Plan Review Details - Permit 02071745
| Plan Review Stops For Permit 02071745 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-08-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-07-31 |
Time |
11:37 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-10-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-10 |
Time |
13:31 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2002-10-10 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-08-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-08-09 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-08-09 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-07-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-30 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-07-30 |
Time |
13:16 |
Sent To |
M |
|
| Notes |
| 2002-07-30 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION, MAKE ANY NECESSARY CHANGES | | | IN THE PLANS AND RESUBMIT FOR REVIEW: | | | | | | 1} THERE IS A MAIN DISCONNECT SHOWN ON | | | THE RISER DIAGRAM, BUT NOT LOCATED ON | | | THE DRAWING.PLEASE INDICATE LOCATION. | | | | | | 2} THE LOCATION OF THE PANEL IN THE | | | KITCHEN IN RELATIONSHIP TO THE | | | AHU/EWH,IS IN VIOLATION OF 110-26,AND | | | MUST BE CORRECTED TO COMPLY. | | | | | | 3} THE LOCATION OF THE A/C CONDENSER | | | DISCONNECT AS DRAWN IS IN VIOLATION OF | | | 110-26. | | | | | | 4} PLEASE NOTE THE REQ`D BATH(S) | | | CIRCUIT(S), PER 210-11-C-3, | | | MUST BE 20A AND #12AWG. | | | | | | 5} PLEASE LIST THE REQ`D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210-12 | | | | | | 6} PLEASE NOTE IF LOW VOLTAGE IS TO BE | | | INSTALLED WITH THIS PERMIT, IT MUST BE | | | SHOWN ON THE PLANS. | | | | | | 7} PLEASE SHOW HOW THE VALUATION FOR | | | PERMIT LISTED VALUE WAS ARRIVED PER | | | 104.6.5(ATTACHED). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-07-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-30 |
Time |
14:45 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-07-31 |
Time |
10:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-07-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-07-27 |
Time |
13:18 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2002-07-27 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2002-07-27 00:00:00 | FIXTURE REPLACEMENT AND MINOR PIPE | | | REPAIR ONLY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-08-08 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2002-08-08 |
Time |
16:41 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-08-08 00:00:00 | APPROVAL STAMP ON PLANS SIGNED BY | | | SHIRLEY ON 8/16/02 |
|
|
|