Plan Review Details - Permit 02060554
Plan Review Stops For Permit 02060554
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-16 Cont ID  
Sent By btrobaug Date 2002-08-16 Time 12:45 Rev Time 0.00
Received By btrobaug Date 2002-08-16 Time 12:38 Sent To R
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-19 Cont ID  
Sent By btrobaug Date 2002-06-19 Time 14:05 Rev Time 0.00
Received By btrobaug Date 2002-06-19 Time 13:48 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-12-07 Cont ID  
Sent By hmoser Date 2002-12-07 Time 08:20 Rev Time 0.50
Received By hmoser Date 2002-12-07 Time 08:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-15 Cont ID  
Sent By hmoser Date 2002-08-15 Time 18:08 Rev Time 0.50
Received By hmoser Date 2002-08-15 Time 18:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-18 Cont ID  
Sent By pkrauss Date 2002-06-18 Time 14:24 Rev Time  
Received By jleech Date   Time   Sent To  
Notes
2002-06-18 00:00:00PROVISO:MECHANICAL PERMIT 02060629
  
 OVERFLOW PROTECTION REQUIRED AS PER
 2001 FBC(M) 307.2.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-08-13 Cont ID  
Sent By jleech Date 2002-08-13 Time 17:00 Rev Time 25.00
Received By jleech Date 2002-08-13 Time 17:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-15 Cont ID  
Sent By jleech Date 2002-06-15 Time 10:38 Rev Time 0.33
Received By jleech Date 2002-06-15 Time 10:38 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-08-20 Cont ID  
Sent By jgomez Date 2002-08-20 Time 09:23 Rev Time 0.00
Received By jgomez Date 2002-08-20 Time 14:54 Sent To  
Notes
2002-08-20 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE ENGINEERING ANALYSIS/CALCS AND
 COMPLETE SECTIONS/DETAILS/SPECS FOR
 DESIGN CLARIFICATION OF GABLE END AT
 FRONT ELEVATION CONSIDERING THAT THE
 CENTER OF GABLE IS MASONRY AND THE TWO
 SIDES ARE WOOD TRUSSES. SEE SECTIONS
 1606.2.4, 2117 AND 2313 FBC 2001.
 2-PROVIDE SOIL TEST REPORT.
 3-PROVIDE COMPLETE & CORRECT INFORMATION
 FOR STORM PANELS UNDER SEPARATE PERMIT
 AS REQUIRED BY CITY HURRICANE STANDARD
 4-PROVIDE PRODUCT APPROVAL FOR DOORS,
 WINDOWS AND WINDOW MULLIONS ASEMBLIES
 AS SHOWN ON PLANS.
 5-PROVIDE UL LISTING AND SPECS FOR ONE
 HOUR FIRE RATED GLASS BLOCK ASSEMBLY
 AS REQUIRED BY TABLE 600 FBC 2001.
 REVISE GLASS BLOCK ASSEMBLY DETAILS AS
 REQUIRED. SEE UL ASSEMBLY SPECS.
 **NOTE: GLASS BLOCK TO BE SAFETY GLAZING
 IF MIN. UNIFORM THICKNESS IS LESS THAN
 0.25". SEC. 2405.2.2 FBC 2001.
 6-SHEET S1: CORRECT LINTEL SPECIFIED FOR
 GARAGE DOOR. THERE ISN'T L-19 ON SCHED
 **NOTE: CHECK THAT LINTEL SCHEDULE MATCH
 OPENINGS SHOWN ON PLANS. EG: CHECK L9
 **SPECIFY SPACING FOR WWM SUPPORTS. SEE
 SEC. 1909.3 FBC 2001.
 7-REVISE/CLARIFY TRUSS ANCHOR SCHEDULE:
 UPLIFT AND LATERAL LOADS TO MATCH USP
 SPECIFICATIONS. SEE USP CATALOGUE.
 PROVIDE ENGINEERED CALCS FOR LOADS
 DIFFERENT THAN THOSE SHOWN BY USP.
 **NOTE: SEE USP INSTALLATION NOTES (PAGE
 40) FOR LIMITATIONS WHEN USING DOUBLE
 ANCHORS (EG: LESS THAN 8" O.C).
