Plan Review Details - Permit 02060543
| Plan Review Stops For Permit 02060543 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-07-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-21 |
Time |
11:30 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-07-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-17 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-07-17 |
Time |
06:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-06-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-06-19 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-06-19 |
Time |
11:07 |
Sent To |
M |
|
| Notes |
| 2002-06-19 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | AND RESUBMIT FOR REVIEW. | | | | | | 1} THE RISER DIAGRAM SHOWS A 200A/2P | | | DISCONNECT AND A 200 AMP PANEL,BUT THE | | | PLANS ONLY SHOW A PANEL.PLEASE CLARIFY. | | | | | | 2} THE WIRE SHOWN GOING TO THE 200 AMP | | | PANEL IS LISTED AS #1,WHICH IS ONLY | | | GOOD FOR 150 AMPS PER 310-15(B)(6). | | | AND THE PANEL IS SHOWN AS MLO.PLEASE | | | CLARIFY. | | | | | | 3} THE DRAWING DOES NOT SHOW HOW THE | | | BRANCH CIRCUITS ARE BEING REFED. PLEASE | | | NOTE IF USING THE EXISTING PANEL AS A | | | JUNCTION BOX IT MUST BE ACCESSIBLE PER | | | 370-29. | | | | | | 4} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 5} PLEASE NOTE THAT THE A COUNTER | | | RECEPTACLE IS REQUIRED NEXT TO THE | | | REFER/ICE MAKER PER 210-52(C)(1),IF 1'. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-06-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-06-19 |
Time |
12:22 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-06-21 |
Time |
10:53 |
Sent To |
B |
|
| Notes |
| 2002-06-21 00:00:00 | MECHANICAL PERMIT 02060544 | | | | | | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | | | | HOOD FOR GAS COOKTOP - | | | PLEASE PROVIDE MANUFACTURER INSTALLATION | | | INSTRUCTIONS AT INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-06-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-06-18 |
Time |
16:53 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2002-06-18 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2002-07-29 |
|
|
Cont ID |
|
| Sent By |
khenry |
Date |
2002-07-29 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
khenry |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |