Plan Review Details - Permit 02060555
Plan Review Stops For Permit 02060555
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-08 Cont ID  
Sent By dpalmer Date 2002-08-08 Time 06:28 Rev Time 0.00
Received By dpalmer Date 2002-08-08 Time 06:28 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-19 Cont ID  
Sent By pkrauss Date 2002-06-18 Time 15:10 Rev Time 0.00
Received By btrobaug Date 2002-06-19 Time 15:27 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-11-26 Cont ID  
Sent By hmoser Date 2002-11-26 Time 19:11 Rev Time 0.50
Received By hmoser Date 2002-11-26 Time 19:11 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-09 Cont ID  
Sent By pkrauss Date 2002-08-09 Time 13:44 Rev Time 0.25
Received By pkrauss Date 2002-08-09 Time 13:39 Sent To  
Notes
2002-08-09 00:00:00RE-STAMP
 MECH 02060650

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-18 Cont ID  
Sent By pkrauss Date 2002-06-18 Time 15:08 Rev Time 0.35
Received By pkrauss Date 2002-06-18 Time 15:04 Sent To E
Notes
2002-06-18 00:00:00PROVISO:MECHANICAL PERMIT 02060650
  
 CONDENSATE SHALL DISCHARGE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE AS
 PER 2001 FBC 1503.4.4.
  
 2001 FBC(M) 402.2 - NATURAL VENTILATION
 FOR OUTSIDE AIR REQUIRMENT. SHOW
 COMPLIANCE FOR THE MINIMUM OPENABLE AREA
 TO THE OUTDOORS. (4 PERCENT OF THE FLOOR
 AREA BEING VENTILATED) OR TABLE 403.3
 FOR MECHANICAL VENTILATION.
  
 OVERFLOW PROTECTION REQUIRED AS PER
 2001 FBC(M) 307.2.3.
  
 SMOKE DETECTORS SHALL BE INSTALLED IN
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTORS
 WITH NOTIFICATION TO ALARM/STOBE OR AREA
 SMOKE DETECTORS. 2001 FBC(M) 606.4.1
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-15 Cont ID  
Sent By dpalmer Date 2002-08-08 Time 06:28 Rev Time 0.33
Received By jleech Date 2002-06-15 Time 13:20 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-10-30 Cont ID  
Sent By jgomez Date 2002-10-30 Time 10:31 Rev Time 2.00
Received By jgomez Date 2002-10-29 Time 18:41 Sent To  
Notes
2002-10-30 00:00:00SUBMITTAL CHECKLIST:
 1-PROVIDE SOIL TEST REPORT.
 2-STORM SHUTTERS: A)CLARIFY DESIGN PRE-
 SSURES. SEE ARCHITECTURAL DWGS. NOTE:
 DESIGN PRESSURES LIMITS THE MAX. SPAN
 OF PANELS. B)CLEARLY INDICATE ON DWGS
 ANCHOR TYPE AND SPACING TO BE USED IN
 THIS PROJECT. C)CLARIFY IF USING RAWL
 OR CAULK-IN ANCHORS. D)PROVIDE COMPLE-
 TE SBCCI PRODUCT APPROVAL REPORT.
 3-ARCHITECT TO CLARIFY DESIGN PRESSURES
 CALCULATED FOR ENTRY DOORS. SEE FLOOR
 PLAN AND EXTERIOR ELEVATION.
 4-PROVIDE COMPLETE INFORMATION FOR
 STRUCTURAL BUCK DETAIL AT GARAGE.
 MISSING ANCHOR BOLT SIZE AND WASHER.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 5-REVISED TRUSS ANCHOR SCHEDULE IS NOT
 CORRECT. SEE USP CATALOGUE FOR NAIL
 TYPE AND CORRESPONDING VALUES OR
 PROVIDE ENGINEERING CALCULATIONS FOR
 DIFFERENT VALUES.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 6-DETAIL 5/S3 IS NOT GOOD. CONNECTOR
 HL210 IS A PURLIN HANGER. IT DOESN'T
 RESIST THE CALCULATED LOADS AND IS NOT
 INTENDED TO SUPPORT BEAMS. SEE USP
 CATALOGUE AND 2ND FLOOR FRAMING PLAN.
 REVISE CONNECTION AS REQUIRED.
 7-SPECIFY ROOF TRUSS CONNECTOR @ GIRDER
 TRUSS WITH UPLIFT LOAD OF 2537#.
 8-REVISE CONNECTOR (2)TC-6 FOR THE OTHER
 ROOF GIRDER TRUSS. USE VALUES OF RE-
 REVISED TRUSS ANCHOR SCHEDULE. SEE USP
 CATALOGUE. SEC. 104.2.1.2 CITY AMENDM/

