| Plan Review Stops For Permit 02051827 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-07-15 |
Time |
07:47 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2003-07-15 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2003-07-15 00:00:00 | REVISION# 4 5/16/03OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
N |
Date |
2003-05-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-14 |
Time |
09:37 |
Rev Time |
0.22 |
| Received By |
jwitmer |
Date |
2003-05-16 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2003-05-16 00:00:00 | GRINDER PUMP RISER NOT PART OF MY REVIEW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-05-05 |
Time |
16:22 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2003-05-05 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 02051827 | | | ADD: 512 SPENCER DRIVE | | | CONT: SHAKMAN | | | TEL: (561)239-9018 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | STOREFRONT SHOP DRAWINGS | | | | | | | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | SHOP DRAWINGS HAVE AN ENGINEERS TITLE- | | | BLOCK REQUIRING PLANS TO BE SIGNED & | | | SEALED. | | | | | | SITE SPECIFIC ENGINEERING (PRODUCT | | | APPROVAL) REQUIRES THE WET SIGNATURE, | | | DATE AND EMBOSSED SEAL OF THE ENGINEER | | | CERTIFYING THE PRODUCT AND SIGNATURE | | | AND SEAL OF THE DESIGN PROFESSIONAL | | | OF RECORD. | | | | | | JIM WITMER | | | BUIULDING PLAN REVIEW | | | (561)659-8096 X 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-28 |
Time |
12:29 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2003-01-23 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2003-01-23 00:00:00 | 01-23-03 TIE IN SURVEYJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-01-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-22 |
Time |
18:08 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-01-13 00:00:00 | REVISIONS SUBMITTED 121-05-02/ 01-08-03 | | | OKJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-10-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
15:17 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2002-10-21 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2002-10-21 00:00:00 | | | | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | PERMIT# 02051827 | | | ADDRESS: 512 SPENCER DR | | | CONT: SHAKMAN CONSTRUCTION | | | TELL # (561)750-8288 | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-09-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-09-08 |
Time |
14:46 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2002-09-08 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2002-09-08 00:00:00 | SEE COMMENTS FROM BEFORE NO PRODUCT TEST | | | ING REPORTS SUBMITTED FOR EITHER BLDG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-07-14 |
Time |
16:27 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2002-07-14 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2002-07-14 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 02051827 | | | ADD: 512 SPENCER DR | | | CONT: CATALFUMO | | | TEL: 694-8818 X 256 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | CONCESSION & RESTROOM | | | 1)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | WHAT IS THE PRIMARY OCCUPANCY OF THE | | | BUILDING THAT THE ADDITION WILL BE | | | BUILT AGAINST? | | | 2)TABLE 704.1 OCCUPANCY SEPERATION | | | REQUIREMENTS;BUSINESS 1 HR VS STORAGE | | | LOW HAZ 2 HR. 704.1.2.2(4) | | | 3)1511.7 ROOF MOUNTED MECHANICAL UNIT | | | S SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGTH IN ACCORDANCE WITH TABLE 1511.7. | | | 4) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORT, SBCCI OR DADE COUNTY | | | REPORT ARE ACCEPTED.MISSING REPORTS: | | | A) WINDOWS | | | B) MULLIONS | | | C) DOORS | | | D) ROOFING ASSEMBLIES, INSULATION& | | | ROOFING MEMBRANE | | | E) STORM SHUTTERS | | | 5)1707.4.5.1 MULLIONS OCCURRING | | | BETWEEN INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | 6)1707.4.5.2 MULLIONS SHALL BE DESIGN- | | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | | TO THE ROUGH OPENING SUBTRATE. | | | 7)1707.4.4.1 ANCHOR REQUIREMENTS: | | | WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR | | | ED IN ACCORDANCE WITH THE PUBLISHED | | | MANUFACTURER'S RECOMMENDATIONS TO | | | ACHIEVE THEDESIGN PRESSURE SPECIFIED. | | | SUBSTITUTE ANCHORING SYSTEM USED FOR | | | THE SUBSTRATE NOT SPECIFIED BY THE | | | FENESTRATION MANUFACTURER SHALL PROVIDE | | | EQUAL OR GREATER ANCHORING AS DEMONSTRA- | | | TED BY ACCEPTED ENGINEERING PRACTICES. | | | 8)FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | 9)FL BLDG 1909.3 (EXEPTION# 2) | | | CONCRETE SLABS ON GRADE CONTAINING 6X6/ | | | W1.4XW1.4 WELDED WIRE REINFORCEMENT | | | FABRIC LOCATED IN THE MIDDLE TO THE | | | UPPER 1/3RD OF THE SLAB SHALL BE SUP- | | | PORTED BY APPROVED MATERIALS OR SUPPORTS | | | AT SPACING NOT TO EXCEED 3 FT OR IN | | | ACCORDANCE WITH MANUFACTURER'S SPEC. | | | 10) 1204.2 SURROUNDING MATERIALS; | | | THE WALLS & FLOORS OF ALL PUBLIC REST- | | | ROOMS SHALL BE LINED WITH NONABSORBANT | | | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE | | | FLOOR. | | | | | | PRESS BOX | | | 1)11-4.1.3(1) AT LEAST ONE ACCESSIBLE | | | ROUTTE COMPLYING WITH 11-4.3 SHALL | | | CONNECT ACCESSIBLE BUILDING OR FACILITY | | | ENETRANCES WITH ALL ACCESSIBLE SPACES | | | AND ELEMENTS WITHIN THE BUILDING OR | | | FACILITY. | | | 2)11-4.1.2 VERTICAL ACCESSIBILITY, | | | NOTHING IN THIS CODE SHALL BE CONSTRUED | | | TO RELIEVE THE OWNER OF ANY BUILDING, | | | SSTRUCTURE OR FACILITY FROM THE DUTY TO | | | PROVIDE VERTICAL ACCESSIBILITY TO ALL | | | LEVELS ABOVE OR BELOW THE OCCUPIAABLE | | | GRADE LEVEL. | | | 3) HOW MANY SEATS DO THE EXISTING | | | BLEACHERS HOLD? | | | 4)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | ROOF HATCH, WHAT IS THE HATCH USE INTEND | | | ED FOR? NO GUARG RAIL INFORMATION ? | | | 5) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORT, SBCCI OR DADE COUNTY | | | REPORT ARE ACCEPTED. MISSING REPORTS | | | A) WINDOWS | | | B) MULLIONS | | | C)DOORS | | | D) ROOFINF MATERIALS | | | E) STORM SHUTTERS | | | SAME COMMENTS AS TO MULLIONS ETC FROM | | | CONCESSION STAND | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDEN- | | | TIFYING THE SHEET OR SPECIFICATION PAGE | | | WHERE THE CHANGES CAN BE FOUND, WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | JIM WITMER | | | PLAN REVIEW | | | TEL: (561)659-8096 EX.8412 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-14 |
Time |
10:20 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-07-14 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-23 |
Time |
17:35 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-05-23 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2003-05-23 00:00:00 | | | | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | AND RESUBMIT FOR REVIEW. | | | | | | 1} THE CIRCUIT #'S FOR THE HAND DRYERS 9 | | | & 17 ON THE SCHEDULE DON'T CORRELATE | | | WITH THE CIRCUIT NUMBERS ON THE PLAN. | | | | | | 2} PLEASE PROVIDE COMPLETED LOAD CALC'S | | | WITH TOTALS GIVEN. | | | | | | 3} PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, | | | DATEDAND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-28 |
Time |
15:55 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-28 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2003-04-28 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE PROVIDE INFORMATION ON | | | RISER/PANEL SCHEDULES AS TO NEW FEED | | | FOR LIFT STATION CONTROLLER RACK.? | | | PLEASE REVISE LOAD CALCUALTIONS FOR | | | ABOVE. PLEASE SHOW ALL CONTINOUS AND | | | MOTOR LOADS AT 125%. 215-3/230-42 | | | PLEASE SHOW LOAD CALCS. 220-3,220-10, | | | 220-11,220-13 ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | PLEASE ALSO NOTE, PER FS ALL PLANS/ | | | SHEETS SUBMITTED FOR RECORD MUST BE | | | SIGNED, DATED AND SEALED BY THE ARCH | | | OF RECORD. 481.221 | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | OWES REV FEE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-12-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-17 |
Time |
09:04 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-12-17 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-10-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-21 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-10-21 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2002-10-21 00:00:00 | RESTAMP ONLY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-07-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-07-09 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-07-09 |
Time |
07:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2002-06-26 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-06-26 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2002-06-26 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-17 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-17 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2003-07-17 00:00:00 | REVISION 7-11-03 NAM |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-25 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-25 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2003-06-25 00:00:00 | SEE ELECTRICAL NOTES PLANS ARE NOT | | | SEALED AND SIGNED. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2003-05-22 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-05-22 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-05-22 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2003-05-22 00:00:00 | 1) PLEASE REF NFPA 30 2000 EDITION FOR | | | UNDERGROUND TANKS. | | | | | | 2) PLEASE PROVIDE CUT SHEETS AND SPEC'S | | | FOR TANK. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-01-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-01-02 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-01-02 |
Time |
18:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-12-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-12-20 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-20 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-06-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-06-28 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-06-28 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2002-06-28 00:00:00 | NO COOKING THAT PRODUCES SMOKE OR | | | GREASE LADEN VAPORS IS PERMITTED UNLESS | | | COMPLIANCE WITH NFPA 96 IS ACCOMPLISHED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-14 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-14 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2003-07-14 00:00:00 | COMM BOARD #23 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-23 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-23 |
Time |
14:24 |
Sent To |
B |
|
| Notes |
| 2003-06-23 00:00:00 | JW DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-05-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-22 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-22 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2003-05-22 00:00:00 | DON NEELY, SUBMITTAL OF LETTER OF | | | COMPLETION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-05-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-22 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-22 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2003-05-22 00:00:00 | COMM BOARD #10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-28 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-28 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2003-04-28 00:00:00 | COMM BOARD #2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-28 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-28 |
Time |
12:29 |
Sent To |
B |
|
| Notes |
| 2003-04-28 00:00:00 | TO JW DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-01-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-22 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-21 |
Time |
18:05 |
Sent To |
B |
|
| Notes |
| 2003-01-22 00:00:00 | TO JIM./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-09 |
Time |
15:17 |
Sent To |
B |
|
| Notes |
| 2003-01-09 00:00:00 | TO JIM WITMER'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-05 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-05 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2002-12-05 00:00:00 | COMM BOARD #1./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-23 |
Time |
09:37 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2003-05-23 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2003-05-23 00:00:00 | NO MECHANICAL REVISION W/THIS SUBMITTAL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2002-09-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-09-23 |
Time |
12:36 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-09-23 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2002-09-23 00:00:00 | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW. | | | | | | 1.PROVIDE OUTSIDE AIR CALCULATIONS | | | AS PER 2001 FBC(M) TABLE 403.3 OR | | | ASHRAE 62-89. | | | | | | 2.PLEASE PROVIDE EQUIPMENT INFORMATION | | | IN ACCORDANCE WITH ENERGY CACLS. | | | | | | 3.PROVIDE DUCT MATERIAL, SIZE AND | | | LAYOUT. | | | | | | 4.INDICATE CONDENSATE LINE SIZE, | | | PIPING MATERIAL AND TERMINATION | | | POINT. | | | | | | PLEASE PROVIDE THE ABOVE INFORMATION | | | WITH MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-07-03 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2002-07-03 |
Time |
