|
 |
 |
 |
 |
 |
Plan Review Details - Permit 02071111
| Plan Review Stops For Permit 02071111 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-30 |
Time |
13:11 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-12-30 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-07-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-31 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-07-31 |
Time |
08:31 |
Sent To |
R |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-10-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-31 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-10-31 |
Time |
09:51 |
Sent To |
P |
|
| Notes |
| 2002-10-31 00:00:00 | TO P IN BOX./WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-07-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-07-29 |
Time |
19:09 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-07-29 |
Time |
19:09 |
Sent To |
|
|
| Notes |
| 2002-07-29 00:00:00 | PASS/PRIVISO | | | 1) NEED LETTER FROM MANUFACTURE STATING | | | AIRHANDLER WILL NOT PRODUCE 2000 CFM. | | | IN ANY CONDITION.FOR FINAL | | | 2) NEED FRESH AIR CALCULATIONS FOR | | | ROUGH INSPECTION | | | 3) NEED PROGRAMMABLE THERMOSTAT FOR | | | FINAL | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT 8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-11-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-12 |
Time |
10:21 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-11-12 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2002-11-12 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-07-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-31 |
Time |
09:51 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-07-23 |
Time |
20:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2002-08-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-31 |
Time |
10:22 |
Rev Time |
3.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-08-15 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 02071111 | | | ADD: 2645 SANDY CAY | | | CONT: TAZ CONSTRUCTION | | | TEL: (954)340-1744 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ******PROVISO***** | | | | | | PROVIDE MISSING PRODUCT REPORTS BEFORE | | | FRAMING INSPECTION: | | | A) SWING DOORS | | | B) GLASS BLOCK | | | C) ROOFING ASSEMBLIES | | | CONNECTION DETAIL 15 OF SHEET A5, ON A | | | SINGLE MEMBER TRUSS THE VALUES GIVEN | | | FOR THE TA-14R OF 1520 @ EACH STRAP | | | EQUAL 3040 , A DERATING OF 20% IS RECOME | | | NDED BY USP OR A VALUE OF 2432 PLUS 785 | | | FOR THE MSH218 OR A TOTAL ALLOWABLE LOAD | | | OF 3217, THIS IS LIGHT VS THE 3833 | | | MAXIMUM UPLIFT. | | | | | | THE USE OF A 2 MEMBER MSH418 FACE MOUNT | | | WITH (2) TA-14R WITH REDUCTION ADEQUATE- | | | LY MEETS THE REQUIRED RESISTANCE FOR | | | UPLIFT. | | | BUILDING PLAN REVIEW | | | JIM WITMER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-07-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-07-19 |
Time |
14:59 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |