Plan Review Details - Permit 02051878
Plan Review Stops For Permit 02051878
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-11-05 Cont ID  
Sent By hmoser Date 2003-12-01 Time 14:30 Rev Time 1.00
Received By btrobaug Date 2003-11-05 Time 14:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-06-26 Cont ID  
Sent By lsmith Date 2003-10-30 Time 13:17 Rev Time 0.50
Received By btrobaug Date 2003-06-26 Time 12:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-07-12 Cont ID  
Sent By shernand Date 2003-06-25 Time 11:33 Rev Time 0.00
Received By btrobaug Date 2002-07-12 Time 12:08 Sent To R
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-06-17 Cont ID  
Sent By pkrauss Date 2002-06-14 Time 09:57 Rev Time 0.00
Received By btrobaug Date 2002-06-17 Time 14:01 Sent To R
Notes
2002-06-17 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE ANY NECESSARY CHANGES IN
 THE PLANS AND RESUBMIT FOR REVIEW.
  
 1} THE GROUNDS SHOWN ON THE RISER
 DIAGRAM AT PANELS "A","B"AND"C" CREATE
 A PARALLEL PATH TO GROUND WITH THE
 GROUNDED CONDUCTOR FROM MDP,AND MUST BE
 REMOVED PER 250-24(A)(5).
  
 2} THE WASHER(LAUNDRY) CIRCUIT LISTED ON
 PANEL "A" MUST COMPLY WITH 220-16(B).
 (1500 VA).
  
 3} AHU-1,2,& 3 SHOWN IN PANEL "A" MUST
 COMPLY WITH 424-3.(OCP & BC @ 125%)
  
 4} PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 5} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE, PER 210-12
  
 6} 2ND FLOOR NORTH STAIRWELL @ LAUNDRY,
 THE SMOKE DETECTOR DOESN'T COMPLY WITH
 2-5.2.1.2(DOOR INTERVENTION) NFPA-72.
  
 7} THE DISCONNECTS SHOWN ST THE ACCU'S
 MUST COMPLY WITH 110-26.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-20 Cont ID  
Sent By csiegber Date 2003-11-20 Time 17:21 Rev Time 0.00
Received By csiegber Date 2003-11-20 Time 17:21 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-31 Cont ID  
Sent By lsmith Date 2003-10-31 Time 08:53 Rev Time 0.00
Received By lsmith Date 2003-10-31 Time 08:53 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-30 Cont ID  
Sent By lsmith Date 2003-10-30 Time 13:17 Rev Time 0.00
Received By lsmith Date 2003-10-30 Time 13:17 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-25 Cont ID  
Sent By shernand Date 2003-06-25 Time 11:32 Rev Time 0.00
Received By shernand Date 2003-06-25 Time 11:32 Sent To E
Notes
2003-06-25 00:00:00BT DESK

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-12-01 Cont ID  
Sent By hmoser Date 2003-12-01 Time 14:29 Rev Time 0.50
Received By hmoser Date 2003-12-01 Time 14:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-12-01 Cont ID  
Sent By csiegber Date 2003-11-20 Time 17:21 Rev Time 0.40
Received By hmoser Date 2002-06-14 Time 09:34 Sent To E
Notes
2002-06-14 00:00:00PROVISO:MECHANICAL PERMIT 02051880
  
 CONDENSATE SHALL DISCHARGE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE AS
 PER 2001 FBC 1503.4.4.
  
 IF GAS DRYERS ARE INSTALLED -
 SHOW COMPLIANCE FOR COMBUSTION AIR AS
 PER 2001 FBC(M) CHAPTER 7.
  
 PLEASE PROVIDE MANUFACTURER INSTALLATION
 INSTRUCTIONS FOR THE FIREPLACE & THE
 GRILLE W/HOOD.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-08 Cont ID  
Sent By jleech Date 2002-06-08 Time 12:43 Rev Time 0.50
Received By jleech Date 2002-06-08 Time 12:42 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-09-18 Cont ID  
Sent By jwitmer Date 2002-09-18 Time 10:23 Rev Time 0.50
Received By jwitmer Date 2002-09-18 Time 10:23 Sent To  
Notes
2002-09-18 00:00:00REVISION: STRUCTURAL TUBE STEEL COLUMN
 DATED 9/12/02JW

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-07-18 Cont ID  
Sent By jwitmer Date 2002-07-18 Time 17:48 Rev Time 1.33
Received By jwitmer Date 2002-07-18 Time 17:48 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-07-01 Cont ID  
Sent By btrobaug Date 2002-07-12 Time 12:55 Rev Time 3.50
Received By jwitmer Date 2002-07-01 Time 15:05 Sent To  
Notes
2002-07-01 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02051878
 ADD: 6215 S FLAGLER DR
 CONT: JOHN MITCHELL, INC
 TEL: 655-6000
  
 ***PROJECT*** 01071037***
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 SOILS REPORT REQUIRES ENGINEER TO SIGN
 AND SEAL REPORT.
  
