Plan Review Details - Permit 02050502
Plan Review Stops For Permit 02050502
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-06-07 Cont ID  
Sent By lsmith Date 2002-06-07 Time 11:54 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-05-23 Cont ID  
Sent By btrobaug Date 2002-05-23 Time 06:47 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2002-05-23 00:00:00******************FAILED****************
  
  
 1. NEED CONTRACT TO VERIFY VALUE
 2. NEED METHOD OF PROTECTION FROM HOUSE
 TO POOL AREA PER FBC2001 CHAPTER 424
 3. NEED ANCHORING DETAIL FOR POOL
 EQUIPMENT & SLAB
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-07 Cont ID  
Sent By btrobaug Date 2002-06-07 Time 11:41 Rev Time 0.00
Received By btrobaug Date 2002-06-07 Time 11:20 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-05-23 Cont ID  
Sent By kstevens Date 2002-05-22 Time 16:00 Rev Time 0.00
Received By btrobaug Date 2002-05-23 Time 06:21 Sent To B
Notes
2002-05-23 00:00:00UNSAT
 ~~~~~
  
 PLEASE SUBMIT A LOAD CALCULATION FOR
 THE SERVICE INCLUDING ALL ADDITIONAL
 LOADS BEING ADDED.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-06-07 Cont ID  
Sent By kstevens Date 2002-06-07 Time 11:48 Rev Time 0.00
Received By kstevens Date 2002-06-07 Time 11:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-05-22 Cont ID  
Sent By btrobaug Date 2002-06-07 Time 11:42 Rev Time 0.00
Received By kstevens Date 2002-05-22 Time 16:00 Sent To E
Notes
2002-05-22 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 3) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 4) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-14 Cont ID  
Sent By sgraham Date 2002-05-14 Time 16:22 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***