Plan Review Details - Permit 02060560
Plan Review Stops For Permit 02060560
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-03 Cont ID  
Sent By pkrauss Date 2002-06-17 Time 16:10 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-07-03 00:00:00OK PER DEWEY PALMER 6-19-02

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-12-11 Cont ID  
Sent By rregueir Date 2002-12-11 Time 17:05 Rev Time 0.50
Received By rregueir Date 2002-12-11 Time 17:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-08 Cont ID  
Sent By pkrauss Date 2002-08-08 Time 14:09 Rev Time 0.30
Received By pkrauss Date 2002-08-08 Time 13:46 Sent To  
Notes
2002-08-08 00:00:00MECHANICAL PERMIT 02060617

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-06-17 Cont ID  
Sent By pkrauss Date 2002-06-17 Time 16:06 Rev Time 0.40
Received By pkrauss Date 2002-06-17 Time 16:02 Sent To E
Notes
2002-06-17 00:00:00*******************DENIED***************
  
 MECHANICAL PERMIT 02060617
  
 AIR CONDITIONING SCHEDULE ON PLAN SHEET
 MP-2 DO NOT MATCH THE ENERGY CALCS OR
 CFM DISTRIBUTION AS INDICATED ON THE
 PLAN.PLEASE CORRECT AIR CONDITIONING
 SCHEDULE (2-AHU #1 ARE LISTED AT 1200
 CFM)
  
 PROVISO:
 CONDENSATE SHALL DISCHARGE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE AS
 PER 2001 FBC 1503.4.4.
  
 OVERFLOW PROTECTION REQUIRED AS PER
 2001 FBC(M) 307.2.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-15 Cont ID  
Sent By jleech Date 2002-06-15 Time 09:37 Rev Time 0.33
Received By jleech Date 2002-06-15 Time 09:37 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-09 Cont ID  
Sent By rmcdouga Date 2002-08-09 Time 13:20 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-09 00:00:00************BUILDING PROVISO************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) PROVIDE A SOIL BEARING TEST REPORT
 AS REQUIRED BY CITY OF WEST PALM BEACH
 AMENDMENTS TO THE 2001 FBC SEC.1804.2.2.
  
 3) THE PRODUCT APPROVALS SUBMITTED FOR
 THE DOUBLE FRONT DOORS ARE NOT LEGIBLE.
 PLEASE SUBMIT CLEAR LEGIBLE COPIES OF
 THE PRODUCT APPROVALS.
  
 4) THE COVER SHEET OF THE PRODUCT
 APPROVALS FOR THE SINGLE HUNG WINDOWS
 DOES NOT CORRESPOND WITH THE OTHER PAGES
 SUBMITTED. THE EVALUATION NUMBERS DO NOT
 MATCH AND ALL THE PAGES EXCEPT THE COVER
 PAGE ARE EXPIRED. PLEASE SUBMIT CURRENT
 AND COMPLETE PRODUCT APPROVALS FOR THE
 SINGLE HUNG WINDS.
  
 5) THE OPENING SIZES FOR THE WINDOWS AND
 DOORS LISTED ON THE INSTALLATION
 SCHEDULE DIFFER FROM THOSE GIVEN ON THE
 PLANS AND THE KEY PLAN. PLEASE SUBMIT A
 REVISED KEY PLAN AND INSTALLATION
 SCHEDULE WHICH MATCHES THE OPENING SIZES
 LISTED ON THE PLANS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-07-03 Cont ID  
Sent By rmcdouga Date 2002-07-03 Time 10:13 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-07-03 00:00:00BUILDING DENIED
  
 1)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) STRUCTURE IS LOCATED IN AN "A8" FLOOD
 ZONE AN ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 3) PROVIDE A SOIL BEARING REPORT PER
 CITY AMENDMENTS TO THE 2001 FBC 1804.2.2
  
 4) INDICATE THE APPLICABLE INTERNAL
 PRESSURE COEFFICIENT ON THE PLANS AS
 REQUIRED BY FBC 1606.1.7.
  
 5) THE SQUARE FOOTAGE GIVEN ON THE PLANS
 FOR THE GARAGE ON SHEET C-1 IS 557 SQFT.
 AND ON A-1 IS 427SQFT. PLEASE CLARIFY.
  
 6) THE BONUS ROOM IS REQUIRED TO BE
 PERMANETLY MARK ON THE PLANS THAT IT IS
 NOT TO BE USED FOR SLEEPING PURPOSES.
 OPENINGS FROM A GARAGE DIRECTLY INTO A
 ROOM USED FOR SLEEPING IS NOT PERMITTED
 PER FBC 411.2.8.
  
 7) THE WINDOW (H) IN THE FIRST FLOOR
 BATH ROOM IS REQUIRED TO HAVE TEMPERED
 GLASS, BECAUSE IT IS WITHIN 3 FEET
 HORIZONALLY OF THE TUB PER FBC 2405.2.1.
  
 8) PLEASE CHANGE NOTE 6 UNDER GENERAL
 NOTES ON SHEET A-2 TO REFERENCE THE
 2001 FLORIDA PLUMBING CODE.
  
 9) SECTION B ON A-6 INDICATES R-19
 INSULATION IN THE ATTIC AND THE ENERGY
 CALCULATIONS LISTS R-30. PLEASE CORRECT.
  
 10) THE NAILS AND SPACING LISTED FOR THE
 FLOOR ON SECTION 2 ON SHEET S-2 DOES NOT
 CORRESPOND WITH THE FLOOR DIAPHRAGM
 NAILING SPECIFIED IN THE SCHEDULE.
  
 11) THE CONDITIONED FLOOR AREA LISTED ON
 THE ENERGY CALCULATIONS DIFFERS FROM THE
 A/C AREA GIVEN ON THE PLANS. PLEASE
 CORRECT.
  
 12) INDICATE ON THE PLANS THAT THE BONUS
 ROOM WALLS ARE INSULATED.
  
 13) THE AREA UNDER ATTIC LISTED ON THE
 ENERGY CALCS. DOES NOT APPEAR TO INCLUDE
 THE BONUS ROOM. THE ADJACENT WOOD FRAME
 WALL AREA DOES NOT APPEAR TO BE CORRECT.
 PLEASE REVIEW AND CORRECT.
  
 14) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - FRONT DOOR (OUTSWING DOUBLE DOORS
 WITHOUT SIDELITES)
 - STRUCTURAL MULLIONS (THE ONES THAT
 WERE SUBMITTED EXPIRED ON 5-30-02)
  
 16) PROVIDE AN INSTALLATION SCHEDULE FOR
 THE STORM PANELS. INDICATE THE TYPE OF
 FASTENER AND MOUNTING OPTIONS THAT WILL
 BE USED (CIRCLE OR HIGHLIGHT ON THE
 PRODUCT APPROVAL DRAWINGS). THIS
 INFORMATION IS REQUIRED AT TIME OF
 PERMIT OR A SEPARATE PERMIT WILL BE
 REQUIRED WITH ADDITIONAL PERMIT FEES.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-14 Cont ID  
Sent By sgraham Date 2002-06-14 Time 07:35 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***