Plan Review Details - Permit 02070435
Plan Review Stops For Permit 02070435
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-21 Cont ID  
Sent By jwitmer Date 2002-10-21 Time 16:11 Rev Time 0.75
Received By jwitmer Date 2002-10-21 Time 16:11 Sent To  
Notes
2002-10-21 00:00:00REVISION:GOLF CART GARAGE

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-27 Cont ID  
Sent By jwitmer Date 2002-09-27 Time 10:00 Rev Time 2.00
Received By jwitmer Date 2002-09-27 Time 10:00 Sent To  
Notes
2002-09-27 00:00:00BUILDING PLAN REVIEW
 PERMIT:02070435
 ADD: 10510 TERRA LAGO DR
 CONT: CLASSIC / ZUCKERMAN
 TEL: (561)758-4608
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 REVISION: GOLF CART BUILDING
  
 1) THERE IS NO MEANS OF EGRESS INTO OR
 OUT OF THE BUILDING. 1012.1.2 EGRESS
 DOORS SHALL BE SIDE SWINGING, THERE IS
 NO SIDE SWINGING EGRESS DOORS!
  
 2)1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-06-24 Cont ID  
Sent By btrobaug Date 2003-06-24 Time 16:12 Rev Time 0.50
Received By btrobaug Date 2003-06-24 Time 16:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-24 Time 12:52 Rev Time 0.50
Received By btrobaug Date 2003-06-23 Time 10:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-10-18 Cont ID  
Sent By shernand Date 2003-06-19 Time 16:57 Rev Time 0.25
Received By dpalmer Date 2002-10-18 Time 14:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-09-25 Cont ID  
Sent By dpalmer Date 2002-09-25 Time 16:06 Rev Time 0.50
Received By dpalmer Date 2002-09-25 Time 16:06 Sent To  
Notes
2002-09-25 00:00:00************** UNSAT ************
  
 1)NOTE: PLEASE CLARIFY CIRCUITING AND/OR
 #`S OF CIRCUITS TO DETACHED BLDG.
 PLEASE NOTE MEANS OF DISC REQ`D PER
 225-31.
 PLEASE NOTE MEANS OF GROUNDING PER
 250-31.
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-30 Cont ID  
Sent By pkrauss Date 2002-07-26 Time 10:39 Rev Time 0.00
Received By dpalmer Date 2002-09-03 Time 14:33 Sent To R
Notes
2002-07-30 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THE FOLLOWING:
  
 1} THE "POWDER ROOM" ON SHEET A-11 IS
 MISSING A GFI PER 210-52(D).
  
 2} THERE ARE TWO PANELS SHOWN IN THE
 GARAGE ON SHEET A-11 AND ONLY ONE ON
 THE RISER DIAGRAM ON SHEET A-13.
  
 3} THE 4.8VA AHU HEAT STRIP LISTED ON
 THE PANEL SCHEDULE DOES NOT COMPLY WITH
 424-3(B)@ 125%.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL;
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-24 Cont ID  
Sent By shernand Date 2003-06-24 Time 12:51 Rev Time 0.00
Received By shernand Date 2003-06-24 Time 12:51 Sent To E
Notes
2003-06-24 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-19 Cont ID  
Sent By shernand Date 2003-06-19 Time 16:57 Rev Time 0.00
Received By shernand Date 2003-06-19 Time 16:57 Sent To E
Notes
2003-06-19 00:00:00DP DESK

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-07-26 Cont ID  
Sent By pkrauss Date 2002-07-26 Time 10:34 Rev Time 0.45
Received By pkrauss Date 2002-07-26 Time 10:18 Sent To E
Notes
2002-07-26 00:00:00PROVISO:MECHANICAL PERMIT 02070439
  
 SMOKE DETECTORS SHALL BE INSTALLED
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1OR
 UPON ACTIVATION, THE SMOKE DETECTORS
 SHALL SHUTDOWN THE AIR DISTRIBUTION
 SYSTEM. 2001 FBC(M) 606.4
  
 AHU IN GARAGE -
 APPLIANCES SHALL NOT BE INSTALLED IN A
 LOCATION WHERE SUBJECT TO MECHANICAL
 DAMAGE UNLESS PROTECTED BY APPROVED
 BARRIERS.2001 FBC(M) 303.4
  
 SHOULD A GAS DRYER BE INSTALLED -
 SHOW COMPLIANCE FOR COMBUSTION AIR AS
 PER 2001 FBC(M) CHAPTER 7.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-07-20 Cont ID  
Sent By jleech Date 2002-07-20 Time 09:46 Rev Time 0.33
Received By jleech Date 2002-07-20 Time 09:46 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-09-03 Cont ID  
Sent By dpalmer Date 2002-09-25 Time 16:05 Rev Time 2.00
Received By jwitmer Date 2002-09-03 Time 14:33 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-08-13 Cont ID  
Sent By btrobaug Date 2002-07-30 Time 07:24 Rev Time 4.00
Received By jwitmer Date 2002-08-13 Time 18:27 Sent To  
Notes
2002-08-13 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02070435
 ADD: 10510 TERRA LAGO DRIVE
 CONT: CLASSIC DESIGNER HOMES
 TEL: (954)345-2727
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) BUTT GLAZING: SITE SPECIFIC ENGINEER-
 ING, TO BE SITE SPECIFIC, ARCHITECT OR
 DESIGNER OF RECORD TO SEAL THE RIGHT
 SIDE OF FORM OR ATTACH A SEALED AFFIDA-
 VIT ATTESTING THIS PRODUCT SHALL MEET
 THE DESIGN CRITERIA OF THIS OPENING.
 THE SECOND ISSUE IS THE FORM INDI-
 CATES THE USE OF 1/4" GLASS WHEREAS THE
 ENGINEERING SHEET INDICATES 1/2"?
 GENERAL NOTES FOR BUTT GLAZING(6)
 SILICONE SEALENT PER WINDOW MANUFACT-
 URERS RECOMMENDATION. WHAT IS IT?
 SHEET A-4 REAR ELEVATION FOR THE BUTT
 GLASS INDICATES (12) 142"X90". SHEET A7,
 A13 INDICATES A "B-3" NO HEIGTH? PLEASE
 PROVIDE A CUT SECTION THROUGH OR ADDI-
 TIOAL INFORMATION.
  
 2) SHEET A-5 TABLE 600, WALL AREA IS
 FIGURED FROM FLOOR TO CEILING PER FLOOR,
 IN THIS CASE THE FLOOR TRUSSES ARE TO BE
 DEDUCTED OR 69 SQ FT REDUCING THE 20%
 ALLOWABLE AREA FROM 89.72 SQ FT TO
 75.92 SQ FT. THIS IS WITHOUT ADDING THE
 GLASS BLOCK OPENINGS, ALTHOUGH THE GLASS
 WILL NOT REQUIRE A 1 HR RATING, WE WILL
 NEED ADDITIONAL RATING (45MIN) TO NOT
 FIGURE IT AS PART OF THE ALLOWABLE
 WALL OPENINGS.
  
 3) SHEET A2/A7 INDICATES L-4, L-6 TO SIT
 ON THE SAME 8"X8" BLOCK COLUMN. 2101.3.1
 LINTEL, THE MINIMUM END BEARING SHALL
 BE 4", INDICATE HOW THIS WILL BE
 ACCOMPLISHED?
  
 4) SHEET A-7 / SEC 30/14 SEE 1511.6.3
 FLASHINGS: PROPER FLASHING SHALL BE IN-
 STALLED IN SUCH A MANNER AS TO PREVENT
 MOISTURE ENTERING THE WALL, INDICATE HOW
 WALL WILL BE FLASHED, SURFACE OF DECK
 AND HOW BLOCK WITH STEEL REBAR SHALL
 BE FLASHED?
  
 5) SHEET A-14 DETAIL 17 INDICATES A
 HOLD DOWN DEVICE SHA6T WITH A DESIGN
 LOAD OF 9,830 LBS.USP INDICATES AN
 ALLOWABLE UPLIFT OF 7550 LBS. NOTE 1
 NO ADDITIONAL ALLOWABLE LOADING MAY BE
 TAKEN!
  
 6) THIS SAME AREA, SHEET A-10 DETAIL
 1-A8 INDICATES A WALL SECTION TO THE
 RIGHT OF THE GIRDER WHERE DOES THIS GO?
  
 7) SHEET A-4 DETAIL 3, WALL MOUNT GUARD
 RAIL VS ELEVATIONS DO NOT MATCH, ELEVA-
 TION INDICATES 42" HEIGHT, DETAIL 48"
 1015.2 HEIGHT. GUARDRAILS SHALL
 FORM A VERTICAL PROTECTIVE BARRIER NOT
 LESS THAN 42" HIGH.
 1015.3 OPENINGS. OPEN GUARDRAILS
 SHALL HAVE INTERMEDIATE RAILS OR ORNA-
 MENTAL PATTERNS SUCH AS A 4" DIAMETER
 SPHERE CAN NOT PASS THROUGH. A BOTTOM
 RAIL OR CURB SHALL BE PROVIDED THAT WILL
 REJECT THE PASSAGE OF 2" DIAMETER
 SPHERE.
  
 SAME DETAIL CORRECT STATEMENT "SOUTHERN
 BUILDING CODE".
  
 8) 1007.3.1 TREADS / RISERS: (1)
 EVERY TREAD LESS THAN 10" SHALL HAVE A
 NOSING, OR EFFECTIVE PROJECTION OF AP-
 PROXIMATELY 1 INCH OVER THE LEVEL IMMED-
 IATELY BELOW THAT TREAD.
  
 9)2305.2.2 FLOOR/CEILING ASSEMBLIES
 SINGLE FAMILY DWELLINGS. IN FLOOR/CEIL/
 ING ASSEMBLIES SEPERATING USEABLE SPACE
 INTO 2 OR MORE APPROXIMATE AREAS WITH NO
 AREA GREATER THAN 500 SQ FT. DRAFTSTOP-
 PING SHALL BE PROVIDED PARALLEL TO THE
 MAIN FRAMING MEMBERS.
  
 10)1503.4 ROOF DRAINS UNLESS ROOFS ARE
 SLOPED TO DRAIN OVER THE ROOF EDGE, ROOF
 DRAINS SHALL BE INSTALLED AT THE LOWEST
 POINT OF THE ROOF. WHERE REQUIRED FOR
 ROOF DRAINAGE,SCUPPERS SHALL BE LOCATED
 AS DETERMINED BY THE ROOF SLOPE AND CON-
 TRIBUTING ROOF AREA.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-07-15 Cont ID  
Sent By sgraham Date 2002-07-15 Time 15:22 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***