Plan Review Details - Permit 02050967
Plan Review Stops For Permit 02050967
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-08-02 Cont ID  
Sent By lsmith Date 2002-08-02 Time 16:21 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-07-30 Cont ID  
Sent By dpalmer Date 2002-07-25 Time 06:38 Rev Time 1.00
Received By lsmith Date   Time   Sent To  
Notes
2002-07-30 00:00:00********************FAILED**************
 1. PLANS DO NOT SHOW POOL SHAPE AS WAS
 ORIGINALLY APPROVED BY ME ON 9/4/02.
 ORIGINAL PLANS APPROVED BY ME SHOW
 THERE WERE INSPECTIONS PERFORMED AT
 THIS SITE ON 10/9/02 & 10/10/02.POOL
 STEEL, BONDING & MAIN DRAIN.PLEASE
 VERIFY THE TRUE SHAPE OF THE EXISTING
 POOL. POOL EQUIPMENT PAD CANNOT BE
 PLACED IN UTILITY EASEMENT AS SHOWN ON
 OLANS.
 2. DETAIL OF POOL EQUIPMENT PAD MUST BE
 SHOWN ON PLANS INCLUDING TYPE OF ANCHORS
 USED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-01 Cont ID  
Sent By btrobaug Date 2002-08-01 Time 14:16 Rev Time 0.00
Received By btrobaug Date 2002-08-01 Time 13:24 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-07-25 Cont ID  
Sent By sgraham Date 2002-07-25 Time 6.45 Rev Time 0.00
Received By dpalmer Date 2002-07-25 Time 06:38 Sent To B
Notes
2002-07-25 00:00:00************ UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT AN ELECTRICAL
 DIAGRMA IS REQ`D FOR ALL EQUIPMENT
 PERTAINING TO POOL. LTS/DISC/PUMPS/
 HEATERS/ ETC.
  
 2)NOTE: PLEASE NOTE THAT PLAN SHOWS
 PIPE GOING TO OLD LOCATION OF EQUIPMENT
 AND A NEW EQUIPMENT PAD IS BEING SHOWN.
 PLEASE NOTE THAT THE EQUIPMENT MAY NOT
 BE INSTALLED IN FPL`S EASEMENT UNLESS
 EASEMENT IS RELEASED BY FPL. PLEASE
 NOTE , ORIGINAL LOCATION IS SHOWN ON
 OWNERS PROPERTY.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
2002-05-17 00:00:00NEED TO SHOW LOCCATION OF POOL ON SITE
 PLAN

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-08-02 Cont ID  
Sent By kstevens Date 2002-08-02 Time 16:17 Rev Time 0.00
Received By kstevens Date 2002-08-02 Time 16:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-07-23 Cont ID  
Sent By btrobaug Date 2002-08-01 Time 14:16 Rev Time 0.00
Received By kstevens Date 2002-07-23 Time 14:22 Sent To  
Notes
2002-07-23 00:00:00DENIED
 REFERENCE: SPC-94- UNIFORM COUNTYWIDE
 SWIMMING POOL AND SPA CODE.
  
 1) PLEASE PROVIDE A PIPING SCHEMATIC.
 SHOW PUMP, FILTER, HAIR & LINT STRAINER,
 CHLORINATOR, AND VALVES AT EQUIPMENT PAD
 AND SHOW LINES TO MAIN DRAIN, SKIMMER,
 POOL RETURN, WASTE, VACUMM, SHEAR DECENT
 WATERFALL, AND THERAPY JETS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-07-22 Cont ID  
Sent By kstevens Date 2002-07-22 Time 19:42 Rev Time 0.00
Received By kstevens Date 2002-07-22 Time 19:42 Sent To  
Notes
2002-07-22 00:00:00DENIED
 REFERENCE: FBC-2001 424 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5
 3) N/A
 4) FBC-2001 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 5) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 6) FBC-2001424.2.6.6.3 (1,2,3) ENTRAP-
 MENT AVOIDANCE. (DETAIL)
 7) FBC-2001424.2.6.6.4 MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR EA
 PUMP. SEPARATED BY A MINIMUM OF 3 FEET
 OR LOCATED ON TWO DIFFERENT PLANES.
 (DETAIL)
 8) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 9) FBC-2001424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND LINT
 STRAINER WHEN USED WITH A PRESSURE FIL-
 TER. (DETAIL)
 10) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 11) FBC-2001 424.2.8.1 VALVES SHALL BE
 MADE OF MATERIALS THAT ARE APPROVED IN
 THE FLA BLDG CODE, PLUMBING. THEY WILL
 BE READILY ACCESSIBLE FOR MAINT. AND RE-
 MOVAL. SEC 424.2.8.2 FULL WAY VALVES
 SHALL BE INSTALLED TO INSURE PROPER FUN-
 CTION OF THE FILTRATION AND PIPING SYS-
 TEM. SEC 424.2.8.3 WHERE CHECK VALVES
 ARE INSTALLED THEY SHALL BE OF THE SWING
 OR VERTICAL CHECK PATTERNS. SEC 424.2.8.
 4 COMBINATION VALVES SHALL REQUIRE APP-
 ROVAL OF THE ADMINISTRATIVE AUTHORITY
 PRIOR TO THEIR INSTALLATION.
 12) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 13) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 14) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 15) TIMER REQUIRED FOR PUMP PER FBC SEC
 612.1.ABC.2.3.3
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2002-07-22 Cont ID  
Sent By sgraham Date 2002-07-22 Time 15:26 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-05-17 Cont ID  
Sent By sgraham Date 2002-05-17 Time 10:02 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-05-17 00:00:00NEED TO SHOW LOCATION OF POOL ON SITE
 PLAN