Plan Review Details - Permit 02060575
| Plan Review Stops For Permit 02060575 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-06-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-18 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-06-19 |
Time |
17:46 |
Sent To |
R |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-06-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-18 |
Time |
14:36 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-06-18 |
Time |
14:29 |
Sent To |
E |
|
| Notes |
| 2002-06-18 00:00:00 | PROVISO:MECHANICAL PERMIT 02060589 | | | | | | CONDENSATE SHALL DISCHARGE A MINIMUM OF | | | 12" AWAY FROM THE BUILDING STRUCTURE AS | | | PER 2001 FBC 1503.4.4. | | | | | | OVERFLOW PROTECTION REQUIRED AS PER | | | 2001 FBC(M) 307.2.3. | | | | | | 2001 FBC(M) 402.2 - NATURAL VENTILATION | | | FOR OUTSIDE AIR REQUIRMENT. SHOW | | | COMPLIANCE FOR THE MINIMUM OPENABLE AREA | | | TO THE OUTDOORS. (4 PERCENT OF THE FLOOR | | | AREA BEING VENTILATED) OR TABLE 403.3 | | | FOR MECHANICAL VENTILATION. | | | | | | SHOULD GAS DRYERS BE INSTALLED - | | | SHOW COMPLIANCE FOR COMBUSTION AIR AS | | | PER 2001 FBC(M) CHAPTER 7. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-08-05 |
Time |
19:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-08-05 |
Time |
19:47 |
Sent To |
|
|
| Notes |
| 2002-08-05 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-07-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-07-24 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-24 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2002-07-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHOWER IN CABANA BATH AND TUB IN BATH | | | #3 NOT VENTED. THE WET VENT SHALL BE | | | CONSIDERED THE VENT FOR THE FIXTURES AND | | | SHALL EXTEND FROM THE CONNECTION OF THE | | | DRY VENT ALONG THE DIRECTION OF THE FLOW | | | IN THE DRAIN PIPE TO THE MOST DOWNSTREAM | | | FIXTURE DRAIN CONNECTION TO THE HORIZ- | | | ONTAL BRANCH DRAIN. 909.1 SINCE THE DRY | | | VENT STARTS ABOVE THE LAVS AND THE LAVS | | | ARE THE MOST DOWNSTREAM FIXTURE DRAIN | | | CONNECTION, THE SHOWER/TUB ARE NOT VENT- | | | ED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-06-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-06-15 |
Time |
11:46 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-06-15 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2002-07-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-06-19 |
Time |
17:46 |
Rev Time |
2.50 |
| Received By |
lhatten |
Date |
2002-07-01 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2002-07-02 00:00:00 | REVIEW & STAMPED PLANS 07/01/2002 | | | CALC. FEES & PRINT CARDS 07/02/2002 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-06-18 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-06-18 |
Time |
07:50 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy