Plan Review Details - Permit 02060449
| Plan Review Stops For Permit 02060449 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2003-08-04 |
Time |
17:07 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-07-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
11:49 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-08-01 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-08-01 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2002-08-01 00:00:00 | ************** UNSAT **************** | | | | | | REVISION SUBMITTED FOR NEW TEMPORARY | | | ELECTRICAL SERVICE TO FEED CAROUSEL. | | | | | | 1)NOTE: PLEASE CORRELATE CONDUIT SIZES | | | THAT ARE NOTED. PLEASE NOTE #1 SAYS | | | 4" CONDUITS AND NOTES #6 AND #9 SHOW | | | 2" CONDUITS?? | | | | | | 2)NOTE:PLEASE NOTE;NOTE #6 SHOWS AN | | | EQUIPMENT GROUNDING CONDUCTOR FROM | | | TRANSFORMER/FPL TO METER. PLEASE NOTE | | | THAT THIS IS PARALLELING THE NEUTRAL. | | | 250-24 | | | | | | 3)NOTE: PLEASE NOTE THAT CONTRACTOR | | | NEEDS TO SUBMIT PERMIT APPLICATION FOR | | | TEMP POWER/FEED. | | | | | | 4)NOTE: PLEASE SHOW LOCATION OF NEW | | | DISC ON PLANS. PLEASE NOTE ONLY PULL | | | BOX IS SHOWN? | | | | | | 5)NOTE: PLEASE PROVIDE INFORMATION FOR | | | DISTANCE FROM TRANSFORMER TO PANEL. | | | / PROVIDE VOLTAGE DROP CALCUALTIONS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-07-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-05 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-07-05 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2002-07-05 00:00:00 | I DID NOT SIGN OFF ON ANY REVIEW EXCEPT | | | ELECTRICAL,LEA SMITH MADE THOSE ENTRIES | | | ON MY COMPUTER./WRT |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2002-07-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-05 |
Time |
12:08 |
Rev Time |
2.00 |
| Received By |
mamini |
Date |
2002-07-05 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-04 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
| 2003-08-04 00:00:00 | TO LM DESK |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
N |
Date |
2002-07-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2002-07-09 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2002-07-09 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2002-07-03 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-07-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2002-07-09 |
Time |
15:31 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
2002-07-09 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2002-07-09 00:00:00 | SEE APPROVAL ON PLANS BY SHIRLEY GRAHAM |
|
|
|