13:26 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2002-07-03 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2002-07-03 00:00:00 | DENIED | | | | | | PROVIDE OUTSIDE AIR CALCULATIONS SHOWING | | | COMPLIANCE WITH 2001 FBC(M) TABLE 403.3 | | | | | | PROVIDE MANUFACTURES INFORMATION ON | | | MECHANICAL EQUIPMENT | | | | | | ROOF MOUNTED EQUIPMENT TO COMPLY WITH | | | 2001 FBC 1511.7 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
N |
Date |
2003-06-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-14 |
Time |
13:34 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-06-14 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2003-06-14 00:00:00 | NO PLUMBING REVISION SUBMITTED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
N |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-27 |
Time |
08:37 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-05-27 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2003-05-27 00:00:00 | NO PLUMBING REVISION SUBMITTED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2003-03-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-20 |
Time |
17:50 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-03-20 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2003-03-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | REVISION DENIED - SAMPLE POINT NOT SHOWN | | | ON THE SANITARY RISER DIAGRAM OR THE | | | FLAT PIPING LAYOUT. THIS WAS REQUESTED | | | AT TIME OF PROVISO. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-10 |
Time |
13:07 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-01-10 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2003-01-10 00:00:00 | CALLED ENGINEER - WILL COME UP AND IN- | | | ITIAL CHANGES FOR APPROVAL. FORGOT TO | | | SHOW SAMPLE POINT REQUIRED BY UTILITY | | | DEPT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-10-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-10-18 |
Time |
13:13 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-10-18 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2002-10-18 00:00:00 | PASSED/PROVISO | | | | | | PER R. COMPO, A SAMPLE POINT IS REQUIRED | | | ON SANITARY LINE FROM CONCESSION STAND, | | | PRIOR TO SANITARY FROM TOILET ROOMS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-09-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-09-10 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-09-09 |
Time |
18:58 |
Sent To |
|
|
| Notes |
| 2002-09-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SHT A-6 ALL FLOOR SINKS SHALL BE | | | LOCATED UNDER FIXTURES SO AS NOT TO BE A | | | TRIPPING HAZARD. | | | 2) COMMENTS #5 & 6 FROM PREVIOUS REVIEW | | | HAVE NOT BEEN ADDRESSED. I HAVE CONTACT- | | | ED RODNEY COMPO AND HE WILL LET ME KNOW | | | IF A GREASE TRAP IS REQUIRED AND IF IT | | | IS REQUIRED THEN A GREASE LINE SHALL RUN | | | SEPARATE OUT OF THE BLDG. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-06-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-27 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-27 |
Time |
18:48 |
Sent To |
|
|
| Notes |
| 2002-06-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) ROUTE PLANS TO THE PALM BEACH COUNTY | | | HEALTH UNIT, DIVISION OF ENVIRONMENTAL | | | HEALTH. 901 EVERNIA STREET WPB 33401 | | | (561) 355-3018 PRIOR TO RESUBMITTING FOR | | | PLAN REVIEW. | | | 2) SHT A3 DETAILS 5/A-3 & 7/A-3 HDCP | | | TOILET SHALL BE 17" TO 19" HEIGH SECTION | | | 11-4.16.3 AND TOILET SHALL BE 18" FROM | | | CENTER TO WALL. FIG 28. | | | 3) SHT A6 PLUMBING NOTES #13 - AIR | | | CHAMBERS ARE NOT APPROVED. PLEASE DELETE | | | 4) SHT A6 FLOOR SINKS ARE REQUIRED FOR | | | ALL INDIRECT WASTE. THE FOLLOWING FIX- | | | TURES REQUIRE INDIRECT WASTE, 3-COMP | | | SINK, ICE MACHINE, & ALL SODA W/ICE BINS | | | PLEASE SHOW FLOOR SINKS FOR THESE FIXS. | | | 5) SHT A6 GREASE TRAP NOT APPROVED IN | | | CONCESSION STAND. PLEASE CONTACT RODNEY | | | COMPO, ENVIRONMENTAL COMPLIANCE MANAGER | | | FOR SIZE AND LOCATION OF GREASE TRAP. | | | (561) 837-4074. | | | 6) SHT A6 IF GREASE TRAP REQUIRED, THE | | | GREASE LINE WILL BE RUN SEPARATE FROM | | | THE SANITARY LINE. | | | 7) SHT A6 SANITARY RISER DIAGRAM AND | | | WATER RISER DIAGRAM, PLEASE SHOW ALL | | | PIPE SIZES FOR DRAINAGE, VENT, AND WATER | | | LINES. WATER HAMMER ARRESTORS ARE REQUI- | | | RED FOR QUICK CLOSING VALVES PER SEC | | | 604.9 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-06-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-22 |
Time |
18:06 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|