Plan Review Details - Permit 02051827
Plan Review Stops For Permit 02051827
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2003-07-15 Cont ID  
Sent By jwitmer Date 2003-07-15 Time 07:47 Rev Time 0.25
Received By jwitmer Date 2003-07-15 Time 07:47 Sent To  
Notes
2003-07-15 00:00:00REVISION# 4 5/16/03OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status N Date 2003-05-16 Cont ID  
Sent By shernand Date 2003-07-14 Time 09:37 Rev Time 0.22
Received By jwitmer Date 2003-05-16 Time 07:49 Sent To  
Notes
2003-05-16 00:00:00GRINDER PUMP RISER NOT PART OF MY REVIEW

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2003-05-05 Cont ID  
Sent By jwitmer Date 2003-05-05 Time 16:22 Rev Time 0.75
Received By jwitmer Date 2003-05-05 Time 16:22 Sent To  
Notes
2003-05-05 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02051827
 ADD: 512 SPENCER DRIVE
 CONT: SHAKMAN
 TEL: (561)239-9018
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
 STOREFRONT SHOP DRAWINGS
  
  
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 SHOP DRAWINGS HAVE AN ENGINEERS TITLE-
 BLOCK REQUIRING PLANS TO BE SIGNED &
 SEALED.
  
 SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD.
  
 JIM WITMER
 BUIULDING PLAN REVIEW
 (561)659-8096 X 8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2003-01-23 Cont ID  
Sent By sthyng Date 2003-04-28 Time 12:29 Rev Time 0.25
Received By jwitmer Date 2003-01-23 Time 13:45 Sent To  
Notes
2003-01-23 00:00:0001-23-03 TIE IN SURVEYJW

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-01-13 Cont ID  
Sent By btrobaug Date 2003-01-22 Time 18:08 Rev Time 0.55
Received By jwitmer Date   Time   Sent To  
Notes
2003-01-13 00:00:00REVISIONS SUBMITTED 121-05-02/ 01-08-03
 OKJW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-10-21 Cont ID  
Sent By dpalmer Date 2003-01-09 Time 15:17 Rev Time 1.00
Received By jwitmer Date 2002-10-21 Time 13:21 Sent To  
Notes
2002-10-21 00:00:00 
  
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02051827
 ADDRESS: 512 SPENCER DR
 CONT: SHAKMAN CONSTRUCTION
 TELL # (561)750-8288
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-09-08 Cont ID  
Sent By jwitmer Date 2002-09-08 Time 14:46 Rev Time 0.50
Received By jwitmer Date 2002-09-08 Time 14:46 Sent To  
Notes
2002-09-08 00:00:00SEE COMMENTS FROM BEFORE NO PRODUCT TEST
 ING REPORTS SUBMITTED FOR EITHER BLDG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-07-14 Cont ID  
Sent By jwitmer Date 2002-07-14 Time 16:27 Rev Time 2.00
Received By jwitmer Date 2002-07-14 Time 16:26 Sent To  
Notes
2002-07-14 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02051827
 ADD: 512 SPENCER DR
 CONT: CATALFUMO
 TEL: 694-8818 X 256
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 CONCESSION & RESTROOM
 1)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 WHAT IS THE PRIMARY OCCUPANCY OF THE
 BUILDING THAT THE ADDITION WILL BE
 BUILT AGAINST?
 2)TABLE 704.1 OCCUPANCY SEPERATION
 REQUIREMENTS;BUSINESS 1 HR VS STORAGE
 LOW HAZ 2 HR. 704.1.2.2(4)
 3)1511.7 ROOF MOUNTED MECHANICAL UNIT
 S SHALL BE MOUNTED ON CURBS RAISED A
 MINIMUM OF 8 INCHES ABOVE THE ROOF SUR-
 FACE, OR WHERE ROOFING MATERIALS EXTEND
 BENEATH THE UNIT, ON RAISED EQUIPMENT
 SUPPORTS PROVIDING A MINIMUM CLEARENCE
 HEIGTH IN ACCORDANCE WITH TABLE 1511.7.
 4) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.MISSING REPORTS:
 A) WINDOWS
 B) MULLIONS
 C) DOORS
 D) ROOFING ASSEMBLIES, INSULATION&
 ROOFING MEMBRANE
 E) STORM SHUTTERS
 5)1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
 6)1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
 7)1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
 8)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
 9)FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
 10) 1204.2 SURROUNDING MATERIALS;
 THE WALLS & FLOORS OF ALL PUBLIC REST-
 ROOMS SHALL BE LINED WITH NONABSORBANT
 MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE
 FLOOR.
  
 PRESS BOX
 1)11-4.1.3(1) AT LEAST ONE ACCESSIBLE
 ROUTTE COMPLYING WITH 11-4.3 SHALL
 CONNECT ACCESSIBLE BUILDING OR FACILITY
 ENETRANCES WITH ALL ACCESSIBLE SPACES
 AND ELEMENTS WITHIN THE BUILDING OR
 FACILITY.
 2)11-4.1.2 VERTICAL ACCESSIBILITY,
 NOTHING IN THIS CODE SHALL BE CONSTRUED
 TO RELIEVE THE OWNER OF ANY BUILDING,
 SSTRUCTURE OR FACILITY FROM THE DUTY TO
 PROVIDE VERTICAL ACCESSIBILITY TO ALL
 LEVELS ABOVE OR BELOW THE OCCUPIAABLE
 GRADE LEVEL.
 3) HOW MANY SEATS DO THE EXISTING
 BLEACHERS HOLD?
 4)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 ROOF HATCH, WHAT IS THE HATCH USE INTEND
 ED FOR? NO GUARG RAIL INFORMATION ?
 5) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS
 A) WINDOWS
 B) MULLIONS
 C)DOORS
 D) ROOFINF MATERIALS
 E) STORM SHUTTERS
 SAME COMMENTS AS TO MULLIONS ETC FROM
 CONCESSION STAND
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2003-07-14 Cont ID  
Sent By dpalmer Date 2003-07-14 Time 10:20 Rev Time 0.25
Received By dpalmer Date 2003-07-14 Time 10:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2003-05-23 Cont ID  
Sent By btrobaug Date 2003-05-23 Time 17:35 Rev Time 1.00
Received By btrobaug Date 2003-05-23 Time 16:05 Sent To  
Notes
2003-05-23 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 AND RESUBMIT FOR REVIEW.
  
 1} THE CIRCUIT #'S FOR THE HAND DRYERS 9
 & 17 ON THE SCHEDULE DON'T CORRELATE
 WITH THE CIRCUIT NUMBERS ON THE PLAN.
  
 2} PLEASE PROVIDE COMPLETED LOAD CALC'S
 WITH TOTALS GIVEN.
  
 3} PLEASE NOTE THAT ALL PLANS
 DRAWN BY AN ARCHITECT/ENGINEER CONTAIN-
 ING A TITLE BLOCK, MUST BE SIGNED,
 DATEDAND SEALED BY THE ARCH/ENGINEER OF
 RECORD. PER FS/FAC 481.221 & 471.025
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2003-04-28 Cont ID  
Sent By dpalmer Date 2003-04-28 Time 15:55 Rev Time 0.50
Received By dpalmer Date 2003-04-28 Time 15:55 Sent To  
Notes
2003-04-28 00:00:00************ UNSAT ***************
  
 1)NOTE: PLEASE PROVIDE INFORMATION ON
 RISER/PANEL SCHEDULES AS TO NEW FEED
 FOR LIFT STATION CONTROLLER RACK.?
 PLEASE REVISE LOAD CALCUALTIONS FOR
 ABOVE. PLEASE SHOW ALL CONTINOUS AND
 MOTOR LOADS AT 125%. 215-3/230-42
 PLEASE SHOW LOAD CALCS. 220-3,220-10,
 220-11,220-13 ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
 PLEASE ALSO NOTE, PER FS ALL PLANS/
 SHEETS SUBMITTED FOR RECORD MUST BE
 SIGNED, DATED AND SEALED BY THE ARCH
 OF RECORD. 481.221
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
 OWES REV FEE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-12-17 Cont ID  
Sent By dpalmer Date 2002-12-17 Time 09:04 Rev Time 0.25
Received By dpalmer Date 2002-12-17 Time 09:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-21 Cont ID  
Sent By dpalmer Date 2002-10-21 Time 14:58 Rev Time 0.00
Received By dpalmer Date 2002-10-21 Time 14:58 Sent To  
Notes
2002-10-21 00:00:00RESTAMP ONLY

