #12AWG.
  
 5} PLEASE LIST THE REQ`D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12
  
 6} PLEASE NOTE IF LOW VOLTAGE IS TO BE
 INSTALLED WITH THIS PERMIT, IT MUST BE
 SHOWN ON THE PLANS.
  
 7} PLEASE SHOW HOW THE VALUATION FOR
 PERMIT LISTED VALUE WAS ARRIVED PER
 104.6.5(ATTACHED).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-07-31 Cont ID  
Sent By btrobaug Date 2002-07-30 Time 14:45 Rev Time 0.40
Received By pkrauss Date 2002-07-31 Time 10:34 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-07-27 Cont ID  
Sent By jleech Date 2002-07-27 Time 13:18 Rev Time 0.50
Received By jleech Date 2002-07-27 Time 13:18 Sent To  
Notes
2002-07-27 00:00:00FIXTURE REPLACEMENT AND MINOR PIPE
 REPAIR ONLY.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-08 Cont ID  
Sent By lmartine Date 2002-08-08 Time 16:41 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2002-08-08 00:00:00APPROVAL STAMP ON PLANS SIGNED BY
 SHIRLEY ON 8/16/02


Account Summary | Usage Policy | Privacy Policy