Plan Review Details - Permit 02060381
Plan Review Stops For Permit 02060381
Review Stop AD ADDRESSING
Rev No 2 Status F Date 2004-12-14 Cont ID  
Sent By shill Date 2004-12-14 Time 17:27 Rev Time 0.00
Received By shill Date 2004-12-14 Time 17:27 Sent To P
Notes
2004-12-14 00:00:00****CORRECTIONS****
 AWNING SHOPS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)AS PER CONVERSATION WITH L.TYLKA,
 PE, ENGINEERING SHEETS WITH REACTION
 LOADS ARE MISSING FROM THIS SUBMITTAL.
 PLEASE SUBMIT.

Review Stop AD ADDRESSING
Rev No 1 Status P Date 2004-12-13 Cont ID  
Sent By shill Date 2004-12-13 Time 14:32 Rev Time 1.00
Received By shill Date 2004-12-13 Time 14:32 Sent To PC
Notes
2004-12-13 00:00:00SUBMITTAL - MEZZANINE LADDER SHOPS
 PREPARED BY FRANK L. BENNARDO, PE

Review Stop B BUILDING (STRUCTURAL)
Rev No 97 Status P Date 2005-01-21 Cont ID  
Sent By shill Date 2005-01-21 Time 12:59 Rev Time 0.00
Received By shill Date 2005-01-21 Time 12:59 Sent To PC
Notes
2005-01-21 00:00:00DINING ROOM SOFFIT FRAMING PERPARED BY
 FRANK BENNARDO PE DATED 7/14/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 96 Status F Date 2005-01-21 Cont ID  
Sent By shill Date 2005-01-21 Time 11:17 Rev Time 2.00
Received By shill Date 2005-01-21 Time 11:17 Sent To PC
Notes
2005-01-21 00:00:00****CORRECTIONS****
 REVISED AWNING SHOPS
 PREPARED BY L.TYLKA, PE
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE ICBO SUBMITTED (REPORT NO.
 1372, JUNE 1992) IS EXPIRED.THE
 CURRENT REPORT IS MARCH 2000.CANNOT
 USE EXPIRED REPORTS AS JUSTIFICATION.
  
 2.)PLEASE DIFFERENTIATE BETWEEN
 GRAVITY LOAD AND WIND LOAD IN THE
 LETTER
 (PARAGRAPH 2).WHICH IS THE WORST
 LOADING CASE, GRAVITY OR WIND?BASED
 ON
 OUR TELEPHONE CONVERSATION, THE ANCHORS
 WERE DOUBLED AS A RESULT OF LOSS OF
 CAPACITY DUE TO SUBSTRATE CONDITIONS.
 THE PLAN SHOWS ADDITIONAL ANCHORS AT
 THE
 BOTTOM ONLY. DOES THIS MEAN THAT THE
 SAME ANCHORS AT THE TOP SPECIFIED FOR
 CONCRETE WERE SUFFICIENT FOR HOLLOW
 BLOCK FOR GRAVITY LOADS?
  
 I THANK YOU FOR YOUR PATIENCE AND
 CONTINUING ASSISTANCE IN RESOLVING THIS
 MATTER.PLEASE FEEL FREE TO CONTACT ME
 AT YOUR CONVENIENCE SHOULD YOU NEED
 ADDITIONAL INFORMATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 95 Status P Date 2005-01-20 Cont ID  
Sent By shill Date 2005-01-20 Time 16:37 Rev Time 0.00
Received By shill Date 2005-01-20 Time 16:37 Sent To PC
Notes
2005-01-20 00:00:00FRAMING SHOPS FOR BROW & HIGH ROOF
 PREPARED BY M.NALYWAJKO PE DATED
 9/30/04
  
 FRAMING FOR OCTAGON @ AL ROOF
  
 FRAMING AT HIGH ROOF SHOPS
  
 MECHANICAL ROOM FRAMING

Review Stop B BUILDING (STRUCTURAL)
Rev No 94 Status P Date 2005-01-20 Cont ID  
Sent By shill Date 2005-01-20 Time 16:19 Rev Time 0.00
Received By shill Date 2005-01-20 Time 16:19 Sent To PC
Notes
2005-01-20 00:00:00FRAMING AT GATEHOUSE, PREPARED BY
 M.NALYWAJKO DATED 1/4 05

Review Stop B BUILDING (STRUCTURAL)
Rev No 93 Status P Date 2005-01-12 Cont ID  
Sent By shill Date 2005-01-12 Time 11:32 Rev Time 0.50
Received By shill Date 2005-01-12 Time 11:32 Sent To PC
Notes
2005-01-12 00:00:00SUBMITTALS
  
 OVERHEAD ROLLUP DOOR PRODUCT APPROVALS
 RFI 523
 RFI 476R (AHU STANDS)

Review Stop B BUILDING (STRUCTURAL)
Rev No 92 Status F Date 2004-01-14 Cont ID  
Sent By shill Date 2005-01-06 Time 09:05 Rev Time 1.00
Received By shill Date 2005-01-06 Time 09:05 Sent To PC
Notes
2005-01-06 00:00:00****CORRECTIONS****
 AWNING SHOPS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)AS PER CONVERSATION WITH L.TYLKA,
 PE, ENGINEERING SHEETS WITH REACTION
 LOADS ARE MISSING FROM THIS SUBMITTAL.
 PLEASE SUBMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 91 Status F Date 2005-01-06 Cont ID  
Sent By shill Date 2005-01-06 Time 08:22 Rev Time 1.00
Received By shill Date 2005-01-06 Time 08:22 Sent To PC
Notes
2005-01-06 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
 CALCS FOR HOUSEKEEPING PAD AND 6TH
 STORY
 STEEL DECK
  
 1.)THE ACI REFERENCE USED MUST BE IN
 ACCORDANCE WITH FBC CHAPTER 35, WHICH
 REFERENCES ACI 318-02.THE INFORMATION
 SUBMITTED WAS FROM ACI 318-93.
  
 2.)THE CALCS STILL SHOW 4.22%
 OVERSTRESS (WAS 2% PREVIOUSLY), WITH
 THE
 WATER AS A DEAD LOAD.THE CALCS
 SUBMITTED MUST BE COMPLIANT WITH
 FBC1601.2.1.IF THE CONCRETE WAS
 STRONGER THAN DESIGN SPECIFIED, AND
 THIS
 IS YOUR JUSTIFICATION, PLEASE INCLUDE
 IT
 IN THE CALCS TO SHOW CODE COMPLIANCE.
  
 3.)WHY WILL THE HOT WATER TANK NOT BE
 FULL 99% OF THE TIME?DOES THIS TANK
 WORK DIFFERENTLY FROM OTHER TANKS,
 WHICH
 REFILL AS HOT WATER LEAVES THE TANK, SO
 ARE ALWAYS FULL?IF THE WATER LEVEL
 CHANGES WITHIN THE TANK, HOW DOES THE
 TANK ADDRESS THE VACUUM CREATED?
 PLEASE
 SUBMIT PRODUCT DATA FOR CLARIFICATION.
 THE CALCS WERE RUN AT 90% FULL; PROVIDE
 SOME DOCUMENTATION FOR THIS ASSUMPTION.
  
 4.)PLEASE NOTE THAT THE ORIGINAL CALCS
 SUBMITTED (WITH A MATH ERROR, AND TANK
 AS A DEAD LOAD) WHEN RUN WITHOUT THE
 MATH ERROR AND THE TANK AS A LIVE LOAD
 APPEARS TO SHOW A 28% OVERSTRESS.
  
 5.)IN ADDRESSING THE COMMENT
 REGARDING
 THE STEEL DECK, I BELIEVE YOU ARE
 STATING THAT THE DENSGLASS CAN ACT WITH
 THE STEEL DECK AS THE MWFRS.THE CALCS
 CANNOT SHOW AN OVERSTRESS, FBC1601.2.1.
 ALSO YOUR NOTE STATES THAT THE
 DENSGLASS
 AT 3.5PSF WILL ACCOUNT FOR THE 2%
 INADEQUACY, BUT ISN'T THE STEEL DECK
 3.5% OVERSTRESSED?PLEASE RERUN THE
 CALCULATIONS INCLUDING THE DENSGLASS IF
 THAT IS HOW YOU ARE SHOWING CODE
 COMPLIANCE.
  
  
  
 SENT VIA FAX TO PAUL KING, PE AND TO
 WHITING TURNER

Review Stop B BUILDING (STRUCTURAL)
Rev No 90 Status P Date 2004-12-22 Cont ID  
Sent By shill Date 2004-12-22 Time 16:47 Rev Time 8.00
Received By shill Date 2004-12-22 Time 16:47 Sent To PC
Notes
2004-12-22 00:00:00NOAS FOR DOORS, HORTON AUTO DOORS -
 REVISED LETTER FROM PAUL KING PE TO
 INCLUDE ALL 1ST FLOOR EXTERIOR DOORS
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 89 Status F Date 2004-12-22 Cont ID  
Sent By shill Date 2004-12-22 Time 13:19 Rev Time 0.00
Received By shill Date 2004-12-22 Time 13:19 Sent To PC
Notes
2004-12-22 00:00:00****CORRECTIONS****
 CALCULATIONS, HOUSEKEEPING PAD AND
 STEEL
 DECK
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PLEASE SEE BUILDING REVIEW #54,
 ITEM #4, HOW HAVE YOU ARRIVED AT 170PSF
 DESIGN (125+20+20=165)?ALSO, A HOT
 WATER TANK IS A LIVE LOAD, NOT A DEAD
 LOAD.
  
 2.)COMMENTS FROM REVIEW #85 STILL
 APPLY.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 88 Status P Date 2004-12-22 Cont ID  
Sent By shill Date 2004-12-22 Time 10:25 Rev Time 0.00
Received By shill Date 2004-12-22 Time 10:25 Sent To PC
Notes
2004-12-22 00:00:00NOA - OUTSWING DOOR
 DOORS S81, SD4, S17, C440, C439, C438,
 A144A

Review Stop B BUILDING (STRUCTURAL)
Rev No 87 Status F Date 2004-12-22 Cont ID  
Sent By shill Date 2004-12-22 Time 10:59 Rev Time 0.00
Received By shill Date 2004-12-21 Time 12:09 Sent To PC
Notes
2004-12-22 00:00:00****CORRECTIONS****
 VARIOUS SUBMITTALS; CLARIFICATION
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE FAX RECEIVED IN REGARDS TO THE
 HORTON AUTOMATIC DOORS, C101, C151 AND
 A123, IS ACCEPTABLE.PLEASE SUBMIT
 ORIGINALS, SIGNED & SEALED.
  
 2.)THE LETTER FROM PAUL KING, PE
 DATED
 NOVEMBER 11, 2004 RE: WINDOW PRESSURES
 STATING THAT 102B AND B102C (OVERHEAD
 DOORS) SHALL BE DESIGNED TO ACCOMODATE
 ZONE 4 PRESSURES IS NOT CLEAR.ARE
 THEY
 ALL LOCATED IN ZONE 4 OR ARE YOU
 REVISING THE ZONE 5 PRESSURES STATED ON
 SHEET S2.19?
  
 3.)THE LETTER FROM PAUL KING DOES NOT
 ADDRESS THE
 SLIDING GLASS DOORS OR THE NOAS
 SUBMITTED (02-0712.03, 02-0712.01).
  
 4.)REGARDING NOA 02-0712.03(DP+-70)
 FOR DOORS A131, A122A, B1014, AND
 NOA02-0712.01 FOR DOOR A131A ARE ANY OF
 THESE DOORS LOCATED IN ZONE 5, AND IS
 WATER INFILTRATION REQUIRED?
  
 5.)ENGINEERING FROM AL-FAROOQ FOR THE
 SLIDING GLASS DOORS (SHEET SD-03-44)
 PROVIDE DESIGN PRESSURES. IT IS NOT
 CLEAR WHY THEY ARE LOWER THAN THE TEST
 REPORT.SINCE THE DOR
 SPECIFIES DESIGN PRESSURES FOR THE
 BUILDING (SHEET S2.19) THEY APPEAR TO
 BE
 DESIGN PRESSURE LIMITATIONS FOR THE
 SLIDING GLASS DOORS.THEY ARE
 NONCOMPLIANT FOR ZONE 5 (REQUIREMENT OF
 -77.4, -75.05, -73.2).IF ZONE 5 IS
 WITHIN 15' OF A CORNER AS STATED ON
 S2.19, IT APPEARS THAT ALL OF THE
 SLIDING GLASS DOORS, WITH THE EXCEPTION
 OF SOME LOCATED AT THE POOL ENCLOSURE,
 ARE LOCATED IN ZONE
 5.PLEASE SUBMIT NEW TEST REPORTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 86 Status P Date 2004-12-13 Cont ID  
Sent By shill Date 2004-12-13 Time 13:12 Rev Time 2.00
Received By shill Date 2004-12-13 Time 13:12 Sent To  
Notes
2004-12-13 00:00:00REVISIONS - STRUCTURAL SUBMITTALS AND
 RFIS INCORPORATED INTO PLAN
 DATED 5/10/04
 S2.02 - S2.08, S2.10, S2.12, S2.14,
 S2.16, S2.18, S2.21, S2.23, S2.33M

Review Stop B BUILDING (STRUCTURAL)
Rev No 85 Status F Date 2004-12-13 Cont ID  
Sent By shill Date 2004-12-09 Time 14:36 Rev Time 3.00
Received By shill Date 2004-12-09 Time 14:36 Sent To PC
Notes
2004-12-09 00:00:00****CORRECTIONS****
 HOUSEKEEPING PAD, STEEL DECK
 CALCULATIONS; DOOR PRODUCT APPROVALS &
 SHOPS
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)FBC1601.2.1 EVERY BUILDING AND
 STRUCTURE SHALL BE OF SUFFICIENT
 STRENGTH TO
 SUPPORT THE LOADS AND FORCES
 ENCOUNTERED, OR COMBINATIONS THEREOF,
 WITHOUT
 EXCEEDING IN ANY OF ITS STRUCTURAL
 ELEMENTS THE STRESSES PRESCRIBED
 ELSEWHERE IN THIS CODE.CALCULATIONS
 SUBMITTED WHICH INDICATE 2%
 (HOUSEKEEPING PAD) AND 5% (STEEL ROOF
 DECK) OVERSTRESSES ARE NOT CODE
 COMPLIANT.PLEASE ADDRESS.
  
 2.)SEE PREVIOUS CORRECTION LISTS.
 PRODUCT APPROVALS SUBMITTED ARE
 COMPLIANT FOR ZONE 4 BUT NOT FOR ZONE 5.
 I CANNOT DETERMINE FROM THE PLAN WHERE
 ZONE 5 IS.PLEASE PROVIDE INFORMATION
 REQUESTED - OF THE OPENINGS, WHICH ONES,
 IF ANY, ARE IN ZONE 5?
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 84 Status F Date 2004-12-09 Cont ID  
Sent By shill Date 2004-12-09 Time 13:16 Rev Time 1.00
Received By shill Date 2004-12-09 Time 13:16 Sent To  
Notes
2004-12-09 00:00:00****CORRECTIONS****
 AWNING SHOPS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PLEASE PROVIDE CALCULATIONS FOR
 ANCHORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 83 Status P Date 2004-12-06 Cont ID  
Sent By shill Date 2004-12-06 Time 08:55 Rev Time 0.00
Received By shill Date 2004-12-06 Time 08:55 Sent To PC
Notes
2004-12-06 00:00:00 
 FURRING DETAIL AT ELEVATOR, RFI 495R

Review Stop B BUILDING (STRUCTURAL)
Rev No 82 Status P Date 2004-11-30 Cont ID  
Sent By shill Date 2004-11-30 Time 07:41 Rev Time 2.00
Received By shill Date 2004-11-30 Time 07:22 Sent To PC
Notes
2004-11-30 00:00:00CBAA CASE 1263
  
 PROVISO - SUBMIT SGD & SWING DOOR
 PRODUCT APPROVALS
  
 SUBMIT FLORIDA PE SEAL ON TEST REPORT
 (SEE DOCUMENT CONTROL ADDENDUM
 #01-41790.00)

Review Stop B BUILDING (STRUCTURAL)
Rev No 81 Status P Date 2004-12-07 Cont ID  
Sent By shill Date 2004-11-29 Time 08:46 Rev Time 3.00
Received By shill Date 2004-11-29 Time 08:46 Sent To PC
Notes
2004-11-29 00:00:00****CORRECTIONS****
 POOL ENCLOSURE
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 PLEASE PROVIDE A TITLE BLOCK FOR THE
 ENGINEER WITH ALL INFORMATION REQUIRED
 BY FAC61G15-23.002.SEE ATTACHED FOR
 ROBERT MCCLOY; ADDRESS IS NOT THE SAME
 AS ON THE PLAN.I COULD NOT FIND A
 CERTIFICATE OF AUTHORIZATION FOR
 "ENGINEERED GLAZING SYSTEMS".
  
  
 SEE CBAA CASE #1263
  
 PROVISO - SUBMIT PRODUCT APPROVALS FOR
 SGD AND DOOR
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 80 Status F Date 2004-11-13 Cont ID  
Sent By shill Date 2004-11-13 Time 11:52 Rev Time 0.50
Received By shill Date 2004-11-13 Time 11:52 Sent To PC
Notes
2004-11-13 00:00:00****CORRECTIONS****
 REVISION TO BALCONY RAILING CONNECTION
 PREPARED BY GW VARMAAS, PE
  
 1.)SUBMITTALS ARE TO BE REVIEWED BY
 THE DESIGNER OF RECORD.
  
 2.)THE LANGUAGE ON THE LETTER REFERS
 TO MASONRY WALL; ALLOWABLE LOADS
 PROVIDED BY HILTI ARE FOR CONCRETE.
 CLARIFY.
  
 3.)THE DESIGN LOAD IS TO CONFORM TO
 FBC1608.2.2.1 THROUGH 1608.2.2.4.
 PROVIDE CALCS.
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 79 Status P Date 2004-08-19 Cont ID  
Sent By shill Date 2004-08-19 Time 10:58 Rev Time 0.50
Received By shill Date 2004-08-19 Time 10:58 Sent To PC
Notes
2004-08-19 00:00:00POST TUBE COLUMNS, PREPARED BY AM SCALA
 PE RE: ROOFDATED 4/16/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 78 Status F Date 2004-08-17 Cont ID  
Sent By csiegber Date 2004-08-18 Time 13:02 Rev Time 0.50
Received By shill Date 2004-08-17 Time 11:03 Sent To PC
Notes
2004-08-17 00:00:00****CORRECTIONS****
 RFI 476R, A/C STAND CALCS PREPARED BY
 YM AKDOREK, PE; 2ND SUBMITTAL
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PLEASE SUBMIT ORIGINAL SIGNED,DATED
 AND SEALED COPIES, INCLUDING CA NUMBER
 FOR THE FIRM, AS REQUIRED BY FAC61G15-
 23.002.A PHOTOCOPY OF A SIGNATURE IS
 NOT ACCEPTABLE PER FBPE.IF THE
 ENGINEER HAS ANY QUESTIONS, PLEASE HAVE
 HIM CALL EITHER ME OR FBPE FOR
 CLARIFICATION.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 77 Status F Date 2004-08-17 Cont ID  
Sent By shill Date 2004-08-17 Time 10:39 Rev Time 0.50
Received By shill Date 2004-08-17 Time 10:39 Sent To PC
Notes
2004-08-17 00:00:00****CORRECTIONS****
 DINING ROOM SOFFIT FRAMING PREPARED BY
 FRANK BENNARDO, PE, INC.
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE DESIGN INFORMATION CONTAINS AN
 INCORRECT IMPORTANCE FACTOR.
  
 2.)THE PRINTED NAME AND LICENSE NUMBER
 OF THE PERSON SEALING THE DRAWING, AS
 WELL AS THE CA NUMBER FOR THE FIRM, IS
 TO BE ON EACH SHEET.FAC61G15-23.002.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 76 Status P Date 2004-08-17 Cont ID  
Sent By shill Date 2004-08-17 Time 10:33 Rev Time 1.00
Received By shill Date 2004-08-17 Time 10:33 Sent To PC
Notes
2004-08-17 00:00:00YKK GLASS SHOPS
  
 ARCH DETAIL PREPARED BY FRANK BENNARDO,
 PE

Review Stop B BUILDING (STRUCTURAL)
Rev No 75 Status F Date 2004-08-17 Cont ID  
Sent By shill Date 2004-08-17 Time 10:23 Rev Time 0.50
Received By shill Date 2004-08-17 Time 10:23 Sent To PC
Notes
2004-08-17 00:00:00****CORRECTIONS****
 OVERHEAD DOOR PRODUCT APPROVALS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)ARE ANY OF THESE DOORS IN ZONE 5?
 THEY ARE CODE COMPLIANT FOR ZONE 4 BUT
 NOT FOR ZONE 5.PLEASE HAVE THE
 DESIGNER OF RECORD ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 74 Status F Date 2004-08-10 Cont ID  
Sent By shill Date 2004-08-09 Time 16:28 Rev Time 3.00
Received By shill Date 2004-08-09 Time 16:28 Sent To FIRE
Notes
2004-08-09 00:00:00****CORRECTIONS****
 POOL ENCLOSURE, CBAA CASE 1263
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PLEASE PROVIDE TEST REPORTS FOR
 THE SLIDING GLASS DOORS, IMPACT
 PROTECTION, SWING DOORS AS REQUESTED.
 THE SUBMITTALS FOR THE DOORS AND
 SLIDING GLASS DOORS WHICH WERE BROUGHT
 IN PREVIOUSLY HAVE NOT BEEN APPROVED AT
 THIS TIME.THE STEEL SWING DOORS
 SUBMITTED AT THAT TIME WERE NOT
 COMPLIANT FOR ZONE 5, WHICH IS WITHIN
 15' OF THE CORNER.IT APPEARS THAT
 THE EGRESS DOOR FOR THIS SCREEN
 ENCLOSURE IS IN ZONE 5.
  
 THE SLIDING GLASS DOORS SUBMITTAL
 DID NOT CONTAIN A TEST REPORT.PLEASE
 SUBMIT.
  
 2.)THE CALCULATIONS REQUIRE A TITLE
 BLOCK.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 73 Status P Date 2004-08-10 Cont ID  
Sent By shill Date 2004-08-09 Time 14:33 Rev Time 1.00
Received By shill Date 2004-08-09 Time 14:33 Sent To  
Notes
2004-08-09 00:00:00RFI 391
 SIDEWALK CONCRETE SUBMITTAL

Review Stop B BUILDING (STRUCTURAL)
Rev No 72 Status F Date 2004-08-02 Cont ID  
Sent By shill Date 2004-08-02 Time 09:03 Rev Time 0.50
Received By shill Date 2004-08-02 Time 09:02 Sent To  
Notes
2004-08-02 00:00:00****CORRECTIONS****
 RFI 391 RE: ELEVATOR SHAFT VENT LOCATION
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)DOCUMENTS PREPARED BY AN ARCHITECT
 SUBMITTED FOR PUBLIC RECORD ARE TO
 BE SIGNED, SEALED AND DATED FS481.

Review Stop B BUILDING (STRUCTURAL)
Rev No 71 Status F Date 2004-07-29 Cont ID  
Sent By shill Date 2004-07-28 Time 17:22 Rev Time 4.00
Received By shill Date 2004-07-28 Time 17:21 Sent To  
Notes
2004-07-28 00:00:00****CORRECTIONS****
 SLIDING GLASS DOOR SUBMITTAL & SHOPS
 DENIED PRODUCT APPROVALS (DOORS, AUTO)
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SHEETS REGARDING THE SLIDING
 GLASS DOOR HAVE BEEN REMOVED FROM THE
 APPROVED SUBMITTAL; SHEETS 19, 20, R1,
 R2, R3, R4 (FROM CALCS), SHEETS 9-11,
 17-19 (FROM SHOPS).PROVIDE TEST
 REPORT FBC1707.4.2.
  
 2.)SEE THE CORRECTION LIST DATED 4/12
 IN REGARDS TO SOME OF THE DOOR PRODUCT
 APPROVAL PRESSURE LIMITATIONS.THIS
 COMMENT WAS ADDRESSED BY AL-FAROOQ FOR
 THE WINDOWS, BUT HAS NOT BEEN ADDRESSED
 FOR THE FOLLOWING ITEMS:
  
 STEELCRAFT L18 4 3070 FG DOOR -
 TEST REPORT FROM CERTIFIED TESTING
 LABORATORIES PROVIDES DESIGN PRESSURES
 OF +-50 AND +-60.
  
 STEELCRAFT SERIES L,SL,CE & B NOA
 NUMBER 01-0129.10.THIS DOOR IS
 COMPLIANT ONLY WHERE WATER INFILTRATION
 IS NOT REQUIRED, ZONE 4.
  
 SERIES 800 SERVICE DOOR, NOA
 01-1031.08, +-56; COMPLIANT ONLY FOR
 ZONE 4.
  
 HORTON AUTOMATICS SERIES 2000 AUTO
 SLIDING GLASS DOOR, NOA 02-0221.03,
 +-67, ONLY WHERE WATER INFILTRATION
 IS NOT NEEDED, COMPLIANT FOR ZONE 4
 ONLY.
  
 PLEASE PROVIDE A SCHEDULE OF THE ABOVE,
 INDICATING ZONE LOCATION AND NOTE THAT
 WATER INFILTRATION IS NOT NEEDED
 AS APPLICABLE.
  
 3.)PLEASE RESUBMIT THE POOL ENCLOSURE
 AS A REVISION.BE ADVISED THAT THIS
 MUST BE APPROVED BEFORE COMMENCING
 WORK OR A 4X FEE MAY BE ASSESSED.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 70 Status P Date 2004-07-28 Cont ID  
Sent By shill Date 2004-07-28 Time 16:22 Rev Time 4.00
Received By shill Date 2004-07-28 Time 16:09 Sent To  
Notes
2004-07-28 00:00:00PRODUCT APPROVAL SUBMITTALS & SHOPS
 PREPARED BY AL-FAROOQ CORPORATION
  
 MIAMI WALL SYSTEMS, S/H & FIXED WINDOWS
 ***PROVISO***SUBMIT 3RD COPY
  
 SITE SPECIFICS FOR S/H & FIXED WINDOWS

Review Stop B BUILDING (STRUCTURAL)
Rev No 69 Status P Date 2004-07-28 Cont ID  
Sent By alange Date 2004-07-28 Time 11:27 Rev Time 0.66
Received By alange Date 2004-07-28 Time 11:27 Sent To  
Notes
2004-07-28 00:00:00SHOPS/CALS FOR GRAND STAIR OK
 PER SH

Review Stop B BUILDING (STRUCTURAL)
Rev No 68 Status P Date 2004-07-28 Cont ID  
Sent By shill Date 2004-07-28 Time 10:16 Rev Time 0.50
Received By shill Date 2004-07-28 Time 10:16 Sent To  
Notes
2004-07-28 00:00:00RFI 556

Review Stop B BUILDING (STRUCTURAL)
Rev No 67 Status P Date 2004-07-28 Cont ID  
Sent By alange Date 2004-07-28 Time 09:21 Rev Time 0.33
Received By alange Date 2004-07-28 Time 09:21 Sent To  
Notes
2004-07-28 00:00:00RFI'S SUBMITTED AND OK #S 553,551,548
 546R, 546, 542R OK PER SH

Review Stop B BUILDING (STRUCTURAL)
Rev No 66 Status F Date 2004-07-27 Cont ID  
Sent By shill Date 2004-07-27 Time 16:45 Rev Time 0.50
Received By shill Date 2004-07-27 Time 16:45 Sent To  
Notes
2004-07-27 00:00:00****CORRECTIONS****
 SIDEWALK CONCRETE MIX & DESIGN SPECS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PLEASE HAVE THIS SUBMITTAL
 REVIEWED BY THE DOR.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 65 Status P Date 2004-07-27 Cont ID  
Sent By shill Date 2004-07-27 Time 16:34 Rev Time 0.50
Received By shill Date 2004-07-27 Time 16:34 Sent To  
Notes
2004-07-27 00:00:00SECTION DETAIL AT DONOR WALL, PREPARED
 BY PERKINS EASTMAN SD-191 & SD191A
 DATED 7/8/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 64 Status P Date 2004-07-27 Cont ID  
Sent By alange Date 2004-07-27 Time 15:47 Rev Time 0.25
Received By alange Date 2004-07-27 Time 15:47 Sent To  
Notes
2004-07-27 00:00:00SIGN LOCATION PAGES AND REVISED
 COURTYARD LANDSCAPE PLAN AND PLANT LIST
 OK PER SH

Review Stop B BUILDING (STRUCTURAL)
Rev No 63 Status P Date 2004-07-20 Cont ID  
Sent By csiegber Date 2004-07-26 Time 14:56 Rev Time 0.50
Received By shill Date 2004-07-20 Time 09:27 Sent To  
Notes
2004-07-20 00:00:00ARCH DETAIL PREPARED BY FRANK
 BENNARDO, PE
  
 RAILING @ C160 SHOPS

Review Stop B BUILDING (STRUCTURAL)
Rev No 62 Status P Date 2004-07-19 Cont ID  
Sent By shill Date 2004-07-19 Time 12:47 Rev Time 0.50
Received By shill Date 2004-07-19 Time 12:47 Sent To  
Notes
2004-07-19 00:00:00CORRECTED METAL SHOPS & DRAWINGS
 FOR VERANDAS AND HIGH ROOFS, PREPARED
 BY TS CHEHAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 61 Status F Date 2004-07-19 Cont ID  
Sent By shill Date 2004-07-19 Time 09:56 Rev Time 0.50
Received By shill Date 2004-07-19 Time 09:56 Sent To  
Notes
2004-07-19 00:00:00****CORRECTIONS****
 SHOPS/CALCS FOR GRAND STAIR
 PREPARED BY A.MARK SCALA, PE
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)INITIALS NOT ACCEPTABLE PER FBPE;
 ALSO INITIALS ARE SIGNIFICANTLY
 DIFFERENT FROM THE SIGNATURE THAT
 APPEARS ON OTHER PAGES FROM THIS
 ENGINEER.
  
 PER CONVERSATION W/ENGINEER, HE IS TO
 MAIL ORIGINAL SIGNED SEALED CALCS.
 ON SMH DESK PENDING RECEIPT.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 60 Status F Date 2004-07-19 Cont ID  
Sent By shill Date 2004-07-16 Time 18:25 Rev Time 0.50
Received By shill Date 2004-07-16 Time 18:25 Sent To  
Notes
2004-07-16 00:00:00****CORRECTIONS****
 FRAMING SHOPS & CALCS FOR "BROW' @
 HIGH ROOF
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE SEAL IS ILLEGIBLE, THE
 SIGNATURE IS A PHOTOCOPY, THE CA NUMBER
 IS NOT ON THE PAGE.SEE THE
 REQUIREMENTS OF YOUR BOARD RULES
 FAC61G15-23.002.PLEASE DO NOT SUBMIT
 PAPERWORK WHICH IS NOT IN COMPLIANCE
 OR A COMPLAINT WILL BE FILED.THIS
 CORRECTION HAS BEEN MADE BEFORE.A
 COPY HAS BEEN RETAINED BY THIS OFFICE
 TO BE TURNED IN TO FBPE.
  
  
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 59 Status P Date 2004-07-16 Cont ID  
Sent By shill Date 2004-07-16 Time 18:22 Rev Time 0.50
Received By shill Date 2004-07-16 Time 18:22 Sent To  
Notes
2004-07-16 00:00:00ELEVATED PLANTER SHOPS

Review Stop B BUILDING (STRUCTURAL)
Rev No 58 Status F Date 2004-07-15 Cont ID  
Sent By csiegber Date 2004-07-16 Time 14:41 Rev Time 0.50
Received By shill Date 2004-07-15 Time 08:51 Sent To  
Notes
2004-07-15 00:00:00****CORRECTIONS****
 RFI476R (AHU STANDS)
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)DOCUMENTS SUBMITTED FOR PUBLIC
 RECORD BY AN ENGINEER ARE TO ORIGINAL
 SIGNED, SEALED AND DATED FAC61G15-23.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 57 Status F Date 2004-06-17 Cont ID  
Sent By csiegber Date 2004-07-07 Time 15:42 Rev Time 0.25
Received By shill Date 2004-06-17 Time 10:42 Sent To  
Notes
2004-06-17 00:00:00****CORRECTIONS****
 HORTON AUTO ENTRANCE SHOPS/NOA
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PLEASE HAVE THE SUBMITTALS
 REVIEWED BY THE ENGINEER.
  
 2.)THE DOORS (LIMIT OF +67/-67) MEET
 THE DESIGN PRESSURES FOR ZONE 4 BUT NOT
 FOR ZONE 5.WHICH ZONE WILL THESE
 DOORS BE INSTALLED IN?
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 56 Status P Date 2004-06-15 Cont ID  
Sent By shill Date 2004-06-15 Time 17:31 Rev Time 0.25
Received By shill Date 2004-06-15 Time 17:31 Sent To  
Notes
2004-06-15 00:00:00SK 43

Review Stop B BUILDING (STRUCTURAL)
Rev No 55 Status F Date 2004-06-15 Cont ID  
Sent By shill Date 2004-06-15 Time 09:35 Rev Time 0.50
Received By shill Date 2004-06-15 Time 09:35 Sent To  
Notes
2004-06-15 00:00:00****CORRECTIONS****
 STEEL CALCS & SHOPS, TRUSSES
  
 1.)THE SHOP DRAWINGS ARE STAMPED BUT
 NOT SIGNED BY THE DESIGNER OF RECORD.
 ADDRESS AND RESUBMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 54 Status F Date 2004-06-15 Cont ID  
Sent By shill Date 2004-06-14 Time 14:38 Rev Time 1.00
Received By shill Date 2004-06-14 Time 14:38 Sent To  
Notes
2004-06-14 00:00:00****CORRECTIONS****
 MORSE CALCULATIONS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)ALL COPIES ARE REQUIRED TO BE
 SIGNED, SEALED AND DATED FAC61G15-23.002
 PLEASE SUBMIT ORIGINALS,NOT PHOTOCOPIES.
  
 2.)VARIOUS CALCS WERE GIVEN.IT
 APPEARS THAT THREE DIFFERENT ISSUES
 ARE BEING ADDRESSED.PLEASE INDICATE
 WHAT THE CALCS ARE FOR, REFERRING BACK
 TO THE PLAN (SHOW THE LOCATION USING
 SHEET NUMBERS AND GRIDLINES).
  
 3.)STRESS INCREASE FOR STEEL IS NOT
 PERMITTED PER FBC1609.4.3(2) WITH LOAD
 COMBINATIONS OF 1609.4.1 OR 1609.4.2.
 PLEASE PROVIDE CLARIFICATION FOR USING
 THE STRESS INCREASE (SHEATHING, PIPE
 CALCS).
  
 4.)IT IS NOT CLEAR HOW YOU HAVE
 ARRIVED AT THE 170 PSF DESIGN (125, 20,
 20 = 165) FOR THE HOT WATER TANK, PLEASE
 CLARIFY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 53 Status P Date 2004-06-15 Cont ID  
Sent By shill Date 2004-06-14 Time 13:23 Rev Time 1.00
Received By shill Date 2004-06-14 Time 13:23 Sent To  
Notes
2004-06-15 00:00:00STEEL SHOPS, POOL MECH MEZZ
2004-06-14 00:00:00SUBMITTALS
  
 VERTICAL EXPANSION JOINTS
 LETTER (ONE COPY ONLY) RE: DRYWALL
 SK-49, WEST LOBBY

Review Stop B BUILDING (STRUCTURAL)
Rev No 52 Status F Date 2004-06-09 Cont ID  
Sent By csiegber Date 2004-06-11 Time 09:08 Rev Time 0.50
Received By shill Date 2004-06-09 Time 11:06 Sent To  
Notes
2004-06-09 00:00:00****CORRECTIONS****
 RFI 523
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)AS PER CONVERSATION WITH CONTRACTOR
 WIRE LATH SHOULD BE INCLUDED IN THIS
 DETAIL.REVISE, SIGN AND SEAL.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 51 Status P Date 2004-06-09 Cont ID  
Sent By shill Date 2004-06-08 Time 14:00 Rev Time 0.50
Received By shill Date 2004-06-08 Time 14:00 Sent To  
Notes
2004-06-08 00:00:00RFI 539

Review Stop B BUILDING (STRUCTURAL)
Rev No 50 Status F Date 2004-06-08 Cont ID  
Sent By shill Date 2004-06-08 Time 13:38 Rev Time 0.50
Received By shill Date 2004-06-08 Time 13:38 Sent To  
Notes
2004-06-08 00:00:00****CORRECTIONS****
 RAILING @ C160 SHOPS
  
 1.)HAVE THE SHOP DRAWINGS REVIEWED BY
 THE DESIGNER OF RECORD.
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 49 Status F Date 2004-05-17 Cont ID  
Sent By csiegber Date 2004-06-08 Time 09:16 Rev Time 0.50
Received By shill Date 2004-05-17 Time 15:31 Sent To  
Notes
2004-05-17 00:00:00****CORRECTIONS****
 ELEVATED PLANTER SHOPS
 PREPARED BY F. BENNARDO, PE
  
 WEST AL ROOF FRAMING & HIGH ROOF BRACKET
 SHOPS & CALCS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PLEASE CORRECT AS NOTED BY
 SLIDER ENGINEERING AND RESUBMIT.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 48 Status P Date 2004-05-17 Cont ID  
Sent By shill Date 2004-05-17 Time 11:14 Rev Time 0.50
Received By shill Date 2004-05-17 Time 11:14 Sent To  
Notes
2004-05-17 00:00:00VARIOUS SUBMITTALS
  
 RFIS - 407, 420, 424, 425, 426, 435, 438
 455, 459, 361, 506, 518, 438, 515, 508,
 SKM-16
  
 SK 48R
  
 BONDING AGENT FOR MASONRY REPAIR SPECS

Review Stop B BUILDING (STRUCTURAL)
Rev No 47 Status F Date 2004-05-14 Cont ID  
Sent By shill Date 2004-05-14 Time 15:31 Rev Time 0.50
Received By shill Date 2004-05-14 Time 15:31 Sent To  
Notes
2004-05-14 00:00:00****CORRECTIONS****
 SUBMITTALS - STOREFRONT DOOR SHOPS,
 ROLLUP DOORS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 SUBMIT WITH THE PRODUCT APPROVALS
 (BINDERS) PREVIOUSLY SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 46 Status P Date 2004-05-14 Cont ID  
Sent By shill Date 2004-05-14 Time 14:27 Rev Time 0.50
Received By shill Date 2004-05-14 Time 14:27 Sent To  
Notes
2004-05-14 00:00:00SUBMITTALS
  
 STEEL PAN STAIRS, PREPARED BY A. MARK
 SCALA, PEDATED 1/30/04
  
 SPRAY FIREPROOFING DATA

Review Stop B BUILDING (STRUCTURAL)
Rev No 45 Status P Date 2004-05-04 Cont ID  
Sent By csiegber Date 2004-05-13 Time 08:43 Rev Time 0.50
Received By shill Date 2004-05-04 Time 17:12 Sent To  
Notes
2004-05-04 00:00:00STEEL STAIR SHOPS AND CALCS
 STAIRS C & D, PREPARED BY MARK SCALA PE

Review Stop B BUILDING (STRUCTURAL)
Rev No 44 Status F Date 2004-04-27 Cont ID  
Sent By shill Date 2004-04-27 Time 08:58 Rev Time 1.00
Received By shill Date 2004-04-27 Time 08:58 Sent To  
Notes
2004-04-27 00:00:00****CORRECTIONS****
 TRUSS CONNECTOR SUBMITTAL
 PREPARED BY TS CHEHAL, PE
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SUBMITTALS ARE TO BE REVIEWED BY
 THE DESIGNER OF RECORD.
  
 2.)THE DETAILS, WITH THE EXCEPTION
 OF SCCW1, HAVE ALREADY BEEN SUBMITTED.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 43 Status P Date 2004-04-27 Cont ID  
Sent By shill Date 2004-04-26 Time 17:18 Rev Time 1.00
Received By shill Date 2004-04-26 Time 17:18 Sent To  
Notes
2004-04-26 00:00:00DETAILS PREPARED BY SLIDER ENGINEERING
  
 SK46, REPAIR @ MECH MEZZANINE
 SK45, REPAIR AT LOADING DOCK
 SK47, ROOF FRAMING/BEAM AT SOUND RM
 C-160, RFI 508
  
 TRUSS ENGINEERING, CONNECTORS PREPARED
 BY TS CHEHAL, PE; SHEETSSCSL1, SCCL7,
 SCCL6R

Review Stop B BUILDING (STRUCTURAL)
Rev No 42 Status P Date 2004-04-21 Cont ID  
Sent By csiegber Date 2004-04-26 Time 11:33 Rev Time 0.50
Received By shill Date 2004-04-21 Time 14:30 Sent To Z
Notes
2004-04-21 00:00:00SIGN SHOPS

Review Stop B BUILDING (STRUCTURAL)
Rev No 41 Status P Date 2004-04-15 Cont ID  
Sent By csiegber Date 2004-04-20 Time 15:56 Rev Time 0.50
Received By shill Date 2004-04-15 Time 16:37 Sent To  
Notes
2004-04-15 00:00:00SURVEY PREPARED BY R KEENER 3/19/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 40 Status F Date 2004-04-13 Cont ID  
Sent By shill Date 2004-04-13 Time 08:47 Rev Time 1.00
Received By shill Date 2004-04-13 Time 08:47 Sent To  
Notes
2004-04-13 00:00:00****CORRECTIONS****
 STEEL TRUSS, MECH RM STAIR,
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 **************************************
 STEEL TRUSS ENGINEERING PREPARED BY
 KEYMARK ENGINEERING, TS CHEHAL PE DATED
 2/25/04, WESTERN AL ROOF SHOPS
 SUBMITTAL #05D-07-05210-1
  
 1.)THE AUTHORIZATION NUMBER FOR
 KEYMARK IS TO BE ON EACH SHEET.THE
 PRINTED NAME AND LICENSE NUMBER OF THE
 PERSON SEALING THE PLAN IS TO BE ON
 EACH SHEET.FAC61G15-23.002.
 ***************************************
  
 ROOF TOP MECH ROOM STAIR, PREPARED BY
 A.MARK SCALA, PE DATED 2/6/04
 SUBMITTAL 05A-20-05500-0
  
 1.)THE TITLE BLOCK IS TO BE ON EACH
 SHEET, AND IS TO INCLUDE THE ADDRESS,
 COMPANY NAME, CA NUMBER.
 THE PRINTED NAME AND LICENSE NUMBER OF
 THE PERSON SEALING THE DOCUMENT IS TO
 BE ON EACH SHEET.
  
 2.)PROVIDE CALCS FOR THE HANDRAIL TO
 COMPLY WITH FBC1608.2.1.PROVIDE CALCS
 FOR THE GUARDRAIL/STAIRRAIL TO COMPLY
 WITH FBC1608.2.2.
  
 **************************************
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 39 Status F Date 2004-04-12 Cont ID  
Sent By shill Date 2004-04-12 Time 10:56 Rev Time 1.00
Received By shill Date 2004-04-12 Time 10:56 Sent To  
Notes
2004-04-12 00:00:00****CORRECTIONS****
 WINDOW/SGD SHOPS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 THE NEGATIVE DESIGN PRESSURES FOR ZONE 5
 EXCEED THE PRODUCT LIMITATIONS.ARE ALL
 OF THE SGDS AND WINDOWS IN ZONE 4?
 EITHER PROVIDE A LETTER OR REVISE AS
 NECESSARY.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 38 Status P Date 2004-04-12 Cont ID  
Sent By shill Date 2004-04-12 Time 10:21 Rev Time 2.00
Received By shill Date 2004-04-12 Time 10:21 Sent To  
Notes
2004-04-12 00:00:00VARIOUS SUBMITTALS
 RFI 377
 RFI 309, STAIR FIX - PROVISO, SUBMIT
 SEALED CALCS
 STRESS LOGS RFI 396, 395, 394

Review Stop B BUILDING (STRUCTURAL)
Rev No 37 Status F Date 2004-03-30 Cont ID  
Sent By alange Date 2004-03-30 Time 14:40 Rev Time 1.00
Received By shill Date 2004-03-30 Time 10:43 Sent To  
Notes
2004-03-30 00:00:00****CORRECTIONS****
 FRAMING AT GATEHOUSE, PTE INSP. LETTERS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 RE: FRAMING AT GATEHOUSE
 NALYWAJKO & ASSOCIATES INC. HAS
 A STATUS OF ARCHIVE WITH FBPE.A
 CURRENT CERTIFICATE OF AUTHORIZATION
 IS REQUIRED TO PRACTICE ENGINEERING IN
 FLORIDA.
  
 RE: PTE INSPECTION LETTERS
 SEE THE CORRECTION LIST DATED 2/24/04.
 THE SAME COMMENT STILL APPLIES:
 PLEASE CLARIFY; THE PERSON WHO SIGNED
 THE LETTER FROM PTE IS NOTED AS
 "PROJECT ENGINEER".DOCUMENTS SUBMITTED
 FOR PUBLIC RECORD FROM ENGINEERS ARE
 TO BE SIGNED AND SEALED WITH INFORMATION
 AS PER FAC61G15-23.002.I WAS UNABLE
 TO OBTAIN ANGELO DA SILVA'S ENGINEERING
 LICENSE NUMBER FROM FBPE.
  
 THE PRINTED NAME AND LICENSE NUMBER OF
 THE PERSONE SEALING THE DOCUMENT IS TO
 BE ON EACH SHEET, FAC61G15-23.002.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 36 Status P Date 2004-03-30 Cont ID  
Sent By shill Date 2004-03-30 Time 10:39 Rev Time 0.50
Received By shill Date 2004-03-30 Time 10:39 Sent To  
Notes
2004-03-30 00:00:00VARIOUS SUBMITTALS
  
 SIMPSON CONNECTOR
  
 RETAINING WALL AT DINING ROOM PATIO
 DETAIL PREPARED BY MIKE SCHORAH, PE
 DATED 2/23/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 35 Status F Date 2004-03-25 Cont ID  
Sent By shill Date 2004-03-25 Time 08:38 Rev Time 0.50
Received By shill Date 2004-03-25 Time 08:38 Sent To  
Notes
2004-03-25 00:00:00****CORRECTIONS****
 WINDOW PRODUCT DATA AND CALCULATIONS
 WINDOW SHOP DRAWINGS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 AS PER CONVERSATION WITH CONTRACTOR,
 ENGINEER IS TO PROVIDE DESIGN PRESSURES
 FOR WINDOWS AND DOORS.RESUBMIT WITH
 THAT INFORMATION.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 34 Status P Date 2004-03-24 Cont ID  
Sent By shill Date 2004-03-24 Time 14:07 Rev Time 2.00
Received By shill Date 2004-03-24 Time 14:07 Sent To  
Notes
2004-03-24 00:00:00RFIS PREPARED BY PAUL KING, PE
  
 RFI 420, 427, 436, 454,
  
 SK30, SK31, SK32
  
 2 HR SHAFT WALL SUBMITTAL (ICBO 3579)

Review Stop B BUILDING (STRUCTURAL)
Rev No 33 Status F Date 2004-03-24 Cont ID  
Sent By shill Date 2004-03-23 Time 16:12 Rev Time 1.00
Received By shill Date 2004-03-23 Time 16:12 Sent To  
Notes
2004-03-23 00:00:00****CORRECTIONS****
 FRAMING AT AL ROOF, MECH RM 1/30/04
 FRAMING AT HIGH ROOFS, 1/7/04
 PREPARED BY M.NALYWAJKO, PE
  
 PLEASE RESUBMIT WITH AN ORIGINAL
 SIGNATURE AND LEGIBLE SEAL.THE
 AUTHORIZATION NUMBER OF NALYWAJKO &
 ASSOICATES, INC. HAS A STATUS OF
 "ARCHIVE".A CURRENT ENGINEERING
 LICENSE IS REQUIRED TO PRACTICE
 ENGINEERING IN FLORIDA.SEE
 WWW.FBPE.ORG FOR MORE INFORMATION.
 FAC61G15.
  
 IF AN ENGINEERING COMPANY IS ON A
 DOCUMENT, THE AUTHORIZATION NUMBER FOR
 THAT COMPANY MUST BE ON EACH SHEET.
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 32 Status F Date 2004-04-12 Cont ID  
Sent By shill Date 2004-03-23 Time 12:46 Rev Time 3.00
Received By shill Date 2004-03-23 Time 12:46 Sent To  
Notes
2004-04-12 00:00:00PRODUCT APPROVAL SUBMITTAL
 ***CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE NOA IS NO LONGER IN THE
 PACKAGE THAT WAS PREVIOUSLY SUBMITTED
 FOR THE MECHANICAL ROOF.ARE YOU USING
 THE GUTTER ROOF PRODUCT AT THE
 MECHANICAL ROOF?IT IS MARKED GUTTER
 ROOF.
  
 2.)A REQUEST WAS MADE FOR THE ORIGINAL
 SIGNED AND SEALED COVER LETTER AND TEST
 REPORT, SEE PREVIOUS LIST #3.THIS
 IS NO LONGER IN THE PACKAGE, ONLY
 PRODUCT DATA.
  
 3.)REGARDING SERIES 35H (MD)
 STOREFRONT DOOR, STEELCRAFT DOORS,
 SERIES 800 SERVICE DOOR, SERIES 2000 SGD
 THE ZONE 5 PRESSURES EXCEED PRODUCT
 LIMITATIONS.ARE THESE TO BE INSTALLED
 IN ZONE 4 ONLY?WHAT WILL BE USED IN
 ZONE 5?
  
 4.)THE STEELCRAFT DOOR IS TO BE
 TESTED TO ASTM E330-84, FBC35.PROVIDE
 A SITE SPECIFIC OR SUBMIT A TEST REPORT
 THAT COMPLIES WITH FBC.ALSO SEE
 PREVIOUS NOTE IN REGARDS TO THE
 PRESSURES.
  
 CC:DON NEELY
2004-03-23 00:00:00****CORRECTIONS****
 PRODUCT APPROVAL SUBMITTAL
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)NOA 030421.04, SIX STORY GUTTER
 ROOFS - MAX DESIGN PRESSURE IS 97.5,
 DESIGN PRESSURE FOR SIX STORY ROOF
 IS 146.2.SEE GENERAL LIMITATION #9.
  
 2.)NOA 030212.06, THREE STORY
 MECHANICAL ROOF - MAX DESIGN PRESSURE IS
 -75, DESIGN PRESSURE FOR THREE STORY IN
 ZONE 2 IS 88.3.ENHANCED FASTENING,
 RATIONAL ANALYSIS OR EXTRAPOLATION
 IS TO BE DONE BY THE DESIGNER OF
 RECORD.SEE GENERAL LIMITATION #7.
  
 3.)JOHNS MANVILLE MODIFIED BITUMEN
 TEST REPORT - SUPPLY AN ORIGINAL
 SIGNED AND SEALED COVER LETTER FROM
 ATLANTIC CARRIBEAN. (FOR ONE AND THREE
 STORY ROOFS)
  
 THE FOLLOWING ROOF PRODUCT APPROVAL
 SUBMITTALS ARE APPROVED CONDITIONALLY
 SUBJECT TO REVIEW BY DESIGNERS OF
 RECORD AS PER COMMENT ON MODIFIED
 BITUMEN ROOFING SHOP DRAWINGS:
 ULTRAGUARD PVC-LIGHTWEIGHT CONCRETE DE
 BASE SHEET ATTACHMENT CALCS, 1 STORY
 BASE SHEET ATTACHMENT CALCS, 3 STORY
 ALTUSA S
 POLYFOAM
 TILE SPECS, SYSTEM B
 TILE UNDERLAYMENT FASTENER SPACING
 TILE ATTACHMENT CALCS
  
 4.)AS PER CONVERSATION WITH BOB
 LUTHER, WINDOW DESIGN PRESSURES WERE
 NOT ON THE PLAN AND WERE PROVIDED AS
 A SEPARATE SUBMITTAL.PROVIDE A COPY
 FROM THE ENGINEER SO THAT THE OTHER
 PRODUCTS SUBMITTED CAN BE REVIEWED.
  
  
 ROOF SUBMITTAL #07A-05-07552-0
 SIX STORY MODIFIED ROOF DATA
  
 ROOF SUBMITTAL #07A-04-07522-0
 1 & 3 STORY MODIFIED ROOF DATA
  
 PLEASE RESUBMIT AFTER APPROVAL OF
 SYSTEM (TEST REPORTS) BY DESIGNER OF
 RECORD.
  
  
  
  
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 31 Status P Date 2004-03-23 Cont ID  
Sent By shill Date 2004-03-23 Time 11:50 Rev Time 0.00
Received By shill Date 2005-01-20 Time 16:18 Sent To  
Notes
2004-03-23 00:00:00ALUM BALCONY RAIL SHOPS AND CALCS
 PREPARED BY A.MARK SCALA, PE
 12/9/03
  
 ROOF DATA/NOA FOR ALTUSA S ROOF TILE

Review Stop B BUILDING (STRUCTURAL)
Rev No 30 Status F Date 2004-03-13 Cont ID  
Sent By csiegber Date 2004-03-17 Time 15:57 Rev Time 0.50
Received By shill Date 2004-03-13 Time 10:07 Sent To  
Notes
2004-03-13 00:00:00****CORRECTIONS****
 OCTAGON ROOF FRAMING DETAILS PREPARED BY
 MICHAEL NALYWAJKO, PE1/29/04
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)AN ORIGINAL SIGNATURE AND DATE IS
 REQUIRED ON EACH SHEET.THE SEAL IS
 ILLEGIBLE.THE AUTHORIZATION NUMBER
 FOR NALYWAJKO & ASSOCIATES INC. IS TO
 BE ON EACH SHEET. FAC61G15-23.002
  
 2.)SEE SHEET 8 OF 10; DESIGNER OF
 RECORD HAS REDLINED THE NOTE IN
 REGARDS TO RESPONSIBILITY FOR THE
 DESIGN.REMOVE THE NOTE FROM THE
 SHEET.

Review Stop B BUILDING (STRUCTURAL)
Rev No 29 Status F Date 2004-03-13 Cont ID  
Sent By shill Date 2004-03-13 Time 10:00 Rev Time 0.50
Received By shill Date 2004-03-13 Time 10:00 Sent To  
Notes
2004-03-13 00:00:00****CORRECTIONS****
 TRUSS CONNECTION DETAILS PREPARED BY
 T.S. CHEHAL, PE DATED 9/18/03
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
  
 1.)SIGNATURE IS TO BE AN ORIGINAL
 SIGNATURE, NOT A COPY.EACH SHEET IS
 TO BE SEALED.EACH SHEET IS TO CONTAIN
 THE NAME, LICENSE NUMBER AND ADDRESS
 OF THE ENGINEER. FAC61G15-23.002.

Review Stop B BUILDING (STRUCTURAL)
Rev No 28 Status P Date 2004-03-13 Cont ID  
Sent By shill Date 2004-03-13 Time 09:46 Rev Time 1.00
Received By shill Date 2004-03-13 Time 09:45 Sent To  
Notes
2004-03-13 00:00:00RFI 386
 RFI 399
 RFI 381
 SHEATHING TO DECKING CONNECTOR DATA
 (BUGLE HEAD STREAKER)

Review Stop B BUILDING (STRUCTURAL)
Rev No 27 Status P Date 2004-03-04 Cont ID  
Sent By csiegber Date 2004-03-05 Time 15:42 Rev Time 2.00
Received By shill Date 2004-03-04 Time 07:41 Sent To  
Notes
2004-03-04 00:00:00CABINET SHOPS, EDWARD DON & CO
 GROUT PRODUCT DATA, CHEMMASTERS PAC
 METAL DECKING
 GUARDHOUSE WINDOW TEST REPORT,SHOPS &
 CALCS

Review Stop B BUILDING (STRUCTURAL)
Rev No 26 Status P Date 2004-03-03 Cont ID  
Sent By shill Date 2004-03-03 Time 12:12 Rev Time 0.50
Received By shill Date 2004-03-03 Time 12:12 Sent To  
Notes
2004-03-03 00:00:00RFI263, SKETCH 18R - PROVISO - SUBMIT AS
 REVISION
  
 KITCHEN & BATH SHOPS, SACO INDUSTRIES

Review Stop B BUILDING (STRUCTURAL)
Rev No 25 Status F Date 2004-03-03 Cont ID  
Sent By shill Date 2004-03-03 Time 12:10 Rev Time 0.50
Received By shill Date 2004-03-03 Time 12:09 Sent To  
Notes
2004-03-03 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 RFI 374
 MY UNDERSTANDING IS THAT ZONE 3
 PRESSURES WERE USED FOR BOTH ZONE 2 AND
 ZONE 3.PLEASE HAVE THE ENGINEER
 CONFIRM.
  
 THE PRINTED NAME AND LICENSE NUMBER OF
 THE PERSON SEALING THE DOCUMENT IS TO
 BE ON EACH SHEET, FAC61G-23.002.
  
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 24 Status P Date 2004-03-02 Cont ID  
Sent By csiegber Date 2004-03-03 Time 10:25 Rev Time 0.50
Received By shill Date 2004-03-02 Time 15:07 Sent To  
Notes
2004-03-02 00:00:00DINING ROOM DETAILS PREPARED BY
 PALM BEACH TRIM 12/4/03
 FAMILY ROOM DETAILS, 11/19/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 23 Status P Date 2004-03-02 Cont ID  
Sent By shill Date 2004-03-02 Time 05:29 Rev Time 1.00
Received By shill Date 2004-03-02 Time 05:29 Sent To  
Notes
2004-03-02 00:00:00GIFT SHOP, RECEPTION TRIM/CABINETS
 PREPARED BY PALM BEACH TRIM 11/8/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 22 Status P Date 2004-04-12 Cont ID  
Sent By csiegber Date 2004-02-27 Time 14:04 Rev Time 2.00
Received By shill Date 2004-02-24 Time 15:35 Sent To  
Notes
2004-04-12 00:00:00STRESSING LOGS, RFIS 409, 448, 418, 410
 415
2004-02-24 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 RFIS 395, 396, 394; STRESS LOG REVIEWS
 ROOF PHASE 2, 3RD FLOOR RL BLDG,
 2ND FL AL PHASE 3 & 4.
  
 1.)PLEASE CLARFIY; THE PERSON WHO
 SIGNED THE LETTER FROM PTE IS NOTED AS
 "PROJECT ENGINEER".DOCUMENTS SUBMITTED
 FOR PUBLIC RECORD FROM ENGINEERS ARE
 TO BE SIGNED AND SEALED WITH INFORMATION
 AS PER FAC61G15-23.002.I WAS UNABLE
 TO OBTAIN ANGELO DA SILVA'S ENGINEERING
 LICENSE NUMBER FROM FBPE.
  
 2.)THE PRINTED NAME AND LICENSE
 NUMBER OF THE PERSON SEALING THE
 DOCUMENT IS TO BE ON EACH SHEET,
 FAC61G15-23.002.
  
  
 COMMENT # 2 APPLIES TO ALL SUBMITTALS
  
 RFI 377THE MECHANICAL SKETCH REQUESTED
 WAS PROVIDED BUT STILL NEEDS APPROVAL
 FROM THE MECHANICAL ENGINEER.
  
 RFI 309A PHOTOCOPY OF THE LETTER FROM
 HEAVY IRON'S PE WAS SUBMITTED; AN
 ORIGINAL SIGNED, SEALED LETTER REVIEWED
 BY THE DESIGNER OF RECORD IS REQUIRED
 FAC61G.
  
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 21 Status F Date 2004-02-20 Cont ID  
Sent By shill Date 2004-02-20 Time 11:12 Rev Time 2.00
Received By shill Date 2004-02-20 Time 11:11 Sent To  
Notes
2004-02-20 00:00:00****CORRECTIONS****
  
 SUBMITTALS/RFIS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 THE FOLLOWING CORRECTION APPLIES TO ALL
 RFIS - THE PRINTED NAME AND LICENSE
 NUMBER OF THE PERSON SEALING THE PLAN
 IS TO BE ON EACH SHEET, FAC61G15-23.002.
  
  
 RFI 260 - SUBMIT AN ORIGINAL SEALED
 REPAIR DETAIL, FAC61G15-23.002 (DETAIL
 PROVIDED BY M.A. HAMID, PE) DATED 12/4/4
  
 RFI 386, 399, 382, 381 - ANY CHANGES TO
 THE PLAN ARE TO BE SUBMITTED AS
 REVISIONS, NOT SUBMITTALS.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 20 Status F Date 2004-02-18 Cont ID  
Sent By shill Date 2004-02-18 Time 16:16 Rev Time 2.00
Received By shill Date 2004-02-18 Time 16:16 Sent To  
Notes
2004-02-18 00:00:00***CORRECTIONS***
  
 SUBMITTALS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724

Review Stop B BUILDING (STRUCTURAL)
Rev No 19 Status P Date 2004-02-18 Cont ID  
Sent By shill Date 2004-02-18 Time 08:21 Rev Time 0.50
Received By shill Date 2004-02-18 Time 08:21 Sent To  
Notes
2004-02-18 00:00:00RFI 311 PREPARED BY PAUL KING 1/19/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 18 Status F Date 2004-01-30 Cont ID  
Sent By csiegber Date 2004-02-13 Time 16:34 Rev Time 4.00
Received By shill Date 2004-01-30 Time 11:14 Sent To  
Notes
2004-01-30 00:00:00*****CORRECTIONS******
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 PRODUCT APPROVALS, ORIGINAL SUBMITTAL
  
 HAVE ALL PRODUCT APPROVALS REVIEWED BY
 THE DESIGNER OF RECORD.SUBMIT THREE
 PACKAGES CONTAINING COMPLETE LEGIBLE
 PRODUCT APPROVALS.APPROVED AS NOTED:
  
 MILESTONE ALUMINUM WINDOWS 9964A
 SINGLE HUNG
 FIXED
 SUBMIT ONLY SBCCI REPORT AS THE TEST
 REPORT PREPARED BY NATIONAL CERTIFIED
 TESTING LABORATORIES DOES NOT USE THE
 SAME STANDARD AS FBC35 (ASTM E330-84).
 VERIFY THAT THE REPORT 9964A IS CURRENT
 (EFFECTIVE PERMIT SUBMITTAL DATE).
  
 ALTUSA S CLAY ROOF TILE
  
 SBS MODIFIED BITUMEN OVER LWC DECKS
  
 SINGLE OUTSWING DOOR -APPROVED FOR AREAS
 COVERED BY A CANOPY OR OVERHANG, SEE
 LIMITATION ON NOA.
  
 DOUBLE OUTSWING STEEL DOOR - NOT
 APPROVED (NOT ON PLAN PER CONTRACTOR)
  
 SUBMIT THE WATER HEATER INFORMATION AS
 A SUBMITTAL FOR PLUMBING REVIEW.
  
 PRODUCT APPROVALS REQUIRED
  
 MODIFIED OVER CONCRETE DECK
 MODIFIED OVER STEEL DECK
 MULLIONS - WINDOWS AND OVER SGD
 SLIDING GLASS DOOR
 TRANSOM OVER SGD
 ARCH ALUMINUM STOREFRONT WINDOW SYSTEM
 HORTON AUTO SLIDING GLASS DOOR
 OVERHEAD DOOR
 ALUMINUM DOORS
 FRENCH DOORS
 ANY OTHER PRODUCTS REQUIRED BUT NOT
 LISTED ABOVE
 IMPACT PROTECTION, IF ANY OF THE ABOVE
 GLAZED ITEMS ARE NOT IMPACT RESISTANT

Review Stop B BUILDING (STRUCTURAL)
Rev No 17 Status P Date 2004-01-29 Cont ID  
Sent By shill Date 2004-01-29 Time 17:56 Rev Time 0.50
Received By shill Date 2004-01-29 Time 17:56 Sent To  
Notes
2004-01-29 00:00:00GRAND STAIR EMBED, STEEL FABRICATORS
  
 FOODSERVICE EQUIPMENT

Review Stop B BUILDING (STRUCTURAL)
Rev No 16 Status F Date 2004-01-26 Cont ID  
Sent By shill Date 2004-01-26 Time 16:25 Rev Time 1.00
Received By shill Date 2004-01-26 Time 16:25 Sent To  
Notes
2004-01-26 00:00:00*****CORRECTIONS*****
 ROOF SUBMITTALS (PVC AND MODIFIED)
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PROVIDE PRODUCT APPROVAL/TEST
 REPORTS.NONE ARE ON FILE FOR THIS JOB.
  
 2.)SEE ATTACHED POLICY REGARDING
 MISSILE IMPACT PROTECTION.AS PER ITEM
 #1, SINCE PRODUCT APPROVALS FOR WINDOWS
 AND IMPACT PROTECTION WERE NOT SUBMITTED
 AS A PART OF THE PRIMARY PERMIT, APPLY
 FOR A SEPARATE PERMIT FOR THESE ITEMS.
  
 3.)SEE ATTACHED POLICY, ITEM #13.IF
 REMOVABLE SHUTTERS ARE USED TO COMPLY
 WITH FBC1606.1.4, SUBMIT AN INSTALLATION
 PLAN FOR HURRICANE PROTECTION.
  
 CC:DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 15 Status P Date 2004-01-26 Cont ID  
Sent By shill Date 2004-01-26 Time 14:51 Rev Time 2.00
Received By shill Date 2004-01-26 Time 14:51 Sent To  
Notes
2004-01-26 00:00:00SUBMITTALS:
  
 FINISH HARDWARE
 DOOR FRAMES DATA/SHOP DRAWINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 14 Status P Date 2004-01-22 Cont ID  
Sent By shill Date 2004-01-22 Time 20:04 Rev Time 0.50
Received By shill Date 2004-01-22 Time 20:04 Sent To  
Notes
2004-01-22 00:00:00STEEL SHOP DRAWINGS - SYNAGOGUE, PORTE
 COCHERE, MEZZANINE - STEEL FABRICATORS,
 10/8/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 13 Status F Date 2004-01-22 Cont ID  
Sent By shill Date 2004-01-22 Time 19:23 Rev Time 2.00
Received By shill Date 2004-01-22 Time 19:23 Sent To  
Notes
2004-01-22 00:00:00****CORRECTIONS****
 ****SUBMITTALS*****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 RFI#377PROVIDE THE SKETCH REFERRED TO,
 APPROVAL FROM MECHANICAL ENGINEER AS
 REQUESTED BY PE.
  
 RFI#309PROVIDE THE ORIGINAL SIGNED AND
 SEALED LETTER FROM HEAVY IRON'S PE,
 REVIEWED BY DESIGNER OF RECORD.
  
 RFI#311PLEASE CLARIFY, WHAT IS 16-35?
  
 RFI#344THE RFI REFERS TO SKETCH
 SK-AI-1.PLEASE PROVIDE, AND SUBMIT
 AS A REVISION.
  
 RFI#374THE ENGINEER IS TO INDICATE
 ZONE 3 AREAS.WHY IS ZONE 2 USED ON
 THE HIGH ROOF?
  
 SK-18RPROVIDE RFI#263 REFERRED TO IN
 THE DETAIL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 12 Status P Date 2004-01-22 Cont ID  
Sent By shill Date 2004-01-22 Time 19:20 Rev Time 0.50
Received By shill Date 2004-01-22 Time 19:20 Sent To  
Notes
2004-01-22 00:00:00SUBMITTAL - RFI RE:PENETRATION OF BEAM
 **PROVISO**SUBMIT DETAIL WHEN AVAILABLE

Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status P Date 2004-01-22 Cont ID  
Sent By shill Date 2004-01-22 Time 18:48 Rev Time 3.00
Received By shill Date 2004-01-22 Time 18:48 Sent To  
Notes
2004-01-22 00:00:00SUBMITTALS - FRY REGLET PRODUCT DATA,
 ROOF OPENING DETAIL, NONSHRINK GROUT,
 BURKE ACRYLIC BONDING AGENT, RFIS

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status P Date 2004-01-21 Cont ID  
Sent By shill Date 2004-01-21 Time 15:52 Rev Time 0.50
Received By shill Date 2004-01-21 Time 15:51 Sent To  
Notes
2004-01-21 00:00:00DINING ROOM TRUSS SHOP DRAWINGS,
 PREPARED BY STEEL FABRICATORS DATED
 12/12/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2004-01-21 Cont ID  
Sent By shill Date 2004-01-21 Time 14:43 Rev Time 0.50
Received By shill Date 2004-01-21 Time 14:43 Sent To  
Notes
2004-01-21 00:00:00SHORING PREPARED BY JAMES E. PAIT, PE
 DATED 6/27/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2004-01-15 Cont ID  
Sent By csiegber Date 2004-01-21 Time 12:27 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2004-01-15 00:00:00ARCHITECTURAL AND STRUCTURAL REVISIONS
 #3 DATED 10/31/03.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2003-12-02 Cont ID  
Sent By csiegber Date 2003-12-23 Time 12:54 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2003-12-02 00:00:00THE PTE FAX LETTER DATED 11/24/03 SIGNED
 BY MIAN A. HAMID, PE REQUIRES AN
 ORIGINAL SIGNATURE AND EMBOSSED SEAL
 WHEN SUBMITTED FOR PUBLIC RECORD.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2003-11-24 Cont ID  
Sent By csiegber Date 2003-11-26 Time 13:51 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2003-11-24 00:00:00JS PLASTERING INC PRODUCT SUBMITTALS.
  
 THE PRODUCTS ARE SUITABLE WITH THE
 EXCEPTION OF THE STO EIFS.PLEASE
 PROVIDE TEST DATA AND ACCEPTANCE
 REPORTS DEMONSTRATING COMPLIANCE WITH
 FBC 1404.1.1 AND FBC 2603.6.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2003-07-28 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:28 Rev Time 2.00
Received By lmartine Date   Time   Sent To  
Notes
2003-07-28 00:00:00APPROVED FOR HAROLD
  
 SEE PROVISO WRITTEN ON PLANS PERTAINING
 TO PRODUCT APPROVALSLM

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2003-07-15 Cont ID  
Sent By hpiskura Date 2003-07-14 Time 15:58 Rev Time 0.00
Received By hpiskura Date 2003-07-14 Time 10:42 Sent To  
Notes
2003-07-14 00:00:00PLEASE SEPARATE THE PLANS INTO SEPARATE
 MANAGEABLE GROUPS.THE LARGE ROLL OF
 LOOSE PAGES IS UNACCEPTABLE. COLLATE
 THE MOST RECENT PLANS PAGES THAT ARE TO
 BE PERMITTED INTO ARCHITECTURAL, MEP,
 AND ANCILLARY AREAS SUCH AS FOOD
 EQUIPMENT, LANDSCAPE, IRRIGATION, ETC.
 ALSO, REVISE THE INDEX PAGE(S) TO
 REFLECT THE DRAWINGS IN THE SET. THREE
 COMPLETE SETS OF ALL PERTINENT
 INFORMATION, SUCH AS PRODUCT APPROVALS,
 TEST REPORTS, ETC. WILL BE NECESSARY.
  
 BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED A THRESHOLD INSPECTION PLAN MUST
 BE PROVIDED TO THE CITY. SEE FBC 105.13
  
 BEFORE A PERMIT MAY BE ISSUED IMPACT
 FEES MUST BE PAID TO THE COUNTY, THE
 PERMIT PLANS STAMPED BY THAT OFFICE AND
 A COPY OF THE PAID RECEIPT ATTACHED TO
 THE PERMIT APPLICATION. CALL
 561-233-5025 FOR MORE INFORMATION.
  
 SHEET S2.19, PLEASE CLARIFY THE
 CONFLICTING COMPONENT AND CLADDING
 PRESSURES WITH THE WINDOWS AND DOORS.
 THE WIND LOAD SCHEDULE HAS A DIFFERENT
 SET OF FIGURES AND CORNER DISTANCE THAN
 WINDOW/DOOR WIND PRESSURE TABLE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-05-20 Cont ID  
Sent By hpiskura Date 2003-05-20 Time 10:40 Rev Time 0.00
Received By hpiskura Date 2003-05-19 Time 14:22 Sent To  
Notes
2003-05-20 00:00:00SHEET 5/S2.17 STILL CALLS OUT PLYWOOD
 SHEATHING ALTHOUGH THE GRAPHIC
 DEPICTION IS NOW METAL DECKING.PLEASE
 REVISE AS NECESSARY.
  
 SHEET S-2.24 CALLS FOR A 8000 PSI
 CONCRETE PUDDLING AT SELECTED COLUMN
 LOCATIONS AS TYPICAL.THESE 8000 PSI
 AREAS DONOT HAVE DIMENSIONS ORA
 DIRECTIONS FOR THE TRANSITION TO THE
 5000 PSI CONCRETE IN THE REMAINDER OF
 THE FLOOR SLAB.PLEASE PROVIDE NOTES
 ON THE PLAN AS NECESSARY.
  
 THE SBCCI REPORT #9964 IS NOT CURRENTLY
 LISTED.PLEASE PROVIDE A CURRENT REPORT
 AND VERIFY THE DESIGN PRESSURES WITH
 THOSE ON THE PLANS.
  
 THE NOA FOR THE ROOF TILES #02-1115.03
 IS LIMITED TO WOOD DECK APPLICATIONS.
 PROVIDE A COMPATIBLE SYSTEM.
  
 PLEASE PROVIDE A THRESHOLD INSPECTION
 PLAN.
  
 THE NOTICE OF COMMENCEMENT PROVIDED HAS
 NOT BEEN RECORDED WITH THE CLERK OF THE
 COURTS.
  
 IMPACT FEES MUST BE PAID TO THE COUNTY
 PRIOR TO PERMIT ISSUE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-03-31 Cont ID  
Sent By hpiskura Date 2003-03-31 Time 10:52 Rev Time 0.00
Received By hpiskura Date 2003-03-26 Time 08:39 Sent To  
Notes
2003-03-31 00:00:00SHEET S2.17 DOES NOT SHOW THE METHOD OF
 ATTACHMENT FOR THE METAL DECKING.
  
 SECTION 5/S2.17 CALLS OUT PLYWOOD ROOF
 SHEATHING WHICH IS NOT PERMITTED IN
 TYPE II CONSTRUCTION.SEE FBC 604.
  
 WHAT ARE THE DIMENSIONS OF THE GROUT
 SLEEVE SHOWN IN SECTION 16/S2.18?
  
 SECTIONS 5/S2.18 AND 16/S2.18, HOW ARE
 THE TRUSSES ATTACHED TO THE BUILDING?
  
 SHEET S 2.19 CALLS OUT EDGE/CORNER
 DISTANCES AS 10' AND 15', PLEASE
 CLARIFY.
  
 BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO THE
 COUNTY, THE PERMIT PLANS STAMPED BY
 THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. CALL 561-233-5025 FOR
 MORE INFORMATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-07-23 Cont ID  
Sent By hpiskura Date 2002-07-23 Time 11:10 Rev Time 0.00
Received By hpiskura Date   Time   Sent To Z
Notes
2002-07-23 00:00:00PAID PLAN REVIEW.THE BUILDING WILL BE
 A THRESHOLD BUILDING AND WILL REQUIRE A
 THRESHOLD INSPECTOR AND A THRESHOLD
 INSPECTION PLAN.SEE FBC 105.13.
 CONTACT DON NEELY, ASSISTANT BUILDING
 OFFICIAL FOR ADDITIONAL INFORMATION
 REGARDING THRESHOLD BUILDINGS.(561)
 659-8096 EXT, 8333.
  
 THE PLANS PROVIDED ARE NOT COMPLETE NOR
 WERE ANY SPECIFICATIONS INCLUDED, THUS
 ACOMPLETE, CLOSE AND CRITICAL PLAN
 REVIEW WAS NOT POSSIBLE.FBC 104.3.1.1
 PROVIDES AN OUTLINE OF THE ITEMS
 REQUIERED FOR PLAN REVIEW AND CAN SERVE
 AS A GUIDE FOR THE BUILDING DESIGN
 PROFESSIONALS.
  
 THE BUILDING PROPOSES A MIXED OCCUPANCY
 GROUP OF R2, R4, B AND A2, USES.THE
 SITE PLAN DOES NOT INDICATE THE
 LOCATION OF THE FUTURE BLDG FOR
 DETERMINATION OF FBC TABLE 600
 REQUIREMENTS. (ASSUMED PROPERTY LINE)
  
 SHEET A101, GENERAL NOTES #12.SEE FBC
 803.2 FOR CLASSIFICATION OF INTERIOR
 FINISH.
  
 NOTES #13 AND #28, RE: FIRE PROTECTION
 AND FIRE STOPPING.SEE FBC 104.2.3 AND
 THE REQUIREMENT FOR SPECIFIC
 INFORMATION AS TO DESIGNS AND METHODS.
  
 SHEET LS- 1.01 HAS ERRONEOUS INFORMATION
 FOR THE RATINGS OF EXTERIOR BEARING
 WALLS.SEE FBC TABLE 600.(3HR)
  
 SIMILAR CONFLICTS EXIST WITH THE
 HEADING"BEAMS, GIRDERS AND ARCHES".
  
 LS - 1.01.AREAS SHOWN AS "B GROUP B"
 AND SUITES A AND B, DECLARE A SINGLE
 EXIT COMPLIANCE BASED ON AREA IN SQUARE
 FEET.SEE ALSO FBC 1004.1.2 AND FBC
 1004.1.3 AS MAY BE APPLICABLE.
  
 SUITES A AND B ARE PRESENTED AS
 "INDIVIDUAL" IT THEN FOLLOWS THAT
 CORRIDOR 134 IS A DEAD END IN EXCESS OF
 FIFTY FEET AND IS PROHIBITTED BY FBC
 1004.1.4.
  
 DOORS SHOWN AS C176, C177 AT THE PRIVATE
 DINING ROOM ARE NOT RATED AS REQUIRED
 FOR ATRIUM SEPARATION.
  
 A PARTITION DETAIL FOR THE NON-RATED
 SMOKE PARTITIONS SHOULD BE PROVIDED IN
 ACCORDANCE WITH FBC TABLE 704.2.4,
 FOOTNOTE #4.
  
 A SEATING PLAN IS NECESSARY FOR THE
 DINING, MULTI USE, AND SIMILAR ROOMS.
 SEE FBC 1003.1.2.
  
 PROVIDE CALCULATIONS FOR THE ATRIUMS,
 AND AN NARRATIVE OF THE OPERATION.
 INCLUDE A DESCIPTION OF COMPLIANCE WITH
 FBC 414.8 FOR THE INTERIOR ROOMS.
  
 FBC TABLE 410.2.2 REQUIRES ONE HOUR
 SEPARATION FOR THE MAINTENANCE ROOM
 #A144.
  
 THE RAMP IN ROOM C157, FOR THE PLATFORM,
 MUST COMPLY WITH FBC 11-4.8, INCLUDING
 HANDRAILS.
  
 THE EIFS TRIM DEPICTED IN VARIOUS
 PLACESDOES NOT COMPLY WITH FBC 1404.1.
  
 THE STRUCTURAL PLANS ARE INCOMPLETE.
 HOW WAS THE 2500 PSF SOIL BEARING VALUE
 ARRIVED AT?
  
 PLEASE NOTE THE DESIGN STANDARDS USED,
 ASSUMED LOADS AND SPECIFIC INFORMATION
 FOE THE DELEGATED DESIGN ITEMS,
 INCLUDING, TRUSSES, HAND GUARD RAILS,
 STAIRS, ETC.
  
 THE ABOVE INFORMATION SHOULD BE
 ADDRESSED IN THE ACTUAL PERMIT PLANS
 AND SPECIFICATIONS.

Review Stop E ELECTRICAL
Rev No 13 Status P Date 2004-11-29 Cont ID  
Sent By dpalmer Date 2004-11-29 Time 14:01 Rev Time 3.00
Received By dpalmer Date 2004-11-29 Time 11:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 12 Status P Date 2004-06-01 Cont ID  
Sent By dpalmer Date 2004-06-01 Time 16:02 Rev Time 0.33
Received By dpalmer Date 2004-06-01 Time 16:02 Sent To  
Notes
2004-06-01 00:00:00SUBMITTAL FOR VARIABLE FREQ DRIVES.
 DATE STAMPED, ONE COPY TO HP.

Review Stop E ELECTRICAL
Rev No 11 Status P Date 2004-04-06 Cont ID  
Sent By alange Date 2004-05-26 Time 09:13 Rev Time 0.50
Received By btrobaug Date 2004-04-06 Time 08:53 Sent To FIRE
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 10 Status P Date 2004-04-01 Cont ID  
Sent By btrobaug Date 2004-04-01 Time 10:46 Rev Time 1.00
Received By btrobaug Date 2004-04-01 Time 10:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 9 Status F Date 2004-01-27 Cont ID  
Sent By alange Date 2004-03-30 Time 13:20 Rev Time 0.33
Received By dpalmer Date 2004-01-27 Time 12:46 Sent To  
Notes
2004-01-27 00:00:00**************** UNSAT *************
  
 PLEASE SEE ATTACHED REVIEW NOTES FROM
 1/2/04.
 MUST BE UNDER SEPRATE PERMIT. PLANS,
 PERMIT APPL, FEES ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 8 Status F Date 2004-01-05 Cont ID  
Sent By shill Date 2004-01-21 Time 15:13 Rev Time 1.50
Received By dpalmer Date 2004-01-05 Time 07:37 Sent To  
Notes
2004-01-05 00:00:00************ UNSAT *************
  
 1)NOTE: PLEASE SEE FAC 61G15-23.002.
 PLEASE INCLUDE ALL INFORMATION ON TITLE
 BLOCKS AS REQ'D FOR ENGINEERS.
 PLEASE SEE THAT THIS IS DONE FOR ALL
 PLANS/TRADES REGUARDLESS WEATHER COMMENT
 IS MADE BY OTHER REVIEWERS.
 PLEASE ALSO SEE 61G1-16.004 FOR ARCH'S.
 ABOVE PER FS 471 AND 481.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 7 Status F Date 2004-01-02 Cont ID  
Sent By dpalmer Date 2004-01-02 Time 06:36 Rev Time 0.25
Received By dpalmer Date 2004-01-02 Time 06:35 Sent To  
Notes
2004-01-02 00:00:00************* UNSAT ******************
  
 1)NOTE: PLEASE SEE THAT LIGHTING PROTECT
 -ION SYSTEM IS TO BE UNDER A SEPARATE
 PERMIT. PLEASE SUBMIT THESE SUBMITTALS
 WITH PLANS AND PERMIT APPLICATION.
 PLEASE SEE THAT VALUE IS INCLUDE ALL
 LABOR AND MATERIALS: EVEN IF OWNER
 SUPPLIED. 104.6.5 FBC ADMIN SEC.
  
 PLEASE SUBMIT THE ABOVE. IF THERE ARE
 ANY QUESTIONS, PLEASE CALL.
  
 ALL SUBMITTALS/PLANS PER 2002 NEC AND
 LATEST NFPA-780
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2003-11-17 Cont ID  
Sent By btrobaug Date 2003-11-17 Time 12:49 Rev Time 0.50
Received By btrobaug Date 2003-11-17 Time 12:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-07-25 Cont ID  
Sent By csiegber Date 2003-11-14 Time 15:08 Rev Time 2.00
Received By dpalmer Date 2003-07-25 Time 16:27 Sent To  
Notes
2003-07-25 00:00:00**** NOTES ON PLANS ****
  
 NOTES WRITTEN ON PLANS FROM THE DESIGNER
 OF RECORD.ONCE ALL INFORMATION FOR
 HYDRAULIC CALCULATIONS ARE COMPLETE, ALL
 INFORMATION FOR FIRE PUMP/ ATS AND
 ASSOCIATED EQUIPMENT MUST BE REVISED
 ON RISER DIAGRAM AND SUBMITTED FOR
 REVIEW.
 PLEASE ALSO NOTE, IF ALL ITEMS HAND
 NOTED ON PLANS STAY"AS-IS", PLEASE
 REPRINT RISER AND SUBMIT.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2003-07-17 Cont ID  
Sent By dpalmer Date 2003-07-17 Time 16:10 Rev Time 1.00
Received By dpalmer Date 2003-07-17 Time 16:10 Sent To  
Notes
2003-07-17 00:00:00*************** UNSAT ***************
  
 1)NOTE: PLEASE SEE NOTES PREVIOUS REVIEW
 S. PLEASE SUBMIT MORE INFORMATION FOR
 FIRE PUMP. HP, CODE LETTER, VOLTAGE,
 FEED AND OCP FROM GENERATOR/ ATS,
 ETC.
 REPSONSE ADDED FEEDER SIZE AND NOTE FOR
 OCP TO BE SET FOR LOCKED ROTOR CURRENT.
 NONE OF THIS CAN BE VERIFIED DUE TO
 LACK OF INFORMATION.
 PLEASE PROVIDE THIS INFORMATION ON RISER
 DIAGRAM AND PLANS. SPECS FROM MANUF.
 MAY BE SUBMITTED TO HELP FOR REVIEW AND
 /OR ANY FIRE REVIEW COMMENTS/QUESTIONS.
  
 PLEASE SEE ATTACHED LETTER FOR FS.
 553.80(2)(B)
  
 2)NOTE: AS PER CONVERSATION WITH
 ENGINEER, THREE SIGNED, DATED AND SEALED
 LETTERS WERE GOING TO ACCOMPANY PLANS
 THAT VERIFY ALL CONTINUOUS LOADS ARE
 AT 125%.215-3,230-42 ETC.
 PLEASE NOTE, THIS WAS NOT SUIBMITTED AND
 PLANS HAVE NOT BEEN REVISED OR NOTE
 THIS.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-05-21 Cont ID  
Sent By dpalmer Date 2003-05-21 Time 15:42 Rev Time 3.00
Received By dpalmer Date 2003-05-21 Time 15:42 Sent To  
Notes
2003-05-21 00:00:00*********** UNSAT **************
  
 1)NOTE: PLEASE SUBMIT ADDITIONAL
 INFORMATION FOR FIRE PUMP. SIZE (HP),
 FEEDERS, ETC. PLEASE NOTE ON PLANS
 FOR OCP TO BE SET FOR LOCKED ROTOR
 CURRENT. 695-4-B-1. PLEASE ALSO NOTE/
 CLARIFY MEANS OF DISCONNECT, RATED FOR
 LOAD , MANUAL. 230-76, 230-79.
  
  
 PLEASE NOTE, THE ABOVE SEEMS TO BE THE
 ONLY OUTSTANDING ISSUE.
 SPOKE TO ENGINEER ON 5/21/2003 AND HE
 TRY TO GET INFORMATION.
 PLEASE PROVIDE 3- SIGNED AND SEALED
 LETTERS FROM ENGINEER THAT VERIFIES ALL
 CONTINUOUS LOAD S ARE AT 125%.
 215-3,230-42 ETC
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-03-20 Cont ID  
Sent By dpalmer Date 2003-03-20 Time 05:17 Rev Time 7.00
Received By dpalmer Date 2003-03-19 Time 17:59 Sent To  
Notes
2003-03-20 00:00:00************ UNSAT *****************
  
 1)NOTE: PLEASE SEE PLANS, THERE ARE
 STILL MANY RECEPTS MISSING PER 210-52
 PLEASE ALSO SEE KITCHEN COUNTERSPACE
 PER 210-52-C1
  
 2)NOTE: PLEASE SEE SOME UNITS HAVE MISS-
 -ING SD`S INSIDE BEDROOMS OR ARE MISSING
 OUTSIDE. NFPA-72
  
 3)NOTE: MDPL AND MDPHARE SHOWN W/ NO
 MAINS?? PLEASE SEE E-503, ONE ? AND
 AS MLO. PLEASE SEE 230-70/230-2/230-72
  
 4)NOTE: PLEASE SHOW SIZE OF DS-EQ AND
 DS-LS. IT IS NOTED BY ALL NOTES ON
 RISER DIAGRAM THAT ATS,EQ&LS MDP`S ARE
 ALL 400A.HOWEVER UPON REVIEW OF SEC`S
 FROM FPL, EQ HAS ONLY ONE SET OF 3/0`S
 WHICH ARE ONLY RATED FOR 200A'S?
 PLEASE CLARIFY SIZING OF DISC AND SEC`S
 PLEASE ALSO PROVIDE AIC RATINGS FOR BOTH
 MAINS. EQ HAS "NOTE 8" FOR GREEN AND
 LS DOES NOT HAVE "NOTE 1"?
  
 5)NOTE: PLEASE CLARIFY GFI PROTECTION
 PER 517-17. IT WAS NOTED THAT GFI
 PROTECTION IS NOTED FOR MDPH. NO MAIN?
  
 6)NOTE: PLEASE SEE NOTE ON ELECTRICAL
 LOAD CALCS. MENTIONS 1ST 10KW@100% AND
 REMAINDER AT 40% PER 220-13.
 PLEASE SEE 220-13,, REMAINDER IS NOT 40%
 NEC SHOWS 50%.
 PLEASE CLARIFY/SHOW LOAD CALC FOR MDPH.
 E-509 SHOWS MDPA?
  
 7)NOTE: PLEASE SUBMIT AND SHOW ALL
 CONTINUOUS LOADS AT 125%, 215-3,230-42
 ETC.
  
 8)NOTE: PLEASE SEE UNIT PANEL SCHEDULES.
 ONLY SHOW ONE SMALL APPL CIRCUIT?
 PLEASE SEE NEC 210-11-C1
  
 9)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 PROTECTED CIRCUITS ON PANEL SCHEDULES
 FOR APT UNIT. 210-12
  
 10)NOTE:PLEASE SEE "TYPICAL" LIST SHOWN
 FROM 4WDL, PANELS SHOWN AS "SL`S".
  
 11)NOTE: PLEASE SEE UNIT TYPE "S" PANEL
 SCHEDULE SHOWN. SHOWN AS BEING #224
 WHEN YO GO TO RISER DIAGRAM, #224 IS
 BEING FED FROM "2NDL" AND YET 2NDL PANEL
 SCHEDULE DOES NOT SHOW A TYPE "S"??
 PLEASE CORRELATE PANEL SCHEDULES FOR
 THIS AND OTHERS.
  
 12)NOTE: PLEASE SEE THAT ELECTRICAL
 ROOM FOR FIRE PUMP IS SHOWN,BUT NOTHING
 SHOWN ON RISER DIAGRAM FOR FIRE PUMP/
 OCP/AWG??? PLEASE ALSO NOTE ON PLANS
 OCP FOR FIRE PUMP PER 695-4B-1
 NOT ENOUGH INFORMATION IN SPECS FOR
 FIRE PUMP/OCP/SIZE/CODE LETTER ETC.
 PLEASE GO OVER PLANS AND REVISE.
 PLEASE NOTE DUE TO PLANS NOT BEING
 COMPLETE THE FIRST TIME THEY CAME IN.
 SOME OF THESE COMMENTS ARE NEW.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-07-12 Cont ID  
Sent By dpalmer Date 2002-07-12 Time 08:50 Rev Time 0.00
Received By dpalmer Date 2002-07-11 Time 06:32 Sent To  
Notes
2002-07-12 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE SOME MISSING RECEPTS
 PER 210-52.
  
 2)NOTE: PLEASE NOTE THAT SOME ELECTRICAL
 PANELS ARE SHOWN IN BATHROOMS. PLEASE
 NOTE THIS IS NOT PERMITTED PER 240-24
  
 3)NOTE: PLEASE SEE 110-26/384-7 FOR
 INSTALLATION OF PANELS IN STORAGE AREAS.
 PLEASE HAVE DEDICATED ELECTRICAL SPACE
 SHOWN ON PLANS.
 PLEASE NOTE THIS INCLUDES ALL PANELS AS
 SHOWN IN STORAGE ROOMS.
  
 4)NOTE: PLEASE NOTE SOME MISSING RECEPTS
 PER 210-52H
  
 5)NOTE: PLEASENOTE LABELING OF EQUIP-
 -MENT FOR ELECTRICAL ROOM LAYOUT. PLEASE
 NOTE MORETHAN ONE PANEL/TRANS ALL BEING
 SHOWN AS "X"??.
  
 6)NOTE: PLEASE NOTE GROUNDING OF ALL
 TRANSFORMERS NEED TOMORE DETAILED?
 PER 250-30
  
 7)NOTE: PLEASE SHOW AMPERAGE DESIGNATION
 -S ON LINE DIAGRAM. PLEASE NOTE THAT IN
 ORDER TO VERIFY WIRE SIZES YOU WOULD
 HAVE TO TURN PAGES ABCK AND FORTH FOR
 EACH PANEL AND OR PIECE OF EQUIPMENT.
  
 8)NOTE: PLEASE SHOW TRANSFORMER INFORMA-
 TION ON LINE DIAGRAM ALSO.
  
 9)NOTE: PLEASE NOTE THAT E-206 NEEDS TO
 SHOW LAYOUT OF EQUIPMENT IN MAIN
 ELECTRICAL ROOM AND GENERATOR ROOM.
  
 10)NOTE: PLEASE SHOW HOW MDPL AND MDPH
 ARE BEING FED? FROM FPL?
  
 11)NOTE: PLEASE NOTE MDP`S ARE SHOWN AS
 277V/480 AND NO INFORMATION ON GFI
 PROTECTION, 230-95 ETC.
  
 12)NOTE: PLEASE NOTE NOT ENOUGH INFOR-
 -MATION FOR FIRE PUMP/SIZE/OCP ETC,,,,
  
 13)NOTE: PLEASE NOTE MISSING DISC MEANS
 ON LOAD SIDE OF TRANSFORMERS.240-21/
 384-16,,,
  
 14)NOTE: PLEASE NOTE TAPS ON LOAD SIDE
 OF ALL TRANSFORMERS. 240-21
  
 15)NOTE: PLEASE NOTE NOTHING SUBMITTED
 FOR GUARD HOUSE? GROUNDING? DISC MEANS
 225-31/250-32
  
 16)NOTE: PLEASE NOTE THAT NO MAINS ARE
 SHOWN FOR MDPL/MDPH.230-71/230-72/230-2
  
 17)NOTE: PLEASE NOTE NO GROUNDING ELEC-
 -TRODE. SYSTEM DETAIL SUBMITTED . 250-50
  
 18)NOTE: PLEASE NOTE THAT NO LOAD
 CALCULATIONS WERE SUBMITTED.215-5 ETC
 220-3,220-10,220-11,220-13,215-3,230-42
  
 19)NOTE: PLEASE SHOW WHERE FHAR 24 CFR
 100.205 ARE SHOWN.
  
 20)NOTE: PLEASE NOTE ARC FAULT FOR
 BEDRROMS.210-12
  
 PLEASE NOTE THAT PLANS ARE NOT COMPLETE
 FOR FULL REVIEW. IF THERE ARE ANY QUESTI
 ONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2003-03-10 Cont ID  
Sent By mamini Date 2003-03-10 Time 13:52 Rev Time 1.00
Received By mamini Date 2003-03-10 Time 13:52 Sent To  
Notes
2003-03-10 00:00:00PASSED:
 1. SEE PERMIT # 03030355 FOR UNDERGROUND
 UTILITIES AND SITE WORKS.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2002-06-11 Cont ID  
Sent By mamini Date 2002-06-11 Time 13:35 Rev Time 1.00
Received By mamini Date 2002-06-11 Time 13:35 Sent To  
Notes
2002-06-11 00:00:00FAILED :
 1. SEE PERMIT # 02060379 FOR REVIEW
 COMMENTS DATED 6-11-02.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 7 Status P Date 2004-10-28 Cont ID  
Sent By nmccray Date 2004-10-28 Time 10:54 Rev Time 0.00
Received By nmccray Date 2004-10-28 Time 10:54 Sent To  
Notes
2004-10-28 00:00:00POOL ENCLOSURE

Review Stop FIRE FIRE DEPARTMENT
Rev No 6 Status P Date 2004-05-05 Cont ID  
Sent By nmccray Date 2004-05-05 Time 15:04 Rev Time 0.00
Received By nmccray Date 2004-05-05 Time 15:04 Sent To  
Notes
2004-05-05 00:00:00SUBMITTALS FOR GENERATOR AND FIRE
 SPRINKLER PIPE AND FITTINGS. SEPARATE
 PLANS AND PERMIT APPLICATIONS ARE
 REQUIRED FOR GENERATOR AND FIRE
 SPRINKLER SYSTEM.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status F Date 2004-03-30 Cont ID  
Sent By nmccray Date 2004-03-30 Time 12:31 Rev Time 0.00
Received By nmccray Date 2004-03-30 Time 12:31 Sent To  
Notes
2004-03-30 00:00:00************DENIED**********************
 1) THE PLANS APPEARS TO BE REVISIONS NOT
 SUBMITTALS.
  
 2) CAN NOT FIND RECORD OF FIRE ALARM
 PERMIT,IF YOU HAVE A PERMIT FOR THIS
 SYSTEM PLEASE PROVIDE PROOF.
  
 3) PLEASE BE ADVISED THAT SEPARATE
 PERMIT APPLICATION AND SHOP DRAWING ARE
 REQUIRED FOR THE FIRE ALARM SYSTEM.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2004-01-08 Cont ID  
Sent By csiegber Date 2004-03-17 Time 15:56 Rev Time 0.00
Received By mcarsill Date 2004-01-08 Time 17:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-07-24 Cont ID  
Sent By csiegber Date 2003-11-06 Time 11:06 Rev Time 0.00
Received By nmccray Date 2003-07-24 Time 12:11 Sent To  
Notes
2003-07-24 00:00:00PASSED BY M.E. CARSILLO.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2003-04-24 Cont ID  
Sent By mwennerg Date 2003-04-24 Time 08:12 Rev Time 0.00
Received By mwennerg Date 2003-04-24 Time 08:12 Sent To  
Notes
2003-04-24 00:00:001) AL DINING ROOM A128,A128B, DISPLAYS
 ONLY ONE EXIT SIGN.
  
 2) IS THE DOOR SWING SHOWN IN DINING
 ROOM AREA A, SWINGING IN THE RIGHT
 DIRECTION.
  
 3) EXIT SIGN IN MULTI-USE FOYER C156
 LEADS WHERE.
  
 4) VERANDA'S REQUIRED TO BE FIRE
 SPRINKLER PROTECTED IF COMBUSTIBLE
 CONSTRUCTION OR COMBUSTIBLES ARE
 HANDLED OR STORED.
  
 5) CORRIDOR A301 NEEDS EXIT SIGN AT
 HALLWAY INTERSECTION.
  
 6) PLEASE INDICATE TRAVEL DISTANCES
 ON FLOORS 4,5,AND 6.
  
 7) PLEASE INDICATE WHICH ELEVATORS ARE
 STRETCHER ACCESSIBLE.
  
 8) PLEASE PROVIDE PRODUCT APPROVALS FOR
 WON-DOORS.
  
 9) WHAT PREVENTS PERSONS FROM SLIPPING
 ON THE MARBLE TREADS ON THE GRAND STAIR.
  
 10) PLEASE DISPLAY THE RESISTANT TO THE
 PASSAGE OF A 4" SPHERE ON HANDRAILS.
  
 11) PLEASE DISPLAY AISLES IN DINING
 ROOMS 177A AND 177B.
  
 12) THE LOCATION OF FIREFIGHTERS SMOKE
 CONTROL ATRIUM PANEL SHOULD BE LOCATED
 WHERE ALL OTHER LS SYSTEM PANELS ARE
 LOCATED.
  
 13) PLEASE PROVIDE TESTING REQUIREMENTS
 AND A SEQUENCE OF OPERATION FOR ATRIUM
 SMOKE CONTROL.
  
 14) FP SCHEDULE AND NOTES BELOW IT DO
 NOT CORRESPOND.
  
 15) PLEASE EXPLAIN WHY POOL AREA IS NOT
 FIRE SPRINKLER PROTECTED.
  
 16) HOW ARE TWO STANDPIPES SHOWN ON
 PLANS 4-6TH FLOORS ABLE TO COVER ALL
 AREAS OF THE BUILDING.
  
 17) PLEASE INDICATE HOW SECURITY
 FEATURES INSTALLED ON EXIT DOORS
 WILL EFFECT EXITING.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-06-20 Cont ID  
Sent By mcarsill Date 2002-06-20 Time 15:36 Rev Time 0.00
Received By mcarsill Date 2002-06-20 Time 15:36 Sent To  
Notes
2002-06-20 00:00:001) ANY NEW SECURITY GATES ARE TO BE
 PROPERLY PERMITTED. PROVISIONS ARE TO
 BE MADE FOR FIRE AND PARAMEDICAL
 ACCESS THRU THE GATES. IF THE GATES
 ARE ELECTRIC, PROVISIONS ARE TO BE MADE
 IN THE EVENT OF LOSS OF POWER.
  
 2) ALL INGRESS LANES ARE TO BE AT LEAST
 20 FEET IN CLEAR WIDTH.
  
 3) PLEASE INDENTIFY ON THE PLANS THE
 REQUIRED FIRE LANE LOCATIONS.
  
 4) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
  
 5) WILL THE GUARDHOUSE BE STAFFED FULL
 TIME OR PART TIME.
  
 6) SUITABLE FIRE HYDRANTS ARE TO BE
 PROVIDED FOR FIRE AND PARAMEDICAL
 EQUIPMENT DURING CONSTRUCTION.
  
 7) TEMPORARY STANDPIPE SYSTEMS ARE
 REQUIRED DURING CONSTRUCTION.
  
 8) IT APPEARS THAT ADDITIONAL FIRE
 HYDRANTS APPEAR TO BE NEEDED NEAR THE
 PROPOSED RESIDENTIAL BUILDING.
  
 9) VALVES TO FIRE HYDRANTS ARE TO BE
 NO FARTHER THAN FOUR FEET TO THEM.
  
 10) NEW FIRE HYDRANTS ARE TO BE PROVIDED
 WITH SEVEN AND HALF FEET CLEARANCE
 TO THE FRONT AND SIDES OF THEM.
 CLEARANCE OF AT LEAST FOUR FEET IS TO
 BE PROVIDED TO THE REAR OF THEM.
  
 11) TAMPER SWITCHES, CHAINS AND LOCKS
 ARE REQUIRED ON THE BACKFLOW DEVICES.
  
 12) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION INFOMATION FOR WALLS
 AND CEILINGS.
  
 13) KNOX-BOXES WILL BE REQUIRED FOR THE
 BUILDING.
  
 14) PLEASE PROVIDE PRESCRIPTIVE CODE
 REQUIREMENTS FOR ALUMINUM RAIL SYSTEM.
  
 15) EIFS COPING TRIM NOTED ON THE PLANS.
 PLEASE PROVIDE FLAME SPREAD DETAILS.
  
 16) PLEASE PROVIDE TRAVEL DISTANCES,
 COMMON PATHS OF TRAVEL, DEAD-END
 CORRIDORS ON THE LIFE SAFETY PLANS.
  
 17) ALL SHAFTWAYS THAT PERSONS CAN
 ENTER MUST BE MARKED "SHAFTWAY" IN
 RED LETTERS ON A WHITE BACKGROUND.
  
 18) SIGNS REQUIRED IN STAIRWELLS
 INDICATING STAIR NUMBER, TERMINUS,
 FLOOR LEVEL, ETC.
  
 19) AUTOMATIC SLIDING DOOR ASSEMBLIES
 TO COMPLY WITH APPLICABLE FIRE CODE
 REQUIREMENTS.
  
 20) LOCKS ON EXIT DOORS SHALL NOT
 REQUIRE THE USE OF A KEY, TOOL,
 SPECIAL KNOWLEDGE OR EFFORT. IF
 PERMITTED, DELAYED EGRESS OR ACCESS
 CONTROLLED LOCKS WILL BE ALLOWED.
  
 21) PORTECOCHERS'S IF FIRE AND
 PARAMEDICAL EQUIPMENT ARE EXPECTED TO
 PASS UNDERNEATH MUST BE AT LEAST
 THIRTEEN FEET SIX INCHES HIGH.
  
 22) IS THE DOOR IN MEDICAL CLINIC C134
 NEAR MITZVAH STORAGE C115 SWINGING IN
 THE RIGHT DIRECTION.
  
 23) ELECTRICAL PAGES AND LIFE SAFETY
 PLANS DO NOT MATCH WITH REGARDS TO
 EXIT SIGN LOCATIONS.
  
 24) MORE DETAILS REQUIRED ON FIRE PUMP.
  
 25) MORE DETAILS REQUIRED ON EMERGENCY
 GENERATOR.
  
 26) ELEVATORS TO COMPLY WITH 61C-5.
  
 27) FIRE PROTECTION NOTES # 9 INDICATES
 SIX SPARE FIRE SPRINKLER HEADS WILL
 BE PROVIDED. SIX SPARE SPRINKLER HEADS
 ARE WHEN THREE HUNDRED FIRE SPRINKLERS
 OR LESS ARE USED.
  
 28) FIRE SPRINKLER PLANS ARE INCOMPLETE.
 PLEASE PROVIDE COMPLETE FIRE SPRINKLER
 PLANS. NO FIRE DEPARTMENT CONNECTION'S
 ARE SHOWN.
  
 29) FIRE STANDPIPE INFORMATION MISSING
 FROM PLANS. PLEASE PROVIDE STANDPIPE
 RISER DIAGRAMS.
  
 30) HOW WILL THE BUILDING BE LICENSED.
 WILL IT BE RESIDENTIAL APARTMENTS,
 ADULT CONGREGATE LIVING FACILITY. PLEASE
 ADVISE.
  
 31) VISIBLE FIRE ALARM DEVICES ARE
 REQUIRED WITHIN APARTMENTS DESIGNED FOR
 THE HEARING IMPAIRED.
  
 32) ASSEMBLY ROOMS SUBJECT TO AN
 OCCUPANCY OF 100 OR MORE PERSONS MUST
 BE PROVIDED WITH PANIC HARDWARE ON THE
 EXIT DOORS.
  
 33) PLEASE PROVIDE DETAILS ON SERVICE
 TYPE SHAFTS.
  
 34) FIRE HYDRANTS ARE TO BE LOCATED
 WITHIN 150 FEET OF FIRE DEPARTMENT
 CONNECTIONS.
  
 35) SEVERAL PAGES OF PLANS ARE NOT
 SIGNED AND SEALED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 83 Status N Date 2005-01-19 Cont ID  
Sent By mjacobs Date 2005-01-19 Time 12:34 Rev Time 0.00
Received By mjacobs Date 2005-01-19 Time 12:34 Sent To B
Notes
2005-01-19 00:00:00TO "SH" DESK/SUBMITTALS.

Review Stop I INCOMING/PROCESSING
Rev No 82 Status N Date 2004-12-23 Cont ID  
Sent By mjacobs Date 2004-12-23 Time 08:12 Rev Time 0.00
Received By mjacobs Date 2004-12-23 Time 08:12 Sent To  
Notes
2004-12-23 00:00:00SENT TO "HAROLD PISKURA" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 81 Status N Date 2004-12-01 Cont ID  
Sent By mjacobs Date 2004-12-01 Time 12:50 Rev Time 0.00
Received By mjacobs Date 2004-12-01 Time 12:50 Sent To B
Notes
2004-12-01 00:00:00SENT TO "SH" DESK./PRODUCT APPROVALS/
 STOREFRONT ENTERANCE/DOORS NOA'S

Review Stop I INCOMING/PROCESSING
Rev No 80 Status N Date 2004-11-30 Cont ID  
Sent By mjacobs Date 2004-11-30 Time 12:31 Rev Time 0.00
Received By mjacobs Date 2004-11-30 Time 12:31 Sent To P
Notes
2004-11-30 00:00:00SENT TO "P" BOX/REV.

Review Stop I INCOMING/PROCESSING
Rev No 79 Status N Date 2004-11-24 Cont ID  
Sent By mjacobs Date 2004-11-24 Time 14:41 Rev Time 0.00
Received By mjacobs Date 2004-11-24 Time 14:41 Sent To B
Notes
2004-11-24 00:00:00SENT TO "SH" DESK/SUBMITTAL.

Review Stop I INCOMING/PROCESSING
Rev No 78 Status N Date 2004-11-19 Cont ID  
Sent By csiegber Date 2004-11-19 Time 14:37 Rev Time 0.00
Received By csiegber Date 2004-11-19 Time 14:37 Sent To B
Notes
2004-11-19 00:00:00TO SH DESK/SUBMITTALS
 CALCULATIONS FOR HOUSEKEEPING PADS

Review Stop I INCOMING/PROCESSING
Rev No 77 Status N Date 2004-11-18 Cont ID  
Sent By mjacobs Date 2004-11-18 Time 08:21 Rev Time 0.00
Received By mjacobs Date 2004-11-18 Time 08:21 Sent To B
Notes
2004-11-18 00:00:00SENT TO SH DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 76 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 15:26 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 15:26 Sent To AD
Notes
2004-11-12 00:00:00COMM BD#45

Review Stop I INCOMING/PROCESSING
Rev No 75 Status N Date 2004-11-04 Cont ID  
Sent By csiegber Date 2004-11-04 Time 09:20 Rev Time 0.00
Received By csiegber Date 2004-11-04 Time 09:20 Sent To  
Notes
2004-11-04 00:00:00SENT TO HP DESK/REVISION TO BALCONY
 RAILING CONNECTION

Review Stop I INCOMING/PROCESSING
Rev No 74 Status N Date 2004-08-18 Cont ID  
Sent By csiegber Date 2004-08-18 Time 13:02 Rev Time 0.00
Received By csiegber Date 2004-08-18 Time 13:02 Sent To B
Notes
2004-08-18 00:00:00TO SH DESK/SUBMITTAL
 05A-23-05120-0

Review Stop I INCOMING/PROCESSING
Rev No 73 Status N Date 2004-07-26 Cont ID  
Sent By csiegber Date 2004-07-26 Time 14:56 Rev Time 0.00
Received By csiegber Date 2004-07-26 Time 14:56 Sent To B
Notes
2004-07-26 00:00:00TO SH DESK/SUBMITTALS
 STOREFRONT DOORS & ENTRANCE PA
 STOREFRONT DOORS SHOP DRAWINGS
 VERANDA & FRAMEWORK
 DINING ROOM/C777SOFFIT FRAMING
 RFI#476R
 PA & SHOP DRAINGS FOR OVERHEAD ROLL-UP
 DOORS

Review Stop I INCOMING/PROCESSING
Rev No 72 Status N Date 2004-07-16 Cont ID  
Sent By csiegber Date 2004-07-16 Time 14:40 Rev Time 0.00
Received By csiegber Date 2004-07-16 Time 14:40 Sent To B
Notes
2004-07-16 00:00:00TO SH DESK/SUBMITTAL
 RFI #556
 ARCHITECTURAL & STRUCTURAL FEATURES AT
 DEDICATION WALL
 SUBMITTAL #020-03-03000-0 SIDEWALK
 CONCRETE MIX DESIGNS

Review Stop I INCOMING/PROCESSING
Rev No 71 Status N Date 2004-07-07 Cont ID  
Sent By csiegber Date 2004-07-07 Time 15:42 Rev Time 0.00
Received By csiegber Date 2004-07-07 Time 15:42 Sent To B
Notes
2004-07-07 00:00:00TO SH DESK/REV/SIGNS

Review Stop I INCOMING/PROCESSING
Rev No 70 Status N Date 2004-07-01 Cont ID  
Sent By csiegber Date 2004-07-01 Time 15:53 Rev Time 0.00
Received By csiegber Date 2004-07-01 Time 15:53 Sent To Z
Notes
2004-07-01 00:00:00REV/LANDSCAPING

Review Stop I INCOMING/PROCESSING
Rev No 69 Status N Date 2004-07-01 Cont ID  
Sent By csiegber Date 2004-07-01 Time 14:18 Rev Time 0.00
Received By csiegber Date 2004-07-01 Time 14:18 Sent To B
Notes
2004-07-01 00:00:00TO SH DESK/6 SUBMITTALS
 METAL TRUSS SHOP DRAWINGS
 FRAMING SHOPS & CALCS
 ELEVATED PLANTER SHOP DRAWS
 TYPE HA,2,& Y WINDOW SHOPS & CALCS
 RFI#476R
 ALAND ORAND STAIR SHOP DRGS.

Review Stop I INCOMING/PROCESSING
Rev No 68 Status N Date 2004-06-25 Cont ID  
Sent By csiegber Date 2004-06-25 Time 12:11 Rev Time 0.00
Received By csiegber Date 2004-06-25 Time 12:11 Sent To B
Notes
2004-06-25 00:00:00TO SH DESK/3 SUBMITTALS/FRAMEWORK-
 FRAMEWORK& WINDOW SUBMITTAL & SHOP
 DRAWINGS LETTER & A-3 SHEET ARCH BEAM

Review Stop I INCOMING/PROCESSING
Rev No 67 Status N Date 2004-06-25 Cont ID  
Sent By csiegber Date 2004-06-25 Time 12:06 Rev Time 0.00
Received By csiegber Date 2004-06-25 Time 12:06 Sent To M
Notes
2004-06-25 00:00:00TO PK DESK/DICK BOWMAN ATTN

Review Stop I INCOMING/PROCESSING
Rev No 66 Status N Date 2004-06-11 Cont ID  
Sent By csiegber Date 2004-06-11 Time 09:09 Rev Time 0.00
Received By csiegber Date 2004-06-11 Time 09:09 Sent To M
Notes
2004-06-11 00:00:00TO PK BOX/SUBMITTAL/DRYER VENTING REQD
 BY D. BOWMAN

Review Stop I INCOMING/PROCESSING
Rev No 65 Status N Date 2004-06-11 Cont ID  
Sent By csiegber Date 2004-06-11 Time 09:08 Rev Time 0.00
Received By csiegber Date 2004-06-11 Time 09:08 Sent To B
Notes
2004-06-11 00:00:00TO SH DESK/SUBMITTAL/PARTIAL 3RD FLR
 FRAMING PLAN

Review Stop I INCOMING/PROCESSING
Rev No 64 Status N Date 2004-06-08 Cont ID  
Sent By csiegber Date 2004-06-08 Time 09:22 Rev Time 0.00
Received By csiegber Date 2004-06-08 Time 09:21 Sent To P
Notes
2004-06-08 00:00:00TO KS BOX/SUBMITTAL/SPEE D CHANNEL DRAIN

Review Stop I INCOMING/PROCESSING
Rev No 63 Status N Date 2004-06-08 Cont ID  
Sent By csiegber Date 2004-06-08 Time 09:16 Rev Time 0.00
Received By csiegber Date 2004-06-08 Time 09:16 Sent To B
Notes
2004-06-08 00:00:00TO SH DESK/6 SUBMITTALS/VERTICAL EXP
 JOINT COVER - MEZZ STRUCTURAL STEEL LAY
 OUT - FOR YOUR FILES -CALCS
 METAL TRUSS SHOP DRWGS & BROWARD COUNTY
 PA

Review Stop I INCOMING/PROCESSING
Rev No 62 Status N Date 2004-05-26 Cont ID  
Sent By alange Date 2004-05-26 Time 09:16 Rev Time 0.00
Received By alange Date 2004-05-26 Time 09:15 Sent To B
Notes
2004-05-26 00:00:00TO SH DESK

Review Stop I INCOMING/PROCESSING
Rev No 61 Status N Date 2004-05-26 Cont ID  
Sent By alange Date 2004-05-26 Time 09:14 Rev Time 0.00
Received By alange Date 2004-05-26 Time 09:14 Sent To B
Notes
2004-05-26 00:00:00TO SH DESK

Review Stop I INCOMING/PROCESSING
Rev No 60 Status N Date 2004-05-26 Cont ID  
Sent By alange Date 2004-05-26 Time 09:13 Rev Time 0.00
Received By alange Date 2004-05-26 Time 09:13 Sent To E
Notes
2004-05-26 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 59 Status N Date 2004-05-26 Cont ID  
Sent By alange Date 2004-05-26 Time 09:12 Rev Time 0.00
Received By alange Date 2004-05-26 Time 09:12 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 58 Status N Date 2004-05-13 Cont ID  
Sent By csiegber Date 2004-05-13 Time 08:43 Rev Time 0.00
Received By csiegber Date 2004-05-13 Time 08:43 Sent To B
Notes
2004-05-13 00:00:00TO SH DESK/SUBMITTALS/ELEVATED PLANTER
 SHOP DRAWS/WEST AL ROOF FRAMING & HIGH
 ROOF BRACKET SHOPS & CALCS/BONDING AGENT
 FOR MASONRY REPAIRS/REINF CONC BEAM

Review Stop I INCOMING/PROCESSING
Rev No 57 Status N Date 2004-05-06 Cont ID  
Sent By csiegber Date 2004-05-06 Time 14:22 Rev Time 0.00
Received By csiegber Date 2004-05-06 Time 14:22 Sent To B
Notes
2004-05-06 00:00:00TO SH DESK/SUBMITTAL/BOND BEAM

Review Stop I INCOMING/PROCESSING
Rev No 56 Status N Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-04-26 Time 11:32 Rev Time 0.00
Received By csiegber Date 2004-04-26 Time 11:32 Sent To B
Notes
2004-04-26 00:00:00TO SH DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 55 Status N Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-04-26 Time 11:26 Rev Time 0.00
Received By csiegber Date 2004-04-26 Time 11:26 Sent To  
Notes
2004-04-26 00:00:00TO PK DESK/SUBMITTAL/4TH FLR DUCTWORK
 & 5TH FLOOR & TRANE MECH ROOM LAYOUTS
 & 6TH FLOOR

Review Stop I INCOMING/PROCESSING
Rev No 54 Status N Date 2004-04-20 Cont ID  
Sent By csiegber Date 2004-04-20 Time 15:56 Rev Time 0.00
Received By csiegber Date 2004-04-20 Time 15:56 Sent To B
Notes
2004-04-20 00:00:00TO SH 6 SUBMITTALS
 08D-02-08331-0 PA OVERHEAD ROLL UP DOORS
 RALING@C-160 & SPRAY FIREPROOFING DATA
 STOREFRONT DOORS & ENTRANCE PA
 STOREFRONT DOOR SHOP DRAWINGS
 STAIR B SHOP DRAWS

Review Stop I INCOMING/PROCESSING
Rev No 53 Status N Date 2004-04-20 Cont ID  
Sent By csiegber Date 2004-04-20 Time 15:55 Rev Time 0.00
Received By csiegber Date 2004-04-20 Time 15:55 Sent To M
Notes
2004-04-20 00:00:00TO PK BOX/SUBMITTAL
 15V-72-15880-0 SEF-S DAMPER &
 SIDEWALL SUPPLY GRILLE W/DAMPER

Review Stop I INCOMING/PROCESSING
Rev No 52 Status N Date 2004-04-16 Cont ID  
Sent By csiegber Date 2004-04-16 Time 14:37 Rev Time 0.00
Received By csiegber Date 2004-04-16 Time 14:37 Sent To B
Notes
2004-04-16 00:00:00TO SH DESK/2 RESUBS/TRUSS CONNECTION
 DETAIL & STRUCTURAL MODIFICATION

Review Stop I INCOMING/PROCESSING
Rev No 51 Status N Date 2004-04-13 Cont ID  
Sent By shill Date 2004-04-13 Time 10:14 Rev Time 0.00
Received By shill Date 2004-04-13 Time 10:14 Sent To M
Notes
2004-04-13 00:00:00SUBMITTAL TO PK DESK

Review Stop I INCOMING/PROCESSING
Rev No 50 Status N Date 2004-03-30 Cont ID  
Sent By alange Date 2004-03-30 Time 14:40 Rev Time 0.00
Received By alange Date 2004-03-30 Time 14:40 Sent To B
Notes
2004-03-30 00:00:00TO SH DESK

Review Stop I INCOMING/PROCESSING
Rev No 49 Status N Date 2004-03-30 Cont ID  
Sent By alange Date 2004-03-30 Time 13:26 Rev Time 0.00
Received By alange Date 2004-03-30 Time 13:26 Sent To B
Notes
2004-03-30 00:00:00TO SH DESK

Review Stop I INCOMING/PROCESSING
Rev No 48 Status N Date 2004-03-30 Cont ID  
Sent By alange Date 2004-03-30 Time 13:20 Rev Time 0.00
Received By alange Date 2004-03-30 Time 13:20 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 47 Status N Date 2004-03-17 Cont ID  
Sent By csiegber Date 2004-03-17 Time 15:58 Rev Time 0.00
Received By csiegber Date 2004-03-17 Time 15:58 Sent To M
Notes
2004-03-17 00:00:00TO PK BOX/EXHAUST FAN FOR POWDER ROOM/
 SUPPLY FANS/POOL A/C SYSTEM/AIR HANDLING
 UNITS

Review Stop I INCOMING/PROCESSING
Rev No 46 Status N Date 2004-03-17 Cont ID  
Sent By csiegber Date 2004-03-17 Time 15:57 Rev Time 0.00
Received By csiegber Date 2004-03-17 Time 15:57 Sent To P
Notes
2004-03-17 00:00:00TO KS BOX/WATER FILTER SYSTEM/GAS BOSST
 ER HEATER

Review Stop I INCOMING/PROCESSING
Rev No 45 Status N Date 2004-03-17 Cont ID  
Sent By csiegber Date 2004-03-17 Time 15:56 Rev Time 0.00
Received By csiegber Date 2004-03-17 Time 15:56 Sent To FIRE
Notes
2004-03-17 00:00:00PIPE,FITTINGS,VALVES,HEADS

Review Stop I INCOMING/PROCESSING
Rev No 44 Status N Date 2004-03-17 Cont ID  
Sent By csiegber Date 2004-03-17 Time 15:54 Rev Time 0.00
Received By csiegber Date 2004-03-17 Time 15:54 Sent To E
Notes
2004-03-17 00:00:00TO BT DESK/SUBMITTAL/FIRE ALARM/
 GENERATOR/ATS

Review Stop I INCOMING/PROCESSING
Rev No 43 Status N Date 2004-03-16 Cont ID  
Sent By csiegber Date 2004-03-16 Time 16:13 Rev Time 0.00
Received By csiegber Date 2004-03-16 Time 16:13 Sent To P
Notes
2004-03-16 00:00:00TO KS BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 42 Status N Date 2004-03-05 Cont ID  
Sent By csiegber Date 2004-03-05 Time 15:45 Rev Time 0.00
Received By csiegber Date 2004-03-05 Time 15:45 Sent To FIRE
Notes
2004-03-05 00:00:00SUBMITTAL/1619-09-16721-0
 FIRE ALARMS/LIFE SAFETY SYSTEM/SHOD DRAW

Review Stop I INCOMING/PROCESSING
Rev No 41 Status N Date 2004-03-05 Cont ID  
Sent By csiegber Date 2004-03-05 Time 15:42 Rev Time 0.00
Received By csiegber Date 2004-03-05 Time 15:41 Sent To B
Notes
2004-03-05 00:00:00TO SH DESK/SUBMITTAL/2 HR HORZ DRAFTWALL
 & MISC LETTERS

Review Stop I INCOMING/PROCESSING
Rev No 40 Status N Date 2004-03-05 Cont ID  
Sent By csiegber Date 2004-03-05 Time 08:08 Rev Time 0.00
Received By csiegber Date 2004-03-05 Time 08:08 Sent To B
Notes
2004-03-05 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 39 Status N Date 2004-03-05 Cont ID  
Sent By csiegber Date 2004-03-05 Time 08:06 Rev Time 0.00
Received By csiegber Date 2004-03-05 Time 08:06 Sent To B
Notes
2004-03-05 00:00:00TO SH DESK/SUBMITTAL/LETTERS

Review Stop I INCOMING/PROCESSING
Rev No 38 Status N Date 2004-03-04 Cont ID  
Sent By shill Date 2004-03-04 Time 10:14 Rev Time 0.00
Received By shill Date 2004-03-04 Time 10:14 Sent To M
Notes
2004-03-04 00:00:00DUCTWORK SHOPS SENT TO H.MOSER DESK
 PER PK

Review Stop I INCOMING/PROCESSING
Rev No 37 Status N Date 2004-03-03 Cont ID  
Sent By csiegber Date 2004-03-03 Time 10:24 Rev Time 0.00
Received By csiegber Date 2004-03-03 Time 10:24 Sent To B
Notes
2004-03-03 00:00:00TO SH DESK/ROOFING DATA SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 36 Status N Date 2004-03-03 Cont ID  
Sent By csiegber Date 2004-03-03 Time 10:22 Rev Time 0.00
Received By csiegber Date 2004-03-03 Time 10:22 Sent To B
Notes
2004-03-03 00:00:00TO SH DESK/SUBMITTAL/BROWARD CO PA

Review Stop I INCOMING/PROCESSING
Rev No 35 Status N Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-02-27 Time 14:04 Rev Time 0.00
Received By csiegber Date 2004-02-27 Time 14:04 Sent To M
Notes
2004-02-27 00:00:00TO PK BOX/SUBMITTAL/DUCTOR PRODUCT DATA

Review Stop I INCOMING/PROCESSING
Rev No 34 Status N Date 2004-02-25 Cont ID  
Sent By csiegber Date 2004-02-25 Time 15:57 Rev Time 0.00
Received By csiegber Date 2004-02-25 Time 15:57 Sent To B
Notes
2004-02-25 00:00:00TO SH DESK/SUBMITTAL 06B-06-06402

Review Stop I INCOMING/PROCESSING
Rev No 33 Status N Date 2004-02-25 Cont ID  
Sent By csiegber Date 2004-02-25 Time 15:16 Rev Time 0.00
Received By csiegber Date 2004-02-25 Time 15:16 Sent To B
Notes
2004-02-25 00:00:00TO SH DESK/FRAMING @ GATEHOUSE

Review Stop I INCOMING/PROCESSING
Rev No 32 Status N Date 2004-02-13 Cont ID  
Sent By csiegber Date 2004-02-13 Time 16:44 Rev Time 0.00
Received By csiegber Date 2004-02-13 Time 16:44 Sent To P
Notes
2004-02-13 00:00:00TO KS BOX/SUBMITTAL/SUPPORTS & HANGARS

Review Stop I INCOMING/PROCESSING
Rev No 31 Status N Date 2004-02-13 Cont ID  
Sent By csiegber Date 2004-02-13 Time 16:44 Rev Time 0.00
Received By csiegber Date 2004-02-13 Time 16:44 Sent To M
Notes
2004-02-13 00:00:00TO PK BOX/SUBMITTAL/PUM INERTIA BASES

Review Stop I INCOMING/PROCESSING
Rev No 30 Status N Date 2004-02-13 Cont ID  
Sent By csiegber Date 2004-02-13 Time 16:33 Rev Time 0.00
Received By csiegber Date 2004-02-13 Time 16:34 Sent To B
Notes
2004-02-13 00:00:00TO SH DESK/SUBMITTAL-2 & 3 FLR DUCTWORK
 SHOP DRAWS & RL UNIT KITCHEN & BATH
 CAB SHOP DRAWS & FAMILY ROOMS A-103,203,
 303

Review Stop I INCOMING/PROCESSING
Rev No 29 Status N Date 2004-02-06 Cont ID  
Sent By csiegber Date 2004-02-06 Time 16:38 Rev Time 0.00
Received By csiegber Date 2004-02-06 Time 16:38 Sent To B
Notes
2004-02-06 00:00:00TO SH DESK/2 SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 28 Status N Date 2004-01-21 Cont ID  
Sent By shill Date 2004-01-21 Time 15:18 Rev Time 0.00
Received By shill Date 2004-01-21 Time 15:18 Sent To M
Notes
2004-01-21 00:00:00SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 27 Status N Date 2004-01-21 Cont ID  
Sent By shill Date 2004-01-21 Time 15:17 Rev Time 0.00
Received By shill Date 2004-01-21 Time 15:17 Sent To P
Notes
2004-01-21 00:00:00SUBMITTAL (ROOF DRAINS)

Review Stop I INCOMING/PROCESSING
Rev No 26 Status N Date 2004-01-21 Cont ID  
Sent By shill Date 2004-01-21 Time 15:13 Rev Time 0.00
Received By shill Date 2004-01-21 Time 15:13 Sent To E
Notes
2004-01-21 00:00:00SUBMITTAL - TO DVP DESK

Review Stop I INCOMING/PROCESSING
Rev No 25 Status N Date 2004-01-21 Cont ID  
Sent By csiegber Date 2004-01-21 Time 11:56 Rev Time 0.00
Received By csiegber Date 2004-01-21 Time 11:56 Sent To B
Notes
2004-01-21 00:00:00TO SH DESK/SUBMITTAL/NON-SHRINK GROUT/
 BONDING AGENT/DOCK LIFT/FRY REGLET PROD
 DATA/PVC ROOFING/LIGHTING PROTECTION
 SHOP DRAW/CODING TOWER SUPPORT/ROOF
 DRAIN EXT/METAL FRAMING/DOORS & FRAMES
 DATA/EAR & MARSHOP/CHILLER ROOM/LINE
 TYPE FIRE DAMPERS/FIRE PROOF AT SLABS/
 BRAND STAIR/MOD ROOF DATA/MEZ STRUC STEE
 L/DR TRUSS SHOP DWGS/IRRIG SYS/FLOOR
 RESHORING

Review Stop I INCOMING/PROCESSING
Rev No 24 Status N Date 2004-01-20 Cont ID  
Sent By csiegber Date 2004-01-20 Time 16:33 Rev Time 0.00
Received By csiegber Date 2004-01-20 Time 16:33 Sent To B
Notes
2004-01-20 00:00:00TO SH DESK/SUBMITTALS/SHORING/SHOPS &
 CALCS

Review Stop I INCOMING/PROCESSING
Rev No 23 Status N Date 2004-01-20 Cont ID  
Sent By csiegber Date 2004-01-20 Time 16:32 Rev Time 0.00
Received By csiegber Date 2004-01-20 Time 16:32 Sent To B
Notes
2004-01-20 00:00:00TO SH DESK/SUBMITTALS/FINISH HARDWARE

Review Stop I INCOMING/PROCESSING
Rev No 22 Status N Date 2003-12-23 Cont ID  
Sent By csiegber Date 2003-12-23 Time 12:53 Rev Time 0.00
Received By csiegber Date 2003-12-23 Time 12:53 Sent To B
Notes
2003-12-23 00:00:00TO HP DESK/5 SUBMITTALS
 3RD FLR REBAR/PT CABELING/5 FLR SHORING/
 AL ROOF REBAR/PT TYPICAL DETAIL

Review Stop I INCOMING/PROCESSING
Rev No 21 Status N Date 2003-12-23 Cont ID  
Sent By csiegber Date 2003-12-23 Time 11:33 Rev Time 0.00
Received By csiegber Date 2003-12-23 Time 11:33 Sent To M
Notes
2003-12-23 00:00:00TO PK BOX/SUBMITTAL/DUCT WORK & COOLING
 TOWERS

Review Stop I INCOMING/PROCESSING
Rev No 20 Status N Date 2003-12-17 Cont ID  
Sent By csiegber Date 2003-12-17 Time 09:18 Rev Time 0.00
Received By csiegber Date 2003-12-17 Time 09:18 Sent To  
Notes
2003-12-17 00:00:00SUBMITTALS: 10 PA/SHOP DRAWS-MECH
 1 PA-ELEC; 2 FIRE-PA; 5 PLUMB-PA
 8-PA/SHOP DRAWS-BLDG

Review Stop I INCOMING/PROCESSING
Rev No 19 Status N Date 2003-12-16 Cont ID  
Sent By csiegber Date 2003-12-16 Time 14:27 Rev Time 0.00
Received By csiegber Date 2003-12-16 Time 14:27 Sent To  
Notes
2003-12-16 00:00:00TO COMM BD#40

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2003-11-26 Cont ID  
Sent By csiegber Date 2004-05-05 Time 14:11 Rev Time 0.00
Received By csiegber Date 2003-11-26 Time 13:51 Sent To  
Notes
2003-11-26 00:00:00TO HP DESK/SUBMITTAL/RL ROOF PT & REBAR
 SHOP DWGS

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2003-11-26 Cont ID  
Sent By csiegber Date 2003-11-26 Time 13:50 Rev Time 0.00
Received By csiegber Date 2003-11-26 Time 13:50 Sent To B
Notes
2003-11-26 00:00:00TO HP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:28 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 15:28 Sent To B
Notes
2003-11-21 00:00:00TO HP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2003-11-17 Cont ID  
Sent By csiegber Date 2003-11-17 Time 14:33 Rev Time 0.00
Received By csiegber Date 2003-11-17 Time 14:33 Sent To B
Notes
2003-11-17 00:00:00TO HP DESK/RESUB 3RD FLR

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2003-11-14 Cont ID  
Sent By csiegber Date 2003-11-14 Time 14:56 Rev Time 0.00
Received By csiegber Date 2003-11-14 Time 14:57 Sent To  
Notes
2003-11-14 00:00:00SEE FRONT SCREEN NOTEPAD

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2003-11-12 Cont ID  
Sent By csiegber Date 2003-11-12 Time 09:03 Rev Time 0.00
Received By csiegber Date 2003-11-12 Time 09:03 Sent To B
Notes
2003-11-12 00:00:00TO HP DESK/6TH FLR RL WING PT CABELING

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2003-11-06 Cont ID  
Sent By csiegber Date 2003-11-06 Time 11:06 Rev Time 0.00
Received By csiegber Date 2003-11-06 Time 11:06 Sent To FIRE
Notes
2003-11-06 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2003-11-04 Cont ID  
Sent By csiegber Date 2003-11-04 Time 09:11 Rev Time 0.00
Received By csiegber Date 2003-11-04 Time 09:11 Sent To B
Notes
2003-11-04 00:00:00TO HP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2003-10-10 Cont ID  
Sent By csiegber Date 2003-10-10 Time 15:36 Rev Time 0.00
Received By csiegber Date 2003-10-10 Time 15:36 Sent To B
Notes
2003-10-10 00:00:00TO HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2003-10-02 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:30 Rev Time 0.00
Received By csiegber Date 2003-10-02 Time 11:30 Sent To  
Notes
2003-10-02 00:00:00TO COMM BD#4

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2003-10-02 Cont ID  
Sent By csiegber Date 2003-10-02 Time 08:14 Rev Time 0.00
Received By csiegber Date 2003-10-02 Time 08:14 Sent To P
Notes
2003-10-02 00:00:00TO KS BOX

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-10-01 Cont ID  
Sent By csiegber Date 2003-10-01 Time 15:14 Rev Time 0.00
Received By csiegber Date 2003-10-01 Time 15:14 Sent To B
Notes
2003-10-01 00:00:00TO HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-10-01 Cont ID  
Sent By csiegber Date 2003-10-01 Time 11:48 Rev Time 0.00
Received By csiegber Date 2003-10-01 Time 11:48 Sent To B
Notes
2003-10-01 00:00:00TO HP DESK/PER ST ON 9/16/03 BOX TO HP
 BOX WAS MOVED FOR CARPETING AND NOT GIVE
 N TO HP

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-16 Cont ID  
Sent By sthyng Date 2003-09-16 Time 13:46 Rev Time 0.00
Received By sthyng Date 2003-09-16 Time 13:45 Sent To  
Notes
2003-09-16 00:00:00ROUTED SUBMITTALS
  
 BLDG TO HP DESK
 MECHANICAL TO PK DESK
 PLUMBING TO KS DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-15 Cont ID  
Sent By shernand Date 2003-05-15 Time 16:20 Rev Time 0.00
Received By shernand Date 2003-05-15 Time 16:20 Sent To  
Notes
2003-05-15 00:00:00COMM BOARD #58,PLANS AND SPECS ON BOTTOM
 TWO RACKS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-14 Cont ID  
Sent By sthyng Date 2003-04-14 Time 17:37 Rev Time 0.00
Received By sthyng Date 2003-04-14 Time 17:37 Sent To  
Notes
2003-04-14 00:00:00REVIEWED BY ALL TRADES; PENDING ZONING
 REVIEW - REMOVED FROM BOX 38, ON TABLE
 AND ROLLED PLANS IN CONFERENCE ROOM

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-13 Cont ID  
Sent By sthyng Date 2003-03-13 Time 09:15 Rev Time 0.00
Received By sthyng Date 2003-03-13 Time 09:15 Sent To  
Notes
2003-03-13 00:00:00COMM BOARD #38
 3 ROLLED PLANS ON RACK, MARKED MORSE#38
 STACK OF DOCUMENTS & APP IN BIN#38

Review Stop M MECHANICAL (A/C)
Rev No 21 Status P Date 2004-12-08 Cont ID  
Sent By pkrauss Date 2004-12-08 Time 07:19 Rev Time 1.50
Received By pkrauss Date 2004-12-07 Time 17:11 Sent To  
Notes
2004-12-07 00:00:00REVISED SHEETS:
 M-002/PUMP SCH, FAN COIL SCH (E),
 DIFFUSER SCH (EG-4).
 M-003/EXHAUST FAN SCH (EF-H)
 M-101/ATRIUM SEQUENCE OF OPERATION &
 GENERAL NOTES.
 M-102/SMOKE CONTROL SYSTEM
 M-202/DRYER VENT & NOTES ADDED
 M-206/DRYER VENT
 M-208/DUCT MODIFICATION
 M-209/DRYER VENT
 M-301/MECHANICAL ROMM DUCTWORK
 M-309/PIPING MODIFICATION TO SECONDARDY
 PUMPS
 M-310/PIPING TO SECONDARY PUMP
 M-311/IN-LINE PUMP DETAIL
 M-601/POOL UNIT DETAIL
 M-602/FAN COIL DETAIL
  
  

Review Stop M MECHANICAL (A/C)
Rev No 20 Status P Date 2004-06-11 Cont ID  
Sent By pkrauss Date 2004-06-11 Time 10:26 Rev Time 0.25
Received By pkrauss Date 2004-06-11 Time 10:26 Sent To  
Notes
2004-06-11 00:00:00SUBMITTAL LETTER FROM GE FOR THE DRYER
 VENTING.

Review Stop M MECHANICAL (A/C)
Rev No 19 Status P Date 2004-05-06 Cont ID  
Sent By pkrauss Date 2004-05-06 Time 07:09 Rev Time 0.55
Received By pkrauss Date 2004-05-06 Time 07:09 Sent To  
Notes
2004-05-06 00:00:00SHOP DRAWINGS MECHANICAL RM LAYOUT.
 SEF-2 DAMPER
 SIDEWALL SUPPLY GRILLE W/DAMPER
 SHOP DRAWINGS DRYER DUCTWORK FOR 4TH,
 5TH & 6TH FLOORS

Review Stop M MECHANICAL (A/C)
Rev No 18 Status N Date 2004-04-13 Cont ID  
Sent By pkrauss Date 2004-04-13 Time 12:12 Rev Time 0.40
Received By pkrauss Date 2004-04-13 Time 12:12 Sent To  
Notes
2004-04-13 00:00:00SHOP DRAWINGS SUBMITTED FROM EAST COAST
 MECH. FOR THE CHILLED WATER LINES

Review Stop M MECHANICAL (A/C)
Rev No 17 Status P Date 2004-04-12 Cont ID  
Sent By pkrauss Date 2004-04-12 Time 12:34 Rev Time 1.25
Received By pkrauss Date 2004-04-12 Time 12:34 Sent To  
Notes
2004-04-12 00:00:00SUBMITTALS/SUPPLY FANS SF2-1 &
 SF2-2/POOL AC SYSTEM/ EXHAUST FAN FOR
 POWDER ROOM/AHU-1 THROUGH AHU-3 & OAU-1
 THROUGH OAU-5.

Review Stop M MECHANICAL (A/C)
Rev No 16 Status P Date 2004-03-02 Cont ID  
Sent By pkrauss Date 2004-03-02 Time 10:19 Rev Time 0.25
Received By pkrauss Date 2004-03-02 Time 10:19 Sent To  
Notes
2004-03-02 00:00:00SUBMITTAL - DUCTSOX FOR POOL AREA
 VALUE ENGINEERING / APPROVED BY H. MOSER

Review Stop M MECHANICAL (A/C)
Rev No 15 Status P Date 2004-02-24 Cont ID  
Sent By pkrauss Date 2004-02-24 Time 07:23 Rev Time 1.55
Received By pkrauss Date 2004-02-24 Time 06:33 Sent To  
Notes
2004-02-24 00:00:0013 SUBMITTALS:
 15C-13-15930-3 VAV BOXES; 15C-10-15515-2
 VENTURI; 15C-16-15686-3 WATER COOLED CHI
 LLERS; 15C-05-15540-2 SUCTION PUMPS SP1,
 SP2; 15C-03-15540-2 INLINE PUMPS CP4&5;
 15C-02-15540-2 BASE MOUNTED PUMPS CP1,2,
 3; 15C-59-15830-0 FCU-1; 15C-61-15100-0
 REFRIGERANT MONITORING & BREATHING
 APPARATUS; 15C-62-15686-0 REV SPLIT SYS
 DX/CU2; 15C-09-15515-2 SUCTION DIFFSER;
 15C-41-15830-2 FAN COIL UNITS A,B,C,D;
 15C-32-15910-2 DUCTWORK ACCESS;
 15C-36-15890-2 LOUVERS; 15C-45-15200-1
 PUMP INERTIA BASES

Review Stop M MECHANICAL (A/C)
Rev No 14 Status P Date 2004-02-05 Cont ID  
Sent By pkrauss Date 2004-02-05 Time 08:36 Rev Time 1.45
Received By pkrauss Date 2004-02-05 Time 07:06 Sent To  
Notes
2004-02-05 00:00:00PROVISO:
 SHOP DRAWINGS ARE TO BE SUBMITTED AS
 REVISIONS APPROVED BY THE ENGINEER OF
 RECORD.PLANS ARE TO BE SIGNED, SEALED,
 DATED, AND TITLE BLOCK REQUIRED PER FS
 471.025 & FAC 61G15-23.002 OR A SIGNED,
 SEALED & DATED LETTER BY THE ENGINEER
 REFERENCING THE SHOP DRAWINGS WILL BE
 ACCEPTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 13 Status P Date 2004-02-03 Cont ID  
Sent By pkrauss Date 2004-02-03 Time 06:52 Rev Time 0.33
Received By pkrauss Date 2004-02-03 Time 06:52 Sent To  
Notes
2004-02-03 00:00:00SUBMITTAL "SLIM LINE FIRE DAMPERS"

Review Stop M MECHANICAL (A/C)
Rev No 12 Status P Date 2004-01-28 Cont ID  
Sent By hmoser Date 2004-01-28 Time 18:06 Rev Time 0.50
Received By hmoser Date 2004-01-28 Time 18:06 Sent To  
Notes
2004-01-28 00:00:00SUBMITTALS FOR EXHAUEST RISER DIAGRAM
 (EAR 14.44 & MAR 9-33 SHOPS)

Review Stop M MECHANICAL (A/C)
Rev No 11 Status P Date 2004-01-28 Cont ID  
Sent By hmoser Date 2004-01-28 Time 17:45 Rev Time 1.50
Received By hmoser Date 2004-01-28 Time 17:44 Sent To  
Notes
2004-01-28 00:00:00SUBMITTAL FOR CHILLER ROOM (B-102 SHOPS)

Review Stop M MECHANICAL (A/C)
Rev No 10 Status P Date 2004-01-28 Cont ID  
Sent By pkrauss Date 2004-01-28 Time 07:08 Rev Time 0.45
Received By pkrauss Date 2004-01-28 Time 07:08 Sent To  
Notes
2004-01-28 00:00:00SUBMITTAL FOR THE FIRE STOPPING

Review Stop M MECHANICAL (A/C)
Rev No 9 Status P Date 2004-01-14 Cont ID  
Sent By pkrauss Date 2004-01-08 Time 11:16 Rev Time 1.25
Received By pkrauss Date 2004-01-08 Time 11:13 Sent To  
Notes
2004-01-08 00:00:00PROVISO:
 PLEASE NOTE FIRE DAMPERS ON THE MAKE UP
 AIR DUCTS INDICATED ON RISER DIAGRAM,
 PLEASE REFER TO SHEETS M-401, M-402, &
 M-403, APPROVED JULY 25, 2003.
  
 FIRE DAMPERS MAY BE REQUIRED ON DUCTS
 THAT PENETRATE RATED WALLS AND DO NOT
 COMPLY WITH THE EXCEPTIONS UNDER 2001
 FBC(M) 607.1.3 #3 ITEMS 1 THRU 4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 8 Status F Date 2003-12-05 Cont ID  
Sent By csiegber Date 2003-12-23 Time 11:34 Rev Time 0.45
Received By pkrauss Date 2003-12-05 Time 14:10 Sent To  
Notes
2003-12-05 00:00:00DENIED:
 PLEASE PROVIDE ADDITIONAL INFORMATION
 ON THE "DUCTSOX".
  
 1.SHEET 1 EQUIPMENT: DUCTSOX "EXPOSED
 IN POOL AREA".PLEASE REFERENCE PLAN
 SHEET # IN THE AREA THE PROPOSED DUCT IS
 TO BE USED.
  
 2.SUBMITTAL SHEET 3 INDICATES UL
 CLASSIFICATION, PROVIDE UL #.
  
 3.PROVIDE MAUFACTURER'S SUBMITTAL DATA
 AND INSTALLATION INSTRUCTIONS.

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2003-12-05 Cont ID  
Sent By pkrauss Date 2003-12-05 Time 12:37 Rev Time 0.55
Received By pkrauss Date 2003-12-05 Time 12:36 Sent To  
Notes
2003-12-05 00:00:00SUBMITTALS:
 STAINLESS STEEL FLEX CONNECTORS
 GRILLES/DIFFUSERS/REGISTERS

Review Stop M MECHANICAL (A/C)
Rev No 6 Status N Date 2003-11-04 Cont ID  
Sent By pkrauss Date 2003-11-04 Time 15:49 Rev Time 0.11
Received By pkrauss Date 2003-11-04 Time 15:45 Sent To  
Notes
2003-11-04 00:00:00SHOP DRAWING SUBMITTALS ON THE KITCHEN
 EQUIPMENT (SINK, COUNTER, SHELVES) NO
 HOOD.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2003-09-25 Cont ID  
Sent By pkrauss Date 2003-09-25 Time 11:52 Rev Time 0.40
Received By pkrauss Date 2003-09-25 Time 11:52 Sent To  
Notes
2003-09-25 00:00:00SUBMITTALS: AUTOMATIC AIR VENT,
 EXPANSION TANK, AIR SEPARATOR, AIR
 COOLED CONDENSING UNITS (CU 2-1/CU 2-2).

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2003-07-11 Cont ID  
Sent By pkrauss Date 2003-07-11 Time 14:19 Rev Time 0.40
Received By pkrauss Date 2003-07-11 Time 14:18 Sent To  
Notes
2003-07-11 00:00:00PROVISO:
  
 ADDITIONAL PERMITS REQUIRED FOR HOOD,
 FIRE SUPPRESSION AND WALK-IN COOLERS.
 PLEASE PROVIDE PLANS AND MANUFACTURER
 SUBMITTAL DATA/INSTALLATION INSTRUCTIONS
 WITH PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2003-06-06 Cont ID  
Sent By pkrauss Date 2003-06-06 Time 10:55 Rev Time 5.00
Received By pkrauss Date 2003-05-27 Time 08:41 Sent To  
Notes
2003-06-06 00:00:00DENIED:
  
 1.RESPONSE TO COMMENT #3 - REFERENCED
 RANGE HOODS ARE FOR RESIDENTIAL.
 ADDITIONAL PERMIT WILL BE REQUIRED FOR
 THE MAIN KITCHEN HOOD, FIRE SUPPRESSION
 AND WALK-IN COOLERS.ADDITIONAL PERMIT
 NOT REQUIRED FOR THE RESIDENTIAL HOODS.
  
 2.RESPONSE TO COMMENT #8 - SEQUENCE
 OF OPERATION FOR THE ATRIUM SMOKE STATES
 ACTIVATION UPON DETECTION OF THE SMOKE
 DETECTOR.ACTIVATION SHOULD TAKE PLACE
 UPON ANY FIRE ALARM DEVICE.
  
 3.TEST AND BALANCE DOES NOT REQUIRE
 THE CITY TO WITNESS THE BALANCING
 PROCESS.WE DO REQUIRE THE CONTRACTOR
 BE CERTIFIED TO PERFORM THE TEST AND
 BALANCE AND SUBMIT THE RESULTS TO THE
 CHIEF MECHANICAL INSPECTOR.
  
 4.RESPONSE TO COMMENT #10 - JLSD WILL
 NOT REQUIRE SMOKE TEST TO BE PERFORMED.
 THE CITY REQUIRES THE MECHANICAL & FIRE
 DEPARTMENT INSPECTORS TO WITNESS THE
 TEST.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-04-11 Cont ID  
Sent By pkrauss Date 2003-04-11 Time 10:59 Rev Time 7.00
Received By pkrauss Date 2003-04-11 Time 10:58 Sent To  
Notes
2003-04-11 00:00:001.PLAN SHEET M-102 NOTE #4, "SEE
 M-200" THIS SHEET WAS NOT SUBMITTED.
 NOTE #6 "SEE DIVISION 16 SERIES DWG",
 PLEASE CLARIFY.
  
 2.PLAN SHEET M-101, ATRIUM SMOKE
 CONTROL - CODE SECTION 403.6.6.1, SHOULD
 THIS READ 414.4.2.
  
 3.PLAN SHEET M-202, PLAN NOTE #4
 "RANGE HOOD BY OTHERS" - SEPARATE PLANS
 AND PERMITS REQUIRED FOR HOOD, FIRE
 SUPPRESSION AND WALK-IN COOLERS.
  
 4.PLAN SHEET M-203, HOOD CONNECTION
 TRANSITION DUCTWORK COMMENTS 1,2,& 11,
 INDICATE GREASE DUCT CLEARANCE TO
 COMBUSTIBLES, WILL DUCT BE IN A SHAFT,
 OR WILL FIREWRAP BE USED?
  
 5.M-203, DUCT PENETRATIONS INTO AHU
 ROOM A135 NO FIRE DAMPERS INDICATED.
  
 6.MULTIPLE FLOORS HAVE "STORAGE &
 ELECTRICAL" ROOMS THAT HAVE A 1 HOUR
 FIRE RESISTANCE RATING.THE MECHANICAL
 PLANS CALL FOR UNDERCUT DOOR FOR AIR
 MAKE UP.PLEASE CLARIFY HOW THE RATING
 IS MET WITH THE DOOR UNDERCUT.
  
 7.PLEASE NOTE, DEVELOPED LENGTH FOR
 DRYER DUCTS SHALL NOT EXCEED 25 FT. WITH
 A 5 FT REDUCTION FOR EACH 90 DEGREE
 RADIUS AND A 2 1/2 FT. REDUCTION FOR
 EACH 45 DEGREE RAD.
  
 PROVIDE TEST CRITERIA FOR THE SMOKE
 CONTROL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-07-09 Cont ID  
Sent By ndenmark Date 2002-07-09 Time 12:34 Rev Time 5.00
Received By ndenmark Date 2002-07-09 Time 12:34 Sent To  
Notes
2002-07-09 00:00:00DENIED:
 1. NO FIRE DAMPERS ARE SHOWN AT RATED
 WALLS. 2001 FBC(M) 607.6 THE SPECIFIC
 LOCATION AND INSTALLATION DETAILS OF
 EACH FIRE DOOR, FIRE DAMPER, CEILING
 DAMPER AND SMOKE DAMPER SHALL BE SHOWN
 AND PROPERLY INDENTIFIED ON THE
 BUILDING PLANS BY THE DESIGNER.
  
 2. PROVIDE SHAFT DETAILS FOR EXHAUST
 RISERS.
  
 3. PROVIDE DETAILS ON DRYER DUCTS.
  
 4. SHOW SEQUENCE OF OPERATION FOR ATRIUM
 SMOKE EVAC AND CALCULATIONS OF AIR
 FLOW.
  
 5. CHILLER ROOM REFRIGERANT RELIEF PIPE
 TO COMPLY WITH 2001 FBC(M) 1105.9
 PUSH BUTTON SILENCE ON REFRIGERANT
 LEAK DETECTOR MODULE SHALL NOT BE
 AVAILABLE.
 HORN AND STROBE SHALL BE VISIBLE AND
 AUDIBLE THOUGHOUT ENTIRE ROOM WITH
 EQUIPMENT RUNNING.
 SIGN IN NOTE 22 TO BE BY EVERY DOOR
 INTO CHILLER ROOM.
 BREATHING APPERATUS TO BE CLOSE TO
 MAIN ACCESS DOOR.
 SET POINT FOR ALARM AND EMERGENCY
 VENTILATION SHALL BE MINIMUM 1000PPM
 PER TABLE 1103.1
 IS THE REFRIGERANT PURGE EXHAUST
 FAN TO RUN CONTINUOUSLY?
  
 6. SEE 2001 FBC(M) 1206.1.1 FOR
 PROHIBITED TEE APPLICATIONS. "FLUID IN
 THE SUPPLY SIDE OF A HYDRONIC SYSTEM
 SHALL NOT ENTER A TEE FITTING THROUGH
 THE BRANCH OPENING."
  
 7. FLORIDA ENERGY CODE REQUIRES MINIMUM
 IPLV NOT SHOWN AS NPLV. PLEASE PROVIDE
 IPLV SHOWING COMPLIANCE WITH TABLE 4-5
  
 8. ROOF MOUNTED EQUIPMENT SUPPORTS
 HEIGHT IS BASED ON EQUIPMENT WIDTH PER
 TABLE 1511.7 2001 FBC.
  
 9. THE PLANS PROVIDED ARE NOT A COMPLETE
 SET AND FOLLOWING REVIEWS COULD REFLECT
 COMMENTS ON ITEMS NOT APPARENT UNDER
 THIS INCOMPLETE PLAN SET.
 PLANS ARE REQUIRED TO BE SIGNED AND
 SEALED BY THE DESIGNER.

Review Stop P PLUMBING
Rev No 26 Status P Date 2004-12-22 Cont ID  
Sent By kstevens Date 2004-12-22 Time 16:16 Rev Time 2.50
Received By kstevens Date 2004-12-22 Time 16:16 Sent To  
Notes
2004-12-22 00:00:00REVISION OK - ADDED 2" COPPER GAS LINE
 TO TWO POOL HEATERS. APPROX 200' - LESS
 THAN TOTAL DEV. LENGTH

Review Stop P PLUMBING
Rev No 25 Status F Date 2004-12-09 Cont ID  
Sent By kstevens Date 2004-12-09 Time 14:43 Rev Time 0.50
Received By kstevens Date 2004-12-09 Time 14:43 Sent To  
Notes
2004-12-09 00:00:00DENIED
 REFERENCE: FBC-2001 FUEL GAS
  
 SHT P202 NEW GAS LINE TO POOL HEATERS.
 SEE ATTACHED SHEET FOR GAS REVIEW.
 SUBMIT INFORMATION REQUIRED FOR ALL BUT
 NUMBERS 4, 10, 11, AND 12.
  
 CIRCULATION LINE NOT CLOUDED AND SHOWN
 AS PART OF THE REVISION. SECTION
 104.2.1
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 24 Status P Date 2004-12-09 Cont ID  
Sent By kstevens Date 2004-12-09 Time 14:42 Rev Time 1.50
Received By kstevens Date 2004-12-09 Time 14:42 Sent To  
Notes
2004-12-09 00:00:00REVISION OK SHTS P201, P203, P205

Review Stop P PLUMBING
Rev No 23 Status P Date 2004-06-08 Cont ID  
Sent By jleech Date 2004-06-08 Time 20:27 Rev Time 0.50
Received By jleech Date 2004-06-08 Time 20:27 Sent To  
Notes
2004-06-08 00:00:00SUBMITALS FORCHANNEL DRAINS.

Review Stop P PLUMBING
Rev No 22 Status P Date 2004-03-20 Cont ID  
Sent By kstevens Date 2004-03-20 Time 08:51 Rev Time 0.75
Received By kstevens Date 2004-03-20 Time 08:51 Sent To  
Notes
2004-03-20 00:00:00SUBMITTALS - GAS BOOSTER HEATER FOR D.W.
 OK - WATER FILTER DENIED - NOT NSF-42
 LISTED

Review Stop P PLUMBING
Rev No 21 Status P Date 2004-03-18 Cont ID  
Sent By kstevens Date 2004-03-18 Time 16:07 Rev Time 1.50
Received By kstevens Date 2004-03-18 Time 16:07 Sent To  
Notes
2004-03-18 00:00:00SUBMITTAL OK - GAS APPLIANCE MANUF.
 SHEETS - LISTING INFORMATION

Review Stop P PLUMBING
Rev No 20 Status P Date 2004-03-17 Cont ID  
Sent By kstevens Date 2004-03-17 Time 10:03 Rev Time 0.00
Received By kstevens Date 2004-03-17 Time 10:03 Sent To  
Notes
2004-03-17 00:00:00REVISION OK - CHANGED PIPE SIZE ON GAS
 RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 19 Status P Date 2004-03-09 Cont ID  
Sent By kstevens Date 2004-03-09 Time 17:51 Rev Time 1.00
Received By kstevens Date 2004-03-09 Time 17:51 Sent To  
Notes
2004-03-09 00:00:00SUBMITTALS OK - DOMESTIC WATER BOOSTER
 PUMP PACKAGE

Review Stop P PLUMBING
Rev No 18 Status P Date 2004-01-26 Cont ID  
Sent By kstevens Date 2004-01-26 Time 16:49 Rev Time 2.00
Received By kstevens Date 2004-01-26 Time 16:49 Sent To  
Notes
2004-01-26 00:00:00SUBMITTALS OF PRODUCT DATA APPROVED EX-
 CEPT FOR THE FOLLOWING ITEMS.
 #18 NOT SUBMITTED
 #54A NOT SUBMITTED
 #58 NEED LISTING FOR GAS
 #104A NOT SUBMITTED
 #106 NEED LISTING FOR GAS
 #107 NEED LISTING FOR GAS
 #107A TO BE NSF APPROVED
 #145A NOT SUBMITTED
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 17 Status P Date 2004-01-26 Cont ID  
Sent By kstevens Date 2004-01-26 Time 16:48 Rev Time 1.25
Received By kstevens Date 2004-01-26 Time 16:48 Sent To  
Notes
2004-01-26 00:00:00SUBMITTALS OF PLUMBING FIXTURES OK

Review Stop P PLUMBING
Rev No 16 Status P Date 2004-01-26 Cont ID  
Sent By kstevens Date 2004-01-26 Time 13:27 Rev Time 1.00
Received By kstevens Date 2004-01-26 Time 13:26 Sent To  
Notes
2004-01-26 00:00:00SUBMITTALS OK - IRRIGATION SYSTEM

Review Stop P PLUMBING
Rev No 15 Status P Date 2004-01-24 Cont ID  
Sent By kstevens Date 2004-01-24 Time 13:29 Rev Time 0.25
Received By kstevens Date 2004-01-24 Time 13:29 Sent To  
Notes
2004-01-24 00:00:00SUBMITTAL OK - ROOF DRAIN EXTENSIONS

Review Stop P PLUMBING
Rev No 14 Status P Date 2004-01-10 Cont ID  
Sent By kstevens Date 2004-01-10 Time 09:33 Rev Time 1.50
Received By kstevens Date 2004-01-10 Time 09:33 Sent To  
Notes
2004-01-10 00:00:00SUBMITTALS OK - STORM WATER SYSTEMS -
 SOIL, WASTE & VENT SYSTEM - KITCHEN SINK
 - PLUMBING SPECIALTIES - ALL PLUMBING
 FIXTURES, WITH STOPS, TRAPS, VALVES ECT.
 EXCEPT FOR THE ACCESSIBLE SHOWERS.

Review Stop P PLUMBING
Rev No 13 Status F Date 2004-01-08 Cont ID  
Sent By kstevens Date 2004-01-08 Time 09:08 Rev Time 2.50
Received By kstevens Date 2004-01-08 Time 09:07 Sent To  
Notes
2004-01-08 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHTS P207, P208, P217, & P218 ALL
 SHOW 2" CONDENSATE RISER WITH A 2" HUB
 DRAIN, BUT SHOW 3" PIPED TO THE HUB
 DRAIN. PLEASE CLAIRFY.
 2) SHT P-402 SANITARY RISERS B/9 & B/25
 JANITOR SINK HAS BEEN ADDED TO RISERS.
 PER SECTION 909.1, ONLY THE FIXTURES
 WITHIN THE BATHROOM GROUP SHALL CONNECT
 TO THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. ANY ADDITIONAL FIXTURES SHALL
 DISCHARGE DOWNSTREAM OF THE WET VENT.
 3) SHT P-407 SANITARY RISER B/50 TRAP
 REQUIRED ON FIXTURE T-1 (TUB) 1002.1
 4) SHT P-407WATER RISERS 'A' & 'B' NO
 CHANGES WERE NOTED BUT RISERS WERE
 CLOUDED. WATER RISER 'A' REQUIRES FULL
 OPEN VALVES PER 606.1(4) AS INDICATED ON
 STAMPED SET OF PLANS. ALSO WASH MACHINE
 REQUIRES WATER HAMMER ARRESTORS NEAR THE
 FIXTURE. 604.9
 5) INFORMATIONAL - SHTS P-103 AND P-410
 REQUIRE REVISIONS PER STAMPED SET OF
 PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 12 Status F Date 2003-12-18 Cont ID  
Sent By kstevens Date 2003-12-18 Time 10:10 Rev Time 1.50
Received By kstevens Date 2003-12-18 Time 10:10 Sent To  
Notes
2003-12-18 00:00:00SUBMITTAL DENIED
  
 SUBMIT LISTING FROM AN APPROVED TESTING
 AGENCY FOR ANCHORS INDICATED IN SUBMITT-
 ALS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 11 Status P Date 2003-12-01 Cont ID  
Sent By kstevens Date 2003-12-01 Time 10:04 Rev Time 1.50
Received By kstevens Date 2003-12-01 Time 10:04 Sent To  
Notes
2003-12-01 00:00:00SUBMITTAL OK - LAV REVISION - CRANE 1412
 UNDERCOUNTER LAV & ALT. FAUCET - CRANE
 1992 - ZURN Z-831R1-P - BACKWATER VALVES

Review Stop P PLUMBING
Rev No 10 Status P Date 2003-10-25 Cont ID  
Sent By kstevens Date 2003-10-25 Time 15:24 Rev Time 0.33
Received By kstevens Date 2003-10-25 Time 15:24 Sent To  
Notes
2003-10-25 00:00:00SUBMITTAL FOR KITCHEN TABLES SINKS ECT

Review Stop P PLUMBING
Rev No 9 Status P Date 2003-10-14 Cont ID  
Sent By kstevens Date 2003-10-14 Time 11:56 Rev Time 0.50
Received By kstevens Date 2003-10-14 Time 11:56 Sent To  
Notes
2003-10-14 00:00:00SUBMITTAL FOR WATER HEATERS OK

Review Stop P PLUMBING
Rev No 8 Status F Date 2003-10-14 Cont ID  
Sent By kstevens Date 2003-10-14 Time 09:54 Rev Time 0.33
Received By kstevens Date 2003-10-14 Time 09:54 Sent To  
Notes
2003-10-14 00:00:00SUBMITTAL FOR STORM WATER SYSTEMS DENIED
 CLEAR CLEANER CALL FOR IN SUBMITTAL. -
 SECTION 105.12.2, PURPLE PRIMER REQUIRED
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 7 Status F Date 2003-10-14 Cont ID  
Sent By kstevens Date 2003-10-14 Time 09:48 Rev Time 0.33
Received By kstevens Date 2003-10-14 Time 09:48 Sent To  
Notes
2003-10-14 00:00:00SUBMITTAL DENIED - SUBMITTAL CALLS FOR
 CLEAR CLEANER FOR PVC. SECTION 705.12.2
 A PURPLE PRIMER IS REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 6 Status P Date 2003-10-11 Cont ID  
Sent By kstevens Date 2003-10-11 Time 12:53 Rev Time 0.33
Received By kstevens Date 2003-10-11 Time 12:52 Sent To  
Notes
2003-10-11 00:00:00SUBMITTAL OK - INSULATION FOR PIPING -
 2 COPIES TO CONTRACTOR - 1 COPY TO DON
 NEELY.
 SUBMITTAL OK - PIPING INSULATION - ONE
 COPY TO DON NEELY - TWO COPIES TO THE
 CONTRACTOR.

Review Stop P PLUMBING
Rev No 5 Status P Date 2003-07-25 Cont ID  
Sent By csiegber Date 2003-10-02 Time 08:14 Rev Time 3.00
Received By kstevens Date 2003-07-25 Time 18:49 Sent To  
Notes
2003-07-25 00:00:00PASSED/PROVISO
  
 SHT P-103 LOCKER ROOM SANITARY/VENT
 RISER, HORIZONTAL DRY VENT NOT APPROVED.
 WATER CLOSET SHALL TIE IN ON THE VERTIC-
 AL RISE. SECTION 905.3- REVISION REQD.
  
 SHT P-301 VALVES REQUIRED ON WATER RISER
 SECTION 606.1(4)
 SHT P-407 VALVES REQUIRED ON WATER RISER
 SECTION 606.1(4)
  
 SHT P-409 VENTS AND LAV ARM NOT SHOWN ON
 RISER "B" REVISION REQUIRED.
  
  
 --GAS PERMIT APPLICATION REQUIREMENTS---
 WELDER'S CERTIFICATION, PICTURE I.D. AND
 WELDING PROCEDURE REQUIRED PRIOR TO
 ISSUING OF GAS PERMIT.
 WELDING INSPECTIONS REQUIRED: TACK-UP,
 ROOT PASS, FILLER PASS. COVER PASS CAN
 BE INSPECTED AT TIME OF ROUGH INSPECTION
 SHUT OFF VALVES UPSTREAM OF REGULATORS
 REQUIRED AT EACH GAS FIXTURE. UNION RE-
 QUIRED DOWNSTREAM OF REGULATOR. PIPE
 SIZES TO BE CORRECTED AT 750,000 BTU
 HEATERS. 2" REQUIRED. PIPE SIZES NOT
 SHOWN ADJACENT TO METER. SUBMIT A REVIS-
 ED GAS RISER WITH THESE CORRECTIONS WITH
 GAS APPLICATION.
 MANUFACTURE CUT SHEET REQUIRED FOR THE
 REGULATORS, DISHWASHER, UDS EQUIPMENT.
 CUT SHEETS FOR GAS APPLIANCES SHALL SHOW
 A LISTING BY AN APPROVED AGENCY AND BTU
 LOAD FOR EACH APPLIANCE. (LOCHIVAR UNITS
 DO NOT SHOW A LISTING)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 4 Status F Date 2003-07-16 Cont ID  
Sent By kstevens Date 2003-07-16 Time 18:19 Rev Time 17.50
Received By kstevens Date 2003-07-16 Time 18:14 Sent To  
Notes
2003-07-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
 FBC-2001 BUILDING
 FBC-2001 FUEL GAS
 FHA-AMEND 98 DESIGN MANUAL
  
 1) SHTS A2.02A, A-2.03A, & A-2.3, THE
 VERANDA ROOF DRAINS SHOW NO PIPING. IN-
 DICATE HOW THE RAIN WATER WILL BE DRAIN-
 ED OFF THIS ROOF AND WHERE IT WILL TER-
 MINATE. ALSO THERE APPEARS TO BE A PARA-
 PET WALL THAT WILL NEED A SCUPPER. IF SO
 PLEASE SHOW WHERE THE SCUPPER WILL BE
 LOCATED AND INDICATE THE SIZE.
 2) SHT P-409 DOES NOT REFLECT THE FLOOR
 PLAN. IN WOMEN'S LOCKER ROOM THE FLOOR
 PLAN SHOWS A WATER CLOSET, LAV IN STALL,
 THEN TWO MORE WATER CLOSETS, AND THEN
 THE DRINKING FOUNTAIN IN THE CORRIDOR.
 THE RISER DIAGRAM SHOWS TWO 4" LINES FOR
 W/C'S THEN THREE 2" LINES PRIOR TO THE
 DRINKING FOUNTAIN. ALSO 8" REQUIREDON
 SANITARY BY NEW CLEANOUT AS SHOWN IN
 PREVIOUS COMMENT.
 3) SHT P-410 SEWER "G" 2 LINES SHOWN FOR
 RISERS B/15 & KS/33 ON FLOOR PLAN BUT
 ONLY ONE SHOWN ON RISER DIAGRAM.
 SEWER "F" KS/31 MISSING
 FROM RISER DIAGRAM.
 SEWER "H" VENT REQUIRED
 PRIOR TO FIRST FLOOR DRAIN. - PER TABLE
 906.1 TRAP SHALL BE MAXIMUM OF 12' FROM
 VENT, 4" HUB DRAIN IS APPROX. 16'. ALSO
 RISERS B/49, B/57, B-51, B/52, KS/32, &
 KS/33 NOT ON FLOOR PLAN.
 SEWER "F" RISER W/22 NOT
 FOUND WITH OTHER RISERS. SUBMIT RISER.
 FIXTURE UNITS/PIPE SIZE NOT CORRECT AS
 INDICATED IN PREVIOUS REVIEW.
 SEWER "D" PIPE SIZE FOR
 4,970 S.F. REQUIRES 8" PIPE. 6" SHOWN.
 PIPE SIZE FOR 783 S.F. REQUIRES 4" PIPE
 ON THE HORIZONTAL. 3" SHOWN.
 PIPE SIZE FOR 778 S.F. REQUIRES 4" PIPE
 ON THE HORIZONTAL. 3" SHOWN.
 4) SHTS P-202 & P-405 - 6" HUB DRAIN
 SHOWN TO BOTH SANITARY AND TO STORM.
 DELETE FROM SANITARY SYSTEM ON BOTH
 SHEETS.
 5) SHT P-202 NO SANITARY TO LAV IN HDCP
 STALL MEN'S LOCKER ROOM.
 6) SHT P-203 OVERFLOW FROM THE COOLING
 TOWER SHALL DRAIN TO STORM. THE COOLING
 TOWER SHALL DRAIN TO SANITARY.
 7) PLANS HAVE NOT BEEN ROUTED TO THE
 PALM BEACH HEALTH UNIT. THIS SHALL BE
 DONE PRIOR TO ISSUING A PERMIT.
 8) SHTS A-2.14, A-2.42, & A-2.43 MANUF.
 INFORMATION REQUIRED FOR SHOWERS TO
 VERIFY COMPLIANCE WITH HEIGHT OF GRAB
 BARS PER FHA DESIGN MANUAL.
 9) SHT A-8.11 TOILET ROOM DOORS SHALL
 NOT OPEN INTO THE CLEAR FLOOR SPACE OF
 THE TURNING RADIUS. SEC 11-4.22.2
 10 SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 ONLY WATER HEATER SHEETS SUBMITTED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-06-07 Cont ID  
Sent By kstevens Date 2003-06-07 Time 09:59 Rev Time 12.00
Received By kstevens Date 2003-06-07 Time 09:59 Sent To  
Notes
2003-06-07 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 BUILDING
 FHA-AMEND 98 DESIGN MANUAL
  
 1) FROM PREVIOUS REVIEW: SUBMIT CALCUL-
 ATIONS FOR PRIMARY AND SECONDARY ROOF
 DRAINS. INCLUDE 1/2 AREA OF ALL VERTICAL
 WALLS, (INCLUDING PARAPETS), AND AREA OF
 ROOFS THAT DRAIN DOWN FROM ABOVE. EACH
 AREA IS AFFECTED BY VERTICAL WALLS, AND
 SOME ARE AFFECTED BY ADDITIONAL AREA OF
 ROOF THAT DRAIN FROM ABOVE, I.E. STAIR
 ROOFS, MECHANICAL ROOM ROOFS, ECT.
 PLEASE CALCULATE EACH AREA WITH ALL IN-
 FORMATION REQUESTED INCLUDED. ALSO IN-
 DICATE HOW INTERNAL AREAS OF THE ROOF,
 (WITH OUT SCUPPERS), IMPACT AREAS AROUND
 THEM AS FAR AS SIZING SCUPPERS. SHOW
 CALCULATIONS FOR SIZING SCUPPERS IN
 SURROUNDING AREAS. 1106/107
 2) SHTS P-407, & P408 STORM WATER RISER
 ISOMETRIC. SOME PIPE SIZING IS NOT CORR-
 ECT. PIPE SIZED FOR VERTICAL RISER, BUT
 HAS HORIZONTAL OFFSET THAT NEED TO BE
 SIZED FOR HORIZONTAL. (SEE RED LINE
 COMMENTS ON SHEETS). ALSO SEE PREVIOUS
 COMMENT PRIOR TO ADJUSTING PIPE SIZE.
 TABLE 1106.3
 3) SHTS P409, & P410 SANITARY RISER DIA-
 GRAM DOES NOT REFLECT THE FLOOR PLAN.
 SOME PIPING IS NOT SIZED CORRECTLY.
 SOME CLEANOUTS NOT SHOWN. RECHECK THE
 FIXTURE UNIT ADDITION. TABLE 710.1(1)
 4) SHT P-202 STORM WATER PIPING DOES NOT
 MATCH LEGEND SHT P-101. 104.2.1
 5) SHT P-202 PLEASE INDICATE WHAT WILL
 BE DRAINING INTO 6" H.D. IN POOL/MECH.
 ROOM #C161. (POOL DRAIN/OVERFLOW TO STOR
 M, AND WASTE FROM POOL TO SANITARY.)
 SEC 104.2.1
 6) SHT P-201 INDICATE TYPE OF BUSINESS
 IN BISTRO SERVERY. WILL FOOD BE PREPARED
 OR SERVED?SEC 104.2.1
 7) SHT P-201 MENS TOILET ROOM, (C166), &
 WOMENS TOILET ROOM, (C165). NO SANITARY
 PIPING SHOWN FOR LAVS IN HDCP STALLS.
 SECTION 104.2.1
 8) SHT P-409 BLDG. DRAIN ISOMETRIC,
 SHOWS BLDG. DRAIN "B" DRAINING INTO BLDG
 DRAIN "D", FUT FLOOR PLAN SHT P-202
 SHOWS "B" DRAINING TO "F". PLEASE CLAIR-
 FY.SEC 104.2.1
 9) SHT P-203 NO SANITARY DRAINAGE PIPING
 TO ICE BIN #130, AND WORK COUNTER SINK
 #129. PLEASE CLAIRFY. SEC 104.2.1
 10) SHT P-410 BLDG DRAIN ISO "G" IS NOT
 COMPLETE. MISSING RISERS B/49, B/57,
 B/51, B/52, KS/32, & KS/33. SEC 104.2.1
 11) SHTS P-410, P-202, & P-203,CLEANOUTS
 REQUIRED PER SECTION 708.3.3. PLEASE
 SHOW ON FLOOR PLAN AND ISOMETRIC.
 12) SHTS P-409 & P-410, COMPLETE RISER
 REQUIRED FOR 1ST FLOOR BLDG DRAIN. FOR
 AN EXAMPLE BLDG DRAIN "H" SHOW ALL FIX-
 TURES ON RISER DIAGRAM. SOME AREAS JUST
 HAVE A LINE WITH FIXTURE UNITS BUT DO
 NOT SHOW FIXTURES.SEC 104.2.1
 13) SHT P-203 PLEASE INDICATE WHAT WILL
 BE DRAINED INTO 4" H.D. IN COOLING TOWER
 ENCLOSURE.SEC 104.2.1
 14) SHT P-402 SANITARY RISER DIAGRAM
 #B/9 DOES NOT REFLECT THE FLOOR PLAN.
 PLEASE CLAIRFY.SEC 104.2.1
 15) SHT P-403 RISERS B/17 & B/18 START
 ON 1ST FLOOR SHT P-201, BUT DO NOT SHOW
 UP ON SHT P-207, (B/17), SHT P-210, BOTH
 SHT P-213, BOTH, AND SHT P-215, BOTH.
 PLEASE CLAIRFY. SEC 104.2.1
 16) SHT P-406 SANT RISER B/19 SHOWN ON
 1ST FLOOR OF SHT P-201 & P-207, BUT NOT
 FOUND ON SHTS P-210, P-213, P-215, OR
 P-217. FLOOR PLAN DOES NOT REFLECT THIS
 RISER OR THE FIXTURES CALLED FOR ON THE
 RESER. ALSO THERE IS ONLY A W/C SHOWN ON
 THE THIRD FLOOR OF RISER. SEC 104.2.1
 17) SHT P-406 RISER B/29 MISSING VENT
 FOR 2ND FLOOR. SEC 104.2.1
 18) SHT P-409 BLDG DRAIN ISOMETRIC DOES
 NOT REFLECT THE FLOOR PLAN. ISO SHOWS
 RISER W/10, AND FLOOR PLAN SHOWS B/19.
 PLEASE CLAIRFY.SEC 104.2.1
 THE FOLLOWING ITEMS HAVE NOT BEEN
 ADDRESSED. SEE ATTACHES SHEET REFERENC-
 ING FLORIDA STATUTE 553.80(2)(B). THIS
 WAS THE THIRD REVIEW.
 19) PLANS SHALL BE ROUTED TO THE PLAM
 BEACH HEALTH UNIT. THIS SHALL BE DONE
 PRIOR TO RESUBMITTING TO THE CITY FOR
 REVIEW.SEC 101.4.7
 20) SHTS A-2.41, A-2.42, & A-2.43. NO
 MEASURMENTS FOR BACKING SHOWN ON PLANS.
 (FHA DESIGN MANUAL REQUIREMENT #6)
 SPECIFICATION "A" OR "B" HAS NOT BEEN
 INDICATED. (FHA DESIGN MANUAL REQUIRE-
 MENT 7B). W/C OPENINGS NOT SHOWN. (FHA
 DISIGN MANUAL 7B. SEC 104.2.1
 21) SHT A-8.11 TURNING CIRCLE NOT SHOWN
 FOR PUBLIC AND COMMON USE TOILET/BATHING
 ROOMS. 11-4.22.3SEC 104.2.1
 22) SHT A-8.13 ELEVETIONS 8B, 8C, & 8D
 DO NOT MATCH INDICATOR ON DETAIL #1 SHT
 A-2.41SEC 104.2.1
 23) THE PERSONAL SEAL, SIGNATURE AND THE
 DATE OF THE ARCHITECT SHALL APPEAR ON
 ALL ARCHITECTURAL DOCUMENTS TO BE FILED
 FOR PUBLIC RECORD. NO DATES APPEAR ON
 THE SEAL.61G1-16.003
 24) SUBMIT MANUF SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH THE
 FBC-2001 FUEL GAS CODE SEC 402.2. THE
 WATER HEATER HEATER SHEETS WERE SUBMITT-
 ED, BUT NOT THE REST OF THE EQUIPMENT.
 *********WHEN RESUBMITTING PLANS********
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-03-22 Cont ID  
Sent By kstevens Date 2003-03-21 Time 17:58 Rev Time 7.00
Received By kstevens Date 2003-03-21 Time 17:57 Sent To  
Notes
2003-03-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 11
 FBC-2001 FHA-98 DESIGN MANUAL
  
 1) MOST OF THE FOLLOWING COMMENTS WERE
 FROM THE PREVIOUS PLAN REVIEW AND WERE
 NOT ADDRESSED.
 2) PLANS SHALL BE ROUTED TO THE PALM
 BEACH HEALTH UNIT.
 3) GREASE TRAP SHALL BE SIZED BY UTILITY
 DEPT. CONTACT R. COMPO (561) 837-4074.
 4) SHT A-2.31 SUBMIT CALCULATIONS FOR
 PRIMARY AND SECONDARY ROOF DRAINS. IN-
 CLUDE 1/2 AREA OF ALL VERTICAL WALLS,
 AND AREA OF ROOFS DRAINING ON TO ROOF
 FROM ABOVE.
 5) SUBMIT A HORIZONTAL STORM BLDG DRAIN.
 SHOW ALL RISERS AS THEY TIE INTO STORM
 DRAIN AS SHOW SQUARE FOOTAGE AS IT ACCU-
 MULATES IN SYSTEM.
 6) SHTS A-2.41, A-2.42, & A-2.43, NO
 MEASUREMENTS FOR BACKING SHOWN ON PLANS.
 SPECIFICATION "A" OR "B" ARE NOT SHOWN
 AS REQUIRED IN REQ. #7. W/C OPENING NOT
 SHOWN AS REQUESTED.
 7) SHT A-8.11 TURNING CIRCLE NOT SHOWN
 IN EACH TOILET ROOM AS REQUIRED.
 8) SHT A-8.13 ELEVATIONS 8B, 8C, & 8D DO
 NOT MATCH INDICATOR ON DETAIL #1 SHT.
 A-2.41
 9) SHT P-102 WATER HEATER "A" DETAIL,
 COMBUSTION AIR INTAKE SHALL BE SIZED AND
 INSTALLED PER MANUF. INSTALL. INSTRUCTS.
 PROVIDE INFORMATION FOR REVIEW.
 10) SHTS P-103 & P-404 WATER RISERS,
 WATER HAMMER ARRESTORS SHALL BE LOCATED
 NEAR THE FIXTURES IN AN EFFECTIVE RANGE,
 NOT IN CEILING. PER PDI-WH 201 AND MANUF
 INSTALL. INSTRUCTIONS.
 11) SHTS P-103, P-202, & P-404, VENTS
 ARE REQUIRED FOR SHOWERS IN MENS & WO-
 MENS LOCKER ROOMS.
 12) SHT P-201 SANITARY DRAINAGE PIPE
 (BURIED) DOES NOT MATCH LEDGEND ON SHT
 P-101. (ALSO SHT P-202)
 13) SHT P-202 CLEAN OUTS REQUIRED IN
 SANITARY BLDG. DRAIN. MAX. 100'.
 14) SUBMIT A SANITARY BLDG DRAIN. SHOW
 PIPE SIZES, CLEANOUTS, RISERS, AND SHOW
 FIXTURE UNITS AS THEY ACCUMULATE IN THE
 BLDG DRAIN.
 15) SHT P-202 ITEM P-145 FILTER TO BE
 NSF APPROVED. PROVIDE MANUF. INFORMATION
 16) SHTS P-202/P-203, ITEMS P-125, AND
 P-124, FUNNEL DRAINS NOT APPROVED. ALL
 INDIRECT WASTE SHALL DRAIN INTO FLOOR
 SINKS. SEC 802.3
 17) SHT P-207 STACK B/19 NOT FOUND.
 PLEASE CLAIRFY. ROOM C220
 18) SHT P-207 STACK KS/9 IN MIDDLE OF
 ROOM? NO WATER TO KITCHEN SINK. RM C220
 19) SHTS P-216 & P-218, SIZE WATER MAINS
 OVERHEAD IN CORRIDOR.
 20) SHT P-301 SHOW PIPE SIZES FOR RISER
 "A".
 21) SHT P-401 SHOW PIPE SIZES FOR WATER
 MAINS IN KITCHEN CEILING.
 22) SHT P-405 BTU LOAD OF GAS APPLIANCES
 SHOWS 5,189,000 ON PLANS BUT ONLY ADDS
 UP TO 4,266,000. PLEASE CLAIRFY.
 23) SUBMIT CALCULATIONS FOR COMBUSTION
 AIR PER FBC-2001 FUEL GAS CODE SECTION
 304. SUBMIT MANUF. INFO. FOR COMBUSTION
 AIR DIRECT VENT.
 24) SUBMIT MANUF. SHEET FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, AND THE FBC-2001 FUEL
 GAS CODE SEC 402.2
 25) EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
 26) SHT P-402 SANT. RISERS B/4, B/5, B/6
 B/8, B/9, & KS/2 - VENT SHALL NOT TIE
 BACK INTO WASTE STACK AS SHOWN.
 27) SHTS P-402, & P-403 ALL VENT STACKS
 SHALL BE WASHED AT THE BASE. START ALL
 VENT STACKS FROM THE LOWEST FIXTURE
 GROUP.
 28) SHT P-403 RISERS B/15, B/16, & B/18
 VENT SHALL NOT TIE BACK INTO WASTE STACK
 AS SHOWN.
  
 WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377 OR805-6721
 FAX 653-2692
 BUILDING PLAN REVIEW

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-07-03 Cont ID  
Sent By kstevens Date 2002-07-03 Time 08:22 Rev Time 0.00
Received By kstevens Date 2002-07-03 Time 08:22 Sent To  
Notes
2002-07-03 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
 FBC-2001 FUEL GAS
 FBC-2001 SECTION 424 POOLS
  
 1) PLANS SHALL BE ROUTED TO THE PALM
 BEACH HEALTH UNIT, DIVISION OF ENVIRON-
 MENTAL HEALTH, 901 EVERNIA WPB (561) 355
 3018 FOR KITCHEN AND POOL.
 2) GREASE TRAP SHALL BE SIZED BY UTILITY
 DEPT. PLEASE CONTACT RODNEY COMPO,
 ENVIRONMENTAL MANAGER, (561) 837-4074.
 3) PLEASE PROVIDE CALCULATIONS FOR MINI-
 MUM FACILITIES. USE TABEL 403.1.
 4) SHTS A-201B - A-2.21B TOILET STALLS
 SHALL HAVE A LAV. SEE FIG 30E IN CHAPTER
 11 FBC-2001.
 5) SHT A-2.31 PLEASE SUBMIT CALCULATIONS
 FOR PRIMARY AND SECONDARY ROOF DRAINS
 PER SECTIONS 1106 & 1107. INCLUDE 1/2
 AREA OF ALL VERTICAL WALLS AND AREA OF
 ROOFS DRAINING ON TO ROOF FROM ABOVE.
 SHOW LOCATION OF SECONDARY DRAINS.
 6) PLEASE SUBMIT A STORM RISER DIAGRAM.
 SHOW ALL RISERS WITH TOTAL SQ FT OF EACH
 RISER AND SHOW TOTAL SQ FT AS IT ACCUMU-
 LATES IN STORM DRAIN.
 7) SHTS A-2.41, A-2.42, & A-2.43 ALL
 RESIDENTIAL UNITS SHALL COMPLY WITH FHA-
 AMEND 98 DESIGN MANUAL. ALL REQUIREMENTS
 #'S 1 THRU 7 SHALL BE MET, AND SPECIFI-
 CATION "A" OR "B" SHALL BE INDICATED ON
 PLANS FOR BATHROOMS. PLEASE SHOW CLEAR
 FLOOR SPACE AND INDICATE OPENING SIZE
 FOR EACH WATER CLOSET.
 8) SHT A-8.11 DETAILS #1,2,3,4,5,6,7.
 PLEASE SHOW CLEAR FLOOR SPACE FOR ALL
 HDCP FIXTURES. SHOW TURNING RADIUS IN
 EACH TOILET ROOM. DOORS SHALL NOT SWING
 INTO THE CLEAR FLOOR SPACE OF ANY FIXT-
 URE OR THE UNOBSTRUCTED TURNING RADIUS
 FOR ANY FIXTURE.
 9) SHT A-8.12 DETAIL #3 SHOW CONTROL
 HEIGHT FOR SHOWER. 11-4.21.5
 10) SHT P-101 PLUMBING NOTES #2 CODE IN
 EFFECT IS FBC-2001 PLUMBING NOT SPC.
 PLEASE CHANGE REFERENCE.
 11) SHT P-101 PLUMBING NOTES #3B - PER
 MANUF. INSTRUCTIONS, AIR TESTS ON PVC
 PIPE AND FITTINGS ARE NOT APPROVED.
 PLEASE CHANGE NOTE.
 12) SHT P-101 PLUMBING NOTES #5 - AIR
 CHAMBERS ARE NOT APPROVED. PLEASE DE-
 LETE REFERENCE.
 13) SHT P-102 WATER HEATER "A" DETAIL,
 COMBUSTION AIR INTAKE SHALL BE SIZED AND
 INSTALLED PER MANUFACTURE INSTALLATION
 INSTRUCTIONS. PLEASE PROVIDE INFORMATION
 14) SHT P-102 GREASE TRAP DETAIL. TWO
 WAY CLEAN OUTS REQUIRED ON BOTH SIDES OF
 THE GREASE TRAP. SEE ATTACHED SHEET FOR
 WPB APPROVED GREASE TRAP DETAIL.
 15) SHT P-201 SANITARY DRAINAGE PIPE
 (BURIED) DOES NOT MATCH LEDGEND ON SHT
 P-101. PLEASE CLAIRFY. PLEASE SHOW DIFF-
 ERENCE BETWEEN BURIED PIPE & PIPE ABOVE
 CEILING. (ALSO ON SHT P-202)
 16) SHT P-202 THERE ARE UNVENTED WATER
 CLOSETS, CLEAN OUTS REQUIRED (MINIMUM
 100' BETWEEN CLEAN OUTS 708.3.1), UNVEN-
 TED FIXTURES, TWO SANT DRAIN LINES TO
 THE SAME WATER CLOSET.
 17) SHT P-202 ITEM P-145 FILTER TO BE
 NSF APPROVED. PROVIDE MANUF INFO.
 18) SHTS P-202/P-203 ITEMS P145B, P125,
 & P142 FUNNEL DRAINS NOT APPROVED. ALL
 INDIRECT WASTE SHALL DRAIN TO A FLOOR
 SINK. 802.3
 19) SHT P-205 STORM DRAIN NOT SIZED FOR
 LINE THAT EXITS AT -48" ELEVATION.
 20) SHTS P-207, P-210, P-211, P-212,
 P-213, P-214, P-215, P-216, P-217, AND
 P-218. VARIOUS UNITS SHOW WATER LINES
 RUNNING TO RANGE/OVEN AND NOT TO KITCHEN
 SINK. SOME UNITS SHOW NO WATER TO KIT.
 SINKS. SOME UNITS SHOW WATER IN WALL
 ON THE OTHER SIDE OF ROOM FROM THE FIX-
 TURES IN BATHROOMS. PLEASE CHECK UNITS
 FOR THESE DISCREPANCIES.
 21) SHTS P-212, P-216, & P-217 PLEASE
 SHOW SIZE FOR WATER PIPES RUNNING IN
 CEILING ABOVE CORRIDOR.
 22) SHT P-301 BATHROOM PLAN, PLEASE SHOW
 CLEAR FLOOR SPACE FOR FIXTURES.
 23) SHTS P-302, & P-401, ALL INDIRECT
 WASTE SHALL DRAIN INTO A FLOOR SINK.
 FUNNEL FLOOR DRAINS NOT APPROVED. 802.3
 24) SHTS P-302 & P-401 DISH WASH MACHINE
 SHALL DRAIN TO SANITARY NOT GREASE WASTE
 UTILITY ORD.
 25) SHT P-401 DOMESTIC WATER RISER DIAG.
 WATER HAMMER ARRESTORS SHALL BE LOCATED
 NEAR FIXTURE IN AN "EFFECTIVE RANGE" NOT
 AT TOP OF DROP AS SHOWN. WH-PDI 201 &
 MANUFACTURE INSTALL. INSTRUCTIONS. ALSO
 SHOW PIPE SIZES FOR KITCHEN MAINS.
 26) SEPARATE PERMIT REQUIRED FOR GAS.
 SEE INFORMATION REQUIRED FOR GAS PERMIT
 APPLICATION BELOW.
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 C. TYPE OF GAS, (LP OR NATURAL)
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 FBC-2001 FUEL GAS CODE SECS.401.8 THRU
 402.5.2 & TABLES 402(1) THRU 402(34).
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3).
 F. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE. SEC 304. PLEASE SUBMIT MANUF.
 INFORMATION FOR COMBUSTION AIR DIRECT
 VENT.
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS SEC. 402.2. IF
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE FBC-
 2001 FUEL GAS CODE SEDC 402.2.
 I. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 J. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
 K. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
 27) SUPPLY A SANITARY RISER DIAGRAM FOR
 THE BLDG DRAIN. SHOW ALL RISER CONNECT-
 IONS WITH FIXTURE UNIT LOAD FOR EACH
 RISER AND SHOW FIXTURE UNITS AS THEY
 ACCUMULATE IN THE SYSTEM TO VERIFY PIPE
 SIZE OF BLDG DRAIN. SHOW HOW ALL VENT
 LINES TIE INTO BLDG DRAIN.
 28) P-402 RISERS B/4, B/5, B/6, B/9, &
 KS/2 VENT SHALL NOT TIE BACK INTO WASTE
 AS SHOWN.
 29) SHTS P-402 & P-403 ALL VENT STACKS
 SHALL BE WASHED AT THE BASE. START ALL
 VENT STACKS FROM THE LOWEST FIXTURE
 GROUP.
 30) SHT P-403 RISER B/16 2N FLOOR T-2
 NOT VENTED.
 31) SHT P-403 RISER B/15 W/C FOR 2ND
 FLOOR NOT VENTED.
 32) SHT P-403 RISERS B/15, B/16, B/18
 VENTS SHALL NO TIE BACK INTO WASTE STACK
 AS SHOWN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 4 Status P Date 2004-07-07 Cont ID  
Sent By mmclean Date 2004-07-07 Time 10:15 Rev Time 0.00
Received By mmclean Date 2004-07-07 Time 10:15 Sent To I
Notes
2004-07-07 00:00:00APPROVED BY JOSH LONG, PLANNER 659-8031

Review Stop Z ZONING
Rev No 3 Status P Date 2003-07-02 Cont ID  
Sent By lmartine Date 2003-07-02 Time 15:05 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2003-07-02 00:00:00APPROVED BY JOSH LONG 7/2/03

Review Stop Z ZONING
Rev No 2 Status F Date 2003-04-17 Cont ID  
Sent By sgraham Date 2003-04-17 Time 16:45 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-04-17 00:00:00DENIED, PENDING CITY COMMISSION APPROVAL

Review Stop Z ZONING
Rev No 1 Status F Date 2002-07-31 Cont ID  
Sent By sthyng Date 2003-03-13 Time 09:29 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-07-31 00:00:00DENIED, NEED APPROVED SITE PLAN


Account Summary | Usage Policy | Privacy Policy