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-09 Cont ID  
Sent By dpalmer Date 2002-07-09 Time 07:35 Rev Time 0.00
Received By dpalmer Date 2002-07-09 Time 07:35 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-06-26 Cont ID  
Sent By mamini Date 2002-06-26 Time 11:10 Rev Time 0.00
Received By mamini Date 2002-06-26 Time 11:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 6 Status P Date 2003-07-17 Cont ID  
Sent By nmccray Date 2003-07-17 Time 14:16 Rev Time 0.00
Received By nmccray Date 2003-07-17 Time 14:15 Sent To  
Notes
2003-07-17 00:00:00REVISION 7-11-03 NAM

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status F Date 2003-06-25 Cont ID  
Sent By nmccray Date 2003-06-25 Time 15:04 Rev Time 0.00
Received By nmccray Date 2003-06-25 Time 15:03 Sent To  
Notes
2003-06-25 00:00:00SEE ELECTRICAL NOTES PLANS ARE NOT
 SEALED AND SIGNED.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2003-05-22 Cont ID  
Sent By nmccray Date 2003-05-22 Time 15:57 Rev Time 0.00
Received By nmccray Date 2003-05-22 Time 15:57 Sent To  
Notes
2003-05-22 00:00:001) PLEASE REF NFPA 30 2000 EDITION FOR
 UNDERGROUND TANKS.
  
 2) PLEASE PROVIDE CUT SHEETS AND SPEC'S
 FOR TANK.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-01-02 Cont ID  
Sent By mcarsill Date 2003-01-02 Time 18:26 Rev Time 0.00
Received By mcarsill Date 2003-01-02 Time 18:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-12-20 Cont ID  
Sent By mcarsill Date 2002-12-20 Time 16:56 Rev Time 0.00
Received By mcarsill Date 2002-12-20 Time 16:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-06-28 Cont ID  
Sent By mcarsill Date 2002-06-28 Time 12:47 Rev Time 0.00
Received By mcarsill Date 2002-06-28 Time 12:47 Sent To  
Notes
2002-06-28 00:00:00NO COOKING THAT PRODUCES SMOKE OR
 GREASE LADEN VAPORS IS PERMITTED UNLESS
 COMPLIANCE WITH NFPA 96 IS ACCOMPLISHED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2003-07-14 Cont ID  
Sent By shernand Date 2003-07-14 Time 09:35 Rev Time 0.00
Received By shernand Date 2003-07-14 Time 09:35 Sent To  
Notes
2003-07-14 00:00:00COMM BOARD #23

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-23 Time 14:25 Rev Time 0.00
Received By shernand Date 2003-06-23 Time 14:24 Sent To B
Notes
2003-06-23 00:00:00JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-05-22 Cont ID  
Sent By shernand Date 2003-05-22 Time 16:58 Rev Time 0.00
Received By shernand Date 2003-05-22 Time 16:58 Sent To  
Notes
2003-05-22 00:00:00DON NEELY, SUBMITTAL OF LETTER OF
 COMPLETION.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-05-22 Cont ID  
Sent By shernand Date 2003-05-22 Time 16:56 Rev Time 0.00
Received By shernand Date 2003-05-22 Time 16:56 Sent To  
Notes
2003-05-22 00:00:00COMM BOARD #10

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-04-28 Cont ID  
Sent By shernand Date 2003-04-28 Time 12:36 Rev Time 0.00
Received By shernand Date 2003-04-28 Time 12:36 Sent To  
Notes
2003-04-28 00:00:00COMM BOARD #2

