Plan Review Details - Permit 02061757
| Plan Review Stops For Permit 02061757 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-09-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-09-10 |
Time |
10:26 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2002-09-10 |
Time |
10:12 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-08-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-08-02 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-08-02 |
Time |
06:25 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-07-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-24 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-07-24 |
Time |
11:33 |
Sent To |
FIRE |
|
| Notes |
| 2002-07-24 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION,MAKE ANY NECESSARY CHANGES | | | IN THE PLANS AND RESUBMIT FOR REVIEW: | | | | | | 1} INDICATE THE TYPE OF GROUNDING | | | ELECTRODE SYSTEM BEING USED AT THE | | | GENERATOR. | | | | | | 2} INDICATE THE GROUNDING ELECTRODE | | | CONDUCTOR SIZE AND METHOD OF GROUNDING | | | AT THE ATS. | | | | | | 3} DOES THE ATS HAVE A MECHANICAL MEANS | | | OF DISCONNECT? | | | | | | 4} WHERE IS THE GENERATOR DISCONNECTING | | | MEANS LOCATED? | | | | | | 5} PLEASE LIST THE CONDUIT AND WIRE | | | SIZE FROM THE EXISTING TANSFORMER TO | | | THE ATS. | | | | | | 6} PLEASE INDICATE THE CONDUIT AND WIRE | | | SIZE FROM THE ATS TO MDP-1. | | | | | | 7} INDICATE WHERE THE DISCONNECTING | | | MEANS IS FOR THE BUILDING SERVICE. | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT.8392 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-07-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-03 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-07-03 |
Time |
13:51 |
Sent To |
FIRE |
|
| Notes |
| 2002-07-03 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PROVIDE THE FOLLOWING INFORMATION,MAKE | | | NECESSARY CHANGES IN PLAN AND RESUBMIT | | | FOR REVIEW. | | | | | | 1} THE SCOPE OF THIS PROJECT REQUIRES AN | | | ENGINEERED SET OF DRAWINGS PER 471.025 | | | FS AND 553-79 FAC. | | | | | | 2} PLEASE PROVIDE A COPY OF THE | | | CONTRACTFOR THE PROPOSED PROJECT | | | INCLUDING THE COST OF LABOR AND | | | MATERIAL PER 104.6.5 CWPB AMMENDMENTS. | | | | | | 3} THE FPL SERVICE TO THE METER IS | | | LISTED AS BEING 120/208 VOLT-3 | | | PHASE.THE GENERATOR INDICATES A 480 | | | VOLT OUTPUT ,PLEASE CLARIFY. | | | | | | 4} FPL SERVICE IS LISTED AS 3 PHASE,4 | | | WIRE,BUT WITH 2 SETS OF 3EA 600 | | | MCM,WHICH WOULD INDICATE SINGLE | | | PHASE,OR THREE PHASE WITH NO NEUTRAL. | | | PLEASE CLARIFY. | | | | | | 5} PLEASE PROVIDE A LOAD CALCULATION AND | | | PANEL SCHEDULE FOR THE NEW PANEL. | | | | | | 6} INDICATE IF THE SERVICE SHOWN IS | | | EXISTING OR NEW. IF NEW PLEASE PROVIDE | | | AIC RATINGS PER 110-9 AND CALCULATIONS | | | PER 215-5. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561/659-8096 EXT.8392 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2002-08-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-09-10 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-08-09 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2002-07-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-08-02 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-07-30 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2002-07-30 00:00:00 | 1) PLEASE PROVIDE MORE DETAILS ON FUEL | | | TANK PLANNED FOR USE. THIS WOULD | | | INCLUDE ANY AND ALL PRODUCT APPROVALS | | | AND APPLICABLE LISTINGS FOR IT. | | | | | | 2) PLEASE PROVIDE MORE DETAILS ON | | | GENERATOR. AGAIN PRODUCT APPROVALS | | | OR SPECIFICATION BOOKS WOULD BE | | | HELPFUL. | | | | | | 3) IT WAS NOTED THAT THE FUEL TANK | | | WILL BE LOCATED NEAR THE LOADING DOCK. | | | IS THE FUEL TANK SUBJECT TO ANY | | | MECHANICAL DAMAGE. PLEASE ADVISE. | | | | | | 4) PLANS SHOULD INDICATE DIESEL OR | | | OTHER TYPE OF FUEL PLANNED FOR THE TANK. | | | | | | 5) PLEASE INDICATE ADJACENT PROPERTY | | | LINES WITH REGARDS TO GENERATOR AND | | | FUEL TANK INSTALLATION. | | | | | | 6) THE VENT LINE FOR THE FUEL TANK | | | SHALL BE A MINIMUM OF 12 FEET ABOVE THE | | | TANK. | | | | | | 7) VARIOUS DRAWINGS SHOULD BE CORRELATED | | | INTO ONE DOCUMENT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-07-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-24 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-07-12 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2002-07-12 00:00:00 | 1) PLEASE PROVIDE DETAILS ON GENERATOR | | | PLANNED FOR USE. | | | | | | 2) PLEASE PROVIDE DETAILS ON FOUR | | | HUNDRED GALLON FUEL TANK. | | | | | | 3) PLEASE INDICATE PROPERTY LINES | | | BY PROVIDING A LEGAL SURVEY. | | | | | | 4) PLEASE BE ADVISED THAT MERCER AVENUE | | | IS LOCATED IN THE CITY FIRE LIMITS. | | | CERTAIN RESTRICTIONS APPLY TO THE | | | INSTALLATION OF ABOVEGROUND FUEL AND | | | ABOVEGROUND PROPANE INSTALLATIONS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
|