 8-CLARIFY WHY BLOCKING & FRONT GABLE END
 IS SHOWN ONLY ON PARTIAL GABLE AND NOT
 ALL THE WAY AT BOTH ENDS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 9-DRAWING 9/A-4 SHOWING RECESS OF WINDOW
 TO INSTALL SHUTTERS IS NOT CLEAR.
 PROVIDE COMPLETE DETAIL SHOWING RECESS
 DIMENSIONS. SEE STORM SHUTTERS PRODUCT
 APPROVAL & DRAWINGS TO INDICATE TRACK
 SYSTEM TO BE USED AND EDGE DISTANCE
 AND GLASS SEPARATION REQUIRED.
 10-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR
 FIXED WINDOW. DETAIL SUBMITTED DOESN'T
 APPLY. NEED FOR MASONRY WALL, NOT FOR
 FRAMED WALL.
 11-DIAPHRAGM SCHEDULE: CLEARLY IDENTIFY
 ROOF NAILING ZONES ON FRAMING PLAN.
 12-SEE PRODUCT APPROVAL FOR GARAGE DOOR
 FOR STRUCTURAL BUCK SPECS AND REVISE
 DETAIL AS REQUIRED.
 13-CLARIFY SIZE OF ATTIC VENTS. SEE WALL
 SECTIONS NOTES AND VENT CALCULATIONS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-08-13 Cont ID  
Sent By btrobaug Date 2002-08-16 Time 12:45 Rev Time 0.00
Received By jgomez Date 2002-08-13 Time 12:10 Sent To  
Notes
2002-08-13 00:00:00CHECKLIST:
 1-PROVIDE COMPLETE DETAILS AND SPECS FOR
 GABLE END SECTION AT FRONT ELEVATION.
 CLARIFY HOW DOES THE HALF MASONRY,
 HALF WOOD FRAMING GABLE END WORKS.
 PROVIDE ENGINEER ANALYSIS SHOWING THE
 TRANSITION OF THE WIND LOADS TO THE
 SHEARWALLS & ROOF. SEE SEC. 1606.2.4.
 ALSO, SHOW HOW IS THE GABLE END STRUC-
 TURALLY CONTINUOUS AS REQUIRED BY SEC
 2117 AND 2313 FBC 2001.
 2-NEED RECORDED NOTICE OF COMMENCEMENT.
 3-PROVIDE SOIL TEST REPORT
 4-PROVIDE COMPLETE & CORRECT INFORMATION
 FOR STORM SHUTTERS OR APPLY FOR A
 SEPARATE PERMIT. NEED: A)LEGIBLE DWGS
 THAT MATCH PRODUCT APPROVAL. B)REVISE
 KEY PLAN & INSTALLATION SCHEDULE TO
 MATCH OPENINGS SIZE, ETC. C)VERIFY IF
 32" LONG SHUTTERS WIL BE ADEQUATE.
 5-PROVIDE PRODUCT APPROVAL FOR:
 A)SINGLE ENTRY DOOR WITH ONE SIDELITE
 ASSEMBLY AS SHOWN ON PLANS. NOTE: NEED
 LEGIBLE DRAWINGS ALSO.
 B)SINGLE HUNG WINDOWS W/ MATCHING DWGS.
 C)GLASS BLOCK UL LISTING AND COMPLETE
 SPECIFICATIONS FOR ONE HOUR FIRE RATED
 ASSEMBLY AS REQ'D BY TABLE 600 FBC.
 D)FIXED RECTANGULAR WINDOW WITH MATCHING
 DRAWINGS. NOTE: SEE SIZE ON PLANS AND
 ELEVATIONS. CLARIFY IF THERE ARE THREE
 FIXED WINDOWS MULLED TOGETHER OR IF
 IT'S ONE BIG RECTANGULAR WINDOW.
 6-PROVIDE GLASS BLOCK ASSEMBLY DETAIL
 FOR ONE HOUR FIRE RATING. SEE UL SPECS
 FOR PRODUCT APPROVAL SUBMITTED.
 7-SEE PLANS FOR ADDITIONAL COMMENTS AND
 RETURN REVIEWED SET AFTER CORRECTIONS
 ARE DONE TO ORIGINALS TO EXPEDITE
 REVIEW.
 8-DRAWINGS 9/14 IS NOT CLEAR. IT DOESN'T
 SHOW THE STORM PANEL GLASS SEPARATION,
 EDGE DISTANCE AND TYPE OF TRACK TO
 RECEIVE THE STORM PANELS. SEE PRODUCT
 APPROVAL TO VERIFY THAT THIS TYPE OF
 INSTALLATION WILL WORK.
 9-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR
 FIXED WINDOW. DETAIL SUBMITTED DOESN'T
 APPLY. WINDOW IS LOCATED ON MASONRY
 WALL, NOT IN FRAMED WALL.
 10-CLEARLY IDENTIFY ROOF ZONE #3 ON ROOF
 FRAMING PLAN. NOTE: ZONE IS NOT ONLY
 AT GABLE ENDS. SEE TABLE 2306.1 CITY
 AMENDMENTS TO FBC 2001.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-07-08 Cont ID  
Sent By btrobaug Date 2002-06-19 Time 14:05 Rev Time 0.00
Received By jgomez Date 2002-07-08 Time 14:06 Sent To  
Notes
2002-07-08 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-REVISE ATTIC ACCESS SIZE. 36"MIN. NOT
 30". SEC 2309.6 FBC 2001.
 3-CLARIFY SIZE OF 34SH WINDOW. TYPICALLY
 34SH WINDOW DOESN'T ALLOW 24" CLEAR HT
 OPENING. SEC. 1005.4.4 FBC 2001.
 IS THIS A CUSTOM MADE WINDOW?
 4-PROVIDE SOIL TEST REPORT.
 5-STORM SHUTTERS:
 A)PROVIDE COMPLETE INSTALLATION SCHEDULE
 AND KEY PLAN. SEE CITY SAMPLE.
 B)CLEARLY INDICATE ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO
 (CONCRETE BLOCK OR CONCRETE)
 6-PROVIDE PRODUCT APPROVAL FOR:
 A)SINGLE ENTRY DOOR WITH ONE SIDELITE AS
 SHOWN ON PLANS & WITH LEGIBLE AND
 COMPLETE DRAWINGS (NOT HALF COPIES).
 B)COMPLETE PAN AMERICAN WINDOW MULLION.
 C)SINGLE HUNG PRODUCT APPROVAL REPORT
 DOESN'T MATCH DRAWINGS SUBMITTED.
 D)1 HR FIRE RATED GLASS BLOCK ASSEMBLY.
 E)FIXED RECTANGULAR WINDOW WITH THE
 SIZE SHOWN ON PLANS.
  
 7-PROVIDE UPDATED ORIGINAL LETTER FOR
 MASONRY USED AND ADDRESSED TO THE CITY
 OF W.P.B. AND THE CONTRACTOR. ALSO,
 SPECIFIED PROJECT DELIVERED TO.
 8-SHEET C-1 IS MISSING THE INTERNAL
 PRESSURE COEFFICIENT AS REQUIRED BY
 SEC. 1606.1.7 FBC 2001.
 9-PROVIDE COMPLETE GABLE END SECTION/
 DETAIL AT FRONT ELEVATION SHOWING
 CONTINUITY REQUIRED BY SEC. 2117.1.2
 FBC 2001.
 10-REVISE GLASS BLOCK DETAILS. NEED ONE
 HR FIRE RATED ASSEMBLY AS REQUIRED BY
 TABLE 600 FBC 2001. SEE UL LISTING FOR
 ONE HR FIRE RATED ASSEMBLY SPECS.
 11-SEE PLANS FOR ADDITIONAL COMMENTS AND
 RETURN REVIEWED SET TO EXPEDITE REVIEW
 12-SPECIFY SUPPORTS FOR CONCRETE SLAB
 WWM. SEE SECTION 1909.3 FBC 2001.
 13-CLARIFY NOTE #42 ON SHEET A-1. SEE
 STORM SHUTTERS PRODUCT APPROVAL TO
 VERIFY IF PROPOSED INSTALLATION WORKS.
 CONSIDER THE REQUIRED GLASS DISTANCE.
 14-ENERGY CALCULATIONS: REVISE UNDER
 ATTIC AREA. SEE SEC. 602.1.ABC.1.2 OF
 CHAPTER 13 FBC 2001.
 15-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR
 FIXED WINDOWS AS REQUIRED ON PRODUCT
 APPROVAL SUBMITTED.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-18 Cont ID  
Sent By sgraham Date 2002-06-18 Time 07:47 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***