Plan Review Details - Permit 02050585
Plan Review Stops For Permit 02050585
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-09-25 Cont ID  
Sent By jwitmer Date 2002-09-25 Time 14:17 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-09-25 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02050585
 ADD: 941 44TH ST
 CONT: O/B DOUGLAS, ESTELLA
 TEL: (561)848-0633
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 *****PROVISO*****
  
 MISSING PRODUCT APPROVALS ARE TO BE
 SUBMITTED BEFORE BUCK INSPECTION :
 A) MULLIONS
 B) ROOF ASSEMBLIES
 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-06-11 Cont ID  
Sent By jwitmer Date 2002-06-11 Time 13:50 Rev Time 1.25
Received By jwitmer Date   Time   Sent To  
Notes
2002-06-11 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02050585
 ADD: 941 44TH ST
 CONT: O/B DOUGLAS, ESTELLA
 TEL:848-0633
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1)FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
  
 2)FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS. PLANS WERE DESIGNED
 UNDER 130MPH, HANDWRITTEN IS 140MPH,
 NO NOTE FROM THE DESIGN PROFESSIONAL
 THAT IS INITIALED NOR SEALED LETTER.
  
 3)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 A) WINDOWS
 B) DOORS
 C) ROOFING MATERIALS
 D) STORM SHUTTERS
 E) MULLIONS
  
 4)1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 5)1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 6) DISCREPANCY:NORTH ELE. MISSING THE
 BATHROOM WINDOW.
  
 7) FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
  
 8) BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.
  
 ANY QUESTIONS PLEASE CALL,
 JIM WITMER
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8412

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-10-07 Cont ID  
Sent By btrobaug Date 2002-10-07 Time 13:30 Rev Time 0.50
Received By btrobaug Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-09-26 Cont ID  
Sent By btrobaug Date 2002-09-26 Time 08:32 Rev Time 0.50
Received By btrobaug Date 2002-09-26 Time 07:58 Sent To P
Notes
2002-09-26 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION AND MAKE ANY NECESSARY
 CHANGES ON THE PLAN.
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2} INDICATE THE LOCATION OF THE NEW
 PANEL ON THE PLANS.
  
 3} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12.THE
 FLORIDA ROOM COULD BE CONVERTED INTO A
 SLEEPING ROOM.THE SMOKE DETECTORS MEET
 THE INTENT OF NFPA-72,BUT NOTE THE
 LOCATION OF THE ONE OUTSIDE THE
 BATHROOM MUST COMPLY WITH 8-1.4.2.(3'
 AWAY FROM THE DOOR).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL;
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/659-8096 EXT. 8392

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-05-15 Cont ID  
Sent By btrobaug Date 2002-05-15 Time 13:23 Rev Time 0.00
Received By btrobaug Date 2002-05-15 Time 13:05 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-05-18 Cont ID  
Sent By kstevens Date 2002-05-18 Time 16:02 Rev Time 0.33
Received By hmoser Date 2002-05-18 Time 16:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-10-04 Cont ID  
Sent By pschmitz Date 2002-10-04 Time 08:31 Rev Time 0.75
Received By pschmitz Date   Time   Sent To  
Notes
2002-10-04 00:00:00APPROVED, PES

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-05-18 Cont ID  
Sent By btrobaug Date 2002-09-26 Time 08:32 Rev Time 0.00
Received By kstevens Date 2002-05-18 Time 16:02 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-14 Cont ID  
Sent By sgraham Date 2002-05-14 Time 16:33 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***