 2)1805.1 PILES. INVESTIGATION.
 THE INVESTIGATION AND REPORT SHALL IN-
 CLUDE BUT NOT LIMITED TO THE FOLLOWING:
 A- RECOMEMENDED PILE TYPE & INSTALLED
 CAPABILITIES.
 B- DRIVING CRITERIA
 C- INSTALLATION & FIELD INSPEC. PROCED
 D- PILE LOAD TEST
 E- DURABILITY OF PILE
 F- DESIGNATION OF BEARING STRAUM OR
 STRATA.
  
 3) THERE IS NO INFORMATION ON THE PILE
 OTHER THAN AUGER PILE. ADDITIONAL INFOR-
 MATION SHALL BE REQUIRED,SPACING, PILE
 CAPS,INSPECTIONS,IDENTIFCATION, PILE
 LOCATION PLAN. SEE 1805. 1-14, 1809 FOR
 CAST-IN-PLACE CONCRETE PILES.
  
 4)PROVIDE 2 CURRENT COPIES OF SIGNED &
 SEALED SURVEYS WITH PROPOSED IMPROVEMENT
 TO BE COMPLETED.
  
 5) PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BASE FLOOD ELEVATION, CITY CODE REQUIRES
 AN ADDITIONAL 6". THE MINIMUM ELEVATION
 FOR FINISH FLOOR 7'-6", THE POOL EQUIP-
 MENT AND A/C EQUIP. PADS MUST MEET THIS
 EQUIPMENT.
  
 6) IS THE FOOTER TO BE CONSIDERED AS
 GRADE BEAMS? INDICATE LOADS TO BE
 IMPOSED ON PILES OR PILE CAPS. ALSO ARE
 THE FLOORS TO BE CONSIDERED STRUCTURAL
 FLOORS?
  
 7)FL BLDG 1909.3 CONCRETE SLABS ON
 GRADE SHALL BE PROVIDED WITH JOINTS IN
 ACCORDANCE WITH ACI 224.3R OR OTHER
 APPROVED METHODS. JOINTS SHALL BE DESIGN
 ED BY AN ARCHETECT OR ENGINEER.
  
 8) TRUSS STORAGE ABOVE GARAGE TO BE
 DESIGNED FOR LIGHT STORAGE 125 LBS / SQ
 FT LIVE LOAD. 1604.1 (TABLE).
  
 9) TRUSS ENGINEERING TO BE SIGNED &
 SEALED BY THE TRUSS ENGINEER, TO BE
 REVIEWED BY THE DESIGN PROFESSIONAL/
 WITH APPROVAL. DUE @ TIME OF FIELD
 INSPECTION.
  
 10) PROVIDE THE MANUFACTURERS SPEC ON
 THE ELEVATOR. 3003.
  
 11) 2806 MANUFACTURED FIREPLACES,
 FALSE FIREPLACES 2807 PROVIDE MANUFACTUR
 ERS SPECIFICATIONS, FRESH AIR INTAKE
 REQUIREMENTS
  
 12)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
 A- FRONT DOOR MISSING REPORT,DOOR 102
 B- WINDOW N NOT TO BE USED, PAGE 6 IN-
 DICATES LEAD GLASS WINDOW
  
 13)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD. THIS MAY BE A INSTRUMENT TO
 USE FOR THE FRONT DOOR & WINDOW.
  
 14) 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 15) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED. INDICATE
 WHICH MULLIONS ARE TO BE USED IN EACH
 CASE, SEE MULLION LOAD CHART OF PRODUCT
 APPROVAL.
  
 16) EGRESS DOORS, MINIMUM CLEAR OPENING
 32" TABLE 1004, R-3, 1012.1.1.
  
 17)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop Z ZONING
Rev No 2 Status P Date 2002-06-07 Cont ID  
Sent By sgraham Date 2002-06-07 Time 14:13 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-06-05 Cont ID  
Sent By sgraham Date 2002-06-05 Time 09:31 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-06-05 00:00:00DENIED,OVER THE 30' HEIGHT REQUIREMENT