Plan Review Details - Permit 02060418
Plan Review Stops For Permit 02060418
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-20 Cont ID  
Sent By dpalmer Date 2002-08-20 Time 08:29 Rev Time 0.00
Received By dpalmer Date 2002-08-20 Time 08:29 Sent To M
Notes
2002-08-20 00:00:00NOTES REDLINED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-19 Cont ID  
Sent By dpalmer Date 2002-06-19 Time 06:27 Rev Time 0.00
Received By dpalmer Date 2002-06-19 Time 06:27 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-01-23 Cont ID  
Sent By pkrauss Date 2003-01-23 Time 09:53 Rev Time 0.30
Received By pkrauss Date 2003-01-23 Time 09:45 Sent To  
Notes
2003-01-23 00:00:00MECHANICAL PERMIT 02060419

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-26 Cont ID  
Sent By pkrauss Date 2002-08-26 Time 16:47 Rev Time 0.45
Received By pkrauss Date 2002-08-26 Time 15:18 Sent To R
Notes
2002-08-26 00:00:00PROVISO:
  
 PLEASE NOTE INSTALLATION INSTRUCTIONS
 FOR THE GE MONOGRAM COOKING CENTER
 SHALL BE LOCATED OUTDOORS.
  
 PLEASE PROVIDE INSTALLATION INSTRUCTIONS
 FOR THE FIREPLACE (FLUE SYSTEM) ON THE
 JOBSITE AT THE TIME OF INSPECTION.
  
 SHOULD GAS DRYER BE INSTALLED -
 SHOW COMPLIANCE FOR COMBUSTION AIR AS
 PER 2001 FBC(M) CHAPTER 7.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-06-18 Cont ID  
Sent By dpalmer Date 2002-08-20 Time 08:29 Rev Time 0.35
Received By pkrauss Date 2002-06-18 Time 13:23 Sent To  
Notes
2002-06-18 00:00:00DENIED:MECHANICAL PERMIT 02060419
  
 PLEASE PROVIDE MANUAL J CALCULATIONS AS
 PER 2001 FBC CHAPTER 13.
  
 CONDENSATE SHALL DISCHARGE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE AS
 PER 2001 FBC 1503.4.4.
  
 2001 FBC(M) 402.2 - NATURAL VENTILATION
 FOR OUTSIDE AIR REQUIRMENT. SHOW
 COMPLIANCE FOR THE MINIMUM OPENABLE AREA
 TO THE OUTDOORS. (4 PERCENT OF THE FLOOR
 AREA BEING VENTILATED) OR TABLE 403.3
 FOR MECHANICAL VENTILATION.
  
 SMOKE DETECTORS SHALL BE INSTALLED IN
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTORS
 WITH NOTIFICATION TO ALARM/STOBE OR AREA
 SMOKE DETECTORS. 2001 FBC(M) 606.4.1
  
 SHOW COMPLIANCE FOR COMBUSTION AIR AS
 PER 2001 FBC(M) CHAPTER 7.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-16 Cont ID  
Sent By kstevens Date 2003-01-16 Time 09:22 Rev Time 0.75
Received By kstevens Date 2003-01-16 Time 09:15 Sent To  
Notes
2003-01-16 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-15 Cont ID  
Sent By jleech Date 2002-06-15 Time 06:58 Rev Time 0.33
Received By jleech Date 2002-06-15 Time 06:57 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-09-03 Cont ID  
Sent By pkrauss Date 2002-08-27 Time 10:14 Rev Time 1.00
Received By jwitmer Date 2002-09-03 Time 10:36 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-07-05 Cont ID  
Sent By jwitmer Date 2002-07-05 Time 15:40 Rev Time 0.00
Received By jwitmer Date 2002-07-05 Time 15:40 Sent To  
Notes
2002-07-05 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02060418
 ADD: 7342 HORIZON DRIVE
 CONT: PGM BUILDERS
 TEL: (561) 627-2551
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ******NOTE******
 FIRST PERMIT APP 6/7/02
 SECOND SUB JUNE 17TH
 THIRD SUBMITTAL JULY 3RD
 WHEN ADDITIONAL INFORMATION IS SUBMITTED
 BEFORE ALL REVIEWS ARE COMPLETE IT CAN
 BE CONSTRUED AS THE 2ND & 3RD RESUBS!!!!
 THE 3RD RESUB 10% OF PERMIT FEE, SEE
 ATTACHMENT FOR 4TH!!!!!
  
 1)- SHEET A-2 FOOTING A-2 NEXT TO POOL,
 1803.1.3 EXCAVATION FOR ANY PURPOSE
 SHALL NOT EXTEND WITHIN 1 FT OF THE
 ANGLE OF REPOSE OR NARURAL SLOPE OF THE
 SOIL UNDER ANY FOOTING OR FOUNDATION,
 UNLESS SUCH FOOTING OR FOUNDATION IS
 FIRST PROPERLY UNDERPINNED OR PROTECTED
 AGAINST SETTLEMENT.
  
 2) SHEET A-2 VS SITE ENGINEERING, THE
 BREAKFAST NOOK INDIVATES (2) STEEL
 COLUMNS C-17 WHICH ARE NOT REFLECTED
 ON THE SITE SPECIFIC ENGINEERING.WALL
 THICKNESS NOT GIVEN ON COLUMN?
  
 3)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
  
 4)FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
 IF FIBERMESH IS USED IN THE MAN. SPEC.
 EXSPANSION JOINTS NOT REQUIRED.
  
 5) B13/16, PLEASE INDICATE HOW ACI 318.
 11.6 COMBINED SHEAR & TORSION WILL DEAL
 WITH THE ECENTRIC LOADING OF THE BEAM,
 TRANSFERRED TO BEAM OR COLUMNS?
  
 6) 905.2.1 SMOKE DETECTORS SHALL BE PLAC
 ED IN SLEEPING ROOMS AND OUTSIDE SLEEP-
 ING ROOMS. THEY SHOULD BE PLACED AT THE
 HIGHEST POINT IN THE CEILINGS NOT TIERED
 CEILINGS.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-11 Cont ID  
Sent By sgraham Date 2002-06-11 Time 12:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***