Plan Review Details - Permit 02051031
Plan Review Stops For Permit 02051031
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-08-15 Cont ID  
Sent By jwitmer Date 2002-08-15 Time 16:22 Rev Time 0.13
Received By jwitmer Date   Time   Sent To  
Notes
2002-08-15 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02051031
 ADD: 807 GRANT ST
 CONT: MALCOLM CONSTRUCTION
 TEL: (561)733-4497
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ******PROVISO******
  
 PROVIDE COPIES OF SOILS REPORT WITH COR-
 RECTED ADDRESS (SIGNED/SEALED) FROM
 SOILS ENGINEER BEFORE FOUNDATION
 INSPECTION.
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-08-13 Cont ID  
Sent By jwitmer Date 2002-08-13 Time 13:33 Rev Time 1.00
Received By jwitmer Date 2002-08-13 Time 13:33 Sent To  
Notes
2002-08-13 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02051031
 ADD: 807 GRANT STREET
 CONT: MALCOLM CONSTRUCTION
 TEL: (954)733-4497
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) SOILS REPORT HAS 3 ADDRESSES, COVER
 PAGE 801 GRANT, SCRATCHED OUT INKED IN
 807, SHEET # 2 RE: 803 GRANT?
  
 2) ENGINEER CALLED AND DISCUSSED SHEET
 9D, THE ENGINEER OF RECORD DIDN'T MAKE
 CORRECTIONS TO SHEET, WILL CORRECT AT
 THE STATE LEVEL (MASTER) SHALL SUBMIT
 NEW SHEETS TO CONTRACTOR!
  
 3) PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-06-17 Cont ID  
Sent By jwitmer Date 2002-06-17 Time 07:42 Rev Time 0.00
Received By jwitmer Date 2002-06-17 Time 13:37 Sent To  
Notes
2002-06-17 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02051031
 ADD: 807 GRANT STREET
 CONT: "PLAN REVIEW" FL HOUS AUTH
 TEL: 835-1989
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 SAME PLAN REVIEW NOTES AS PERMIT
 02051028 801 GRANT STREET
 JIM WITMER
 PLAN REVIEW
 (561)659-8096 X8412

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2002-06-05 Cont ID  
Sent By dpalmer Date 2002-06-05 Time 05:35 Rev Time 0.00
Received By dpalmer Date 2002-06-05 Time 05:35 Sent To  
Notes
2002-06-05 00:00:00**************** NOTE *****************
  
 1)NOTE: PLEASE NOTE THAT A DCA APPROVED
 BLDG IS EXEMPT FROM ELECTRICAL PLAN
 REVIEW. HOWEVER THE ELECTRICAL SERVICE
 HOOK-UP AND GROUNDING REQUIRES SEPARATE
 PERMIT APPLICATION AND RISER DIAGRAM.
 INSPECTION FOR SERVICE/HOOK-UP.
  
 PLEASE SUBMIT THE ABOVEFOR REVIEW
 FOR SERVICE. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-08-15 Cont ID  
Sent By pkrauss Date 2002-08-15 Time 16:12 Rev Time 0.20
Received By pkrauss Date   Time   Sent To  
Notes
2002-08-15 00:00:00PROVISO:
  
 HAVE CORRECT ENERGY CALCS ON THE JOBSITE
 AT TIME OF INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2002-08-14 Cont ID  
Sent By pkrauss Date 2002-08-14 Time 08:43 Rev Time 0.35
Received By pkrauss Date 2002-08-14 Time 08:43 Sent To  
Notes
2002-08-14 00:00:00DENIED:2ND REQUEST
  
 1.PLEASE PROVIDE INFORMATION ON A/C
 EQUIPMENT TO BE INSTALLED.
  
 2.SEER ON THE ENERGY CALCS INDICATE
 9.70.FLA ENERGY CODE REQUIRES NO
 LESS THAN A 10 SEER ON A SPLIT
 SYSTEM.9.70 IS PERMITTED FOR A
 PACKAGE UNIT.PLEASE CLARIFY WHAT
 TYPE OF EQUIPMENT IS TO BE INSTALLED
 2001 FBC CHAPTER 13 TABLE 6-3.
  
 REF:PAGE 6A - "APPLICATION ENGINEERING
 FOR HEATING & COOLING" HVAC SYSTEM
 TYPE:OVERHEAD FURNACE. IS THIS
 THE EQUIPMENT FOR THE A/C SYSTEM?
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-06-04 Cont ID  
Sent By hmoser Date 2002-06-04 Time 19:53 Rev Time 0.00
Received By jleech Date 2002-06-04 Time 19:52 Sent To  
Notes
2002-06-04 00:00:00PLAN DENIED
 1) NO INFORMATION ON CONDENSOR
 2) ENERGY CALCS CALL FOR 9070 SEER
 NEED NO LESS THAN 10.0 SEER
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-04 Cont ID  
Sent By jleech Date 2002-06-04 Time 20:12 Rev Time 0.25
Received By jleech Date 2002-06-04 Time 20:12 Sent To  
Notes
2002-06-04 00:00:00PREFAB HOME WATER AND SEWER ONLY

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-21 Cont ID  
Sent By sgraham Date 2002-05-21 Time 14:04 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***