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-06 Cont ID  
Sent By jgomez Date 2002-08-06 Time 18:06 Rev Time 0.00
Received By jgomez Date 2002-08-06 Time 18:06 Sent To  
Notes
2002-08-06 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE SIGNED AND SEALED SOIL TEST
 REPORT.
 2-STORM SHUTTERS:
 A)DRAWINGS DON'T MATCH PRODUCT APPROVAL.
 B)DRAWINGS ARE NOT LEGIBLE.
 C)CHECK KEY PLAN AND INSTALLATION
 SCHEDULE WITH DRAWINGS SUBMITTED.
 3-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOORS PRODUCT APPROVAL AND DWGS
 ARE NOT LEGIBLE. (NOTE: CHECK THE
 EXPIRATION DATE FOR FUTURE SUBMITTALS.
 B)SINGLE HUNG FIRST PAGE OF PRODUCT
 APPROVAL DOESN'T MATCH THE REST OF THE
 REPORT AND DRAWINGS. RESUBMIT CORRECT
 COMPLETE REPORT AND DRAWINGS.
 4-SPECIFY FIREBLOCKING LOCATION,MATERIAL
 AND SIZE AT STAIRS, INCLUDING FIRE-
 BLOCKING AT TOP OF STAIRS. SEE SEC.
 2305.1.4 FBC 2001.
 5-REVISE KEY NOTE #37 ON SHEET A-1. FULL
 HEIGHT WALL AS SHOWN ON EXTERIOR ELEV.
 TO COMPLY WITH TABLE 600 FBC 2001.
 6-SECOND FLOOR FRAMING PLAN: SPECIFY
 DRAFSTOPPING AT AREAS NOT MORE THAN
 500 S.F. AS REQUIRED BY SECTION
 2305.2.2 FBC 2001.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-07-10 Cont ID  
Sent By btrobaug Date 2002-06-19 Time 15:42 Rev Time 0.00
Received By jgomez Date 2002-07-10 Time 13:55 Sent To  
Notes
2002-07-10 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-ENTRY DOORS DON'T PROVIDE THE 32" MIN.
 CLEAR OPENING REQUIRED BY TABLE 1004
 FBC 2001. REVISE AS REQUIRED.
 3-ENERGY CALCULATIONS:
 A)THERE IS NOT ADJACENT FRAME WALL. SEE
 PLANS AND REVISE AS REQUIRED.
 B)OWNER/AGENT TO DATE BOTTOM OF FORM TOO
 4-WINDOW BY ENTRY PORCH EXCEEDS THE MAX.
 PERCENTAGE OF OPENINGS ALLOWED BY
 TABLE 600 FBC 2001. REVISE AS REQUIRED
 5-SPECIFY FIREBLOCKING MATERIAL AND
 LOCATION AT STAIRS. SEC. 2305 FBC 2001
 **NOTE: FIREBLOCKING & DRAFSTOPPING ARE
 2 DIFFERENT THINGS.
 6-SPECIFY FIRECUT AT MASONRY WALL AS
 REQUIRED BY SEC. 2305.4 FBC 2001.
 7-2ND FL. FRAMING PLAN: SPECIFY MATERIAL
 & LOCATION OF DRAFSTOPPING AS REQUIRED
 BY SEC. 2305.2.2 FBC 2001.
 8-PROVIDE SOIL TEST REPORT.
 9-STORM SHUTTERS:
 A)PROVIDE COMPLETE INSTALLATION SCHEDULE
 AND KEY PLAN. SEE CITY COPY.
 B)CLEARLY INDICATE ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO
 (CONCRETE BLOCK OR CONCRETE).
 10-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOORS AS SHOWN ON PLANS.
 B)COMPLETE PANAMERICAN WINDOW MULLION
 PRODUCT APPROVAL.
 C)SINGLE HUNG WINDOW PRODUCT APPROVAL
 DOESN'T MATCH DRAWINGS.
  
 11-SHEET C-1 IS MISSING THE INTERNAL
 PRESSURE COEFFICIENT AS REQUIRED BY
 SEC. 1606.1.7 FBC 2001.
 12-APPROVED PRODUCT APPROVAL ARE STAMPED
 ALL OTHERS ARE RETURNED. SEE COMMENTS
 ON YELLOW STICKERS.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-18 Cont ID  
Sent By sgraham Date 2002-06-18 Time 07:49 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***