Plan Review Details - Permit 02050678
Plan Review Stops For Permit 02050678
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-03 Cont ID  
Sent By dpalmer Date 2002-06-03 Time 06:18 Rev Time 0.00
Received By dpalmer Date 2002-06-03 Time 06:18 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-12-04 Cont ID  
Sent By pkrauss Date 2002-12-04 Time 10:44 Rev Time 0.35
Received By pkrauss Date 2002-12-04 Time 10:28 Sent To  
Notes
2002-12-04 00:00:00MECHANICAL REVISION PERMIT 02050688

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-26 Cont ID  
Sent By hmoser Date 2002-06-26 Time 17:58 Rev Time 0.50
Received By hmoser Date 2002-06-26 Time 17:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-06-04 Cont ID  
Sent By dpalmer Date 2002-06-03 Time 06:18 Rev Time 0.40
Received By hmoser Date 2002-06-04 Time 09:35 Sent To R
Notes
2002-06-04 00:00:00*******************DENIED***************
  
 MECHANICAL PERMIT 02050688
  
 PLAN SHEET MP-1 LIVING AREA INDICATES
 2200 CFM.PLEASE CORRECT.
  
 PLAN SHEET MP-2 TWO FAN SCHDULES ON
 PLAN (ONE SHOULD BE FOR A/C EQUIPMENT
 SCHEDULE) AHU LISTED IS A 5 TON SYSTEM.
 PLANS INDICATE A 4 TON SYSTEM.PLEASE
 CORRELATE.
  
 PROVIDE OVERFLOW PROTECTION AS PER 2001
 FBC(M) 307.2.4.
  
 SMOKE DETECTORS SHALL BE INSTALLED IN
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTORS
 WITH NOTIFICATION TO ALARM/STOBE OR AREA
 SMOKE DETECTORS. 2001 FBC(M) 606.4.1
  
 CONDENSATE SHALL DISCHARGE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE AS
 PER 2001 FBC 1503.4.4.
  
 PLEASE NOTE PROGRAMMABLE THERMOSAT
 REQUIRED AS PER ENERGY CALCS, HVAC
 CREDITS.
  
 DRYER VENT SHALL NOT EXCEED 25' AS PER
 2001 FBC(M) 504.6.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-01 Cont ID  
Sent By jleech Date 2002-06-01 Time 08:36 Rev Time 0.33
Received By jleech Date 2002-06-01 Time 08:36 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-06-11 Cont ID  
Sent By hmoser Date 2002-06-26 Time 17:49 Rev Time 2.50
Received By lhatten Date 2002-06-08 Time 19:23 Sent To  
Notes
2002-06-11 00:00:00REVIEW & STAMPED PLANS 06/08/2002
 CALC. FEES & PRINT CARDS 06/11/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-17 Cont ID  
Sent By sgraham Date 2002-05-17 Time 12:20 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***