| Plan Review Stops For Permit 02050729 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-07-08 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2002-07-08 |
Time |
16:09 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-07-02 00:00:00 | REVISION REVIEWED 7/2/02 WRS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-05-24 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-24 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-07-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-07-11 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-07-11 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-06-27 |
Time |
06:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-06-27 |
Time |
06:25 |
Sent To |
|
|
| Notes |
| 2002-06-27 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE NOTE THAT MAIN ELECTRICAL | | | ROOM LAYOUT SHOWS "NEW DISC" AT 200A | | | FROM BUS DUCT, PLEASE NOTE THAT RISER | | | DIAGRAM SHOWS AS 100A W/ 70A FUSES? | | | PLEASE CLARIFY WHICH ONE. | | | | | | 2)NOTE: PLEASE INDICATE GFI/GFI PROTECT- | | | ION FOR OUTLETS IN BREAK ROOM. PER | | | LOCAL AMENDMENTS 210-8 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-05-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-05-24 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-05-24 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-07-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-07-02 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-07-02 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-06-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-06-06 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-06-06 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2002-06-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-22 |
Time |
09:15 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2002-06-22 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2002-06-22 00:00:00 | NO MECHANICAL REVISIONS SUBMTTED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-05-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-31 |
Time |
13:10 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-05-31 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-07-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-07-11 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-11 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2002-07-11 00:00:00 | REVISION OK - P.O.U. WATER HEATER APPRO- | | | VAL - W.H.A. LOCATION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-07-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-07-05 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-05 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2002-07-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P2.1 WATER ISOMETRIC, PLEASE | | | SUBMIT MANUFACTURE INFO FOR TANKLESS | | | WATER HEATER. MUST SHOW LISTED TESTING | | | AGENCY APPROVAL. | | | 2) SHT P2.1 WATER ISOMETRIC, WATER HAMM- | | | ER SHALL BE LOCATED NEAR FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT AT TOP OF DROP AS | | | SHOWN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-06-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-03 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-03 |
Time |
17:40 |
Sent To |
|
|
| Notes |
|
|