Plan Review Details - Permit 02051346
Plan Review Stops For Permit 02051346
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-19 Cont ID  
Sent By dpalmer Date 2002-06-19 Time 17:31 Rev Time 0.00
Received By dpalmer Date 2002-06-19 Time 17:31 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-06-10 Cont ID  
Sent By dpalmer Date 2002-06-10 Time 07:52 Rev Time 0.00
Received By dpalmer Date 2002-06-10 Time 07:52 Sent To B
Notes
2002-06-10 00:00:00****************** UNSAT ***************
  
 1)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 PROTECTED CIRCUITS PER 210-12
  
 2)NOTE: PLEASE NOTE MISSING GFI FOR
 COND UNITS.
  
 3)NOTE: PLEASE CLARIFY POOL LIGHTS
 SHOWN AS #14 AWG AND 20A OCP. PLEASE
 CORRELATE.
  
 4)NOTE: PLEASE CLARIFY OVEN SHOWN AS
 ONLY 6KW.
  
 5)NOTE: PLEASE NOTE THAT ON THE BOTTOM
 OF LOAD CALCULATIONS, KW/.24V?
 PLEASE CLARIFY MISPRINT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-19 Cont ID  
Sent By pkrauss Date 2002-06-19 Time 16:44 Rev Time 0.45
Received By pkrauss Date 2002-06-19 Time 16:27 Sent To  
Notes
2002-06-19 00:00:00PROVISO:MECHANICAL PERMIT 02051349
  
 REFERENCE LAUNDRY ROOM - MAKEUP AIR
  
 PLEASE INDICATE ON PLAN COMPLIANCE WITH
 2001 FBC(M) CHAPTER 7, COMBUSTION AIR.
 1. PROVIDE MANUFACTURER SUBMITTAL OF THE
 GAS DRYER TO BE INSTALLED AND
 2. SHOW COMPLIANCE WITH 2001 FBC(M)
 703.2 #2 (A) & (B) OR
 3. PROVIDE LOUVERED DOOR
  
 CONDENSATE SHALL DISCHARGE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE AS
 PER 2001 FBC 1503.4.4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-06-08 Cont ID  
Sent By hmoser Date 2002-06-08 Time 08:15 Rev Time 0.75
Received By hmoser Date 2002-06-08 Time 08:39 Sent To  
Notes
2002-06-08 00:00:00PLAN DENIED
 1) MISSING RETURN AIR IN BEDROOM #3
 2) RETURN AIR IN LIBRARY IS TO SMALL
 3) MISSING DUCT SIZE IN MASTER BATH
 4) REFER TO SECTION 304.3 CONFINED
 SPACES.2001 GAS CODE(GAS DRYER)
 5) VARIFY TYPE OF VENTILATION USED FOR
 FRESH AIR.NATURAL SECTION 402 OR
 MECHANICAL SECTION 403
 6) CALCULATIONS FOR TYPE OF VENTILATION
 USED
 7) CONDENSATE MUST TERMINATE 12IN FROM
 BUILDING
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-06-26 Cont ID  
Sent By dpalmer Date 2002-06-19 Time 17:31 Rev Time 0.00
Received By kstevens Date 2002-06-26 Time 10:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-01 Cont ID  
Sent By jleech Date 2002-06-01 Time 12:21 Rev Time 0.50
Received By jleech Date 2002-06-01 Time 12:21 Sent To  
Notes
2002-06-01 00:00:00DENIED;
 PAGE A-6 SANITARY RISER DIAGRAM NOT TO
 CODE.
 A. BATH 2 W/C AND SHOWER NOTE VENTED
 AND PIPE NOT SIZED.
 B. MASTER BATH BIDET NOT VENTED. NOT
 TO FLOOR PLAN. ONLY 2 LAVS IN M/B
 SHOWN ON FLOOR PLAN 3 SHOWN ON
 RISER DIAGRAM.
 C. BATH 4 SHOWER UNVENTED.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT 8369

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-06-26 Cont ID  
Sent By lhatten Date 2002-06-26 Time 19:56 Rev Time 2.50
Received By lhatten Date 2002-06-19 Time 19:55 Sent To  
Notes
2002-06-26 00:00:00REVIEW & STAMPED PLANS06/19/2002
 CALC. FEES & PRINT CARDS 06/26/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-23 Cont ID  
Sent By sgraham Date 2002-05-23 Time 11:42 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***