| Plan Review Stops For Permit 02070539 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-04-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-04-05 |
Time |
13:07 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-04-05 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2004-04-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)SEE PREVIOUS LIST, IMPACT | | | PROTECTION REQUIRED.THE PRODUCT | | | APPROVALS SUBMITTED INDICATE THAT THE | | | DOORS DO NOT HAVE IMPACT RATING. | | | | | | 2.)EXTERIOR STAIRS SHALL BE SEPARATED | | | FROM THE INTERIOR BUILDING BY WALLS WITH | | | A FIRE RESISTANCE RATING OF NOT LESS | | | THAN 1 HR, WITH FIXED OR SELF-CLOSING | | | OPENING PROTECTIVES.SHOW COMPLIANCE | | | FOR THE NEW FRENCH DOORS.FBC1006.2.4 | | | | | | 3.)THE ELEVATIONS SHOW SIDELITES, NOT | | | INCLUDED IN THE DOOR PRODUCT APPROVAL. | | | ALSO NEED MULLION PRODUCT APPROVALS. | | | | | | 4.)THE PRODUCT APPROVAL FOR THE | | | COMPONENT APPROVAL - SERIES 1518 | | | DOOR IS INCOMPLETE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-26 |
Time |
16:16 |
Rev Time |
1.50 |
| Received By |
shill |
Date |
2003-12-23 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | REVISION - CHANGE GARAGE DOORS TO | | | FRENCH DOORS | | | | | | 1.)THE PLANS ARE TO BE SEALED BY THE | | | DESIGNER OF RECORD, GORDON BUCK. | | | INCLUDE A COMPLETE TITLE BLOCK. | | | | | | 2.)SUBMIT PRODUCT APPROVALS FOR THE | | | FRENCH DOORS.IMPACT PROTECTION | | | REQUIRED FBC1606.1.4. | | | | | | 3.)CLOUD ALL CHANGES TO EXPEDITE | | | PLAN REVIEW. | | | | | | 4.)THE INFORMATION ON THE "NEW | | | RIGHT ELEVATION" (APPROVED SET) IS NOW | | | MISSING FROM THE "NEW EAST ELEVATION" | | | (REVISION SET).THE INFORMATION | | | DELETED IS IN REGARDS TO FIRE RATED | | | WINDOWS AND EGRESS.ADDRESS. | | | | | | 5.)METAM24 IS NOT IN THE SIMPSON 2003 | | | CATALOG.META24 IS AN EMBEDDED TRUSS | | | ANCHOR WITH A MAX UPLIFT OF 1500. THAT | | | APPLICATION CONFLICTS WITH YOURS, | | | DESIGN UPLIFT EXCEEDS PRODUCT | | | LIMITATIONS.ADDRESS.CHECK ALL | | | CONNECTORS. | | | | | | 6.)PLEASE NOTE THAT THIS CHANGE | | | HAS FAILED ZONING.A BUILDING REVISION | | | CANNOT BE ISSUED WITHOUT ZONING | | | APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-17 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-07-21 00:00:00 | BALCONY REVISION DATED 7/16/03 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-09 |
Time |
17:25 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-09 |
Time |
17:25 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-03-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-07 |
Time |
14:25 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-03-20 |
Time |
11:53 |
Sent To |
P |
|
| Notes |
| 2003-03-20 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE SHOW THE LOCATION OF THE SERVICE | | | ON THE DRAWING.HOW IS THE PANEL FOR THE | | | REAR BUILDING BEING FED? | | | NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | | PER NFPA-72 2-2.1.1.1. | | | IN THE VICINITY OF BEDROOMS AND CLOSE | | | PROXIMITY OF STIRWAYS. 2-5.2.1.3 | | | 3'FT FROM BATHS/KITCHENS.2-5.2.1.6 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-19 |
Time |
13:39 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2002-11-05 |
Time |
17:18 |
Sent To |
R |
|
| Notes |
| 2002-11-13 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION AND RESUBMIT FOR REVIEW. | | | | | | 1} THE RISER DIAGRAM ONLY SHOWS ONE | | | METER AND PANEL AT THE GARAGE.IS THERE | | | A SEPERATE SERVICE AT THE HOUSE? PLEASE | | | INDICATE COMPLIANCE WITH 250-32(A) & | | | (D) ON THE RISER DIAGRAM. | | | | | | 2} PLEASE SHOW LOAD CALCULATIONS AND | | | PANEL SCHEDULES FOR ALL PANELS PER | | | 215-5 & 220-3(C)(1). | | | | | | 3} THE AHU IN THE CABANA MUST COMPLY | | | WITH 210-63 IF APPLICABLE. | | | | | | 4} PLEASE CLARIFY THE PANEL SCHEDULE | | | NOTES,SEE HI-LIGHTED PORTION. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-03-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-26 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-26 |
Time |
16:16 |
Sent To |
B |
|
| Notes |
| 2004-03-26 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-17 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-17 |
Time |
14:13 |
Sent To |
B |
|
| Notes |
| 2003-12-17 00:00:00 | TO HP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-24 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-24 |
Time |
16:15 |
Sent To |
B |
|
| Notes |
| 2003-11-24 00:00:00 | TO HP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-07-18 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-18 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-18 |
Time |
14:47 |
Sent To |
B |
|
| Notes |
| 2003-07-18 00:00:00 | HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-07 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-07 |
Time |
14:25 |
Sent To |
E |
|
| Notes |
| 2003-05-07 00:00:00 | BT DESK, REVISION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-03-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-16 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-19 |
Time |
13:38 |
Sent To |
E |
|
| Notes |
| 2003-03-19 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-10-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-28 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-07-09 |
Time |
18:47 |
Sent To |
P |
|
| Notes |
| 2002-10-28 00:00:00 | TO PLUMBING IN BOX./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-05-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-20 |
Time |
13:14 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-05-20 |
Time |
13:14 |
Sent To |
B |
|
| Notes |
| 2003-05-20 00:00:00 | PROVISO: | | | | | | NO MECHANICAL WORK TO BE DONE IN MAIN | | | HOUSE.MINI-SPLITS IN GARAGE APT. SEE | | | MANUFACTURER INSTALLATION INSTRUCTIONS | | | INSTALLATION REQUIREMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-19 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2003-05-05 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | CUST SVC IN LOBBY NO MECH WORK TO BE | | | DONE IN THE MAIN HOUSE-ADDING DOOR ONLY |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-03-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-27 |
Time |
14:29 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-03-27 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2003-03-27 00:00:00 | PLEASE CORRELATE PLANS! 2ND REQUEST | | | APPROVAL FOR GARAGE APT ONLY - | | | ENERGY & MANUAL J CALCS SUBMITTED FOR | | | THE GARAGE APT ONLY.NO MECHANICAL | | | PLAN SUBMITTED. | | | | | | NO MECHANICAL WORK SUBMITTED FOR THE | | | MAIN HOUSE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-24 |
Time |
10:37 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-11-01 |
Time |
09:37 |
Sent To |
E |
|
| Notes |
| 2002-11-01 00:00:00 | DENIED: MECHANICAL PERMIT 02070540 | | | | | | PLANS SUBMITTED FOR 2ND REVIEW DO NOT | | | INCLUDE PLANS FOR HVAC.(HVAC PLANS ARE | | | STILL WITH OLD PLANS)PLEASE CORRELATE. | | | | | | PROVIDE INFORMATION FOR THE VENTING OF | | | THE GAS STOVE/OVEN. PROVIDE MANUFACTURER | | | SUBMITTAL DATA. | | | | | | CLARIFY THAT THE ONLY HVAC TO BE DONE IS | | | AT THE GARAGE APARTMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-19 |
Time |
08:24 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-05-19 |
Time |
08:18 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-09 |
Time |
17:26 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-03-24 |
Time |
10:15 |
Sent To |
M |
|
| Notes |
| 2003-03-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING. | | | | | | 1) MORE INFORMATION REQUIRED. DO THE | | | PLANS SUBMITTED PRIOR TO PLANS SUBMITTED | | | 3-19-03 HAVE ANYTHING TO DO WITH THE JOB | | | THAT WILL BE DONE?IF SO THEN ALL | | | SHEETS WILL HAVE TO BE PUT TOGETHER AS | | | A SET AND TWO COPIES WILL HAVE TO BE | | | SUBMITTED. IF NOT THEN ALL PLANS THAT | | | HAVE NOTHING TO DO WITH THE JOB SHALL | | | NOT BE RESUBMITTED. | | | 2) MANUF INFO REQUIRED FOR INSTA-HOT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-21 |
Time |
11:08 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2002-10-30 |
Time |
18:52 |
Sent To |
M |
|
| Notes |
| 2002-10-31 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | | | | 1) SHT D-1.0 DEMO NOTES #4, ALL CAPPED | | | PLUMBING PIPES SHALL BE INSPECTED PRIOR | | | TO COVERING. | | | 2) SHT A-1.1 GARAGE FLOOR PLAN, MANUF. | | | INFO REQUIRED FOR TANKLESS WATER HEATER. | | | 3) SHT A-1.1 GARAGE FLOOR PLAN, PLEASE | | | SUBMIT MANUF. INFO FOR GAS WATER HEATER. | | | SHOW DETAIL FOR VENTING. IS THIS A DIR- | | | ECT VENT SYSTEM? | | | 4) SHT E-1 PLUMBING NOTES #8, AIR CHAMB- | | | ERS ARE NOT APPROVED. PLEASE DELETE REF- | | | ERENCE. WATER HAMMER ARRESTORS TO BE IN- | | | STALLED PER 604.9. W/M - DISHWASHER - | | | ICE MAKER. | | | 5) SHT E-1 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE. PLEASE SUBMIT A RISER DIA | | | GRAM THAT MEETS CODE REQUIREMENTS. (SEE | | | ATTACHED SHEET FOR EXAMPLE) | | | 6) ENCLOSED USABLE SPACE SHALL BE PER- | | | MITTED UNDER STAIRS PROVIDED THE SPACE | | | IS SEPARATED FROM THE STAIR ENCLOSURE BY | | | THE SAME FIRE RESISTANCE AS THE EXIT EN- | | | CLOSURE. SEC 1006.1.4 EXCEPTION (1). | | | 7) GAS PERMIT REQUIRED. SEE FOLLOWING | | | GAS PERMIT APPLICATION REQUIREMENTS. | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | GAS CODE. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3) TYPE OF GAS, (LP OR NATURAL) | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | FBC-2001 FUEL GAS CODE SECS. 401.8 THRU | | | 402.5.2 & TABLES 402.2(1) THRU 402(34). | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR PER FBC-2001 FUEL GAS CODE SEC 304. | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 GAS CODE SEC. 402.2. IF | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAS CODE SEC | | | 502 THRU 506. | | | 10. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | 11. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-05-21 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-21 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2003-03-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-03-31 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-03-31 |
Time |
13:51 |
Sent To |
Z |
|
| Notes |
| 2003-03-31 00:00:00 | NEW PLANS DATED 3/18/03 PREPARED BY | | | CANALES DESIGNS. | | | | | | SHEET A1, THE AREA SHOWN AS "EXISTING | | | CONDITIONS W/REPAIRS"PLEASE CLEARLY | | | DEFINE THE SCOPE OF WORK. | | | | | | SHOW A CONNECTION DETAIL AND THE LENGTH | | | OF PROJECTION FOR THE NEW ROOF/CANOPY ON | | | THE NEW RIGHT ELEVATION. | | | | | | OPENINGS WITHIN TEN FEET OF THE STAIRS | | | ARE REQUIRED TO BE FIRE RATED.SEE FBC | | | 1006.2.4. | | | | | | NOTE THAT EMERGENCY EGRESS IS REQUIRED | | | FROM THE SLEEPING ROOM. FBC 1005.4. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-20 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-11-13 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2002-11-14 00:00:00 | THE NEW APARTMENT IS SUBJECT TO IMPACT | | | FEES COLLECTED BY THE COUNTY.THE | | | PERMIT PLANS MUST BE STAMPED BY THAT | | | OFFICE AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | CALL 561-233-5025 FOR MORE INFORMATION. | | | | | | SHOW THE FINISH FLOOR ELEVATION RELATIVE | | | TO NGVD. | | | | | | SHEET S2 SHOW THE DESIGN LOADS FOR THE | | | FLOORS, HAND AND GUARD RAILS AND | | | STAIRS. SEE FBC 1604 AND 1608. | | | | | | THERE ARE NO DIMENSIONS ON THE FRAMING | | | PLANS, S2. | | | | | | WITH REGARDS TO SECTION 1/S2, WHAT ARE | | | THE ASSUMED LOADS FOR THE TWO 1/2" | | | BOLTS THAT WILL SUPPORT THE FLOOR | | | GIRDER,PARTICULARLY THE F'B OF THE | | | WOOD? SEE FBC 104.2 | | | | | | SHOW THE REINFORCED MASONRY | | | SPECIFICATIONS IN ACCORDANCE WITH FBC | | | 2103.1 IE GROUT SPEC, POUR HEIGHT, | | | CLEAR SPACE, ETC. | | | | | | WILL THE MEZZANINE BE FRAMED ON A | | | LEDGERAS SHOWN IN SECTION 16/A4 OR | | | JOIST HANGERS AS SHOWN IN SECTION A/A3? | | | | | | THE PLANS DATED 9/26/02 DO NOT HAVE THE | | | MEZZANINE INFORMATION SHOWN ON THE | | | PLANS DATED 6/24/02.PLEASE COLLATE THE | | | PLANS INTO TWO CONCISE SETS. | | | | | | THE EXTERIOR STAIRS REQUIRE HANDRAILS AT | | | EACH SIDE.SEE FBC 1007.5.2. | | | | | | THE EXTERIOR STAIRS ARE NOT SERVED BY A | | | ROOFED 4 1/2 FEET WIDE BALCONY AS | | | REQUIRED BY FBC 1006.2.2. | | | | | | THE WINDOW OPENINGS IN THE AREA | | | PRESCRIBED IN FBC 1006.2.4 ARE REQUIRED | | | TO BE FIXED 3/4 HOUR RATED ASSEMBLIES. | | | (EXTERIOR STAIR) | | | | | | PLEASE PROVIDE THE CALCULATION REQUIRED | | | BY METRO DADE NOA 99-1012.04 FOR USE OF | | | THE MORTAR SET SYSTEM NOA 00-0218.03. | | | | | | PLEASE PROVIDE A RECENT, LEGIBLE, | | | SIGNED SEALED AND DATED SURVEY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
F |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-16 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-16 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2003-12-16 00:00:00 | DENIED NEED DEED RESTRICTION PER ANA | | | MARIA OF URBAN DESIGN CALLED KARL | | | PENEUDL MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-16 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2003-04-02 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-02 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
| 2003-04-02 00:00:00 | DENIED, OUTBUILDING MAY HAVE A MAXINUM | | | NET INTERIOR AREA OF 900 SQ FT AND | | | MAXINUM HABITABLE AREA OF 450 SQ FT. | | | THE 2ND FLOOR IS OVER THE LIMIT AT | | | 540 SQ FT. FIRST FLOOR MUST REMAIN AS | | | A GARAGE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2002-10-24 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-03-31 |
Time |
16:39 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-24 00:00:00 | PROVISO:NO GREATER THAN 14' FROM FIN. | | | FLOOR TO CEILING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2002-10-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-10-10 |
Time |
16:45 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-10 00:00:00 | DENIED,BLDG TOO TALL, OUT BLDGS (ART 4 | | | 33-42) SHALL BE ONLY 2-STORIES | | | 2ND CHECKLIST |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-07-11 |
Time |
11:49 |
Rev Time |
1.00 |
| Received By |
gjoyce |
Date |
2003-12-16 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2003-12-16 00:00:00 | MUST OBTAIN A DEED RESTRICTION PRIOR TO | | | PERMIT ISSUANCE. AG REGARDING THE CONVER | | | SION OR EXPANSION OF THE GARAGE APARTMEN | | | T | | 2002-07-11 00:00:00 | 1. ALL STORIES SHALL BE NO GREATER THAN | | | 14' FROM FINISHED FLOOR TO FINISHED | | | CEILING. THIS COUNTS FOR THE CEILING | | | THROUGHOUT, NOT JUST WHERE THE CEILING | | | MEET THE WALL. | | | 2. THE ALLOWABLE AREA FOR THE FOOT | | | PRINT OF THE STRUCTUE IS 450 SQ FT IN | | | REVIEW STAFF MEASURED 462 SQ FT. PLEASE | | | REDUCE THE SQUARE FOOTAGE TO MEET THE | | | ALLOWABLE. | | | 3. THE DAC BOARD HAS GIVEN THE STAFF | | | THE ADMINISTRATIVE ABILITY TO ALLOW | | | FOR A ROOF PITCH OF 3 OR 3.5 OVER | | | 12 FOR ROOFS IN THE PROVIDENCIA | | | NEIGHBORHOOD. STAFF SUGGESTS THAT THE | | | PITCH FOR THE ROOF COME DOWN TO | | | THE ALLOWABLE 3 TO 3.5 PITCH |
|
|