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-28 Cont ID  
Sent By sthyng Date 2003-04-28 Time 12:29 Rev Time 0.00
Received By sthyng Date 2003-04-28 Time 12:29 Sent To B
Notes
2003-04-28 00:00:00TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-01-22 Cont ID  
Sent By btrobaug Date 2003-01-22 Time 18:05 Rev Time 0.00
Received By btrobaug Date 2003-01-21 Time 18:05 Sent To B
Notes
2003-01-22 00:00:00TO JIM./WRT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-09 Cont ID  
Sent By dpalmer Date 2003-01-09 Time 15:17 Rev Time 0.00
Received By dpalmer Date 2003-01-09 Time 15:17 Sent To B
Notes
2003-01-09 00:00:00TO JIM WITMER'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-05 Cont ID  
Sent By btrobaug Date 2002-12-05 Time 16:19 Rev Time 0.00
Received By btrobaug Date 2002-12-05 Time 16:11 Sent To  
Notes
2002-12-05 00:00:00COMM BOARD #1./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2003-05-23 Cont ID  
Sent By pkrauss Date 2003-05-23 Time 09:37 Rev Time 0.10
Received By pkrauss Date 2003-05-23 Time 09:37 Sent To  
Notes
2003-05-23 00:00:00NO MECHANICAL REVISION W/THIS SUBMITTAL

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2002-09-23 Cont ID  
Sent By pkrauss Date 2002-09-23 Time 12:36 Rev Time 0.45
Received By pkrauss Date 2002-09-23 Time 11:56 Sent To  
Notes
2002-09-23 00:00:00INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.
  
 1.PROVIDE OUTSIDE AIR CALCULATIONS
 AS PER 2001 FBC(M) TABLE 403.3 OR
 ASHRAE 62-89.
  
 2.PLEASE PROVIDE EQUIPMENT INFORMATION
 IN ACCORDANCE WITH ENERGY CACLS.
  
 3.PROVIDE DUCT MATERIAL, SIZE AND
 LAYOUT.
  
 4.INDICATE CONDENSATE LINE SIZE,
 PIPING MATERIAL AND TERMINATION
 POINT.
  
 PLEASE PROVIDE THE ABOVE INFORMATION
 WITH MECHANICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-07-03 Cont ID  
Sent By ndenmark Date 2002-07-03 Time 13:26 Rev Time 0.33
Received By ndenmark Date 2002-07-03 Time 13:26 Sent To  
Notes
2002-07-03 00:00:00DENIED
  
 PROVIDE OUTSIDE AIR CALCULATIONS SHOWING
 COMPLIANCE WITH 2001 FBC(M) TABLE 403.3
  
 PROVIDE MANUFACTURES INFORMATION ON
 MECHANICAL EQUIPMENT
  
 ROOF MOUNTED EQUIPMENT TO COMPLY WITH
 2001 FBC 1511.7

Review Stop P PLUMBING
Rev No 7 Status N Date 2003-06-14 Cont ID  
Sent By kstevens Date 2003-06-14 Time 13:34 Rev Time 0.25
Received By kstevens Date 2003-06-14 Time 13:34 Sent To  
Notes
2003-06-14 00:00:00NO PLUMBING REVISION SUBMITTED

Review Stop P PLUMBING
Rev No 6 Status N Date 2003-05-27 Cont ID  
Sent By kstevens Date 2003-05-27 Time 08:37 Rev Time 0.25
Received By kstevens Date 2003-05-27 Time 08:36 Sent To  
Notes
2003-05-27 00:00:00NO PLUMBING REVISION SUBMITTED

Review Stop P PLUMBING
Rev No 5 Status F Date 2003-03-20 Cont ID  
Sent By kstevens Date 2003-03-20 Time 17:50 Rev Time 0.25
Received By kstevens Date 2003-03-20 Time 17:50 Sent To  
Notes
2003-03-20 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 REVISION DENIED - SAMPLE POINT NOT SHOWN
 ON THE SANITARY RISER DIAGRAM OR THE
 FLAT PIPING LAYOUT. THIS WAS REQUESTED
 AT TIME OF PROVISO.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 4 Status N Date 2003-01-10 Cont ID  
Sent By kstevens Date 2003-01-10 Time 13:07 Rev Time 0.75
Received By kstevens Date 2003-01-10 Time 13:06 Sent To  
Notes
2003-01-10 00:00:00CALLED ENGINEER - WILL COME UP AND IN-
 ITIAL CHANGES FOR APPROVAL. FORGOT TO
 SHOW SAMPLE POINT REQUIRED BY UTILITY
 DEPT.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-10-18 Cont ID  
Sent By kstevens Date 2002-10-18 Time 13:13 Rev Time 0.50
Received By kstevens Date 2002-10-18 Time 13:13 Sent To  
Notes
2002-10-18 00:00:00PASSED/PROVISO
  
 PER R. COMPO, A SAMPLE POINT IS REQUIRED
 ON SANITARY LINE FROM CONCESSION STAND,
 PRIOR TO SANITARY FROM TOILET ROOMS.

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-09-10 Cont ID  
Sent By kstevens Date 2002-09-10 Time 07:23 Rev Time 0.00
Received By kstevens Date 2002-09-09 Time 18:58 Sent To  
Notes
2002-09-10 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) SHT A-6 ALL FLOOR SINKS SHALL BE
 LOCATED UNDER FIXTURES SO AS NOT TO BE A
 TRIPPING HAZARD.
 2) COMMENTS #5 & 6 FROM PREVIOUS REVIEW
 HAVE NOT BEEN ADDRESSED. I HAVE CONTACT-
 ED RODNEY COMPO AND HE WILL LET ME KNOW
 IF A GREASE TRAP IS REQUIRED AND IF IT
 IS REQUIRED THEN A GREASE LINE SHALL RUN
 SEPARATE OUT OF THE BLDG.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-27 Cont ID  
Sent By kstevens Date 2002-06-27 Time 18:48 Rev Time 0.00
Received By kstevens Date 2002-06-27 Time 18:48 Sent To  
Notes
2002-06-27 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) ROUTE PLANS TO THE PALM BEACH COUNTY
 HEALTH UNIT, DIVISION OF ENVIRONMENTAL
 HEALTH. 901 EVERNIA STREET WPB 33401
 (561) 355-3018 PRIOR TO RESUBMITTING FOR
 PLAN REVIEW.
 2) SHT A3 DETAILS 5/A-3 & 7/A-3 HDCP
 TOILET SHALL BE 17" TO 19" HEIGH SECTION
 11-4.16.3 AND TOILET SHALL BE 18" FROM
 CENTER TO WALL. FIG 28.
 3) SHT A6 PLUMBING NOTES #13 - AIR
 CHAMBERS ARE NOT APPROVED. PLEASE DELETE
 4) SHT A6 FLOOR SINKS ARE REQUIRED FOR
 ALL INDIRECT WASTE. THE FOLLOWING FIX-
 TURES REQUIRE INDIRECT WASTE, 3-COMP
 SINK, ICE MACHINE, & ALL SODA W/ICE BINS
 PLEASE SHOW FLOOR SINKS FOR THESE FIXS.
 5) SHT A6 GREASE TRAP NOT APPROVED IN
 CONCESSION STAND. PLEASE CONTACT RODNEY
 COMPO, ENVIRONMENTAL COMPLIANCE MANAGER
 FOR SIZE AND LOCATION OF GREASE TRAP.
 (561) 837-4074.
 6) SHT A6 IF GREASE TRAP REQUIRED, THE
 GREASE LINE WILL BE RUN SEPARATE FROM
 THE SANITARY LINE.
 7) SHT A6 SANITARY RISER DIAGRAM AND
 WATER RISER DIAGRAM, PLEASE SHOW ALL
 PIPE SIZES FOR DRAINAGE, VENT, AND WATER
 LINES. WATER HAMMER ARRESTORS ARE REQUI-
 RED FOR QUICK CLOSING VALVES PER SEC
 604.9
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-25 Cont ID  
Sent By btrobaug Date 2003-01-22 Time 18:06 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***