Plan Review Details - Permit 02060877
Plan Review Stops For Permit 02060877
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-01-22 Cont ID  
Sent By jwitmer Date 2003-01-22 Time 07:29 Rev Time 2.50
Received By jwitmer Date 2003-01-22 Time 07:29 Sent To  
Notes
2003-01-22 00:00:00 
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02060877
 ADDRESS: 338 VALLEY FORGE RD
 CONT: JOHNSON & BARRETT INC
 TELL # (561)586-1144 (CELL)
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 *******PROVISO******
  
 1) COMMENT NUMBER 3 THE DEPICTED PORCH
 IS ALREADY EXISTING NO ADDITIONAL WIND
 LOAD IS BEING ADDED. NO ADDTIONAL STRAP-
 ING REQUIRED.
  
 COMMENT 6 ARCHITECT TO SUPPLY FASTENING
 DETAIL FOR 2" RIGID INSULATION & DECKING
 ARCHITECT TO GIVE DETAIL BEFORE ROOF
 SHEATHING INSPECTION.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-07-12 Cont ID  
Sent By pkrauss Date 2003-01-09 Time 09:23 Rev Time 3.00
Received By jwitmer Date 2002-07-12 Time 15:50 Sent To  
Notes
2002-07-12 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02060877
 ADD: 338 VALLEY FORGE RD
 CONT: JOHNSON & BARRETT CONST INC
 TEL: 329-7088
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 SHEET A-4 NOT SIHNED/ SEALED
  
 2) SHEET A-2 VARIOUS FOUNDATION DETAILS
 1804.1.3 THE BOTTOM OF THE FOUNDA-
 TION SHALL EXTEND NO LESS THAN 12"
 BELOW FINISH GRADE.NO DIMENSIONS GIVEN?
  
 3) SHEET A-2 DETAIL 8: DETAIL IMPLIES
 THAT THE ADDITIONAL 3X6 TO BE SCABBED
 TO THE EXISTING TRUSS, THERE IS NO INFOR
 MATION AS TO HOW TO RESTRICT THE ADDITIO
 NAL UPLIFT BEING IMPOSED ON THIS CONDI-
 TION
  
 4) SHEET A-2 DETAIL 7: INDICATES AN
 "ANCHOR BOLT" 6" X 5/8"?
  
 5) SHEET A-2 DETAIL 1: THE USE OF PECKY
 CYPRESS 1X6 T&G V JOINT DECKING, HOW
 ARE YOU GOING TO COMPLY WITH ROOFING
 NAILS ARE TO PENETRATE THE DECK 3/4INCH.
 WILL THIS BE A APPEARENCE PROBLEM?
  
 6) SHEET A-2 DETAIL 4 INDICATE WHAT TYPE
 FASTENR SHALL BE USED FOR THE 2" RIGID
 INSULATION + 3/4 "PLYWOOD DECKING?
  
 7) RAFTER SPACING NOT GIVEN FOR LIVING
 ROOM?
  
 8) 2309.1.7 COLLAR TIES OF 1X6 SHALL BE
 INSTALLED IN THE UPPER THIRD OF THE
 ROOF HEIGTH TO EVERY THIRD PAIR OF
 RAFTERS.
  
 9) THIS SET OF PLANS IS INCOMPLETE,
 THERE ARE 2 PAGES OF HAND DRAWN DETILS
 REFRENCING A "S-1" THAT IS NOT INCORP-
 ORATED INTO THIS SET OF PLANS, A
 THOROUGH REVIEW CAN NOT BE ACCOMPLISHED,
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-31 Cont ID  
Sent By btrobaug Date 2002-12-31 Time 15:53 Rev Time 0.75
Received By btrobaug Date 2002-12-31 Time 15:00 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-06-26 Cont ID  
Sent By pkrauss Date 2002-06-21 Time 13:30 Rev Time 0.00
Received By btrobaug Date 2002-06-26 Time 17:20 Sent To R
Notes
2002-06-26 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION AND RESUBMIT FOR REVIEW.
  
 1} PLEASE SUBMIT LOAD CALCAULATIONS PER
 220,215-5.
  
 2} INDICATE LOCATION OF SMOKE DETECTORS
 ON PLAN.
  
 3} IN THE AREAS WHERE NEW WIRING IS
 INSTALLED ALSO SHOW EXISTING AND
 INDICATE SAME.
  
 4} PLEASE NOTE THAT ALL PLANS
 DRAWN BY AN ARCHITECT/ENGINEER CONTAIN-
 ING A TITLE BLOCK, MUST BE SIGNED,
 DATEDAND SEALED BY THE ARCH/ENGINEER OF
 RECORD. PER FS/FAC 481.221 & 471.025
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-09-23 Cont ID  
Sent By pkrauss Date 2003-09-23 Time 10:29 Rev Time 0.33
Received By pkrauss Date 2003-09-23 Time 10:29 Sent To  
Notes
2003-09-23 00:00:00REVISION

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-01-09 Cont ID  
Sent By pkrauss Date 2003-01-09 Time 09:22 Rev Time 0.40
Received By pkrauss Date 2003-01-09 Time 08:37 Sent To B
Notes
2003-01-09 00:00:00MECHANICAL PERMIT 02060878

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-06-21 Cont ID  
Sent By kstevens Date 2003-01-07 Time 18:34 Rev Time 0.35
Received By pkrauss Date 2002-06-21 Time 11:42 Sent To E
Notes
2002-06-21 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW
  
 G.C. TO REMOVE MECHANICAL CONTRACTOR
 FROM APPLICATION.SUBCONTRACTOR TO
 PROVIDE PLANS WITH MECHANICAL PERMIT
 APPLICATION.AS PER CONSERVATION
 6-21-02 W/JOHNSON & BARRETT CONST.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-07 Cont ID  
Sent By kstevens Date 2003-01-07 Time 18:31 Rev Time 0.50
Received By kstevens Date 2003-01-07 Time 18:31 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-21 Cont ID  
Sent By btrobaug Date 2002-12-31 Time 15:54 Rev Time 0.00
Received By kstevens Date 2002-06-21 Time 06:55 Sent To  
Notes
2002-06-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) PLEASE SUBMIT EXISTING FLOOR PLAN
 FOR BATHROOM TO DETERMINE CHANGES MADE
 PLEASE SUBMIT SANITARY RISER DIAGRAM.
 SHOW TIE IN TO EXISTING, PIPE SIZE AND
 VENTING.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-18 Cont ID  
Sent By sgraham Date 2002-06-18 Time 07:50 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***