Plan Review Details - Permit 02060282
| Plan Review Stops For Permit 02060282 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-06-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-06-18 |
Time |
19:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-06-18 |
Time |
19:24 |
Sent To |
B |
|
| Notes |
| 2002-06-18 00:00:00 | *********** REVISION NEEDED ********** | | | | | | 1)NOTE: PLEASE NOTE ITEMS REDLINED ON | | | PLANS. | | | MISSING RECEPTS PER 210-52/210-52-C-1/ | | | 210-52H/ ETC. ETC. | | | PLEASE NOTE MISSING EQUIPMENT GROUNDING | | | CONDUCTOR BETWEEN MAIN DISC AND PANEL. | | | SIZE PER 250-122 | | | | | | PLEASE SUBMIT THE REVISED PLANS BEFORE | | | FINAL ELECTRICAL INSPECTION IS CALLED | | | IN. IF THERE ARE ANY QUESTIONS, PLEASE | | | CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-10-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-10-01 |
Time |
15:51 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-10-01 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2002-10-01 00:00:00 | MECHANICAL PERMIT 02060291 | | | | | | SUBMITTAL OF DWG # 206389-L TO REPLACE | | | DWG # 606389-R. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-06-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-14 |
Time |
09:18 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-06-14 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2002-06-14 00:00:00 | PROVISO:MECHANICAL PERMIT 02060291 | | | | | | IF GAS DRYERS ARE INSTALLED - | | | SHOW COMPLIANCE FOR COMBUSTION AIR AS | | | PER 2001 FBC(M) CHAPTER 7. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-06-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-06-13 |
Time |
19:56 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-06-13 |
Time |
19:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2002-07-02 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2002-07-02 |
Time |
18:27 |
Rev Time |
3.00 |
| Received By |
lhatten |
Date |
2002-06-28 |
Time |
18:26 |
Sent To |
|
|
| Notes |
| 2002-07-02 00:00:00 | REVIEW & STAMPED PLANS 06/28/2002 | | | TRUSS ENG. OKED | | | CALC. FEES & PRINT CARDS 07/02/2002 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-06-11 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-06-11 |
Time |
12:44 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|